{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T07:54:59Z","timestamp":1769154899124,"version":"3.49.0"},"reference-count":22,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[1997,3,1]],"date-time":"1997-03-01T00:00:00Z","timestamp":857174400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Biomechanics"],"published-print":{"date-parts":[[1997,3]]},"DOI":"10.1016\/s0021-9290(97)81146-3","type":"journal-article","created":{"date-parts":[[2002,7,25]],"date-time":"2002-07-25T18:46:43Z","timestamp":1027622803000},"page":"285-289","source":"Crossref","is-referenced-by-count":98,"title":["Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imaging"],"prefix":"10.1016","volume":"30","author":[{"given":"F.","family":"Eckstein","sequence":"first","affiliation":[]},{"given":"C.","family":"Adam","sequence":"additional","affiliation":[]},{"given":"H.","family":"Sittek","sequence":"additional","affiliation":[]},{"given":"C.","family":"Becker","sequence":"additional","affiliation":[]},{"given":"S.","family":"Milz","sequence":"additional","affiliation":[]},{"given":"E.","family":"Schulte","sequence":"additional","affiliation":[]},{"given":"M.","family":"Reiser","sequence":"additional","affiliation":[]},{"given":"R.","family":"Putz","sequence":"additional","affiliation":[]}],"member":"78","reference":[{"key":"10.1016\/S0021-9290(97)81146-3_BIB1","first-page":"455","article-title":"Optimal imaging strategies for three-dimensional nuclear magnetic resonance microscopy","volume":"94","author":"Ahn","year":"1991","journal-title":"J. Magn. Resonance"},{"key":"10.1016\/S0021-9290(97)81146-3_BIB2","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1016\/0021-9290(91)90340-S","article-title":"Quantitation of articular surface topography and cartilage thickness in knee joints using stereophotogrammetry","volume":"24","author":"Ateshian","year":"1991","journal-title":"J. Biomechnics"},{"key":"10.1016\/S0021-9290(97)81146-3_BIB3","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1016\/0021-9290(91)90019-J","article-title":"Articular contact in a three-dimensional model of the knee","volume":"24","author":"Blankevoort","year":"1991","journal-title":"J. Biomechanics"},{"key":"10.1016\/S0021-9290(97)81146-3_BIB4","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1148\/radiology.178.2.1987624","article-title":"Knee hyaline cartilage evaluated with MR imaging: a cadaveric study involving multiple imaging sequences and intraarticular injection of gadolinium and saline solution","volume":"178","author":"Chandnani","year":"1991","journal-title":"Radiology"},{"key":"10.1016\/S0021-9290(97)81146-3_BIB5","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1259\/0007-1285-63-755-907","article-title":"High resolution, high field magnetic resonance imaging of joints: unexpected features in proton images of cartilage","volume":"63","author":"Cole","year":"1990","journal-title":"Brit. J. Radiol"},{"key":"10.1016\/S0021-9290(97)81146-3_BIB6","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1002\/mrm.1910360213","article-title":"Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondrocrassometry (3D MR-CCM)","volume":"36","author":"Eckstein","year":"1996","journal-title":"Magn. Reson. Med."},{"key":"10.1016\/S0021-9290(97)81146-3_BIB7","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1002\/mrm.1910350112","article-title":"Magnetic resonance chondro-crassometry (MR-CCM): a method for accurate determination of articular cartilage thickness?","volume":"35","author":"Eckstein","year":"1996","journal-title":"Magn. Reson. Med."},{"key":"10.1016\/S0021-9290(97)81146-3_BIB8","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1007\/BF01627667","article-title":"The morphology of articular cartilage assessed by magnetic resonance imaging (MRI)\u2014reproducibility and anatomical correlation","volume":"16","author":"Eckstein","year":"1994","journal-title":"Surg. Radiol. Anat."},{"key":"10.1016\/S0021-9290(97)81146-3_BIB9","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1016\/0268-0033(95)00013-1","article-title":"The potential of magnetic resonance imaging (MRI) for quantifying articular cartilage thickness\u2014a methodological study","volume":"10","author":"Eckstein","year":"1995","journal-title":"Clin. Biomech."},{"issue":"Suppl. 240","key":"10.1016\/S0021-9290(97)81146-3_BIB10","first-page":"19","article-title":"Magnetic resonance knee arthrography. Enhanced contrast by gadolinium complex in the rabbit and in humans","volume":"61","author":"Engel","year":"1990","journal-title":"Acta Orthop. Scand."},{"key":"10.1016\/S0021-9290(97)81146-3_BIB11","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.1016\/0021-9290(95)00059-Q","article-title":"The biomechanics of the human patella during passive knee flexion. ESB Research Award 1994","volume":"28","author":"Heegaard","year":"1995","journal-title":"J. Biomechanics"},{"key":"10.1016\/S0021-9290(97)81146-3_BIB12","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1002\/jor.1100010102","article-title":"Early changes in the material properties of rabbit articular cartilage after meniscectomy","volume":"1","author":"Hoch","year":"1983","journal-title":"J. orthop. Res."},{"key":"10.1016\/S0021-9290(97)81146-3_BIB13","doi-asserted-by":"crossref","first-page":"351","DOI":"10.2214\/ajr.159.2.1632354","article-title":"Width of the articular cartilage of the hip: quantification by using fat-suppression spin-echo MR imaging in cadavers","volume":"159","author":"Hodler","year":"1992","journal-title":"AJR"},{"key":"10.1016\/S0021-9290(97)81146-3_BIB14","doi-asserted-by":"crossref","first-page":"234","DOI":"10.3109\/02841859209173167","article-title":"Precision of hyaline cartilage thickness measurements","volume":"33","author":"Johnsson","year":"1992","journal-title":"Acta Radiol."},{"key":"10.1016\/S0021-9290(97)81146-3_BIB15","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/0021-9290(94)00060-H","article-title":"Comparison of optical, needle probe and ultrasonic techniques for the measurement of articular cartilage thickness","volume":"29","author":"Jurvelin","year":"1995","journal-title":"J. Biomechanics"},{"key":"10.1016\/S0021-9290(97)81146-3_BIB16","first-page":"197","article-title":"Knee joint articular cartilage shows general softening in patients with chondromalacia of the patella","volume":"20","author":"Kiviranta","year":"1995","journal-title":"Trans. Orthop. Res. Soc."},{"key":"10.1016\/S0021-9290(97)81146-3_BIB17","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1007\/BF00941240","article-title":"Thickness of patellofemoral articular cartilage as measured on MR imaging: sequence comparison of accuracy, reproducibility, and interobserver variation","volume":"24","author":"van Leersum","year":"1995","journal-title":"Skeletal Radiol."},{"key":"10.1016\/S0021-9290(97)81146-3_BIB18","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1002\/jor.1100130603","article-title":"Quantification of articular cartilage using magnetic resonance imaging and three-dimensional reconstruction","volume":"13","author":"Marshall","year":"1995","journal-title":"J. orthop. Res."},{"key":"10.1016\/S0021-9290(97)81146-3_BIB19","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/0021-9290(89)90041-9","article-title":"Optical verification of a technique for in situ ultrasonic measurement of articular cartilage thickness","volume":"22","author":"Modest","year":"1989","journal-title":"J. Biomechanics"},{"key":"10.1016\/S0021-9290(97)81146-3_BIB20","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1016\/0021-9290(89)90069-9","article-title":"Biphasic indentation of articular cartilage\u2014II. A numerical algorithm and an experimental study","volume":"22","author":"Mow","year":"1989","journal-title":"J. Biomechanics"},{"key":"10.1016\/S0021-9290(97)81146-3_BIB21","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1148\/radiology.192.2.8029420","article-title":"Quantification of articular cartilage in the knee with pulsed saturation transfer subtraction and fat-suppressed MR imaging: optimization and validation","volume":"192","author":"Peterfy","year":"1994","journal-title":"Radiology"},{"key":"10.1016\/S0021-9290(97)81146-3_BIB22","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/0021-9290(81)90070-1","article-title":"Improved techniques for measuring in vitro the geometry and pressure distribution in the human acetabulum\u2014I. Ultrasonic measurement of acetabular surfaces, sphericity and cartilage thickness","volume":"14","author":"Rushfeldt","year":"1981","journal-title":"J. Biomechanics"}],"container-title":["Journal of Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929097811463?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021929097811463?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,4,23]],"date-time":"2019-04-23T11:25:56Z","timestamp":1556018756000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021929097811463"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1997,3]]},"references-count":22,"journal-issue":{"issue":"3","published-print":{"date-parts":[[1997,3]]}},"alternative-id":["S0021929097811463"],"URL":"https:\/\/doi.org\/10.1016\/s0021-9290(97)81146-3","relation":{},"ISSN":["0021-9290"],"issn-type":[{"value":"0021-9290","type":"print"}],"subject":[],"published":{"date-parts":[[1997,3]]}}}