{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T00:53:00Z","timestamp":1791247980132,"version":"4.1.0"},"reference-count":24,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[1986,4,1]],"date-time":"1986-04-01T00:00:00Z","timestamp":512697600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[1986,4,1]],"date-time":"1986-04-01T00:00:00Z","timestamp":512697600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["amjmed.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The American Journal of Medicine"],"published-print":{"date-parts":[[1986,4]]},"DOI":"10.1016\/0002-9343(86)90809-0","type":"journal-article","created":{"date-parts":[[2004,6,2]],"date-time":"2004-06-02T16:57:06Z","timestamp":1086195426000},"page":"567-573","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":51,"title":["Potential in-hospital modes of transmission of legionella pneumophila. Demonstration experiments for dissemination by showers, humidifiers, and rinsing of ventilation bag apparatus"],"prefix":"10.1016","volume":"80","author":[{"given":"Andrew H.","family":"Woo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor L.","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Angella","family":"Goetz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/0002-9343(86)90809-0_BIB1","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/0002-9343(82)90727-6","article-title":"Legionnaires' disease: new clinical perspective from a prospective pneumonia study","volume":"73","author":"Yu","year":"1982","journal-title":"Am J Med"},{"key":"10.1016\/0002-9343(86)90809-0_BIB2","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1016\/0002-9343(81)90601-X","article-title":"Sporadic and epidemic nosocomial legionellosis in the United States","volume":"70","author":"England","year":"1980","journal-title":"Am J Med"},{"key":"10.1016\/0002-9343(86)90809-0_BIB3","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(83)90290-8","article-title":"Legionellaceae in the hospital water supply-epidemiologic link with disease and evaluation of a method for control of nosocomial Legionnaires' disease and Pittsburgh pneumonia","volume":"II","author":"Best","year":"1983","journal-title":"Lancet"},{"key":"10.1016\/0002-9343(86)90809-0_BIB4","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1128\/aem.46.3.769-770.1983","article-title":"Relationship between colonization of hospital buildings with Legionella pneumophila and hot water temperatures","volume":"46","author":"Plouffe","year":"1982","journal-title":"Appl Environ Microbiol"},{"key":"10.1016\/0002-9343(86)90809-0_BIB5","doi-asserted-by":"crossref","first-page":"172","DOI":"10.7326\/0003-4819-99-2-172","article-title":"Legionnaires' disease associated with a hospital water system","volume":"99","author":"Helms","year":"1982","journal-title":"Ann Intern Med"},{"key":"10.1016\/0002-9343(86)90809-0_BIB6","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/S0140-6736(82)91449-0","article-title":"Potable water supply as the hospital reservoir for Pittsburgh pneumonia agent","volume":"I","author":"Stout","year":"1982","journal-title":"Lancet"},{"key":"10.1016\/0002-9343(86)90809-0_BIB7","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1056\/NEJM198202253060807","article-title":"Ubiquitousness of Legionella pneumophila in the water supply of a hospital with endemic Legionnaires' disease","volume":"306","author":"Stout","year":"1982","journal-title":"N Engl J Med"},{"key":"10.1016\/0002-9343(86)90809-0_BIB8","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1128\/aem.48.5.984-987.1984","article-title":"Role of stagnation and obstruction of water flow in isolation of Legionella pneumophila from hospital plumbing","volume":"48","author":"Ciesielski","year":"1984","journal-title":"Appl Environ Microbiol"},{"key":"10.1016\/0002-9343(86)90809-0_BIB9","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1128\/aem.49.1.221-228.1985","article-title":"The ecology of Legionella pneumophila within water distribution systems","volume":"49","author":"Stout","year":"1985","journal-title":"Appl Environ Microbiol"},{"key":"10.1016\/0002-9343(86)90809-0_BIB10","first-page":"112","article-title":"Legionnaires' disease in a transplant unit: isolation of the causative agent from shower baths","volume":"II","author":"Tobin","year":"1980","journal-title":"Lancet"},{"key":"10.1016\/0002-9343(86)90809-0_BIB11","doi-asserted-by":"crossref","first-page":"195","DOI":"10.7326\/0003-4819-94-2-195","article-title":"Isolation of Legionella pneumophila from hospital showerheads","volume":"94","author":"Cordes","year":"1981","journal-title":"Ann Intern Med"},{"key":"10.1016\/0002-9343(86)90809-0_BIB12","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1017\/S0022172400064901","article-title":"Legionella pneumophila in aerosols from shower baths","volume":"93","author":"Dennis","year":"1984","journal-title":"J Hyg (Camb)"},{"key":"10.1016\/0002-9343(86)90809-0_BIB13","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.1128\/aem.50.5.1128-1131.1985","article-title":"Aerosols containing Legionella pneumophila generated by shower heads and hot water faucets","volume":"50","author":"Bollin","year":"1985","journal-title":"Appl Environ Microbiol"},{"key":"10.1016\/0002-9343(86)90809-0_BIB14","first-page":"657","article-title":"Legionella pneumophila contamination of a hospital humidifier: demonstration of aerosol transmission and subsequent subclinical infection in exposed guinea pigs","volume":"128","author":"Zuravleff","year":"1983","journal-title":"Am Rev Respir Dis"},{"key":"10.1016\/0002-9343(86)90809-0_BIB15","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1093\/infdis\/146.4.460","article-title":"Nosocomial Legionnaires' disease caused by aerosolized tap water from respiratory devices","volume":"146","author":"Arnow","year":"1982","journal-title":"J Infect Dis"},{"key":"10.1016\/0002-9343(86)90809-0_BIB16","doi-asserted-by":"crossref","first-page":"572","DOI":"10.7326\/0003-4819-93-4-572","article-title":"Isolation of Pittsburgh pneumonia agent from nebulizers used in respiratory therapy","volume":"93","author":"Gorman","year":"1980","journal-title":"Ann Intern Med"},{"key":"10.1016\/0002-9343(86)90809-0_BIB17","doi-asserted-by":"crossref","first-page":"525","DOI":"10.7326\/0003-4819-100-4-525","article-title":"Prosthetic valve endocarditis caused by Legionella pneumophila","volume":"100","author":"McCabe","year":"1984","journal-title":"Ann Intern Med"},{"key":"10.1016\/0002-9343(86)90809-0_BIB18","doi-asserted-by":"crossref","first-page":"297","DOI":"10.7326\/0003-4819-89-3-297","article-title":"Legionnaires disease: clinical features of 24 cases","volume":"89","author":"Kirby","year":"1978","journal-title":"Ann Intern Med"},{"key":"10.1016\/0002-9343(86)90809-0_BIB19","doi-asserted-by":"crossref","first-page":"953","DOI":"10.1056\/NEJM197911013011801","article-title":"Opportunistic lung infection due to Pittsburgh pneumonia agent","volume":"301","author":"Meyerowitz","year":"1979","journal-title":"N Engl J Med"},{"key":"10.1016\/0002-9343(86)90809-0_BIB20","series-title":"Intersci Conf Antimicrob Agents Chemother","article-title":"Aspiration of contaminated water may be a mode of transmission for Legionella pneumophila (abstr 297)","author":"Yu","year":"1981"},{"key":"10.1016\/0002-9343(86)90809-0_BIB21","doi-asserted-by":"crossref","first-page":"3184","DOI":"10.1001\/jama.1983.03330470024025","article-title":"Nosocomial Legionnaires' disease uncovered in a prospective pneumonia study: implications for underdiagnosis","volume":"249","author":"Muder","year":"1982","journal-title":"JAMA"},{"issue":"suppl 5A","key":"10.1016\/0002-9343(86)90809-0_BIB22","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/0002-9343(84)90243-2","article-title":"Extrinsic risk factors for pneumonia in the patient at high risk of infection","volume":"76","author":"Rhame","year":"1984","journal-title":"Am J Med"},{"key":"10.1016\/0002-9343(86)90809-0_BIB23","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/0196-6553(84)90069-5","article-title":"Heat eradication measures for control of Legionnaires' disease: implementation, education, and cost analysis","volume":"12","author":"Best","year":"1982","journal-title":"Am J Infect Control"},{"key":"10.1016\/0002-9343(86)90809-0_BIB24","series-title":"Guidelines for prevention and control of nosocomial infection","first-page":"7","article-title":"Guidelines for prevention of nosocomial pneumonia","author":"Simmons","year":"1981"}],"container-title":["The American Journal of Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:0002934386908090?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:0002934386908090?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,3]],"date-time":"2025-09-03T07:15:11Z","timestamp":1756883711000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/0002934386908090"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1986,4]]},"references-count":24,"journal-issue":{"issue":"4","published-print":{"date-parts":[[1986,4]]}},"alternative-id":["0002934386908090"],"URL":"https:\/\/doi.org\/10.1016\/0002-9343(86)90809-0","relation":{},"ISSN":["0002-9343"],"issn-type":[{"value":"0002-9343","type":"print"}],"subject":[],"published":{"date-parts":[[1986,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Potential in-hospital modes of transmission of legionella pneumophila. Demonstration experiments for dissemination by showers, humidifiers, and rinsing of ventilation bag apparatus","name":"articletitle","label":"Article Title"},{"value":"The American Journal of Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/0002-9343(86)90809-0","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"converted-article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 1986 Published by Excerpta Medica Inc.","name":"copyright","label":"Copyright"}]}}