{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T10:26:39Z","timestamp":1772792799396,"version":"3.50.1"},"reference-count":53,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2014,2,1]],"date-time":"2014-02-01T00:00:00Z","timestamp":1391212800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"name":"joint Polish-French \u201cPolonium\u201d","award":["PL2405\/F01577XM"],"award-info":[{"award-number":["PL2405\/F01577XM"]}]},{"name":"Polish Ministry of Science and Information Society Technologies","award":["3P05C 009 23"],"award-info":[{"award-number":["3P05C 009 23"]}]}],"content-domain":{"domain":["aiimjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Artificial Intelligence in Medicine"],"published-print":{"date-parts":[[2014,2]]},"DOI":"10.1016\/j.artmed.2013.12.004","type":"journal-article","created":{"date-parts":[[2014,1,2]],"date-time":"2014-01-02T22:22:56Z","timestamp":1388701376000},"page":"113-121","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":17,"title":["Fuzzy logic-based diagnostic algorithm for implantable cardioverter defibrillators"],"prefix":"10.1016","volume":"60","author":[{"given":"Andr\u00e1s","family":"B\u00e1rdossy","sequence":"first","affiliation":[]},{"given":"Aleksandra","family":"Blinowska","sequence":"additional","affiliation":[]},{"given":"Wieslaw","family":"Kuzmicz","sequence":"additional","affiliation":[]},{"given":"Jacky","family":"Ollitrault","sequence":"additional","affiliation":[]},{"given":"Micha\u0142","family":"Lewandowski","sequence":"additional","affiliation":[]},{"given":"Andrzej","family":"Przybylski","sequence":"additional","affiliation":[]},{"given":"Zbigniew","family":"Jaworski","sequence":"additional","affiliation":[]}],"member":"78","reference":[{"key":"10.1016\/j.artmed.2013.12.004_bib0005","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1109\/5.486745","article-title":"Detection algorithms in implantable cardioverter defibrillators","volume":"84","author":"Jenkins","year":"1996","journal-title":"Proc IEEE"},{"key":"10.1016\/j.artmed.2013.12.004_bib0010","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1016\/j.eupc.2004.02.005","article-title":"Arrhythmia detection by dual-chamber implantable cardioverter defibrillators. A review of current algorithms","volume":"6","author":"Aliot","year":"2004","journal-title":"Europace"},{"key":"10.1016\/j.artmed.2013.12.004_bib0015","doi-asserted-by":"crossref","first-page":"S123","DOI":"10.1016\/j.jelectrocard.2007.05.031","article-title":"Detection of cardiac tachyarrhythmias in implantable devices","volume":"40","author":"Gillberg","year":"2007","journal-title":"J Electrocardiol"},{"key":"10.1016\/j.artmed.2013.12.004_bib0020","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1016\/j.jelectrocard.2010.06.009","article-title":"Improving contemporary algorithms for implantable cardioverter-defibrillator function","volume":"43","author":"Shome","year":"2010","journal-title":"J Electrocardiol"},{"key":"10.1016\/j.artmed.2013.12.004_bib0025","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1046\/j.1540-8167.2002.01092.x","article-title":"Advanced rhythm discrimination for implantable cardioverter defibrillators using electrogram vector timing and correlation","volume":"13","author":"Gold","year":"2002","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.artmed.2013.12.004_bib0030","series-title":"Proc. 30th annual Int Conf of the IEEE EMBS","first-page":"5478","article-title":"A covariance-based algorithm: a novel technique for rhythm discrimination in ICDs","author":"Kamousi","year":"2008"},{"key":"10.1016\/j.artmed.2013.12.004_bib0035","series-title":"Proc 31st annual Int Conf of the IEEE EMBS","first-page":"2478","article-title":"A new approach for ICD rhythm classification based on support vector machines","author":"Kamousi","year":"2009"},{"key":"10.1016\/j.artmed.2013.12.004_bib0040","doi-asserted-by":"crossref","first-page":"40D","DOI":"10.1016\/S0002-9149(98)00967-9","article-title":"Is inappropriate therapy a resolved issue with current implantable cardioverter defibrillators?","volume":"83","author":"Brugada","year":"1999","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.artmed.2013.12.004_bib0045","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1016\/S0002-8703(00)90010-3","article-title":"Inappropriate therapy from atrial fibrillation and sinus tachycardia in automated implantable cardioverter defibrillators","volume":"139","author":"Nanthakumar","year":"2000","journal-title":"Am Heart J"},{"key":"10.1016\/j.artmed.2013.12.004_bib0050","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1046\/j.1540-8167.2001.00134.x","article-title":"Do current dual chamber cardioverter defibrillators have advantages over conventional single chamber cardioverter defibrillators in reducing inappropriate therapies? A randomized, prospective study","volume":"12","author":"Deisenhofer","year":"2001","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.artmed.2013.12.004_bib0055","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1046\/j.1540-8167.2001.00606.x","article-title":"Supraventricular tachycardia-ventricular tachycardia discrimination algorithms in implantable cardioverter defibrillators: state-of-the-art review","volume":"12","author":"Swerdlow","year":"2001","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.artmed.2013.12.004_bib0060","first-page":"315","article-title":"Dual chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the dual chamber and VVI implantable defibrillator (DAVID) trial","volume":"288","author":"Wilkoff","year":"2002","journal-title":"JAMA"},{"key":"10.1016\/j.artmed.2013.12.004_bib0065","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.ijcard.2010.09.005","article-title":"Arrhythmia discrimination by physician and defibrillator: importance of atrial channel","volume":"154","author":"Diemberger","year":"2012","journal-title":"Int J Cardiol"},{"key":"10.1016\/j.artmed.2013.12.004_bib0070","doi-asserted-by":"crossref","first-page":"1511","DOI":"10.1046\/j.1460-9592.2003.t01-1-00219.x","article-title":"Mortality, morbidity, and complications in 3344 patients with implantable cardioverter defibrillators: results from the German ICD registry EURID","volume":"26","author":"Gradaus","year":"2003","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.artmed.2013.12.004_bib0075","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1111\/j.1540-8167.2006.00643.x","article-title":"Improving SVT discrimination in single-chamber ICDs: a new electrogram morphology-based algorithm","volume":"12","author":"Klein","year":"2006","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.artmed.2013.12.004_bib0080","doi-asserted-by":"crossref","first-page":"1255","DOI":"10.1111\/j.1540-8159.2006.00521.x","article-title":"Wavelet-based tachycardia discrimination in ICDs: impact of posture and electrogram configuration","volume":"11","author":"Wolber","year":"2006","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.artmed.2013.12.004_bib0085","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1093\/europace\/eup099","article-title":"Morphology discrimination criterion wavelet improves rhythm discrimination in single-chamber implantable cardioverter-defibrillators: Spanish Register of morphology discrimination criterion wavelet (REMEDIO)","volume":"11","author":"Toquero","year":"2009","journal-title":"Europace"},{"key":"10.1016\/j.artmed.2013.12.004_bib0090","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1007\/s11517-006-0119-0","article-title":"Heart rate variability: a review","volume":"44","author":"Acharya","year":"2006","journal-title":"Med Biol Eng Comp"},{"key":"10.1016\/j.artmed.2013.12.004_bib0095","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1111\/j.1540-8159.1995.tb02564.x","article-title":"Programmable VT detection enhancements in implantable cardioverter defibrillator therapy","volume":"18","author":"Neuzner","year":"1995","journal-title":"PACE"},{"key":"10.1016\/j.artmed.2013.12.004_bib0100","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1161\/01.CIR.93.2.295","article-title":"RR interval variability in irregular monomorphic ventricular tachycardia and atrial fibrillation","volume":"93","author":"Garcia-Alberola","year":"1996","journal-title":"Circulation"},{"key":"10.1016\/j.artmed.2013.12.004_bib0105","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1046\/j.1540-8167.2002.00432.x","article-title":"Discrimination of ventricular tachycardia from supraventricular tachycardia by a downloaded wavelet-transform morphology algorithm: a paradigm for development of implantable cardioverter defibrillator detection algorithms","volume":"13","author":"Swerdlow","year":"2002","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.artmed.2013.12.004_bib0110","series-title":"Proc 19th Int Conf IEEE\/EMBS","first-page":"393","article-title":"Recognition of ventricular tachycardia with 1:1 retrograde atrial activation: a new algorithm for implantable cardioverter defibrillators","author":"Thompson","year":"1997"},{"key":"10.1016\/j.artmed.2013.12.004_bib0115","doi-asserted-by":"crossref","first-page":"1357","DOI":"10.1046\/j.1460-9592.2002.01357.x","article-title":"Combined use of morphology discrimination, sudden onset, and stability as discriminating algorithms in single chamber cardioverter defibrillators","volume":"25","author":"Boriani","year":"2002","journal-title":"PACE"},{"key":"10.1016\/j.artmed.2013.12.004_bib0120","series-title":"Computers in cardiology 1997","first-page":"247","article-title":"Differentiation of supraventricular and ventricular arrhythmias based on morphological analysis of ICD stored electrograms","author":"Millet","year":"1997"},{"key":"10.1016\/j.artmed.2013.12.004_bib0125","series-title":"Proc IEEE 24th annual northeast bioengineering Conf","first-page":"21","article-title":"Ventricular arrhythmia detection using time-domain template algorithms","author":"Schuckers","year":"1998"},{"key":"10.1016\/j.artmed.2013.12.004_bib0130","series-title":"Computers in cardiology 1999","first-page":"347","article-title":"Distinction of arrhythmias with the use of approximate entropy","author":"Caswell Schuckers","year":"1999"},{"key":"10.1016\/j.artmed.2013.12.004_bib0135","series-title":"Computers in cardiology 2003","first-page":"729","article-title":"Distinction of ventricular fibrillation and ventricular tachycardia using cross correlation","author":"Ruiz","year":"2003"},{"key":"10.1016\/j.artmed.2013.12.004_bib0140","first-page":"3703","article-title":"Symbolic dynamics analysis of short data sets: an application to heart rate variability from implantable defibrillator devices","volume":"34","author":"Zebrowski","year":"2003","journal-title":"Acta Phys Pol B"},{"key":"10.1016\/j.artmed.2013.12.004_bib0145","series-title":"Proc of the sixteenth national radio science Conf","article-title":"Design of a VLSI neural network arrhythmia classifier","author":"Shawkey","year":"1999"},{"key":"10.1016\/j.artmed.2013.12.004_bib0150","doi-asserted-by":"crossref","first-page":"1599","DOI":"10.1046\/j.1460-9592.2002.01599.x","article-title":"Automatic discrimination between supraventricular and ventricular tachycardia using a multilayer perceptron in implantable cardioverter defibrillators","volume":"25","author":"Rojo-\u00c1lvarez","year":"2002","journal-title":"PACE"},{"key":"10.1016\/j.artmed.2013.12.004_bib0155","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.artmed.2011.09.004","article-title":"Selection of effective features for ECG beat recognition based on nonlinear correlations","volume":"54","author":"Chen","year":"2012","journal-title":"Artif Intell Med"},{"key":"10.1016\/j.artmed.2013.12.004_bib0160","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.artmed.2008.04.007","article-title":"Support vector machine-based arrhythmia classification using reduced features of heart rate variability signal","volume":"44","author":"Asl","year":"2008","journal-title":"Artif Intell Med"},{"key":"10.1016\/j.artmed.2013.12.004_bib0165","series-title":"Proc 18th annual Int Conf of the IEEE EMBS","first-page":"997","article-title":"Fuzzy classification of intra-cardiac arrhythmias","author":"Usher","year":"1996"},{"key":"10.1016\/j.artmed.2013.12.004_bib0170","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.artmed.2007.04.001","article-title":"A methodology for the automated creation of fuzzy expert systems for ischaemic and arrhythmic beat classification based on a set of rules obtained by a decision tree","volume":"40","author":"Exarchos","year":"2007","journal-title":"Artif Intell Med"},{"key":"10.1016\/j.artmed.2013.12.004_bib0175","series-title":"Proc 23rd annual EMBS Int Conf","first-page":"3863","article-title":"Scalar fuzzy logic a new mathematical model for approximate reasoning","author":"Mlynski","year":"2001"},{"key":"10.1016\/j.artmed.2013.12.004_bib0180","series-title":"Proc 25th annual Int Conf of the IEEE EMBS","first-page":"1291","article-title":"Using scalar fuzzy control for aggregation problems in knowledge based diagnosis for implantable devices","author":"Mlynski","year":"2003"},{"key":"10.1016\/j.artmed.2013.12.004_bib0185","series-title":"Proc 30th annual Int IEEE EMBS Conf","first-page":"2673","article-title":"FPGA-core defibrillator using wavelet-fuzzy ECG arrhythmia classification","author":"Nambakhsh","year":"2008"},{"key":"10.1016\/j.artmed.2013.12.004_bib0190","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.1109\/10.959322","article-title":"ECG beat recognition using fuzzy hybrid neural network","volume":"48","author":"Osowski","year":"2001","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.artmed.2013.12.004_bib0195","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/S0031-3203(02)00063-8","article-title":"Classification of heart rate data using artificial neural network and fuzzy equivalence relation","volume":"36","author":"Acharya","year":"2003","journal-title":"Pattern Recognit"},{"key":"10.1016\/j.artmed.2013.12.004_bib0200","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.artmed.2004.03.007","article-title":"An arrhythmia classification system based on the RR-interval signal","volume":"33","author":"Tsipouras","year":"2005","journal-title":"Artif Intell Med"},{"key":"10.1016\/j.artmed.2013.12.004_bib0205","series-title":"Computers in cardiology 2002","first-page":"485","article-title":"Arrhythmia classification using the RR-interval duration signal","author":"Tsipouras","year":"2002"},{"key":"10.1016\/j.artmed.2013.12.004_bib0210","series-title":"Proc 29th annual Int Conf of the IEEE EMBS","first-page":"1291","article-title":"Integration of global and local knowledge for fuzzy expert system creation \u2013 application to arrhythmic beat classification","author":"Tsipouras","year":"2007"},{"key":"10.1016\/j.artmed.2013.12.004_bib0215","doi-asserted-by":"crossref","first-page":"2089","DOI":"10.1109\/TBME.2007.893500","article-title":"A framework for fuzzy expert system creation\u2014application to cardiovascular diseases","volume":"54","author":"Tsipouras","year":"2007","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.artmed.2013.12.004_bib0220","series-title":"Computers in cardiology 2004","first-page":"361","article-title":"A method for arrhythmic episode classification in ECGs using fuzzy logic and Markov models","author":"Tsipouras","year":"2004"},{"key":"10.1016\/j.artmed.2013.12.004_bib0225","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1109\/10.942588","article-title":"A short-time multifractal approach for arrhythmia detection based on fuzzy neural network","volume":"48","author":"Wang","year":"2001","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.artmed.2013.12.004_bib0230","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1093\/europace\/eul119","article-title":"Performance of a new single-chamber ICD algorithm: discrimination of supraventricular and ventricular tachycardia based on vector timing and correlation","volume":"8","author":"Corbisiero","year":"2006","journal-title":"Europace"},{"key":"10.1016\/j.artmed.2013.12.004_bib0235","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1161\/01.CIR.101.23.e215","article-title":"PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals","volume":"101","author":"Goldberger","year":"2000","journal-title":"Circulation"},{"key":"10.1016\/j.artmed.2013.12.004_bib0240","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1109\/51.932724","article-title":"The impact of the MIT-BIH arrhythmia database","volume":"20","author":"Moody","year":"2001","journal-title":"IEEE Eng Med Biol"},{"key":"10.1016\/j.artmed.2013.12.004_bib0245","series-title":"Improved detection and classification of arrhythmias in noise-corrupted electrocardiograms using contextual information","author":"Greenwald","year":"1990"},{"key":"10.1016\/j.artmed.2013.12.004_bib0250","series-title":"WFDB applications guide","author":"Moody","year":"2013"},{"key":"10.1016\/j.artmed.2013.12.004_bib0255","series-title":"MIXDES 2004 Conf","first-page":"263","article-title":"Diffusion programmable ROM layout compiler","author":"Grodzicki","year":"2004"},{"key":"10.1016\/j.artmed.2013.12.004_bib0260","series-title":"MIXDES 2004 Conf","first-page":"579","article-title":"Hardware implementation of fuzzy logic based diagnostic algorithm for implantable cardioverter defibrillators","author":"Muzal","year":"2004"},{"key":"10.1016\/j.artmed.2013.12.004_bib0265","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1111\/anec.12090","article-title":"Reduction of the inappropriate ICD therapies by implementing a new fuzzy logic based diagnostic algorithm","volume":"18","author":"Lewandowski","year":"2013","journal-title":"Ann Noninvasive Electrocardiol"}],"container-title":["Artificial Intelligence in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0933365713001644?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0933365713001644?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,10,7]],"date-time":"2018-10-07T16:22:49Z","timestamp":1538929369000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0933365713001644"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,2]]},"references-count":53,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2014,2]]}},"alternative-id":["S0933365713001644"],"URL":"https:\/\/doi.org\/10.1016\/j.artmed.2013.12.004","relation":{},"ISSN":["0933-3657"],"issn-type":[{"value":"0933-3657","type":"print"}],"subject":[],"published":{"date-parts":[[2014,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Fuzzy logic-based diagnostic algorithm for implantable cardioverter defibrillators","name":"articletitle","label":"Article Title"},{"value":"Artificial Intelligence in Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.artmed.2013.12.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2013 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}