{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T12:09:54Z","timestamp":1789560594069,"version":"build-2803163510"},"reference-count":23,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[1992,6,1]],"date-time":"1992-06-01T00:00:00Z","timestamp":707356800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Hand Surgery"],"published-print":{"date-parts":[[1992,6]]},"abstract":"<jats:p>The literature indicates that tourniquet-induced neurological injuries are relatively common and frequently occur at a subclinical level. In order to evaluate the pressure transmitted to the major peripheral nerves of the arm by an externally applied pneumatic tourniquet, a fully implantable biomedical pressure transducer was placed adjacent the radial, median and ulnar nerves in six cadaver upper extremities of average dimensions. This sensor allowed accurate, reproducible measurements of perineural pressures without requiring significant disruption of the normal anatomical structures of the test limb for its installation. At levels of tourniquet cuff inflation which are commonly used in clinical practice, there was little or no decrease in the pressure detected in the perineural regions over that applied to the surface of the limb. In addition, there was a steep gradient of perineural pressure between locations beneath the edge of the cuff and those under its midpoint. This was most marked at the highest levels of tourniquet inflation. At presently accepted levels of inflation, pneumatic tourniquet cuffs transmit high pressures to the peripheral nerves without any significant attenuation by the intervening soft tissues. The distribution of these forces is one which may subject the underlying nerves to deleterious shear forces, especially at higher levels of inflation.<\/jats:p>","DOI":"10.1016\/0266-7681(92)90111-e","type":"journal-article","created":{"date-parts":[[2005,6,17]],"date-time":"2005-06-17T13:57:36Z","timestamp":1119016656000},"page":"262-266","source":"Crossref","is-referenced-by-count":36,"title":["Perineural Pressures under the Pneumatic Tourniquet in the Upper Extremity"],"prefix":"10.1177","volume":"17","author":[{"given":"B.","family":"GRAHAM","sequence":"first","affiliation":[{"name":"From the Departments of Orthopaedic Surgery and Biomedical Engineering, University of British Columbia, Vancouver, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. J.","family":"BREAULT","sequence":"additional","affiliation":[{"name":"From the Departments of Orthopaedic Surgery and Biomedical Engineering, University of British Columbia, Vancouver, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. A.","family":"McEWEN","sequence":"additional","affiliation":[{"name":"From the Departments of Orthopaedic Surgery and Biomedical Engineering, University of British Columbia, Vancouver, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. W.","family":"McGRAW","sequence":"additional","affiliation":[{"name":"From the Departments of Orthopaedic Surgery and Biomedical Engineering, University of British Columbia, Vancouver, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[1992,6,1]]},"reference":[{"key":"b1-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1113\/jphysiol.1943.sp004016"},{"key":"b2-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.28.8.787"},{"key":"b3-10.1016_0266-7681_92_90111-e","unstructured":"BREAULT, MJ. Biomechanical investigations of blood flow occlusion achieved with the use of surgical pneumatic tourniquets. University of British Colombia, Department of Mechanical Engineering. M.A.Sc. thesis: October 1988"},{"key":"b4-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp.35.5.638"},{"key":"b5-10.1016_0266-7681_92_90111-e","author":"GRAHAM B","journal-title":"Clinical Orthopaedics and Related Research"},{"key":"b6-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1016\/0072-968X(73)90050-8"},{"key":"b7-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100050211"},{"key":"b8-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1097\/00006534-198105000-00014"},{"key":"b9-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1016\/S0072-968X(80)80044-1"},{"key":"b10-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1016\/0363-5023(88)90266-3"},{"key":"b11-10.1016_0266-7681_92_90111-e","unstructured":"McEWEN, JA. Biomedical pressure transducer. United States Patent Number 4,869,265; September 26th, 1989"},{"key":"b12-10.1016_0266-7681_92_90111-e","first-page":"5","volume-title":"Unsatisfactory Results in Hand Surgery","author":"McGRAW RW","year":"1987"},{"key":"b13-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198567030-00014"},{"key":"b14-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1111\/j.1445-2197.1974.tb06402.x"},{"key":"b15-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(87)80098-9"},{"key":"b16-10.1016_0266-7681_92_90111-e","first-page":"821","volume":"146","author":"MULLICK S","year":"1978","journal-title":"Surgery, Gynecology and Obstetrics"},{"key":"b17-10.1016_0266-7681_92_90111-e","first-page":"433","volume":"113","author":"OCHOA J","year":"1972","journal-title":"Journal of Anatomy"},{"key":"b18-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1016\/0072-968X(73)90049-1"},{"key":"b19-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-198004000-00002"},{"key":"b20-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.56B4.716"},{"key":"b21-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198264080-00004"},{"key":"b22-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(85)90002-6"},{"key":"b23-10.1016_0266-7681_92_90111-e","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp.44.9.759"}],"container-title":["Journal of Hand Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1016\/0266-7681%2892%2990111-E","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1016\/0266-7681%2892%2990111-E","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T22:42:45Z","timestamp":1777502565000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1016\/0266-7681%2892%2990111-E"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1992,6]]},"references-count":23,"journal-issue":{"issue":"3","published-print":{"date-parts":[[1992,6]]}},"alternative-id":["10.1016\/0266-7681(92)90111-E"],"URL":"https:\/\/doi.org\/10.1016\/0266-7681(92)90111-e","relation":{},"ISSN":["0266-7681"],"issn-type":[{"value":"0266-7681","type":"print"}],"subject":[],"published":{"date-parts":[[1992,6]]}}}