{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,17]],"date-time":"2026-01-17T23:16:04Z","timestamp":1768691764635,"version":"3.49.0"},"reference-count":138,"publisher":"Tsinghua University Press","issue":"4","license":[{"start":{"date-parts":[[2012,10,13]],"date-time":"2012-10-13T00:00:00Z","timestamp":1350086400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/2.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Photonic Sens"],"published-print":{"date-parts":[[2012,12]]},"DOI":"10.1007\/s13320-012-0090-3","type":"journal-article","created":{"date-parts":[[2012,10,17]],"date-time":"2012-10-17T16:12:29Z","timestamp":1350490349000},"page":"315-330","source":"Crossref","is-referenced-by-count":37,"title":["Fiber optic intensity-modulated sensors: a review in biomechanics"],"prefix":"10.26599","volume":"2","author":[{"given":"Paulo","family":"Roriz","sequence":"first","affiliation":[]},{"given":"Ant\u00f3nio","family":"Ramos","sequence":"additional","affiliation":[]},{"given":"Jos\u00e9 L.","family":"Santos","sequence":"additional","affiliation":[]},{"given":"Jos\u00e9 A.","family":"Sim\u00f5es","sequence":"additional","affiliation":[]}],"member":"11138","published-online":{"date-parts":[[2012,10,13]]},"reference":[{"issue":"12","key":"90_CR1","doi-asserted-by":"crossref","first-page":"1929","DOI":"10.1016\/j.jbiomech.2004.02.021","volume":"37","author":"A. Lees","year":"2004","unstructured":"A. Lees, J. Vanrenterghem, and D. D. Clercq, \u201cUnderstanding how an arm swing enhances performance in the vertical jump,\u201d Journal of Biomechanics, vol. 37, no. 12, pp. 1929\u20131940, 2004.","journal-title":"Journal of Biomechanics"},{"key":"90_CR2","doi-asserted-by":"crossref","first-page":"S166","DOI":"10.1016\/S0021-9290(06)83577-3","volume":"39sup.1","author":"N. Sakai","year":"2006","unstructured":"N. Sakai and S. Shimawaki, \u201cHand motion analysis during touch-typing using VICON system with finger force plate,\u201d Journal of Biomechanics, vol. 39, sup. 1, pp. S166, 2006.","journal-title":"Journal of Biomechanics"},{"issue":"1","key":"90_CR3","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.jbiomech.2005.11.007","volume":"40","author":"H. Liu","year":"2007","unstructured":"H. Liu, C. Holt, and S. Evans, \u201cAccuracy and repeatability of an optical motion analysis system for measuring small deformations of biological tissues,\u201d Journal of Biomechanics, vol. 40, no. 1, pp. 210\u2013214, 2007.","journal-title":"Journal of Biomechanics"},{"issue":"12","key":"90_CR4","doi-asserted-by":"crossref","first-page":"2776","DOI":"10.1016\/j.jbiomech.2008.06.024","volume":"41","author":"M. Windolf","year":"2008","unstructured":"M. Windolf, H., Germany, and M. Morlock, \u201cSystematic accuracy and precision analysis of video motion capturing systems \u2014 exemplified on the Vicon-460 system,\u201d Journal of Biomechanics, vol. 41, no. 12, pp. 2776\u20132780, 2008.","journal-title":"Journal of Biomechanics"},{"issue":"3","key":"90_CR5","doi-asserted-by":"crossref","first-page":"136","DOI":"10.3109\/03091908009161107","volume":"4","author":"R. P. Betts","year":"1980","unstructured":"R. P. Betts, T. Duckworth, I. G. Austin, S. P. Crocker, and S. Moore, \u201cCritical light reflection at a plastic\/glass interface and its application to foot pressure measurements,\u201d Journal of Medical Engineering and Technology, vol. 4, no. 3, pp. 136\u2013142, 1980.","journal-title":"Journal of Medical Engineering and Technology"},{"issue":"5","key":"90_CR6","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1007\/BF02442381","volume":"21","author":"C. I. Franks","year":"1983","unstructured":"C. I. Franks, R. P. Betts, and T. Duckworth, \u201cMicroprocessor-based image processing system for dynamic foot pressure studies,\u201d Medical and Biological Engineering and Computing, vol. 21, no. 5, pp. 566\u2013572, 1983.","journal-title":"Medical and Biological Engineering and Computing"},{"issue":"4","key":"90_CR7","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1016\/0141-5425(88)90071-4","volume":"10","author":"C. I. Franks","year":"1988","unstructured":"C. I. Franks and R. P. Betts, \u201cSelection of transducer material for use with\u2019 optical\u2019 foot pressure systems,\u201d Journal of Biomedical Engineering, vol. 10, no. 4, pp. 365\u2013367, 1988.","journal-title":"Journal of Biomedical Engineering"},{"issue":"3","key":"90_CR8","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1177\/107110070302400307","volume":"24","author":"A. Gefen","year":"2003","unstructured":"A. Gefen, \u201cThe in vivo elastic properties of the plantar fascia during the contact phase of walking,\u201d Foot and Ankle International, vol. 24, no. 3, pp. 238\u2013244, 2003.","journal-title":"Foot and Ankle International"},{"issue":"7","key":"90_CR9","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1016\/S0268-0033(00)00011-5","volume":"15","author":"J. E. Nelson","year":"2000","unstructured":"J. E. Nelson, D. E. Treaster, and W. S. Marras, \u201cFinger motion, wrist motion and tendon travel as a function of keyboard angles,\u201d Clinical Biomechanics, vol. 15, no. 7, pp. 489\u2013498, 2000.","journal-title":"Clinical Biomechanics"},{"issue":"10","key":"90_CR10","doi-asserted-by":"crossref","first-page":"1589","DOI":"10.1016\/j.jbiomech.2004.01.001","volume":"37","author":"D. L. Jindrich","year":"2004","unstructured":"D. L. Jindrich, A. D. Balakrishnan, and J. T. Dennerlein, \u201cFinger joint impedance during tapping on a computer keyswitch,\u201d Journal of Biomechanics, vol. 37, no. 10, pp. 1589\u20131596, 2004.","journal-title":"Journal of Biomechanics"},{"issue":"1","key":"90_CR11","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1186\/1471-2474-8-47","volume":"8","author":"G. Spahn","year":"2007","unstructured":"G. Spahn, H. Plettenberg, E. Kahl, Klinger, M. Hans, T. M. Kockley, and G. O. Hofmann, \u201cNear-infrared (NIR) spectroscopy. a new method for arthroscopic evaluation of low grade degenerated cartilage lesions. results of a pilot study,\u201d BMC Musculoskeletal Disorders, vol. 8, no. 1, pp. 47, 2007.","journal-title":"BMC Musculoskeletal Disorders"},{"issue":"1","key":"90_CR12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.pathophys.2009.04.001","volume":"17","author":"G. O. Hofmann","year":"2010","unstructured":"G. O. Hofmann, J. Marticke, R. Grossst\u00fcck, M. Hoffmann, M. Lange, H. K. Plettenberg, et al., \u201cDetection and evaluation of initial cartilage pathology in man: a comparison between MRT, arthroscopy and near-infrared spectroscopy (NIR) in their relation to initial knee pain,\u201d Pathophysiology, vol. 17, no. 1, pp. 1\u20138, 2010.","journal-title":"Pathophysiology"},{"issue":"12","key":"90_CR13","doi-asserted-by":"crossref","first-page":"2516","DOI":"10.1177\/0363546510376744","volume":"38","author":"G. Spahn","year":"2010","unstructured":"G. Spahn, H. M. Klinger, M. Baums, M. Hoffmann, H. Plettenberg, A. Kroker, et al., \u201cNear-infrared spectroscopy for arthroscopic evaluation of cartilage lesions: results of a blinded, prospective, interobserver study,\u201d The American Journal of Sports Medicine, vol. 38, no. 12, pp. 2516\u20132521, 2010.","journal-title":"The American Journal of Sports Medicine"},{"issue":"4","key":"90_CR14","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1016\/j.clinbiomech.2009.12.008","volume":"25","author":"J. K. Marticke","year":"2010","unstructured":"J. K. Marticke, A. H\u00f6sselbarth, K. L. Hoffmeier, I. Marintschev, S. Otto, M. Lange, H. K. Plettenberg, et al., \u201cHow do visual, spectroscopic and biomechanical changes of cartilage correlate in osteoarthritic knee joints,\u201d Clinical Biomechanics, vol. 25, no. 4, pp. 332\u2013340, 2010.","journal-title":"Clinical Biomechanics"},{"issue":"5","key":"90_CR15","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/S0009-9120(86)80037-6","volume":"19","author":"M. Thompson","year":"1986","unstructured":"M. Thompson and E. T. Vandenberg, \u201cIn vivo probes: problems and perspectives,\u201d Clinical Biochemistry, vol. 19, no. 5, pp. 255\u2013261, 1986.","journal-title":"Clinical Biochemistry"},{"issue":"4645","key":"90_CR16","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1126\/science.6422554","volume":"224","author":"J. Peterson","year":"1984","unstructured":"J. Peterson and G. Vurek, \u201cFiber-optic sensors for biomedical applications,\u201d Science, vol. 224, no. 4645, pp. 123\u2013127, 1984.","journal-title":"Science"},{"issue":"12","key":"90_CR17","doi-asserted-by":"crossref","first-page":"1469","DOI":"10.1080\/713821914","volume":"33","author":"D. A. Jackson","year":"1986","unstructured":"D. A. Jackson and J. D. C. Jones, \u201cFiber optic sensors,\u201d Optica Acta: International Journal of Optics, vol. 33, no. 12, pp. 1469\u20131503, 1986.","journal-title":"Optica Acta: International Journal of Optics"},{"key":"90_CR18","first-page":"496","volume-title":"Fiber optic sensors: an introduction for engineers and scientists","author":"E. Udd","year":"1991","unstructured":"E. Udd, Fiber optic sensors: an introduction for engineers and scientists. New York: John Wiley & Sons Inc., 1991, pp. 496."},{"issue":"8","key":"90_CR19","doi-asserted-by":"crossref","first-page":"4015","DOI":"10.1063\/1.1145411","volume":"66","author":"E. Udd","year":"1995","unstructured":"E. Udd, \u201cAn overview of fiber-optic sensors,\u201d Review of Scientific Instruments, vol. 66, no. 8, pp. 4015\u20134030, 1995.","journal-title":"Review of Scientific Instruments"},{"key":"90_CR20","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1038\/173039b0","volume":"173","author":"H. H. Hopkins","year":"1954","unstructured":"H. H. Hopkins and N. S. Kapany, \u201cA flexible fiberscope, using static scanning,\u201d Nature, vol. 173, pp. 39\u201341, 1954.","journal-title":"Nature"},{"key":"90_CR21","first-page":"509","volume-title":"Fiber optic sensors","author":"F. T. S. Yu","year":"2002","unstructured":"F. T. S. Yu and Y. Shizhuo, Fiber optic sensors, New York: Marcel Dekker Inc., 2002, pp. 509."},{"issue":"4","key":"90_CR22","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1063\/1.1716990","volume":"31","author":"M. L. Polanyi","year":"1960","unstructured":"M. L. Polanyi and R. M. Hehir, \u201cNew reflection oximeter,\u201d Review of Scientific Instruments, vol. 31, no. 4, pp. 401\u2013403, 1960.","journal-title":"Review of Scientific Instruments"},{"issue":"10","key":"90_CR23","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1063\/1.1717679","volume":"33","author":"M. L. Polanyi","year":"1962","unstructured":"M. L. Polanyi and R. M. Hehir, \u201cIn vivo oximeter with fast dynamic response,\u201d Review of Scientific Instruments, vol. 33, no. 10, pp. 1050\u20131054, 1962.","journal-title":"Review of Scientific Instruments"},{"key":"90_CR24","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1016\/S0022-5223(19)32555-3","volume":"42","author":"P. F. Ware","year":"1961","unstructured":"P. F. Ware, M. L. Polanyi, R. M. Hehir, J. F. Stapleton, J. I. Sanders, and S. L. Kocot, \u201cA new reflection oximeter,\u201d The Journal of Thoracic and Cardiovascular Surgery, vol. 42, pp. 580\u2013588, 1961.","journal-title":"The Journal of Thoracic and Cardiovascular Surgery"},{"issue":"3","key":"90_CR25","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1152\/jappl.1953.6.3.189","volume":"6","author":"L. C. Clark","year":"1953","unstructured":"L. C. Clark, R. Wolf, D. Grager, and Z. Taylor, \u201cContinuous recording of blood oxygen tensions by polarography,\u201d Journal of Applied Physiology, vol. 6, no. 3, pp. 189\u2013193, 1953.","journal-title":"Journal of Applied Physiology"},{"issue":"3","key":"90_CR26","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1152\/jappl.1962.17.3.552","volume":"17","author":"Y. Enson","year":"1962","unstructured":"Y. Enson, W. A. Briscoe, M. L. Polanyi, and A. Cournand, \u201cIn vivo studies with an intravascular and intracardiac reflection oximeter,\u201d Journal of Applied Physiology, vol. 17, no. 3, pp. 552\u2013558, 1962.","journal-title":"Journal of Applied Physiology"},{"issue":"4","key":"90_CR27","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1161\/01.CIR.29.4.499","volume":"29","author":"Y. Enson","year":"1964","unstructured":"Y. Enson, A. G. Jameson, and A. Cournan, \u201cIntracardiac oximetry in congenital heart disease,\u201d Circulation, vol. 29, no. 4, pp. 499\u2013507, 1964.","journal-title":"Circulation"},{"issue":"3","key":"90_CR28","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1161\/01.CIR.31.3.328","volume":"31","author":"W. J. Gamble","year":"1965","unstructured":"W. J. Gamble, P. G. Hugenholtz, R. G. Monroe, M. Polanyi, and A. S. Nadas, \u201cThe use of fiberoptics in clinical cardiac catheterization: I. intracardiac oximetry,\u201d Circulation, vol. 31, no. 3, pp. 328\u2013343, 1965.","journal-title":"Circulation"},{"issue":"3","key":"90_CR29","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1161\/01.CIR.31.3.344","volume":"31","author":"P. G. Hugenholtz","year":"1965","unstructured":"P. G. Hugenholtz, W. J. Gamble, R. G. Monroe, and M. Polanyi, \u201cThe use of fiberoptics in clinical cardiac catheterization: II. in vivo dye-dilution curves,\u201d Circulation, vol. 31, no. 3, pp. 344\u2013355, 1965.","journal-title":"Circulation"},{"issue":"6","key":"90_CR30","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1016\/0002-9149(65)90356-5","volume":"15","author":"P. L. Frommer","year":"1965","unstructured":"P. L. Frommer, J. Ross, D. T. Mason, J. H. Gault, and E. Braunwald, \u201cClinical applications of an improved, rapidly responding fiberoptic catheter,\u201d The American Journal of Cardiology, vol. 15, no. 6, pp. 672\u2013679, 1965.","journal-title":"The American Journal of Cardiology"},{"issue":"6","key":"90_CR31","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1016\/0002-8703(66)90597-7","volume":"71","author":"D. C. Harrison","year":"1966","unstructured":"D. C. Harrison, N. S. Kapany, H. A. Miller, N. Silbertrust, W. L. Henry, and R. P. Drake, \u201cFiber optics for continuous in vivo monitoring of oxygen saturation,\u201d American Heart Journal, vol. 71, no. 6, pp. 766\u2013774, 1966.","journal-title":"American Heart Journal"},{"issue":"5","key":"90_CR32","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1152\/jappl.1967.23.5.641","volume":"23","author":"B. McCarthy","year":"1967","unstructured":"B. McCarthy, W. B. Hood, and B. Lown, \u201cFiberoptic monitoring of cardiac output and hepatic dye clearance in dogs,\u201d Journal of Applied Physiology, vol. 23, no. 5, pp. 641\u2013645, 1967.","journal-title":"Journal of Applied Physiology"},{"issue":"2","key":"90_CR33","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1093\/cvr\/2.2.199","volume":"2","author":"G. A. Mook","year":"1968","unstructured":"G. A. Mook, P. Osypka, R. E. Sturm, and E. H. Wood, \u201cFiber optic reflection photometry on blood,\u201d Cardiovascular Research, vol. 2, no. 2, pp. 199\u2013209, 1968.","journal-title":"Cardiovascular Research"},{"issue":"1","key":"90_CR34","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/0002-9149(69)90054-X","volume":"24","author":"P. G. Hugenholtz","year":"1969","unstructured":"P. G. Hugenholtz, H. R. Wagner, and R. C. Ellison, \u201cApplication of fiberoptic dye-dilution technic to the assessment of myocardial function. I. description of technic and results in 100 patients with congenital or acquired heart disease,\u201d The American Journal of Cardiology, vol. 24, no. 1, pp. 79\u201394, 1969.","journal-title":"The American Journal of Cardiology"},{"issue":"5","key":"90_CR35","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1016\/0002-9149(70)90597-7","volume":"25","author":"R. Singh","year":"1970","unstructured":"R. Singh, A. J. Ranieri, H. R. Vest, D. L. Bowers, and J. F. Dammann, \u201cSimultaneous determinations of cardiac output by thermal dilution, fiberoptic and dye-dilution methods,\u201d The American Journal of Cardiology, vol. 25, no. 5, pp. 579\u2013587, 1970.","journal-title":"The American Journal of Cardiology"},{"key":"90_CR36","unstructured":"F. Clark, E. Schmidt, and R. DeLaCroix, \u201cFiber optic blood pressure catheter with frequency response from DC into the audio range,\u201d in Proceedings of the Natiotnal Electronics Conference, McCormick Place, Chicago, Illinois, USA, Oct. 25\u201327, pp. 213\u2013216, 1965."},{"issue":"3","key":"90_CR37","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1007\/BF02474776","volume":"7","author":"A. Lekholm","year":"1969","unstructured":"A. Lekholm and L. H. Lindstr\u00f6m, \u201cOptoelectronic transducer for intravascular measurements of pressure variations,\u201d Medical and Biological Engineering and Computing, vol. 7, no. 3, pp. 333\u2013335, 1969.","journal-title":"Medical and Biological Engineering and Computing"},{"issue":"5","key":"90_CR38","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1152\/jappl.1969.26.5.679","volume":"26","author":"A. Ramirez","year":"1969","unstructured":"A. Ramirez, W. B. Hood, M. Polanyi, R. Wagner, N. A. Yankopoulos, and W. H. Abelmann, \u201cRegistration of intravascular pressure and sound by a fiberoptic catheter,\u201d Journal of Applied Physiology, vol. 26, no. 5, pp. 679\u2013683, 1969.","journal-title":"Journal of Applied Physiology"},{"issue":"3","key":"90_CR39","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1109\/TBME.1970.4502735","volume":"17","author":"L. H. Lindstr\u00f6m","year":"1970","unstructured":"L. H. Lindstr\u00f6m, \u201cMiniaturized pressure transducer intended for intravascular use,\u201d IEEE Transactions on Biomedical Engineering, vol. 17, no. 3, pp. 207\u2013219, 1970.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"issue":"6","key":"90_CR40","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1172\/JCI100910","volume":"16","author":"G. E. Burch","year":"1937","unstructured":"G. E. Burch and W. A. Sodeman, \u201cThe estimation of the subcutaneous tissue pressure by a direct method,\u201d The Journal of Clinical Investigation, vol. 16, no. 6, pp. 845\u2013850, 1937.","journal-title":"The Journal of Clinical Investigation"},{"key":"90_CR41","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1016\/S0021-9290(02)00321-4","volume":"362","author":"K. R. Kaufman","year":"2003","unstructured":"K. R. Kaufman, T. Waveringb, D. Morrowa, J. Davisc, and R. L. Lieberc, \u201cPerformance characteristics of a pressure microsensor,\u201d Journal of Biomechanics, vol. 36, no.2, pp. 283\u2013287, 2003.","journal-title":"Journal of Biomechanics"},{"key":"90_CR42","unstructured":"E. K. Franke, \u201cMiniature pressure gauge for the measurement of intravascular blood pressure,\u201d US Patent 3215135, Nov. 12, 1965."},{"key":"90_CR43","unstructured":"W. E. Frank, \u201cDetection and measurement device having a small flexible fiber transmission line,\u201d US Patent 3273447, Sept. 20, 1966."},{"key":"90_CR44","unstructured":"E. G. Valliere, \u201cOptical catheter means,\u201d US Patent 3267932, Aug. 23, 1966."},{"issue":"1","key":"90_CR45","first-page":"36","volume":"10","author":"S. Morikawa","year":"1972","unstructured":"S. Morikawa, \u201cFiberoptic catheter-tip pressure transducer,\u201d Japanese Journal of Medical Electronics and Biological Engineering, vol. 10, no. 1, pp. 36\u201339, 1972.","journal-title":"Japanese Journal of Medical Electronics and Biological Engineering"},{"issue":"7","key":"90_CR46","first-page":"465","volume":"15","author":"K. Kobayashi","year":"1977","unstructured":"K. Kobayashi, H. Okuyama, T. Kato, and T. Yasuda, \u201cFiberoptic catheter-tip micromanometer,\u201d Japanese Journal of Medical Electronics and Biological Engineering, vol. 15, no. 7, pp. 465\u2013472, 1977.","journal-title":"Japanese Journal of Medical Electronics and Biological Engineering"},{"issue":"7","key":"90_CR47","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1001\/jama.1972.03200200017005","volume":"221","author":"J. B. Taylor","year":"1972","unstructured":"J. B. Taylor, B. Lown, and M. Polanyi, \u201cIn vivo monitoring with a fiber optic catheter,\u201d The Journal of the American Medical Association (JAMA), vol. 221, no. 7, pp. 667\u2013673, 1972.","journal-title":"The Journal of the American Medical Association (JAMA)"},{"issue":"5","key":"90_CR48","doi-asserted-by":"crossref","first-page":"239","DOI":"10.3109\/03091907809161807","volume":"2","author":"H. Matsumoto","year":"1978","unstructured":"H. Matsumoto, M. Saegusa, K. Saito, and K. Mizoi, \u201cThe development of a fiber optic catheter tip pressure transducer,\u201d Journal of Medical Engineering and Technology, vol. 2, no. 5, pp. 239\u2013242, 1978.","journal-title":"Journal of Medical Engineering and Technology"},{"key":"90_CR49","doi-asserted-by":"crossref","unstructured":"L. Tenerz, L. Smith, and B. Hok, \u201cA fiberoptic silicon pressure microsensor for measurements in coronary arteries,\u201d in IEEE International Conference Solid-State Sensor Actuator, San Francisco, California, USA, Jun. 24\u201327, pp. 1021\u20131023, 1991.","DOI":"10.1109\/SENSOR.1991.149068"},{"issue":"1\u20133","key":"90_CR50","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1016\/S0924-4247(97)80026-X","volume":"54","author":"O. Tohyama","year":"1996","unstructured":"O. Tohyama, M. Kohashi, K. Yamamoto, and H. Itoh, \u201cA fiber-optic silicon pressure sensor for ultra-thin catheters,\u201d Sensors and Actuators A: Physical, vol. 54, no. 1\u20133, pp. 622\u2013625, 1996.","journal-title":"Sensors and Actuators A: Physical"},{"issue":"1","key":"90_CR51","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/S0924-4247(97)80430-X","volume":"63","author":"C. Strandman","year":"1997","unstructured":"C. Strandman, L. Smith, L. Tenerz, and B. H\u00f6k, \u201cA production process of silicon sensor elements for a fiber-optic pressure sensor,\u201d Sensors and Actuators A: Physical, vol. 63, no. 1, pp. 69\u201374, 1997.","journal-title":"Sensors and Actuators A: Physical"},{"issue":"1\u20133","key":"90_CR52","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/S0924-4247(97)01764-0","volume":"66","author":"O. Tohyama","year":"1998","unstructured":"O. Tohyama, M. Kohashi, M. Fukui, and H. Itoh, \u201cA fiber-optic pressure microsensor for biomedical applications,\u201d Sensors and Actuators A: Physical, vol. 66, no. 1\u20133, pp. 150\u2013154, 1998.","journal-title":"Sensors and Actuators A: Physical"},{"key":"90_CR53","doi-asserted-by":"crossref","unstructured":"E. Kalvesten, L. Smith, L. Tenerz, and G. Stemme, \u201cThe first surface micromachined pressure sensor for cardiovascular pressure measurements,\u201d in Proceedings \u2014 The Eleventh Annual International Workshop on Micro Electro Mechanical Systems, 1998, MEMS 98, Heidelberg, Germany, Jan. 25\u201329, pp. 574\u2013579, 1998.","DOI":"10.1109\/MEMSYS.1998.659821"},{"issue":"6","key":"90_CR54","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1542\/peds.54.6.786","volume":"54","author":"F. Epstein","year":"1974","unstructured":"F. Epstein, A. Wald, and G. M. Hochwald, \u201cIntracranial pressure during compressive head wrapping in treatment of neonatal hydrocephalus,\u201d Pediatrics, vol. 54, no. 6, pp. 786\u2013790, 1974.","journal-title":"Pediatrics"},{"issue":"6","key":"90_CR55","first-page":"352","volume":"11","author":"A. Wald","year":"1977","unstructured":"A. Wald, K. Post, J. Ransohoff, W. Hass, and F. Epstein, \u201cA new technique for monitoring epidural intracranial pressure,\u201d Medical Instrumentation, vol. 11, no. 6, pp. 352\u2013354, 1977.","journal-title":"Medical Instrumentation"},{"issue":"4","key":"90_CR56","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1097\/00004669-197810000-00013","volume":"3","author":"A. Wald","year":"1978","unstructured":"A. Wald, \u201cMonitoring intracranial pressure,\u201d Journal of Clinical Engineering, vol. 3, no. 4, pp. 383\u2013388, 1978.","journal-title":"Journal of Clinical Engineering"},{"issue":"6","key":"90_CR57","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1542\/peds.59.6.957","volume":"59","author":"D. Vidyasagar","year":"1977","unstructured":"D. Vidyasagar and T. N. K. Raju, \u201cA simple noninvasive technique of measuring intracranial pressure in the newborn,\u201d Pediatrics, vol. 59, no. 6, pp. 957\u2013961, 1977.","journal-title":"Pediatrics"},{"issue":"6","key":"90_CR58","doi-asserted-by":"crossref","first-page":"996","DOI":"10.1542\/peds.62.6.996","volume":"62","author":"D. Vidyasagar","year":"1978","unstructured":"D. Vidyasagar, T. N. Raju, and J. Chiang, \u201cClinical significance of monitoring anterior fontanel pressure in sick neonates and infants,\u201d Pediatrics, vol. 62, no. 6, pp. 996\u2013999, 1978.","journal-title":"Pediatrics"},{"key":"90_CR59","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1203\/00006450-197804001-01138","volume":"12","author":"P. R. Holbrook","year":"1978","unstructured":"P. R. Holbrook, \u201c1132 noninvasive measurement of intracranial pressure: evaluation of a technique,\u201d Pediatric Research, vol. 12, pp. 552, 1978.","journal-title":"Pediatric Research"},{"issue":"4","key":"90_CR60","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1136\/jnnp.36.4.514","volume":"36","author":"N. J. Coroneos","year":"1973","unstructured":"N. J. Coroneos, D. G. McDowall, R. M. Gibson, V. W. Pickerodt, and N. P. Keaney, \u201cMeasurement of extradural pressure and its relationship to other intracranial pressures: an experimental and clinical study,\u201d Journal of Neurology, Neurosurgery & Psychiatry, vol. 36, no. 4, pp. 514\u2013522, 1973.","journal-title":"Journal of Neurology, Neurosurgery & Psychiatry"},{"key":"90_CR61","unstructured":"INTEGRA. (2010, 10 Dec). Directions for use: OLM Intracranial pressure monitoring kit Model 110-4B. Available: http:\/\/integralife.com\/products\/PDFs\/Camino\/110-4B.pdf ."},{"key":"90_CR62","unstructured":"D. B. Keck, \u201cOptoelectronics in Japan and the United States,\u201d Japanese Technology Evaluation Center (JTEC), Baltimore, Maryland, USA, February, 1996."},{"issue":"3","key":"90_CR63","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1002\/jor.1100080318","volume":"8","author":"A. G. Crenshaw","year":"1990","unstructured":"A. G. Crenshaw, J. R. Styf, S. J. Mubarak, and A. R. Hargens, \u201cA new transducer-tipped fiber optic catheter for measuring intramuscular pressures,\u201d Journal of Orthopaedic Research, vol. 8, no. 3, pp. 464\u2013468, 1990.","journal-title":"Journal of Orthopaedic Research"},{"issue":"2","key":"90_CR64","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1007\/BF00705077","volume":"65","author":"A. G. Crenshaw","year":"1992","unstructured":"A. G. Crenshaw, J. R. Styf, and A. R. Hargens, \u201cIntramuscular pressures during exercise: an evaluation of a fiber optic transducer-tipped catheter system,\u201d European Journal of Applied Physiology, vol. 65, no. 2, pp. 178\u2013182, 1992.","journal-title":"European Journal of Applied Physiology"},{"issue":"3","key":"90_CR65","doi-asserted-by":"crossref","first-page":"377","DOI":"10.3109\/17453679308993649","volume":"64","author":"M. Nakhostine","year":"1993","unstructured":"M. Nakhostine, J. R. Styf, S. V. Leuven, A. R Hargens, and D. H. Gershuni, \u201cIntramuscular pressure varies with depth: the tibialis anterior muscle studied in 12 volunteers,\u201d Acta Orthopaedica, vol. 64, no. 3, pp. 377\u2013381, 1993.","journal-title":"Acta Orthopaedica"},{"issue":"8","key":"90_CR66","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.1002\/bjs.1800810814","volume":"81","author":"P. Peters","year":"1994","unstructured":"P. Peters, S. R. Baker, P. W. Leopold, N. A. Taub, and K. G. Burnand, \u201cCompartment syndrome following prolonged pelvic surgery,\u201d British Journal of Surgery, vol. 81, no. 8, pp. 1128\u20131131, 1994.","journal-title":"British Journal of Surgery"},{"issue":"4","key":"90_CR67","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/S1060-1872(95)80024-7","volume":"3","author":"K. R. Kaufman","year":"1995","unstructured":"K. R. Kaufman and D. H. Sutherland, \u201cDynamic intramuscular pressure measurement during gait,\u201d Operative Techniques in Sports Medicine, vol. 3, no. 4, pp. 250\u2013255, 1995.","journal-title":"Operative Techniques in Sports Medicine"},{"issue":"4","key":"90_CR68","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1002\/jor.1100070410","volume":"7","author":"R. A. Pedowitz","year":"1989","unstructured":"R. A. Pedowitz, D. H. Gershuni, A. G. Crenshaw, S. L. Petras, L. A. Danzig, and A. R. Hargens, \u201cIntraarticular pressure during continuous passive motion of the human knee,\u201d Journal of Orthopaedic Research, vol. 7, no. 4, pp. 530\u2013537, 1989.","journal-title":"Journal of Orthopaedic Research"},{"issue":"2","key":"90_CR69","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/S1058-2746(97)90035-5","volume":"6","author":"W. Inokuchi","year":"1997","unstructured":"W. Inokuchi, O. B. Sanderhoff, J. O. S\u00f8jbjerg, and O. Sneppen, \u201cThe relation between the position of the glenohumeral joint and the intraarticular pressure: an experimental study,\u201d Journal of Shoulder and Elbow Surgery, vol. 6, no. 2, pp. 144\u2013149, 1997.","journal-title":"Journal of Shoulder and Elbow Surgery"},{"issue":"4-5","key":"90_CR70","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/S0268-0033(98)00092-8","volume":"13","author":"C. M. Sommerich","year":"1998","unstructured":"C. M. Sommerich, W. S. Marras, and M. Parnianpour, \u201cA method for developing biomechanical profiles of hand-intensive tasks,\u201d Clinical Biomechanics, vol. 13, no. 4-5, pp. 261\u2013271, 1998.","journal-title":"Clinical Biomechanics"},{"issue":"4","key":"90_CR71","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1016\/j.jhsa.2006.01.009","volume":"31","author":"K. Iba","year":"2006","unstructured":"K. Iba, T. Wada, M. Aoki, H. Tsuji, T. Oda, and T. Yamashita, \u201cIntraoperative measurement of pressure adjacent to the ulnar nerve in patients with cubital tunnel syndrome,\u201d Journal of Hand Surgery-American, vol. 31, no. 4, pp. 553\u2013558, 2006.","journal-title":"Journal of Hand Surgery-American"},{"issue":"4","key":"90_CR72","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1016\/j.jse.2007.12.003","volume":"17","author":"K. Iba","year":"2008","unstructured":"K. Iba, T. Wada, M. Aoki, H. Tsuji, T. Oda, Y. Ozasa, et al., \u201cThe relationship between the pressure adjacent to the ulnar nerve and the disease causing cubital tunnel syndrome,\u201d Journal of Shoulder and Elbow Surgery, vol. 17, no. 4, pp. 585\u2013588, 2008.","journal-title":"Journal of Shoulder and Elbow Surgery"},{"key":"90_CR73","unstructured":"R. K. Narayan, R. S. Bray, C. S. Robertson, L. Gokaslan, and R. G. Grossman, \u201cExperience with a new fiberoptic device for intracranial pressure monitoring,\u201d presented at the 55th Annual Meeting American Association Neurological Surgeons, Dallas, Texas, May 3\u20137, 1987."},{"issue":"3","key":"90_CR74","doi-asserted-by":"crossref","first-page":"482","DOI":"10.3171\/jns.1990.72.3.0482","volume":"72","author":"J. S. Crutchfield","year":"1990","unstructured":"J. S. Crutchfield, R. K. Narayan, C. S. Robertson, and L. H. Michael, \u201cEvaluation of a fiberoptic intracranial pressure monitor,\u201d Journal of Neurosurgery, vol. 72, no. 3, pp. 482\u2013487, 1990.","journal-title":"Journal of Neurosurgery"},{"issue":"3","key":"90_CR75","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1227\/00006123-199211000-00014","volume":"31","author":"G. Gambardella","year":"1992","unstructured":"G. Gambardella, D. d\u2019Avella, and F. Tomasello, \u201cMonitoring of brain tissue pressure with a fiberoptic device,\u201d Neurosurgery, vol. 31, no. 3, pp. 918\u2013922, 1992.","journal-title":"Neurosurgery"},{"issue":"3","key":"90_CR76","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1007\/BF01617024","volume":"9","author":"J. S. Yablon","year":"1993","unstructured":"J. S. Yablon, H. J. Lantner, T. M. McCormack, S. Nair, E. Barker, and P. Black, \u201cClinical experience with a fiberoptic intracranial pressure monitor,\u201d Journal of Clinical Monitoring and Computing, vol. 9, no. 3, pp. 171\u2013175, 1993.","journal-title":"Journal of Clinical Monitoring and Computing"},{"issue":"1","key":"90_CR77","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1097\/00006123-199601000-00053","volume":"38","author":"M. Czosnyka","year":"1996","unstructured":"M. Czosnyka, Z. Czosnyka, and J. Pickard, \u201cLaboratory testing of three intracranial pressure microtransducers: technical report,\u201d Neurosurgery, vol. 38, no. 1, pp. 219\u2013224, 1996.","journal-title":"Neurosurgery"},{"key":"90_CR78","unstructured":"P. H. Raboel, J. Bartek, M. Andresen, B. M. Bellander, and B. Romner, \u201cIntracranial pressure monitoring: invasive versus non-invasive methods: a review,\u201d Critical Care Research and Practice, vol. 2012, Article ID 950393 (14 pages), 2012."},{"issue":"2","key":"90_CR79","first-page":"111","volume":"17","author":"P. Hollingsworth-Fridlund","year":"1988","unstructured":"P. Hollingsworth-Fridlund, H. Vos, and E. K. Daily, \u201cUse of fiber-optic pressure transducer for intracranial pressure measurements: a preliminary report,\u201d Heart and Lung, vol. 17, no. 2, pp. 111\u2013120, 1988.","journal-title":"Heart and Lung"},{"issue":"10","key":"90_CR80","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1007\/BF01700971","volume":"21","author":"N. Bruder","year":"1995","unstructured":"N. Bruder, P. N\u2019Zoghe, N. Graziani, D. Pelissier, F. Grisoli, and G. Fran\u00e7ois, \u201cA comparison of extradural and intraparenchymatous intracranial pressures in head injured patients,\u201d Intensive Care Medicine, vol. 21, no. 10, pp. 850\u2013852, 1995.","journal-title":"Intensive Care Medicine"},{"issue":"11","key":"90_CR81","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1007\/s007010050224","volume":"140","author":"E. M\u00fcnch","year":"1998","unstructured":"E. M\u00fcnch, R. Weigel, P. Schmiedek, and L. Sch\u00fcrer, \u201cThe CAMINO intracranial pressure device in clinical practice: reliability, handling characteristics and complications,\u201d Acta Neurochirurgica, vol. 140, no. 11, pp. 1113\u20131120, 1998.","journal-title":"Acta Neurochirurgica"},{"issue":"1","key":"90_CR82","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1136\/jnnp.69.1.82","volume":"69","author":"R. Martinez-Manas","year":"2000","unstructured":"R. Martinez-Manas, D. Santamarta, J. M. de Campos, and E. Ferrer, \u201cCamino\u00ae intracranial pressure monitor: prospective study of accuracy and complications,\u201d Journal of Neurology, Neurosurgery & Psychiatry, vol. 69, no. 1, pp. 82\u201386, 2000.","journal-title":"Journal of Neurology, Neurosurgery & Psychiatry"},{"issue":"5","key":"90_CR83","first-page":"1158","volume":"49","author":"I. Piper","year":"2001","unstructured":"I. Piper, A. Barnes, D. Smith, and L. Dunn, \u201cThe Camino intracranial pressure sensor: is it optimal technology? an internal audit with a review of current intracranial pressure monitoring technologies,\u201d Neurosurgery, vol. 49, no. 5, pp. 1158\u20131165, 2001.","journal-title":"Neurosurgery"},{"issue":"3","key":"90_CR84","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1007\/s00701-002-1052-0","volume":"145","author":"R. Stendel","year":"2003","unstructured":"R. Stendel, J. Heidenreich, A. Schilling, R. Akhavan-Sigari, R. Kurth, T. Picht, et al., \u201cClinical evaluation of a new intracranial pressure monitoring device,\u201d Acta Neurochirurgica, vol. 145, no. 3, pp. 185\u2013193, 2003.","journal-title":"Acta Neurochirurgica"},{"issue":"4","key":"90_CR85","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1007\/s00701-005-0683-3","volume":"148","author":"M. Gelabert-Gonzalez","year":"2006","unstructured":"M. Gelabert-Gonzalez, V. Ginesta-Galan, R. Sernamito-Garc\u00eda, A. G. Allut, J. Bandin-Di\u00e9guez, and R. M. Rumbo, \u201cThe Camino intracranial pressure device in clinical practice. assessment in a 1000 cases,\u201d Acta Neurochirurgica, vol. 148, no. 4, pp. 435\u2013441, 2006.","journal-title":"Acta Neurochirurgica"},{"issue":"1","key":"90_CR86","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1213\/01.ane.0000297296.52006.8e","volume":"106","author":"M. Smith","year":"2008","unstructured":"M. Smith, \u201cMonitoring intracranial pressure in traumatic brain injury,\u201d Anesthesia and Analgesia, vol. 106, no. 1, pp. 240\u2013248, 2008.","journal-title":"Anesthesia and Analgesia"},{"issue":"1","key":"90_CR87","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.medengphy.2007.01.005","volume":"30","author":"P. K. Eide","year":"2008","unstructured":"P. K. Eide, \u201cComparison of simultaneous continuous intracranial pressure (ICP) signals from ICP sensors placed within the brain parenchyma and the epidural space,\u201d Medical Engineering and Physics, vol. 30, no. 1, pp. 34\u201340, 2008.","journal-title":"Medical Engineering and Physics"},{"issue":"2","key":"90_CR88","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.jocn.2008.02.008","volume":"16","author":"A. Bekar","year":"2009","unstructured":"A. Bekar, S. Do\u011fan, F. Abas, B. Caner, G. Korfali, H. Kocaeli, et al., \u201cRisk factors and complications of intracranial pressure monitoring with a fiberoptic device,\u201d Journal of Clinical Neuroscience, vol. 16, no. 2, pp. 236\u2013240, 2009.","journal-title":"Journal of Clinical Neuroscience"},{"issue":"10","key":"90_CR89","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1109\/10.88443","volume":"38","author":"R. A. Wolthuis","year":"1991","unstructured":"R. A. Wolthuis, G. L. Mitchell, E. Saaski, J. C. Hartl, and M. A. Afromowitz, \u201cDevelopment of medical pressure and temperature sensors employing optical spectrum modulation,\u201d IEEE Transactions on Biomedical Engineering, vol. 38, no. 10, pp. 974\u2013981, 1991.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"issue":"1","key":"90_CR90","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1088\/0960-1317\/15\/1\/011","volume":"15","author":"K. Totsu","year":"2005","unstructured":"K. Totsu, Y. Haga, and M. Esashi, \u201cUltra-miniature fiber-optic pressure sensor using white light interferometry,\u201d Journal of Micromechanics and Microengineering, vol. 15, no. 1, pp. 71\u201375, 2005.","journal-title":"Journal of Micromechanics and Microengineering"},{"key":"90_CR91","doi-asserted-by":"crossref","unstructured":"P. Polygerinos, T. Schaeffter, L. Seneviratne, and K. Althoefer, \u201cA fiber-optic catheter-tip force sensor with MRI compatibility: a feasibility study,\u201d in Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2009), Minneapolis, Minnesota, Sept. 3\u20136, pp. 1501\u20131504, 2009.","DOI":"10.1109\/IEMBS.2009.5334163"},{"key":"90_CR92","doi-asserted-by":"crossref","unstructured":"P. Polygerinos, T. Schaeffter, L. Seneviratne, R. Razavi, and K. Althoefer, \u201cNovel miniature MRI-compatible fiber-optic force sensor for cardiac catheterization procedures,\u201d in IEEE International Conference on Robotics Automation (ICRA), Anchorage, Alaska, USA, May 3\u20137, pp. 2598\u20132603, 2010.","DOI":"10.1109\/ROBOT.2010.5509416"},{"issue":"3","key":"90_CR93","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1121\/1.383957","volume":"67","author":"J. N. Fields","year":"1980","unstructured":"J. N. Fields, C. K. Asawa, O. G. Ramer, and M. K. Barnoski, \u201cFiber optic pressure sensor,\u201d Journal of the Acoustical Society of America, vol. 67, no. 3, pp. 816\u2013818, 1980.","journal-title":"Journal of the Acoustical Society of America"},{"issue":"5","key":"90_CR94","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1109\/JLT.1984.1073659","volume":"2","author":"H. F. Taylor","year":"1984","unstructured":"H. F. Taylor, \u201cBending effects in optical fibers,\u201d Journal of Lightwave Technology, vol. 2, no. 5, pp. 617\u2013628, 1984.","journal-title":"Journal of Lightwave Technology"},{"key":"90_CR95","first-page":"205","volume-title":"Optoelectronics: Devices and Applications","author":"S. Silvestri","year":"2011","unstructured":"S. Silvestri and E. Schena, \u201cOptical-fiber measurement systems for medical applications,\u201d in Optoelectronics: Devices and Applications. P. Predeep, Ed. Rijeka, Croatia: InTech, pp. 205\u2013224, 2011."},{"key":"90_CR96","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1117\/12.201239","volume":"2331","author":"H. K. Kopola","year":"1995","unstructured":"H. K. Kopola, O. Mantyla, M. Makiniemi, K. Mahonen, and K. Virtanen, \u201cInstrument for measuring human biting force,\u201d in Proc. SPIE, vol. 2331, pp. 149\u2013155, 1995.","journal-title":"Proc. SPIE"},{"issue":"3","key":"90_CR97","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1007\/BF00838652","volume":"72","author":"P. V. Komi","year":"1996","unstructured":"P. V. Komi, A. Belli, V. Huttunen, R. Bonnefoy, A. Geyssant, and J. R. Lacour, \u201cOptic fiber as a transducer of tendomuscular forces,\u201d European Journal of Applied Physiology and Occupational Physiology, vol. 72, no. 3, pp. 278\u2013280, 1996.","journal-title":"European Journal of Applied Physiology and Occupational Physiology"},{"issue":"7","key":"90_CR98","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1016\/S0268-0033(98)00032-1","volume":"13","author":"A. N. Arndt","year":"1998","unstructured":"A. N. Arndt, P. V. Komi, G. P. Br\u00fcggemann, and J. Lukkariniemi, \u201cIndividual muscle contributions to the in vivo Achilles tendon force,\u201d Clinical Biomechanics, vol. 13, no. 7, pp. 532\u2013541, 1998.","journal-title":"Clinical Biomechanics"},{"issue":"1","key":"90_CR99","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/17461390100071101","volume":"1","author":"T. Finni","year":"2001","unstructured":"T. Finni, S. Ikegaw, V. Lepola, and Paavo Komi, \u201cIn vivo behavior of vastus lateralis muscle during dynamic performances,\u201d European Journal of Sport Science, vol. 1, no. 1, pp. 1\u201313, 2001.","journal-title":"European Journal of Sport Science"},{"issue":"2","key":"90_CR100","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1152\/japplphysiol.00189.2005","volume":"99","author":"M. Ishikawa","year":"2005","unstructured":"M. Ishikawa, P. V. Komi, M. J. Grey, V. Lepola, and G. P. Bruggemann, \u201cMuscle-tendon interaction and elastic energy usage in human walking,\u201d Journal of Applied Physiology, vol. 99, no. 2, pp. 603\u2013608, 2005.","journal-title":"Journal of Applied Physiology"},{"key":"90_CR101","unstructured":"C. Nicol, P. V. Komi, A. Belli, V. Huttunen, and E. Partio, \u201cReflex contribution to Achilles tendon forces: in-vivo measurements with the optic fiber technique,\u201d presented at ISB XVth Congress, Jiv\u00e4skyl\u00e4, Finland, 1995."},{"issue":"3","key":"90_CR102","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1007\/s004210050335","volume":"77","author":"T. Finni","year":"1998","unstructured":"T. Finni, P. V. Komi, and J. Lukkariniemi, \u201cAchilles tendon loading during walking: application of a novel optic fiber technique,\u201d European Journal of Applied Physiology, vol. 77, no. 3, pp. 289\u2013291, 1998.","journal-title":"European Journal of Applied Physiology"},{"issue":"4\u20135","key":"90_CR103","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1007\/s004210000289","volume":"83","author":"T. Finni","year":"2000","unstructured":"T. Finni, P. V. Komi, and V. Lepola, \u201cIn vivo human triceps surae and quadriceps femoris muscle function in a squat jump and counter movement jump,\u201d European Journal of Applied Physiology, vol. 83, no. 4\u20135, pp. 416\u2013426,2000.","journal-title":"European Journal of Applied Physiology"},{"issue":"6","key":"90_CR104","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1016\/S0021-9290(02)00010-6","volume":"35","author":"A. Erdemir","year":"2002","unstructured":"A. Erdemir, S. J. Piazza, and N. A. Sharkey, \u201cInfluence of loading rate and cable migration on fiberoptic measurement of tendon force,\u201d Journal of Biomechanics, vol. 35, no. 6, pp. 857\u2013862, 2002.","journal-title":"Journal of Biomechanics"},{"issue":"2","key":"90_CR105","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/S0021-9290(98)00167-5","volume":"32","author":"G. W. Hall","year":"1999","unstructured":"G. W. Hall, J. R. Crandall, D. V. Carmines, and J. E. Hale, \u201cRate-independent characteristics of an arthroscopically implantable force probe in the human achilles tendon,\u201d Journal of Biomechanics, vol. 32, no. 2, pp. 203\u2013207, 1999.","journal-title":"Journal of Biomechanics"},{"issue":"3","key":"90_CR106","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1016\/S0021-9290(02)00414-1","volume":"36","author":"A. Erdemir","year":"2003","unstructured":"A. Erdemir, A. J. Hamel, S. J. Piazza, and N. A. Sharkey, \u201cFiberoptic measurement of tendon forces is influenced by skin movement artifact,\u201d Journal of Biomechanics, vol. 36, no. 3, pp. 449\u2013455, 2003.","journal-title":"Journal of Biomechanics"},{"issue":"2","key":"90_CR107","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1504\/IJMEI.2008.020747","volume":"1","author":"J. H. M\u00fcller","year":"2008","unstructured":"J. H. M\u00fcller, C. Scheffer, and A. Elvin, \u201cIn vivo detection of patellar tendon creep using a fiber-optic sensor,\u201d International Journal of Medical Engineering and Informatics, vol. 1, no. 2, pp. 155\u2013173, 2008.","journal-title":"International Journal of Medical Engineering and Informatics"},{"issue":"3","key":"90_CR108","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1023\/B:ABME.0000017542.75080.86","volume":"32","author":"B. C. Fleming","year":"2004","unstructured":"B. C. Fleming and B. D. Beynnon, \u201cIn vivo measurement of ligament\/tendon strains and forces: a review,\u201d Annals of Biomedical Engineering, vol. 32, no. 3, pp. 318\u2013328, 2004.","journal-title":"Annals of Biomedical Engineering"},{"key":"90_CR109","unstructured":"A. T. Augousti and A. Raza, \u201cThe development of a fiber-optic respiratory plethysmograph (FORP),\u201d in Sensors VI: Technology, Systems and Applications Proceedings of the sixth conference on Sensors and their Applications, Manchester, UK, Sept. 12\u201315, pp. 401\u2013406, 1993."},{"issue":"2","key":"90_CR110","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1088\/0031-9155\/42\/2\/002","volume":"42","author":"A. T. Augousti","year":"1997","unstructured":"A. T. Augousti, \u201cA theoretical study of the robustness of the isovolume calibration method for a two-compartment model of breathing, based on an analysis of the connected cylinders model,\u201d Physics in Medicine and Biology, vol. 42, no. 2, pp. 283\u2013291, 1997.","journal-title":"Physics in Medicine and Biology"},{"key":"90_CR111","doi-asserted-by":"crossref","unstructured":"A. T. Augousti, A. Raza, and M. Graves, \u201cDesign and characterization of a fiber optic respiratory plethysmograph (FORP),\u201d in Biomedical Sensing, Imaging, and Tracking Technologies I, San Jose, California, USA, Jan. 27, pp. 250\u2013257, 1996.","DOI":"10.1117\/12.238805"},{"issue":"5","key":"90_CR112","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1088\/0967-3334\/26\/5\/001","volume":"26","author":"A. T. Augousti","year":"2005","unstructured":"A. T. Augousti, F. X. Maletras, and J. Mason, \u201cImproved fiber optic respiratory monitoring using a figure-of-eight coil,\u201d Physiological Measurement, vol. 26, no. 5, pp. 585\u2013590, 2005.","journal-title":"Physiological Measurement"},{"issue":"4","key":"90_CR113","first-page":"214","volume":"20","author":"C. Davis","year":"1997","unstructured":"C. Davis, A. Mazzolini, and D. Murphy, \u201cA new fiber optic sensor for respiratory monitoring,\u201d Australasian Physical and Engineering Sciences in Medicine, vol. 20, no. 4, pp. 214\u2013219, 1997.","journal-title":"Australasian Physical and Engineering Sciences in Medicine"},{"issue":"9","key":"90_CR114","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1016\/S1350-4533(99)00094-6","volume":"21","author":"C. Davis","year":"1999","unstructured":"C. Davis, A. Mazzolini, J. Mills, and P. Dargaville, \u201cA new sensor for monitoring chest wall motion during high-frequency oscillatory ventilation,\u201d Medical Engineering and Physics, vol. 21, no. 9, pp. 619\u2013623, 1999.","journal-title":"Medical Engineering and Physics"},{"issue":"2","key":"90_CR115","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1117\/1.429909","volume":"4","author":"A. Babchenko","year":"1999","unstructured":"A. Babchenko, A. Babchenko, B. Khanokh, Y. Shomer, and M. Nitzan, \u201cFiber optic sensor for the measurement of respiratory chest circumference changes,\u201d Journal of Biomedical Optics, vol. 4, no. 2, pp. 224\u2013229, 1999.","journal-title":"Journal of Biomedical Optics"},{"issue":"1","key":"90_CR116","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1109\/38.250916","volume":"14","author":"D. J. Sturman","year":"1994","unstructured":"D. J. Sturman and D. Zeltzer, \u201cA survey of glove-based input,\u201d IEEE Computer Graphics and Applications, vol. 14, no. 1, pp. 30\u201339, 1994.","journal-title":"IEEE Computer Graphics and Applications"},{"issue":"1","key":"90_CR117","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/1743-0003-2-5","volume":"2","author":"L. Simone","year":"2005","unstructured":"L. Simone and D. Kamper, \u201cDesign considerations for a wearable monitor to measure finger posture,\u201d Journal of NeuroEngineering and Rehabilitation, vol. 2, no. 1, pp. 5, 2005.","journal-title":"Journal of NeuroEngineering and Rehabilitation"},{"key":"90_CR118","doi-asserted-by":"crossref","unstructured":"O. Portillo-Rodriguez, C. A. Avizzano, E. Sotgiu, S. Pabon, A. Frisoli, J. Ortiz, et al., \u201cA wireless bluetooth dataglove based on a novel goniometric sensors,\u201d in the 16th IEEE International Symposium on Robot and Human interactive Communication, 2007, RO-MAN 2007, Jeju, Korea, Aug. 26\u201329, pp. 1185\u20131190, 2007.","DOI":"10.1109\/ROMAN.2007.4415259"},{"issue":"4","key":"90_CR119","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1109\/TSMCC.2008.923862","volume":"38","author":"L. Dipietro","year":"2008","unstructured":"L. Dipietro, A. M. Sabatini, and P. Dario, \u201cA survey of glove-based systems and their applications,\u201d IEEE Transactions on Systems, Man, and Cybernetics, Part C: Applications and Reviews, vol. 38, no. 4, pp. 461\u2013482, 2008.","journal-title":"IEEE Transactions on Systems, Man, and Cybernetics, Part C: Applications and Reviews"},{"issue":"4","key":"90_CR120","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1145\/1165387.275628","volume":"18","author":"T. G. Zimmerman","year":"1986","unstructured":"T. G. Zimmerman, J. Lanier, C. Blanchard, S. Bryson, and Y. Harvill, \u201cA hand gesture interface device,\u201d SIGCHI Bulletin, vol. 18, no. 4, pp. 189\u2013192, 1986.","journal-title":"SIGCHI Bulletin"},{"key":"90_CR121","unstructured":"M. C. Zimmerman, \u201cOptical flex sensor,\u201d US Patent 4542291, Sept. 17, 1985."},{"issue":"4","key":"90_CR122","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1682\/JRRD.1990.10.0411","volume":"27","author":"S. Wise","year":"1990","unstructured":"S. Wise and G. William, \u201cEvaluation of a fiber optic glove for semi-automated goniometric measurements,\u201d Journal of Rehabilitation Research and Development, vol. 27, no. 4, pp. 411\u2013424, 1990.","journal-title":"Journal of Rehabilitation Research and Development"},{"key":"90_CR123","first-page":"437","volume":"1","author":"H. Grant","year":"1998","unstructured":"H. Grant and L. Chuen-Ki, \u201cSimulation modeling with artificial reality technology (SMART): an integration of virtual reality and simulation modeling,\u201d in Simulation Conference Proceedings, Washington, D.C., Dec. 13\u201316, vol. 1, pp. 437\u2013441, 1998.","journal-title":"Simulation Conference Proceedings, Washington, D.C., Dec. 13\u201316"},{"issue":"2","key":"90_CR124","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1109\/TITB.2009.2038995","volume":"14","author":"M. Huber","year":"2010","unstructured":"M. Huber, B. Rabin, C. Docan, G. C. Burdea, M. AbdelBaky, and M. R. Golomb, \u201cFeasibility of modified remotely monitored in-home gaming technology for improving hand function in adolescents with cerebral palsy,\u201d IEEE Transactions on Information Technology in Biomedicine, vol. 14, no. 2, pp. 526\u2013534, 2010.","journal-title":"IEEE Transactions on Information Technology in Biomedicine"},{"issue":"1","key":"90_CR125","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.apmr.2009.08.153","volume":"91","author":"M. R. Golomb","year":"2010","unstructured":"M. R. Golomb, B. C. McDonald, S. J. Warden, J. Yonkman, A. J. Saykin, B. Shirley, et al., \u201cIn-home virtual reality videogame telerehabilitation in adolescents with hemiplegic cerebral palsy,\u201d Archives of Physical Medicine and Rehabilitation, vol. 91, no. 1, pp. 1\u20138, 2010.","journal-title":"Archives of Physical Medicine and Rehabilitation"},{"key":"90_CR126","unstructured":"5DT. (2011, 1 May). Price list. Available: http:\/\/www.5dt.com\/pricelist.html ."},{"key":"90_CR127","unstructured":"OFSETH. (2006, 15 Nov.). Optical fiber sensors embedded into technical textile for healthcare. Available: www.ofseth.org\/ ."},{"key":"90_CR128","first-page":"3950","volume":"2007","author":"J. Jonckheere De","year":"2007","unstructured":"J. De Jonckheere, M. Jeanne, A. Grillet, S. Weber, P. Chaud, R. Logier, et al., \u201cOFSETH: optical fiber embedded into technical textile for healthcare, an efficient way to monitor patient under magnetic resonance imaging,\u201d in Conference Proceedings \u2014 IEEE Engineering in Medicine and Biology Society, Lyon, Aug. 22\u201326, vol. 2007, pp. 3950\u20133953, 2007.","journal-title":"Conference Proceedings \u2014 IEEE Engineering in Medicine and Biology Society, Lyon, Aug. 22\u201326"},{"issue":"7","key":"90_CR129","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1109\/JSEN.2008.926518","volume":"8","author":"A. Grillet","year":"2008","unstructured":"A. Grillet, D. Kinet, J. Witt, M. Schukar, K. Krebber, F. Pirotte, et al., \u201cOptical fiber sensors embedded into medical textiles for healthcare monitoring,\u201d IEEE Sensors Journal, vol. 8, no. 7, pp. 1215\u20131222, 2008.","journal-title":"IEEE Sensors Journal"},{"key":"90_CR130","first-page":"5266","volume":"2008","author":"J. Jonckheere De","year":"2008","unstructured":"J. De Jonckheere, F. Narbonneau, D. Kinet, J. Zinke, B. Paquet, A. Depre, et al., \u201cOptical fiber sensors embedded into technical textile for a continuous monitoring of patients under Magnetic Resonance Imaging,\u201d in Conference Proceedings \u2014 IEEE Engineering in Medicine and Biology Society, vol. 2008, pp. 5266\u20135269, 2008.","journal-title":"Conference Proceedings \u2014 IEEE Engineering in Medicine and Biology Society"},{"key":"90_CR131","unstructured":"J. De Jonckheere, F. Narbonneau, D. Kinet, J. Witt, K. Krebber, B. Paquet, et al., \u201cOFSETH: smart medical textile for continuous monitoring of respiratory motions under magnetic resonance imaging,\u201d in Conference Proceedings \u2014 IEEE Engineering in Medicine and Biology Society, Minneapolis, Sept. 3\u20136, pp. 1473\u20131476, 2009."},{"key":"90_CR132","unstructured":"J. De Jonckheere, M. Jeanne, F. Narbonneau, J. Witt, B. Paquet, D. Kinet, et al., \u201cOFSETH: a breathing motions monitoring system for patients under MRI,\u201d in Conference Proceedings \u2014 IEEE Engineering in Medicine and Biology Society, Buenos Aires, Aug. 31\u2013Sept. 4, pp. 1016\u20131019, 2010."},{"key":"90_CR133","unstructured":"J. De Jonckheere, F. Narbonneau, D. Kinet, J. Zinke, B. Paquet, A. Depre, et al., \u201cOptical fiber sensors embedded into technical textile for a continuous monitoring of patients under magnetic resonance imaging,\u201d in Engineering in Medicine and Biology Society, 2008. EMBS 2008. 30th Annual International Conference of the IEEE, Vancouver, Aug. 20\u201325, pp. 5266\u20135269, 2008."},{"issue":"2","key":"90_CR134","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1109\/TBME.2007.912627","volume":"55","author":"W. C. Wang","year":"2008","unstructured":"W. C. Wang, W. R. Ledoux, C. Y. Huang, C. S. Huang, G. K. Klute, and P. G.. Reinhall, \u201cDevelopment of a microfabricated optical bend loss sensor for distributive pressure measurement,\u201d IEEE Transactions on Biomedical Engineering, vol. 55, no. 2, pp. 614\u2013625, 2008.","journal-title":"IEEE Transactions on Biomedical Engineering"},{"issue":"3","key":"90_CR135","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1682\/JRRD.2004.07.0076","volume":"42","author":"W. C. Wang","year":"2005","unstructured":"W. C. Wang, W. R. Ledoux, B. J. Sangeorzan, P. G.. Reinhall, \u201cA shear and plantar pressure sensor based on fiber-optic bend loss,\u201d Journal of Rehabilitation Research and Development, vol. 42, no. 3, pp. 315\u201325, 2005.","journal-title":"Journal of Rehabilitation Research and Development"},{"issue":"9","key":"90_CR136","doi-asserted-by":"crossref","first-page":"1893","DOI":"10.1364\/AO.45.001893","volume":"45","author":"W. C. Wang","year":"2006","unstructured":"W. C. Wang, C. T. Ho, Y. R. Lian, and W. C. Chuang, \u201cTransducing mechanical force by use of a diffraction grating sensor,\u201d Applied Optics, vol. 45, no. 9, pp. 1893\u20131897, 2006.","journal-title":"Applied Optics"},{"key":"90_CR137","doi-asserted-by":"crossref","unstructured":"W. C. Wang, C. Y. Huang, T. K. Chiang, and P. G. Reinhall, \u201cOptical and mechanical characterization of microfabricated optical bend loss sensor for distributive pressure measurement,\u201d in Health Monitoring Structural and Biological Systems 2007, San Diego, California, USA, Mar. 19\u201322, pp. 65321K\u201310, 2007.","DOI":"10.1117\/12.715925"},{"key":"90_CR138","doi-asserted-by":"crossref","first-page":"79840Z-1","DOI":"10.1117\/12.898467","volume":"7984","author":"W. Soetanto","year":"2011","unstructured":"W. Soetanto, N. T. Nguyen, and W. C. Wang, \u201cFiber optic plantar pressure\/shear sensor,\u201d in Proc. SPIE, vol. 7984, pp. 79840Z-1\u201379840Z-7, 2011.","journal-title":"Proc. SPIE"}],"container-title":["Photonic Sensors"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s13320-012-0090-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s13320-012-0090-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s13320-012-0090-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s13320-012-0090-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T21:01:59Z","timestamp":1768510919000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s13320-012-0090-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,10,13]]},"references-count":138,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2012,12]]}},"alternative-id":["90"],"URL":"https:\/\/doi.org\/10.1007\/s13320-012-0090-3","relation":{},"ISSN":["1674-9251","2190-7439"],"issn-type":[{"value":"1674-9251","type":"print"},{"value":"2190-7439","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,10,13]]}}}