{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T22:44:27Z","timestamp":1759963467137},"reference-count":18,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2004,3,1]],"date-time":"2004-03-01T00:00:00Z","timestamp":1078099200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Computers in Biology and Medicine"],"published-print":{"date-parts":[[2004,3]]},"DOI":"10.1016\/s0010-4825(03)00042-8","type":"journal-article","created":{"date-parts":[[2003,6,9]],"date-time":"2003-06-09T20:41:29Z","timestamp":1055191289000},"page":"141-152","source":"Crossref","is-referenced-by-count":5,"title":["Computer assisted optimization of an electromagnetic transducer design for implantable hearing aids"],"prefix":"10.1016","volume":"34","author":[{"given":"Christof","family":"Stieger","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniela","family":"W\u00e4ckerlin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hans","family":"Bernhard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Stahel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Kompis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rudolf","family":"H\u00e4usler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J\u00fcrgen","family":"Burger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"4","key":"10.1016\/S0010-4825(03)00042-8_BIB1","first-page":"409","article-title":"Current status and critical reflections on implantable hearing aids","volume":"20","author":"H\u00fcttenbrink","year":"1999","journal-title":"Am. J. Otol."},{"key":"10.1016\/S0010-4825(03)00042-8_BIB2","unstructured":"A.J. Maniglia, D.W. Proops (Eds.), Implantable electronic otologic devices: state of the art, Otolaryngol. Clin. North Am. 34(2) (2001) 1\u2013220."},{"issue":"2","key":"10.1016\/S0010-4825(03)00042-8_BIB3","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1016\/S0030-6665(05)70345-5","article-title":"The otologics MET ossicular stimulator","volume":"34","author":"Kasic","year":"2001","journal-title":"Otolaryngol. Clin. North Am."},{"issue":"2","key":"10.1016\/S0010-4825(03)00042-8_BIB4","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1016\/S0030-6665(05)70340-6","article-title":"Total implantation of the Implex TICA hearing amplifier implant for high frequency sensorineural hearing loss","volume":"34","author":"Zenner","year":"2001","journal-title":"Otolaryngol. Clin. North Am."},{"key":"10.1016\/S0010-4825(03)00042-8_BIB5","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1097\/00129492-200207000-00010","article-title":"Functional gain of already implanted hearing devices in patients with sensorineural hearin loss of varied origin end extent","volume":"23","author":"Junker","year":"2002","journal-title":"Otol. Neurolotol."},{"issue":"1","key":"10.1016\/S0010-4825(03)00042-8_BIB6","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/S0030-6665(20)30564-8","article-title":"Engineering principles of mechanical stimulation of the middle ear","volume":"28","author":"Ko","year":"1995","journal-title":"Otolaryngol. Clin. North Am."},{"key":"10.1016\/S0010-4825(03)00042-8_BIB7","series-title":"The Function and Mechanics of Normal, Diseased and Reconstructed Middle Ears","first-page":"353","article-title":"Middle ear electromagnetic implantable hearing device","author":"Hough","year":"2000"},{"key":"10.1016\/S0010-4825(03)00042-8_BIB8","doi-asserted-by":"crossref","unstructured":"M. Kompis, C Kuhn, M Affolter, U Brugger, R H\u00e4usler, Design considerations for a contactless electromagnetic transducer for implantable hearing aids, Proceedings of the Annual International Conference of IEEE Engineering Biological Society, Hong Kong, Vol. 20(6), 1998, pp. 3173\u20133176.","DOI":"10.1109\/IEMBS.1998.746167"},{"key":"10.1016\/S0010-4825(03)00042-8_BIB9","series-title":"Surgical Anatomy of the Temporal Bone","author":"Anson","year":"1992"},{"key":"10.1016\/S0010-4825(03)00042-8_BIB10","series-title":"Anatomy of the Temporal Bone with Surgical Implications","author":"Gulya","year":"1995"},{"key":"10.1016\/S0010-4825(03)00042-8_BIB11","series-title":"Basis for a New Semi-Implantable Electro-Magnetic Middle Ear Hearing Aid","author":"a Wengen","year":"1998"},{"issue":"4","key":"10.1016\/S0010-4825(03)00042-8_BIB12","first-page":"485","article-title":"Experimental study of the acoustic properties of incus replacement prostheses in a human temporal bone model","volume":"15","author":"Nishihara","year":"1994","journal-title":"Am. J. Otol."},{"issue":"1","key":"10.1016\/S0010-4825(03)00042-8_BIB13","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/S0196-0709(00)80111-8","article-title":"The effect of the \u201cfloating mass transducer\u201d in the middle ear on hearing sensitivity","volume":"21","author":"Snik","year":"2000","journal-title":"Am. J. Otol."},{"key":"10.1016\/S0010-4825(03)00042-8_BIB14","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1177\/000348940111000515","article-title":"Mass loading on the ossicles and middle ear function","volume":"110","author":"Gan","year":"2001","journal-title":"Ann. Otol. Rhinol. Laryngol."},{"key":"10.1016\/S0010-4825(03)00042-8_BIB15","doi-asserted-by":"crossref","first-page":"2367","DOI":"10.1088\/0031-9155\/44\/10\/301","article-title":"Calculation of change in brain temperature due to exposure to a mobile phone","volume":"44","author":"Van Leeuwen","year":"1999","journal-title":"Phys. Med. Biol."},{"key":"10.1016\/S0010-4825(03)00042-8_BIB16","series-title":"Biokompatible Werkstoffe und Bauweisen","author":"Wintermantel","year":"1998"},{"key":"10.1016\/S0010-4825(03)00042-8_BIB17","series-title":"Repetitorium der Physik","author":"Kneub\u00fchl","year":"1990"},{"key":"10.1016\/S0010-4825(03)00042-8_BIB18","doi-asserted-by":"crossref","unstructured":"H. Leysieffer, J.W. Baumann , G. M\u00fcller, H.P. Zenner, Ein implantierbarer piezoelektrischer H\u00f6rger\u00e4tewandler f\u00fcr Innenohrschwerh\u00f6rige, Teil II: Klinisches Implantat, HNO 45 (1997) 801-815.","DOI":"10.1007\/s001060050159"}],"container-title":["Computers in Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0010482503000428?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0010482503000428?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2021,6,7]],"date-time":"2021-06-07T10:39:38Z","timestamp":1623062378000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0010482503000428"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,3]]},"references-count":18,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2004,3]]}},"alternative-id":["S0010482503000428"],"URL":"https:\/\/doi.org\/10.1016\/s0010-4825(03)00042-8","relation":{},"ISSN":["0010-4825"],"issn-type":[{"value":"0010-4825","type":"print"}],"subject":[],"published":{"date-parts":[[2004,3]]}}}