{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T20:52:06Z","timestamp":1781556726342,"version":"3.54.5"},"reference-count":25,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,2,20]],"date-time":"2026-02-20T00:00:00Z","timestamp":1771545600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["IFAC Journal of Systems and Control"],"published-print":{"date-parts":[[2026,3]]},"DOI":"10.1016\/j.ifacsc.2026.100393","type":"journal-article","created":{"date-parts":[[2026,2,23]],"date-time":"2026-02-23T16:25:03Z","timestamp":1771863903000},"page":"100393","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["A robust tube-based MPC approach for safer insulin dosing"],"prefix":"10.1016","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-1986-3417","authenticated-orcid":false,"given":"Nicola","family":"Licini","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcelo Alves","family":"Santos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabio","family":"Previdi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Ferramosca","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ifacsc.2026.100393_b1","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.jprocont.2020.06.009","article-title":"Artificial pancreas under stable pulsatile MPC: improving the closed-loop performance","volume":"92","author":"Abuin","year":"2020","journal-title":"Journal of Process Control"},{"issue":"Supplement_1","key":"10.1016\/j.ifacsc.2026.100393_b2","doi-asserted-by":"crossref","first-page":"S61","DOI":"10.2337\/dc19-S006","article-title":"6. Glycemic targets: standards of medical care in diabetes\u20142019","volume":"42","author":"American Diabetes Association","year":"2018","journal-title":"Diabetes Care"},{"issue":"1","key":"10.1016\/j.ifacsc.2026.100393_b3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s12532-018-0139-4","article-title":"CasADi: A software framework for nonlinear optimization and optimal control","volume":"11","author":"Andersson","year":"2019","journal-title":"Mathematical Programming Computation"},{"key":"10.1016\/j.ifacsc.2026.100393_b4","series-title":"2022 IEEE 61st conference on decision and control","first-page":"2566","article-title":"Enabling anticipatory response in multi-stage MPC formulation for fully automated artificial pancreas system","author":"Colmegna","year":"2022"},{"key":"10.1016\/j.ifacsc.2026.100393_b5","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.compag.2018.06.004","article-title":"Model predictive control and its application in agriculture: A review","volume":"151","author":"Ding","year":"2018","journal-title":"Computers and Electronics in Agriculture"},{"key":"10.1016\/j.ifacsc.2026.100393_b6","doi-asserted-by":"crossref","DOI":"10.1016\/j.automatica.2020.109105","article-title":"Homothetic tube-based robust offset-free economic model predictive control","volume":"119","author":"Dong","year":"2020","journal-title":"Automatica"},{"key":"10.1016\/j.ifacsc.2026.100393_b7","article-title":"A tube-NMPC approach for robust control of glucose in type 1 diabetes mellitus","author":"Jia","year":"2024","journal-title":"IEEE Transactions on Automation Science and Engineering"},{"key":"10.1016\/j.ifacsc.2026.100393_b8","series-title":"2023 American control conference","first-page":"2034","article-title":"Output feedback stochastic MPC with hard input constraints","author":"Joa","year":"2023"},{"issue":"1","key":"10.1016\/j.ifacsc.2026.100393_b9","doi-asserted-by":"crossref","first-page":"17016","DOI":"10.1038\/nrdp.2017.16","article-title":"Type 1 diabetes mellitus","volume":"3","author":"Katsarou","year":"2017","journal-title":"Nature Reviews Disease Primers"},{"key":"10.1016\/j.ifacsc.2026.100393_b10","series-title":"Robust constraint satisfaction: Invariant sets and predictive control","author":"Kerrigan","year":"2000"},{"key":"10.1016\/j.ifacsc.2026.100393_b11","series-title":"52nd IEEE conference on decision and control","first-page":"2084","article-title":"Robust tube-based predictive control of blood glucose concentration in type 1 diabetes","author":"Kirchsteiger","year":"2013"},{"key":"10.1016\/j.ifacsc.2026.100393_b12","series-title":"Model predictive control of type 1 diabetes: an in silico trial","author":"Magni","year":"2007"},{"issue":"4","key":"10.1016\/j.ifacsc.2026.100393_b13","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1177\/193229680800200414","article-title":"Evaluating the efficacy of closed-loop glucose regulation via control-variability grid analysis","volume":"2","author":"Magni","year":"2008","journal-title":"Journal of Diabetes Science and Technology"},{"issue":"1","key":"10.1016\/j.ifacsc.2026.100393_b14","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1177\/1932296813514502","article-title":"The UVA\/PADOVA Type 1 diabetes simulator: new features","volume":"8","author":"Man","year":"2014","journal-title":"Journal of Diabetes Science and Technology"},{"issue":"2","key":"10.1016\/j.ifacsc.2026.100393_b15","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/j.automatica.2004.08.019","article-title":"Robust model predictive control of constrained linear systems with bounded disturbances","volume":"41","author":"Mayne","year":"2005","journal-title":"Automatica"},{"issue":"1","key":"10.1016\/j.ifacsc.2026.100393_b16","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1109\/MCS.2017.2766314","article-title":"Individualized model predictive control for the artificial pancreas: in silico evaluation of closed-loop glucose control","volume":"38","author":"Messori","year":"2018","journal-title":"IEEE Control Systems"},{"key":"10.1016\/j.ifacsc.2026.100393_b17","article-title":"MINIMED\u2122 670g SYSTEM USer GUIDE","author":"MiniMed","year":"2018","journal-title":"Medtronic MiniMed"},{"key":"10.1016\/j.ifacsc.2026.100393_b18","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.ast.2015.09.018","article-title":"Attitude control of an underactuated spacecraft using tube-based mpc approach","volume":"48","author":"Mirshams","year":"2016","journal-title":"Aerospace Science and Technology"},{"issue":"27","key":"10.1016\/j.ifacsc.2026.100393_b19","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.ifacol.2018.11.645","article-title":"Impact of carbohydrate counting errors on glycemic control in type 1 diabetes","volume":"51","author":"Reiterer","year":"2018","journal-title":"IFAC-PapersOnLine"},{"issue":"6","key":"10.1016\/j.ifacsc.2026.100393_b20","doi-asserted-by":"crossref","first-page":"1412","DOI":"10.1109\/TBME.2016.2590498","article-title":"Modeling day-to-day variability of glucose\u2013insulin regulation over 12-week home use of closed-loop insulin delivery","volume":"64","author":"Ruan","year":"2017","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"10.1016\/j.ifacsc.2026.100393_b21","series-title":"Optimal state estimation: Kalman, H infinity, and nonlinear approaches","author":"Simon","year":"2006"},{"issue":"12","key":"10.1016\/j.ifacsc.2026.100393_b22","first-page":"4491","article-title":"Direct measurement of pulsatile insulin secretion from the portal vein in human subjects","volume":"85","author":"Song","year":"2000","journal-title":"The Journal of Clinical Endocrinology & Metabolism"},{"key":"10.1016\/j.ifacsc.2026.100393_b23","series-title":"DMMS.R","author":"The Epsilon Group","year":"2016"},{"issue":"4","key":"10.1016\/j.ifacsc.2026.100393_b24","doi-asserted-by":"crossref","first-page":"928","DOI":"10.1177\/193229681300700415","article-title":"Dynamic insulin on board: incorporation of circadian insulin sensitivity variation","volume":"7","author":"Toffanin","year":"2013","journal-title":"Journal of Diabetes Science and Technology"},{"issue":"6","key":"10.1016\/j.ifacsc.2026.100393_b25","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1109\/TBME.2017.2746340","article-title":"Type-1 diabetes patient decision simulator for in silico testing safety and effectiveness of insulin treatments","volume":"65","author":"Vettoretti","year":"2018","journal-title":"IEEE Transactions on Biomedical Engineering"}],"container-title":["IFAC Journal of Systems and Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2468601826000337?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2468601826000337?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T19:54:28Z","timestamp":1781553268000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2468601826000337"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3]]},"references-count":25,"alternative-id":["S2468601826000337"],"URL":"https:\/\/doi.org\/10.1016\/j.ifacsc.2026.100393","relation":{},"ISSN":["2468-6018"],"issn-type":[{"value":"2468-6018","type":"print"}],"subject":[],"published":{"date-parts":[[2026,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A robust tube-based MPC approach for safer insulin dosing","name":"articletitle","label":"Article Title"},{"value":"IFAC Journal of Systems and Control","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ifacsc.2026.100393","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"100393"}}