{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,3]],"date-time":"2026-03-03T02:04:31Z","timestamp":1772503471018,"version":"3.50.1"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2015,11,12]],"date-time":"2015-11-12T00:00:00Z","timestamp":1447286400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BioChip J"],"published-print":{"date-parts":[[2016,3]]},"DOI":"10.1007\/s13206-016-0102-2","type":"journal-article","created":{"date-parts":[[2015,11,10]],"date-time":"2015-11-10T15:43:45Z","timestamp":1447170225000},"page":"9-15","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":31,"title":["In vitro blood flow and cell-free layer in hyperbolic microchannels: Visualizations and measurements"],"prefix":"10.1007","volume":"10","author":[{"given":"Raquel O.","family":"Rodrigues","sequence":"first","affiliation":[]},{"given":"Raquel","family":"Lopes","sequence":"additional","affiliation":[]},{"given":"Diana","family":"Pinho","sequence":"additional","affiliation":[]},{"given":"Ana I.","family":"Pereira","sequence":"additional","affiliation":[]},{"given":"Valdemar","family":"Garcia","sequence":"additional","affiliation":[]},{"given":"Stefan","family":"Gassmann","sequence":"additional","affiliation":[]},{"given":"Patr\u00edcia C.","family":"Sousa","sequence":"additional","affiliation":[]},{"given":"Rui","family":"Lima","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2015,11,12]]},"reference":[{"key":"102_CR1","doi-asserted-by":"crossref","unstructured":"Lima, R., Ishikawa, T., Imai, Y. & Yamaguchi, T. in In Single and two-Phase Flows on Chemical and Biomedical Engineering, edited by Ricardo Dias, Antonio A. Martins, Rui Lima and T.M. Mata (Bentham science, 2012), pp. 513\u2013547.","DOI":"10.2174\/978160805295011201010513"},{"key":"102_CR2","unstructured":"Garcia, V., Dias, R. & Lima, R. in Applied Biological Engineering - Principles and Practice, edited by G. R. Naik (InTech, 2012), pp. 393\u2013416."},{"key":"102_CR3","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1111\/j.1549-8719.2010.00056.x","volume":"17","author":"D.A. Fedosov","year":"2010","unstructured":"Fedosov, D.A., Caswell, B., Popel, A.S. & Karniadakis, G.E. Blood flow and cell-free layer in microvessels. Microcirculation (New York, N.Y.: 1994) 17, 615\u2013628 (2010).","journal-title":"Microcirculation (New York, N.Y.: 1994)"},{"key":"102_CR4","doi-asserted-by":"crossref","first-page":"181","DOI":"10.3233\/BIR-2009-0530","volume":"46","author":"S. Kim","year":"2009","unstructured":"Kim, S., Ong, P.K., Yalcin, O., Intaglietta, M. & Johnson, P.C. The cell-free layer in microvascular blood flow. Biorheology 46, 181\u2013189 (2009).","journal-title":"Biorheology"},{"key":"102_CR5","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1007\/978-94-007-7769-9_4","volume":"12","author":"B. Namgung","year":"2014","unstructured":"Namgung, B., Liang, L. & Kim, S. in Visualization and Simulation of Complex Flows in Biomedical Engineering, edited by R. Lima, Y. Imai, T. Ishikawa and M. S. N. Oliveira (Springer Netherlands, 2014), Vol. 12, pp. 75\u201387.","journal-title":"Visualization and Simulation of Complex Flows in Biomedical Engineering"},{"key":"102_CR6","doi-asserted-by":"crossref","first-page":"034011","DOI":"10.1088\/1748-6041\/3\/3\/034011","volume":"3","author":"M. Abkarian","year":"2008","unstructured":"Abkarian, M. et al. Cellular-scale hydrodynamics. Biomed. Mater. 3, 034011 (2008).","journal-title":"Biomed. Mater."},{"key":"102_CR7","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1007\/s13206-013-7408-0","volume":"7","author":"D. Pinho","year":"2013","unstructured":"Pinho, D., Yaginuma, T. & Lima, R. A microfluidic device for partial cell separation and deformability assessment. BioChip J. 7, 367\u2013374 (2013).","journal-title":"BioChip J."},{"key":"102_CR8","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.1007\/s10544-009-9319-3","volume":"11","author":"S.S. Lee","year":"2009","unstructured":"Lee, S.S., Yim, Y., Ahn, K.H. & Lee, S.J. Extensional flow-based assessment of red blood cell deformability using hyperbolic converging microchannel. Biomed Microdevices 11, 1021\u20131027 (2009).","journal-title":"Biomed Microdevices"},{"key":"102_CR9","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1007\/s13206-014-8107-1","volume":"8","author":"V. Faustino","year":"2014","unstructured":"Faustino, V. et al. Extensional flow-based microfluidic device: deformability assessment of red blood cells in contact with tumor cells. BioChip J. 8, 42\u201347 (2014).","journal-title":"BioChip J."},{"key":"102_CR10","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1007\/978-94-007-7769-9_9","volume":"12","author":"V. i. Faustino","year":"2014","unstructured":"Faustino, V. et al. in Visualization and Simulation of Complex Flows in Biomedical Engineering, edited by R. Lima, Y. Imai, T. Ishikawa and M. S. N. Oliveira (Springer Netherlands, 2014), Vol. 12, pp. 151\u2013163.","journal-title":"Visualization and Simulation of Complex Flows in Biomedical Engineering"},{"key":"102_CR11","doi-asserted-by":"crossref","first-page":"054110","DOI":"10.1063\/1.4820414","volume":"7","author":"T. Yaginuma","year":"2013","unstructured":"Yaginuma, T., Oliveira, M.S.N., Lima, R., Ishikawa, T. & Yamaguchi, T. Human red blood cell behavior under homogeneous extensional flow in a hyperbolic-shaped microchannel. Biomicrofluidics 7, 054110 (2013).","journal-title":"Biomicrofluidics"},{"key":"102_CR12","doi-asserted-by":"crossref","first-page":"14108","DOI":"10.1063\/1.3567888","volume":"5","author":"P.C. Sousa","year":"2011","unstructured":"Sousa, P.C., Pinho, F.T., Oliveira, M.S. & Alves, M.A. Extensional flow of blood analog solutions in microfluidic devices. Biomicrofluidics 5, 14108 (2011).","journal-title":"Biomicrofluidics"},{"key":"102_CR13","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/0377-0257(90)85064-6","volume":"35","author":"D.F. James","year":"1990","unstructured":"James, D.F., Chandler, G.M. & Armour, S.J. Measurement of the extensional viscosity of M1 in a converging channel rheometer. J. Nonnewton. Fluid. Mech. 35, 445\u2013458 (1990).","journal-title":"J. Nonnewton. Fluid. Mech."},{"key":"102_CR14","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1007\/s00348-007-0306-2","volume":"43","author":"M.N. Oliveira","year":"2007","unstructured":"Oliveira, M.N., Alves, M., Pinho, F. & McKinley, G. Viscous flow through microfabricated hyperbolic contractions. Exp. Fluids 43, 437\u2013451 (2007).","journal-title":"Exp. Fluids"},{"key":"102_CR15","doi-asserted-by":"crossref","first-page":"078305","DOI":"10.1103\/PhysRevLett.110.078305","volume":"110","author":"M. Brust","year":"2013","unstructured":"Brust, M. et al. Rheology of Human Blood Plasma: Viscoelastic Versus Newtonian Behavior. Phys. Rev. Lett. 110, 078305 (2013).","journal-title":"Phys. Rev. Lett."},{"key":"102_CR16","doi-asserted-by":"crossref","first-page":"652","DOI":"10.1016\/j.jnnfm.2010.03.005","volume":"165","author":"P.C. Sousa","year":"2010","unstructured":"Sousa, P.C., Pinho, F.T., Oliveira, M.S.N. & Alves, M.A. Efficient microfluidic rectifiers for viscoelastic fluid flow. J. Nonnewton. Fluid. Mech. 165, 652\u2013671 (2010).","journal-title":"J. Nonnewton. Fluid. Mech."},{"key":"102_CR17","volume-title":"Polytechnic Institute of Bragan\u00e7a","author":"A. Lopes","year":"2014","unstructured":"Lopes, A. The study of the effect of microcontractions in the separation of blood cells: soft lithography and micromilling. Polytechnic Institute of Bragan\u00e7a (2014)."},{"key":"102_CR18","doi-asserted-by":"crossref","first-page":"121","DOI":"10.3390\/mi6010121","volume":"6","author":"E. Pinto","year":"2015","unstructured":"Pinto, E. et al. A rapid and low-cost nonlithographic method to fabricate biomedical microdevices for blood flow analysis. Micromachines 6, 121\u2013135 (2015).","journal-title":"Micromachines"},{"key":"102_CR19","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1002\/cnm.2526","volume":"29","author":"D. Pinho","year":"2013","unstructured":"Pinho, D., Lima, R., Pereira, A.I. & Gayubo, F. Automatic tracking of labeled red blood cells in microchannels. Int. J. Numer. Method Biomed. Eng. 29, 977\u2013987 (2013).","journal-title":"Int. J. Numer. Method Biomed. Eng."}],"container-title":["BioChip Journal"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s13206-016-0102-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s13206-016-0102-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s13206-016-0102-2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,11]],"date-time":"2020-09-11T05:34:12Z","timestamp":1599802452000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s13206-016-0102-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11,12]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,3]]}},"alternative-id":["102"],"URL":"https:\/\/doi.org\/10.1007\/s13206-016-0102-2","relation":{},"ISSN":["1976-0280","2092-7843"],"issn-type":[{"value":"1976-0280","type":"print"},{"value":"2092-7843","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,11,12]]}}}