{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T19:05:19Z","timestamp":1775502319542,"version":"3.50.1"},"reference-count":37,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T00:00:00Z","timestamp":1773792000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Advanced Engineering Informatics"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1016\/j.aei.2026.104595","type":"journal-article","created":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T12:47:18Z","timestamp":1774270038000},"page":"104595","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"PA","title":["Hybrid method combining sensitivity-based algorithm and Transformer\u2013UNet model for 3D electromagnetic tomography: Conductivity-based shape reconstruction and defect detection"],"prefix":"10.1016","volume":"74","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5049-1958","authenticated-orcid":false,"given":"Saibo","family":"She","sequence":"first","affiliation":[]},{"given":"Xinnan","family":"Zheng","sequence":"additional","affiliation":[]},{"given":"Xun","family":"Zou","sequence":"additional","affiliation":[]},{"given":"Kuohai","family":"Yu","sequence":"additional","affiliation":[]},{"given":"Yunze","family":"He","sequence":"additional","affiliation":[]},{"given":"Wuliang","family":"Yin","sequence":"additional","affiliation":[]},{"given":"Anthony J.","family":"Peyton","sequence":"additional","affiliation":[]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.aei.2026.104595_b1","doi-asserted-by":"crossref","first-page":"2228","DOI":"10.1109\/TII.2022.3205372","article-title":"Federated-Learning-Based synchrotron X-Ray microdiffraction image screening for industry materials","volume":"19","author":"Chen","year":"2022","journal-title":"IEEE Trans. Ind. Inform."},{"issue":"4","key":"10.1016\/j.aei.2026.104595_b2","doi-asserted-by":"crossref","first-page":"6099","DOI":"10.1109\/TII.2023.3342442","article-title":"BDAL: Balanced distribution active learning for MRI cardiac multistructures segmentation","volume":"20","author":"Shu","year":"2023","journal-title":"IEEE Trans. Ind. Inform."},{"issue":"2","key":"10.1016\/j.aei.2026.104595_b3","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1109\/TII.2018.2871864","article-title":"Robotic arm based automatic ultrasound scanning for Three-Dimensional imaging","volume":"15","author":"Huang","year":"2019","journal-title":"IEEE Trans. Ind. Inform."},{"issue":"9","key":"10.1016\/j.aei.2026.104595_b4","doi-asserted-by":"crossref","first-page":"5033","DOI":"10.1109\/TII.2019.2895469","article-title":"Accelerated Structure-Aware sparse Bayesian learning for Three-Dimensional electrical impedance tomography","volume":"15","author":"Liu","year":"2019","journal-title":"IEEE Trans. Ind. Inform."},{"issue":"3","key":"10.1016\/j.aei.2026.104595_b5","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1109\/JPROC.2012.2237072","article-title":"Electromagnetic tomography for medical and industrial applications: Challenges and opportunities [point of view]","volume":"101","author":"Wei","year":"2013","journal-title":"Proc. IEEE"},{"key":"10.1016\/j.aei.2026.104595_b6","doi-asserted-by":"crossref","DOI":"10.1016\/j.cherd.2024.06.018","article-title":"Developments and applications of electromagnetic tomography in process engineering","author":"Sharifi","year":"2024","journal-title":"Chem. Eng. Res. Des."},{"issue":"9","key":"10.1016\/j.aei.2026.104595_b7","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6501\/ab1ef7","article-title":"Multimodal imaging of multiphase flows with electromagnetic flow tomography and electrical tomography","volume":"30","author":"Vauhkonen","year":"2019","journal-title":"Meas. Sci. Technol."},{"issue":"1","key":"10.1016\/j.aei.2026.104595_b8","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/0167-8760(84)90014-X","article-title":"Low resolution electromagnetic tomography: a new method for localizing electrical activity in the brain","volume":"18","author":"Pascual-Marqui","year":"1994","journal-title":"Int. J. Psychophysiol."},{"issue":"Suppl D","key":"10.1016\/j.aei.2026.104595_b9","first-page":"5","article-title":"Standardized low-resolution brain electromagnetic tomography (sLORETA): technical details","volume":"24","author":"Pascual-Marqui","year":"2002","journal-title":"Methods Find. Exp. Clin. Pharmacol."},{"issue":"24","key":"10.1016\/j.aei.2026.104595_b10","doi-asserted-by":"crossref","first-page":"8196","DOI":"10.1109\/JSEN.2017.2682929","article-title":"Application of process tomography to multiphase flow measurement in industrial and biomedical fields: A review","volume":"17","author":"Yao","year":"2017","journal-title":"IEEE Sens. J."},{"issue":"10","key":"10.1016\/j.aei.2026.104595_b11","first-page":"1","article-title":"Electromagnetic tomography rail defect inspection","volume":"51","author":"Liu","year":"2015","journal-title":"IEEE Trans. Magn."},{"key":"10.1016\/j.aei.2026.104595_b12","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.ndteint.2017.07.018","article-title":"Experimental and simulation methods to study the Magnetic Tomography Method (MTM) for pipe defect detection","volume":"92","author":"Li","year":"2017","journal-title":"NDT E Int."},{"issue":"8","key":"10.1016\/j.aei.2026.104595_b13","doi-asserted-by":"crossref","first-page":"2130","DOI":"10.1088\/0957-0233\/17\/8\/011","article-title":"A planar EMT system for the detection of faults on thin metallic plates","volume":"17","author":"Yin","year":"2006","journal-title":"Meas. Sci. Technol."},{"issue":"3","key":"10.1016\/j.aei.2026.104595_b14","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1088\/0957-0233\/7\/3\/006","article-title":"An overview of electromagnetic inductance tomography: description of three different systems","volume":"7","author":"Peyton","year":"1996","journal-title":"Meas. Sci. Technol."},{"issue":"5","key":"10.1016\/j.aei.2026.104595_b15","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1049\/iet-ipr.2009.0169","article-title":"Improvement of signal-to-noise ratio and image stability in magnetic inductance tomography by exploiting transient response analysis","volume":"5","author":"Yin","year":"2011","journal-title":"IET Image Process."},{"key":"10.1016\/j.aei.2026.104595_b16","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s11220-019-0250-2","article-title":"Simulation research of impact of number of coils in EMT sensors on reconstructed images quality","volume":"20","author":"Liu","year":"2019","journal-title":"Sens. Imaging"},{"key":"10.1016\/j.aei.2026.104595_b17","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.flowmeasinst.2012.04.011","article-title":"Landweber iterative algorithm based on regularization in electromagnetic tomography for multiphase flow measurement","volume":"27","author":"Liu","year":"2012","journal-title":"Flow Meas. Instrum."},{"key":"10.1016\/j.aei.2026.104595_b18","series-title":"2018 13th World Congress on Intelligent Control and Automation","first-page":"484","article-title":"An iterative linear back-projection algorithm for electrical impedance tomography","author":"Wang","year":"2018"},{"issue":"5","key":"10.1016\/j.aei.2026.104595_b19","doi-asserted-by":"crossref","first-page":"1999","DOI":"10.1109\/TNS.1977.4329148","article-title":"Back projection speed improvement for 3-D reconstruction","volume":"24","author":"Kwoh","year":"1977","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"10.1016\/j.aei.2026.104595_b20","doi-asserted-by":"crossref","DOI":"10.1016\/j.flowmeasinst.2020.101850","article-title":"3D electromagnetic tomography using a single layer sensor array","volume":"77","author":"Yue","year":"2021","journal-title":"Flow Meas. Instrum."},{"issue":"9","key":"10.1016\/j.aei.2026.104595_b21","doi-asserted-by":"crossref","first-page":"4758","DOI":"10.1109\/JSEN.2020.2966274","article-title":"Research on direct 3D electromagnetic tomography technique","volume":"20","author":"Liu","year":"2020","journal-title":"IEEE Sens. J."},{"issue":"9","key":"10.1016\/j.aei.2026.104595_b22","doi-asserted-by":"crossref","first-page":"15477","DOI":"10.1109\/JSEN.2025.3547254","article-title":"Detection of magnetic samples by electromagnetic tomography with PID-Controlled iterative L1 regularization method","volume":"25","author":"Huang","year":"2025","journal-title":"IEEE Sens. J."},{"issue":"12","key":"10.1016\/j.aei.2026.104595_b23","doi-asserted-by":"crossref","DOI":"10.1063\/1.5120118","article-title":"Sparse defects detection and 3D imaging base on electromagnetic tomography and total variation algorithm","volume":"90","author":"Wang","year":"2019","journal-title":"Rev. Sci. Instrum."},{"key":"10.1016\/j.aei.2026.104595_b24","doi-asserted-by":"crossref","DOI":"10.1016\/j.aei.2025.103284","article-title":"3D-MMFN: Multi-level multimodal fusion network for 3D industrial image anomaly detection","volume":"65","author":"Asad","year":"2025","journal-title":"Adv. Eng. Inform."},{"key":"10.1016\/j.aei.2026.104595_b25","doi-asserted-by":"crossref","DOI":"10.1016\/j.aei.2025.103373","article-title":"An efficient 2D-3D fusion method for bridge damage detection under complex backgrounds with imbalanced training data","volume":"65","author":"Zhang","year":"2025","journal-title":"Adv. Eng. Inform."},{"key":"10.1016\/j.aei.2026.104595_b26","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/TIM.2025.3580877","article-title":"Fast Real-Time electromagnetic tomography system for size prediction and material and position classification","volume":"74","author":"She","year":"2025","journal-title":"IEEE Trans. Instrum. Meas."},{"issue":"8","key":"10.1016\/j.aei.2026.104595_b27","doi-asserted-by":"crossref","first-page":"3290","DOI":"10.1109\/JSEN.2018.2809485","article-title":"Deep learning image reconstruction simulation for electromagnetic tomography","volume":"18","author":"Xiao","year":"2018","journal-title":"IEEE Sens. J."},{"issue":"21","key":"10.1016\/j.aei.2026.104595_b28","doi-asserted-by":"crossref","first-page":"34907","DOI":"10.1109\/JSEN.2024.3446798","article-title":"TV-Net for 3-D electromagnetic tomography image reconstruction","volume":"24","author":"Fu","year":"2024","journal-title":"IEEE Sens. J."},{"key":"10.1016\/j.aei.2026.104595_b29","first-page":"1","article-title":"Simultaneous conductivity and permeability reconstructions for electromagnetic tomography using deep learning","volume":"72","author":"Zhang","year":"2023","journal-title":"IEEE Trans. Instrum. Meas."},{"issue":"20","key":"10.1016\/j.aei.2026.104595_b30","doi-asserted-by":"crossref","first-page":"33573","DOI":"10.1109\/JSEN.2024.3350742","article-title":"MITNet: GAN enhanced magnetic induction tomography based on complex CNN","volume":"24","author":"Chen","year":"2024","journal-title":"IEEE Sens. J."},{"key":"10.1016\/j.aei.2026.104595_b31","article-title":"Deep learning for image reconstruction in electrical tomography: A review","author":"Li","year":"2025","journal-title":"IEEE Sens. J."},{"issue":"1","key":"10.1016\/j.aei.2026.104595_b32","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1109\/TII.2024.3456443","article-title":"PDCISTA-Net: Model-Driven deep learning reconstruction network for electrical impedance Tomography-Based tactile sensing","volume":"21","author":"Ma","year":"2025","journal-title":"IEEE Trans. Ind. Inform."},{"issue":"7","key":"10.1016\/j.aei.2026.104595_b33","doi-asserted-by":"crossref","first-page":"4887","DOI":"10.1109\/TIM.2019.2954722","article-title":"A Two-Stage deep learning method for robust shape reconstruction with electrical impedance tomography","volume":"69","author":"Ren","year":"2020","journal-title":"IEEE Trans. Instrum. Meas."},{"issue":"11","key":"10.1016\/j.aei.2026.104595_b34","doi-asserted-by":"crossref","first-page":"2533","DOI":"10.1109\/TMI.2019.2905245","article-title":"B-spline-based sharp feature preserving shape reconstruction approach for electrical impedance tomography","volume":"38","author":"Liu","year":"2019","journal-title":"IEEE Trans. Med. Imaging"},{"issue":"6","key":"10.1016\/j.aei.2026.104595_b35","doi-asserted-by":"crossref","first-page":"1809","DOI":"10.1088\/0266-5611\/18\/6\/323","article-title":"A new non-iterative inversion method for electrical resistance tomography","volume":"18","author":"Tamburrino","year":"2002","journal-title":"Inverse Problems"},{"issue":"4","key":"10.1016\/j.aei.2026.104595_b36","doi-asserted-by":"crossref","first-page":"1505","DOI":"10.1137\/090773970","article-title":"Exact Shape-Reconstruction by One-Step linearization in electrical impedance tomography","volume":"42","author":"Harrach","year":"2010","journal-title":"SIAM J. Math. Anal."},{"issue":"12","key":"10.1016\/j.aei.2026.104595_b37","doi-asserted-by":"crossref","first-page":"2185","DOI":"10.1109\/TMI.2012.2204438","article-title":"Shape deformation in Two-Dimensional electrical impedance tomography","volume":"31","author":"Boyle","year":"2012","journal-title":"IEEE Trans. Med. Imaging"}],"container-title":["Advanced Engineering Informatics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1474034626002879?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1474034626002879?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T18:04:17Z","timestamp":1775498657000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1474034626002879"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9]]},"references-count":37,"alternative-id":["S1474034626002879"],"URL":"https:\/\/doi.org\/10.1016\/j.aei.2026.104595","relation":{},"ISSN":["1474-0346"],"issn-type":[{"value":"1474-0346","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Hybrid method combining sensitivity-based algorithm and Transformer\u2013UNet model for 3D electromagnetic tomography: Conductivity-based shape reconstruction and defect detection","name":"articletitle","label":"Article Title"},{"value":"Advanced Engineering Informatics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.aei.2026.104595","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"104595"}}