{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T12:17:10Z","timestamp":1777378630363,"version":"3.51.4"},"reference-count":35,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T00:00:00Z","timestamp":1774224000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Array"],"published-print":{"date-parts":[[2026,7]]},"DOI":"10.1016\/j.array.2026.100778","type":"journal-article","created":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T08:02:17Z","timestamp":1774425737000},"page":"100778","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Task-specific sensor discovery through attention-based deep learning: Enabling automated dataset auditing for clinical gait analysis"],"prefix":"10.1016","volume":"30","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9783-7795","authenticated-orcid":false,"given":"Hamidreza","family":"Sadeghsalehi","sequence":"first","affiliation":[]}],"member":"78","reference":[{"issue":"7","key":"10.1016\/j.array.2026.100778_bib1","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1016\/S1474-4422(19)30044-4","article-title":"Gait impairments in parkinson's disease","volume":"18","author":"Mirelman","year":"2019","journal-title":"Lancet Neurol"},{"issue":"2","key":"10.1016\/j.array.2026.100778_bib2","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1016\/j.gaitpost.2009.10.014","article-title":"Evaluation of gait symmetry after stroke: a comparison of current methods and recommendations for standardization","volume":"31","author":"Patterson","year":"2010","journal-title":"Gait Posture"},{"issue":"10","key":"10.1016\/j.array.2026.100778_bib3","doi-asserted-by":"crossref","first-page":"1643","DOI":"10.1002\/acr.22015","article-title":"Biomechanical deviations during level walking associated with knee osteoarthritis: a systematic review and meta-analysis","volume":"65","author":"Mills","year":"2013","journal-title":"Arthritis Care Res"},{"issue":"1","key":"10.1016\/j.array.2026.100778_bib4","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1186\/s12984-016-0154-5","article-title":"Free-living gait characteristics in ageing and parkinson's disease: impact of environment and ambulatory bout length","volume":"13","author":"Del Din","year":"2016","journal-title":"J NeuroEng Rehabil"},{"issue":"3","key":"10.1016\/j.array.2026.100778_bib5","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.gaitpost.2006.10.014","article-title":"The history of gait analysis before the advent of modern computers","volume":"26","author":"Baker","year":"2007","journal-title":"Gait Posture"},{"issue":"2","key":"10.1016\/j.array.2026.100778_bib6","first-page":"239","article-title":"The relevance of clinical balance assessment tools to differentiate balance deficits","volume":"46","author":"Mancini","year":"2010","journal-title":"Eur J Phys Rehabil Med"},{"issue":"2","key":"10.1016\/j.array.2026.100778_bib7","doi-asserted-by":"crossref","first-page":"2255","DOI":"10.3390\/s120202255","article-title":"Gait analysis using wearable sensors","volume":"12","author":"Tao","year":"2012","journal-title":"Sensors"},{"issue":"10","key":"10.1016\/j.array.2026.100778_bib8","doi-asserted-by":"crossref","first-page":"1364","DOI":"10.1016\/j.medengphy.2008.09.005","article-title":"Direct measurement of human movement by accelerometry","volume":"30","author":"Godfrey","year":"2008","journal-title":"Med Eng Phys"},{"issue":"1","key":"10.1016\/j.array.2026.100778_bib9","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1038\/s41746-019-0090-4","article-title":"Developing and adopting safe and effective digital biomarkers to improve patient outcomes","volume":"2","author":"Coravos","year":"2019","journal-title":"npj Digit Med"},{"issue":"1","key":"10.1016\/j.array.2026.100778_bib10","doi-asserted-by":"crossref","first-page":"1674","DOI":"10.1038\/s41597-025-05959-w","article-title":"A dataset of clinical gait signals with wearable sensors from healthy, neurological, and orthopedic cohorts","volume":"12","author":"Voisard","year":"2025","journal-title":"Sci Data"},{"issue":"6","key":"10.1016\/j.array.2026.100778_bib11","doi-asserted-by":"crossref","first-page":"1765","DOI":"10.1109\/JBHI.2018.2865218","article-title":"Imu-based classification of parkinson's disease from gait: a sensitivity analysis on sensor location and feature selection","volume":"22","author":"Caramia","year":"2018","journal-title":"IEEE J Biomed Health Inform"},{"key":"10.1016\/j.array.2026.100778_bib12","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.gaitpost.2016.08.012","article-title":"Gait event detection in laboratory and real life settings: accuracy of ankle and waist sensor based methods","volume":"50","author":"Storm","year":"2016","journal-title":"Gait Posture"},{"key":"10.1016\/j.array.2026.100778_bib13","series-title":"Overview of measurement methods of inter-limb coordination","author":"Van Parijs","year":"2019"},{"key":"10.1016\/j.array.2026.100778_bib14","article-title":"Deep, convolutional, and recurrent models for human activity recognition using wearables","author":"Hammerla","year":"2016","journal-title":"arXiv preprint arXiv:160408880"},{"issue":"1","key":"10.1016\/j.array.2026.100778_bib15","doi-asserted-by":"crossref","first-page":"115","DOI":"10.3390\/s16010115","article-title":"Deep convolutional and lstm recurrent neural networks for multimodal wearable activity recognition","volume":"16","author":"Ord\u00f3\u00f1ez","year":"2016","journal-title":"Sensors"},{"issue":"5","key":"10.1016\/j.array.2026.100778_bib16","doi-asserted-by":"crossref","first-page":"1824","DOI":"10.1109\/JBHI.2020.3025049","article-title":"Wearables and deep learning classify fall risk from gait in multiple sclerosis","volume":"25","author":"Meyer","year":"2020","journal-title":"IEEE J Biomed Health Inform"},{"key":"10.1016\/j.array.2026.100778_bib17","article-title":"Neural machine translation by jointly learning to align and translate","author":"Bahdanau","year":"2014","journal-title":"arXiv preprint arXiv:14090473"},{"key":"10.1016\/j.array.2026.100778_bib18","first-page":"3109","article-title":"Attnsense: multi-level attention mechanism for multimodal human activity recognition","author":"Ma","year":"2019","journal-title":"In IJCAI"},{"key":"10.1016\/j.array.2026.100778_bib19","article-title":"Attention is not explanation","author":"Jain","year":"2019","journal-title":"arXiv preprint arXiv:190210186"},{"key":"10.1016\/j.array.2026.100778_bib20","series-title":"Is attention interpretable? arXiv preprint arXiv:1906.03731","author":"Serrano","year":"2019"},{"key":"10.1016\/j.array.2026.100778_bib21","article-title":"Attention is not not explanation","author":"Wiegreffe","year":"2019","journal-title":"arXiv preprint arXiv:190804626"},{"key":"10.1016\/j.array.2026.100778_bib22","series-title":"Conference on health, inference, and learning","first-page":"289","article-title":"When attention fails: pitfalls of attention-based model interpretability for high-dimensional clinical time-series","author":"Yadav","year":"2025"},{"issue":"6464","key":"10.1016\/j.array.2026.100778_bib23","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1126\/science.aax2342","article-title":"Dissecting racial bias in an algorithm used to manage the health of populations","volume":"366","author":"Obermeyer","year":"2019","journal-title":"Science"},{"issue":"11","key":"10.1016\/j.array.2026.100778_bib24","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1038\/s42256-020-00257-z","article-title":"Shortcut learning in deep neural networks","volume":"2","author":"Geirhos","year":"2020","journal-title":"Nat Mach Intell"},{"issue":"11","key":"10.1016\/j.array.2026.100778_bib25","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pmed.1002683","article-title":"Variable generalization performance of a deep learning model to detect pneumonia in chest radiographs: a cross-sectional study","volume":"15","author":"Zech","year":"2018","journal-title":"PLoS Med"},{"issue":"11","key":"10.1016\/j.array.2026.100778_bib26","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pmed.1002689","article-title":"Machine learning in medicine: addressing ethical challenges","volume":"15","author":"Vayena","year":"2018","journal-title":"PLoS Med"},{"issue":"14","key":"10.1016\/j.array.2026.100778_bib27","doi-asserted-by":"crossref","first-page":"1347","DOI":"10.1056\/NEJMra1814259","article-title":"Machine learning in medicine","volume":"380","author":"Rajkomar","year":"2019","journal-title":"N Engl J Med"},{"issue":"1","key":"10.1016\/j.array.2026.100778_bib28","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1186\/s12916-019-1426-2","article-title":"Key challenges for delivering clinical impact with artificial intelligence","volume":"17","author":"Kelly","year":"2019","journal-title":"BMC Med"},{"issue":"3","key":"10.1016\/j.array.2026.100778_bib29","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1038\/s42256-021-00307-0","article-title":"Common pitfalls and recommendations for using machine learning to detect and prognosticate for covid-19 using chest radiographs and ct scans","volume":"3","author":"Roberts","year":"2021","journal-title":"Nat Mach Intell"},{"issue":"1","key":"10.1016\/j.array.2026.100778_bib30","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1186\/s12916-025-04340-3","article-title":"Navigating fairness aspects of clinical prediction models","volume":"23","author":"Chakradeo","year":"2025","journal-title":"BMC Med"},{"issue":"2","key":"10.1016\/j.array.2026.100778_bib31","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.gaitpost.2012.07.012","article-title":"Quantitative estimation of foot-flat and stance phase of gait using foot-worn inertial sensors","volume":"37","author":"Mariani","year":"2013","journal-title":"Gait Posture"},{"issue":"4","key":"10.1016\/j.array.2026.100778_bib32","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1145\/2382577.2382579","article-title":"Leakage in data mining: formulation, detection, and avoidance","volume":"6","author":"Kaufman","year":"2012","journal-title":"ACM Trans Knowl Discov Data"},{"key":"10.1016\/j.array.2026.100778_bib33","series-title":"Proceedings of the 27th ACM SIGKDD conference on knowledge discovery & data mining","first-page":"2114","article-title":"A transformer- based framework for multivariate time series representation learning","author":"George","year":"2021"},{"key":"10.1016\/j.array.2026.100778_bib34","series-title":"Machine learning for health (ML4H)","first-page":"623","article-title":"Transehr: self-supervised transformer for clinical time series data","author":"Xu","year":"2023"},{"issue":"1","key":"10.1016\/j.array.2026.100778_bib35","doi-asserted-by":"crossref","first-page":"6010","DOI":"10.1038\/s41467-020-19784-9","article-title":"Training confounder-free deep learning models for medical applications","volume":"11","author":"Zhao","year":"2020","journal-title":"Nat Commun"}],"container-title":["Array"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2590005626001013?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2590005626001013?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T09:11:46Z","timestamp":1777367506000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2590005626001013"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":35,"alternative-id":["S2590005626001013"],"URL":"https:\/\/doi.org\/10.1016\/j.array.2026.100778","relation":{},"ISSN":["2590-0056"],"issn-type":[{"value":"2590-0056","type":"print"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Task-specific sensor discovery through attention-based deep learning: Enabling automated dataset auditing for clinical gait analysis","name":"articletitle","label":"Article Title"},{"value":"Array","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.array.2026.100778","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author. Published by Elsevier Inc.","name":"copyright","label":"Copyright"}],"article-number":"100778"}}