{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,8]],"date-time":"2026-04-08T22:15:26Z","timestamp":1775686526576,"version":"3.50.1"},"reference-count":29,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2015,3,1]],"date-time":"2015-03-01T00:00:00Z","timestamp":1425168000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2015,3,1]],"date-time":"2015-03-01T00:00:00Z","timestamp":1425168000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100000854","name":"Human Frontier Science Program","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000854","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Computers in Biology and Medicine"],"published-print":{"date-parts":[[2015,3]]},"DOI":"10.1016\/j.compbiomed.2015.01.002","type":"journal-article","created":{"date-parts":[[2015,1,10]],"date-time":"2015-01-10T01:47:23Z","timestamp":1420854443000},"page":"56-62","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"special_numbering":"C","title":["Development and validation of an open source quantification tool for DSC-MRI studies"],"prefix":"10.1016","volume":"58","author":[{"given":"P.M.","family":"Gordaliza","sequence":"first","affiliation":[]},{"given":"J.M.","family":"Mateos-P\u00e9rez","sequence":"additional","affiliation":[]},{"given":"P.","family":"Montesinos","sequence":"additional","affiliation":[]},{"given":"J.A.","family":"Guzm\u00e1n-de-Villoria","sequence":"additional","affiliation":[]},{"given":"M.","family":"Desco","sequence":"additional","affiliation":[]},{"given":"J.J.","family":"Vaquero","sequence":"additional","affiliation":[]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.compbiomed.2015.01.002_bib1","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1148\/radiology.191.1.8134596","article-title":"Cerebral blood volume maps of gliomas: comparison with tumor grade and histologic findings","volume":"191","author":"Aronen","year":"1994","journal-title":"Radiology"},{"key":"10.1016\/j.compbiomed.2015.01.002_bib2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.pnmrs.2013.04.002","article-title":"Arterial input function in perfusion MRI: a comprehensive review","volume":"74","author":"Calamante","year":"2013","journal-title":"Prog. Nucl. Magn. Reson. Spectrosc."},{"issue":"2","key":"10.1016\/j.compbiomed.2015.01.002_bib3","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1148\/radiol.2272020092","article-title":"Automatic calculation of the arterial input function for cerebral perfusion imaging with MR imaging","volume":"227","author":"Carroll","year":"2003","journal-title":"Radiology"},{"key":"10.1016\/j.compbiomed.2015.01.002_bib4","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1016\/S0360-3016(01)01691-1","article-title":"Tumor angiogenesis of low-grade astrocytomas measured by dynamic susceptibility contrast-enhanced MRI (DSC-MRI) is predictive of local tumor control after radiation therapy","volume":"51","author":"Fuss","year":"2001","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"4","key":"10.1016\/j.compbiomed.2015.01.002_bib5","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1002\/mrm.20850","article-title":"Iterative blind deconvolution in magnetic resonance brain perfusion imaging","volume":"55","author":"Gruner","year":"2006","journal-title":"Magn. Reson. Med."},{"issue":"3","key":"10.1016\/j.compbiomed.2015.01.002_bib6","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.rx.2011.06.003","article-title":"Studying cerebral perfusion using magnetic susceptibility techniques: technique and applications","volume":"54","author":"Guzm\u00e1n-de-Villoria","year":"2012","journal-title":"Radiologia"},{"issue":"5","key":"10.1016\/j.compbiomed.2015.01.002_bib7","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1002\/(SICI)1522-2586(200005)11:5<495::AID-JMRI5>3.0.CO;2-S","article-title":"Dynamic susceptibility contrast MR imaging of plaque development in multiple sclerosis: application of an extended blood\u2013brain barrier leakage correction","volume":"11","author":"Haselhorst","year":"2000","journal-title":"J. Magn. Reson. Imaging"},{"issue":"4","key":"10.1016\/j.compbiomed.2015.01.002_bib8","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1038\/jcbfm.2013.241","article-title":"Cerebral blood flow is an earlier indicator of perfusion abnormalities than cerebral blood volume in Alzheimer\u2019s disease","volume":"34","author":"Lacalle-Aurioles","year":"2014","journal-title":"J. Cereb. Blood Flow Metab.: official journal of the International Society of Cerebral Blood Flow and Metabolism"},{"issue":"5","key":"10.1016\/j.compbiomed.2015.01.002_bib9","first-page":"746","article-title":"Comparison of cerebral blood volume and vascular permeability from dynamic susceptibility contrast-enhanced perfusion MR imaging with glioma grade","volume":"25","author":"Law","year":"2004","journal-title":"AJNR Am. J. Neuroradiol."},{"issue":"5","key":"10.1016\/j.compbiomed.2015.01.002_bib10","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1016\/S0730-725X(03)00075-4","article-title":"Adaptive total linear least square method for quantification of mean transit time in brain perfusion MRI","volume":"21","author":"Li","year":"2003","journal-title":"Magn. Reson. Imaging"},{"key":"10.1016\/j.compbiomed.2015.01.002_bib11","unstructured":"Lund University, F. of M., 2004. LUPE: the Lund Perfusion Program. Available at: \u3008http:\/\/www.med.lu.se\/klinvetlund\/mr_physics\/software\/lupe_overview\u3009 [Accessed May 16, 2014]."},{"issue":"6","key":"10.1016\/j.compbiomed.2015.01.002_bib12","first-page":"1446","article-title":"Dynamic susceptibility-weighted perfusion imaging of high-grade gliomas: characterization of spatial heterogeneity","volume":"26","author":"Lupo","year":"2005","journal-title":"AJNR Am. J. Neuroradiol."},{"issue":"1","key":"10.1016\/j.compbiomed.2015.01.002_bib13","doi-asserted-by":"crossref","first-page":"181","DOI":"10.2214\/ajr.163.1.8010210","article-title":"Vascularity of meningiomas and neuromas: assessment with dynamic susceptibility-contrast MR imaging","volume":"163","author":"Maeda","year":"1994","journal-title":"AJR Am. J. Roentgenol."},{"key":"10.1016\/j.compbiomed.2015.01.002_bib14","doi-asserted-by":"crossref","unstructured":"Mateos-P\u00e9rez, J.M. et al., 2013. jClustering, an open framework for the development of 4D clustering algorithms L. Martens, (Ed.), PLoS One, 8(8), e70797. Available at: \u3008http:\/\/dx.plos.org\/10.1371\/journal.pone.0070797\u3009 [Accessed August 23, 2013].","DOI":"10.1371\/journal.pone.0070797"},{"issue":"1","key":"10.1016\/j.compbiomed.2015.01.002_bib15","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1093\/neuonc\/noq150","article-title":"Dynamic magnetic resonance imaging assessment of vascular targeting agent effects in rat intracerebral tumor models","volume":"13","author":"Muldoon","year":"2011","journal-title":"Neuro-oncology"},{"issue":"5","key":"10.1016\/j.compbiomed.2015.01.002_bib16","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1002\/mrm.1910360510","article-title":"High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis","volume":"36","author":"Ostergaard","year":"1996","journal-title":"Magn. Reson. Med."},{"issue":"5","key":"10.1016\/j.compbiomed.2015.01.002_bib17","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1002\/mrm.1910360511","article-title":"High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part II: Experimental comparison and preliminary results","volume":"36","author":"Ostergaard","year":"1996","journal-title":"Magn. Reson. Med."},{"issue":"12","key":"10.1016\/j.compbiomed.2015.01.002_bib18","doi-asserted-by":"crossref","first-page":"6380","DOI":"10.1118\/1.3658570","article-title":"An improved model for describing the contrast bolus in perfusion MRI","volume":"38","author":"Patil","year":"2011","journal-title":"Med. Phys."},{"issue":"2","key":"10.1016\/j.compbiomed.2015.01.002_bib19","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1148\/radiol.2492071659","article-title":"Comparison of dynamic susceptibility-weighted contrast-enhanced MR methods: recommendations for measuring relative cerebral blood volume in brain","volume":"249","author":"Paulson","year":"2008","journal-title":"Radiology"},{"issue":"3","key":"10.1016\/j.compbiomed.2015.01.002_bib20","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1002\/mrm.21931","article-title":"High-resolution longitudinal assessment of flow and permeability in mouse glioma vasculature: sequential small molecule and SPIO dynamic contrast agent MRI","volume":"61","author":"Pike","year":"2009","journal-title":"Magn. Reson. Med.: official journal of the Society of Magnetic Resonance in Medicine \/ Society of Magnetic Resonance in Medicine"},{"issue":"3","key":"10.1016\/j.compbiomed.2015.01.002_bib21","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1148\/radiology.193.3.7972800","article-title":"Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging","volume":"193","author":"Rempp","year":"1994","journal-title":"Radiology"},{"key":"10.1016\/j.compbiomed.2015.01.002_bib22","first-page":"671","article-title":"NIH Image to ImageJ: 25 years of image analysis","volume":"9","author":"Schneider","year":"2012"},{"issue":"3","key":"10.1016\/j.compbiomed.2015.01.002_bib23","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1002\/1522-2586(200009)12:3<400::AID-JMRI5>3.0.CO;2-C","article-title":"Whole brain quantitative CBF, CBV, and MTT measurements using MRI bolus tracking: implementation and application to data acquired from hyperacute stroke patients","volume":"12","author":"Smith","year":"2000","journal-title":"J. Magn. Reson. Imaging"},{"issue":"1","key":"10.1016\/j.compbiomed.2015.01.002_bib24","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1002\/jmri.1880070108","article-title":"Contrast agents in functional MR imaging","volume":"7","author":"Sorensen","year":"1997","journal-title":"J Magn Reson Imaging"},{"issue":"2","key":"10.1016\/j.compbiomed.2015.01.002_bib25","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.jneumeth.2008.04.022","article-title":"Dynamic contrast-enhanced susceptibility-weighted perfusion MRI (DSC-MRI) in a glioma model of the rat brain using a conventional receive-only surface coil with a inner diameter of 47mm at a clinical 1.5T scanner","volume":"172","author":"Ulmer","year":"2008","journal-title":"J. Neurosci. Methods"},{"issue":"4","key":"10.1016\/j.compbiomed.2015.01.002_bib26","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1038\/jcbfm.2008.162","article-title":"Dynamic MRI using iron oxide nanoparticles to assess early vascular effects of antiangiogenic versus corticosteroid treatment in a glioma model","volume":"29","author":"Varallyay","year":"2009","journal-title":"J. Cereb. Blood Flow Metab.: official journal of the International Society of Cerebral Blood Flow and Metabolism"},{"issue":"2","key":"10.1016\/j.compbiomed.2015.01.002_bib27","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1002\/(SICI)1522-2586(199908)10:2<109::AID-JMRI1>3.0.CO;2-#","article-title":"Measurement of cerebral perfusion with dual-echo multi-slice quantitative dynamic susceptibility contrast MRI","volume":"10","author":"Vonken","year":"1999","journal-title":"J. Magn. Reson. Imaging"},{"issue":"6","key":"10.1016\/j.compbiomed.2015.01.002_bib28","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1002\/1522-2594(200006)43:6<820::AID-MRM7>3.0.CO;2-F","article-title":"Simultaneous quantitative cerebral perfusion and Gd-DTPA extravasation measurement with dual-echo dynamic susceptibility contrast MRI","volume":"43","author":"Vonken","year":"2000","journal-title":"Magn. Reson. Med."},{"issue":"2","key":"10.1016\/j.compbiomed.2015.01.002_bib29","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1007\/s10278-012-9510-6","article-title":"UMMPerfusion: an open source software tool towards quantitative mri perfusion analysis in clinical routine","volume":"26","author":"Z\u00f6llner","year":"2013","journal-title":"J. Digit. Imaging"}],"container-title":["Computers in Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0010482515000050?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0010482515000050?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,14]],"date-time":"2025-09-14T19:18:20Z","timestamp":1757877500000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0010482515000050"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,3]]},"references-count":29,"alternative-id":["S0010482515000050"],"URL":"https:\/\/doi.org\/10.1016\/j.compbiomed.2015.01.002","relation":{},"ISSN":["0010-4825"],"issn-type":[{"value":"0010-4825","type":"print"}],"subject":[],"published":{"date-parts":[[2015,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Development and validation of an open source quantification tool for DSC-MRI studies","name":"articletitle","label":"Article Title"},{"value":"Computers in Biology and Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.compbiomed.2015.01.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}