{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T09:51:50Z","timestamp":1768902710709,"version":"3.49.0"},"reference-count":30,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2003,5,1]],"date-time":"2003-05-01T00:00:00Z","timestamp":1051747200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Computer Methods and Programs in Biomedicine"],"published-print":{"date-parts":[[2003,5]]},"DOI":"10.1016\/s0169-2607(02)00030-5","type":"journal-article","created":{"date-parts":[[2003,4,30]],"date-time":"2003-04-30T21:26:08Z","timestamp":1051737968000},"page":"39-61","source":"Crossref","is-referenced-by-count":22,"title":["A program based on a \u2018selective\u2019 least-squares method for respiratory mechanics monitoring in ventilated patients"],"prefix":"10.1016","volume":"71","author":[{"given":"Andr\u00e9","family":"Eberhard","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pierre-Yves","family":"Carry","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean-Pierre","family":"Perdrix","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean-Marc","family":"Fargnoli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lo\u0131\u0308c","family":"Biot","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pierre F","family":"Baconnier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/S0169-2607(02)00030-5_BIB1","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1097\/00000542-199005000-00010","article-title":"Adverse respiratory events in anaesthesia: a closed claim analysis","volume":"72","author":"Caplan","year":"1990","journal-title":"Anaesthesiology"},{"key":"10.1016\/S0169-2607(02)00030-5_BIB2","doi-asserted-by":"crossref","first-page":"1083","DOI":"10.1007\/s001340050720","article-title":"Measurement of respiratory mechanics in paediatric intensive care: in vitro assessment of a pulmonary function device","volume":"24","author":"Neve","year":"1998","journal-title":"Intensive Care Med."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB3","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/0169-2607(95)01651-9","article-title":"A computer program for automatic measurement of respiratory mechanics in artificially ventilated patients","volume":"47","author":"Baconnier","year":"1995","journal-title":"Comput. Methods Programs Biomed."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB4","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1002\/ppul.1950100412","article-title":"Comparison of three methods for measuring respiratory mechanics in ventilated children","volume":"10","author":"Seear","year":"1991","journal-title":"Pediatr. Pulmonol."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB5","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1152\/jappl.1981.50.3.672","article-title":"A new method for computer-assisted determination of airways resistance","volume":"50","author":"Chowienczyk","year":"1981","journal-title":"J. Appl. Physiol."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB6","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1183\/09031936.94.07122241","article-title":"Fourier analysis versus multiple regression to analyze pressure-flow data during artificial ventilation","volume":"7","author":"Peslin","year":"1994","journal-title":"Eur. Respir. J."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB7","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1016\/0010-4809(74)90027-5","article-title":"Digital computer calculation of human pulmonary mechanics using a least square fit technique","volume":"7","author":"Uhl","year":"1974","journal-title":"Comput. Biomed. Res."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB8","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1152\/jappl.1992.73.2.479","article-title":"Intrinsic PEEP monitored in the ventilated ARDS patient with a mathematical method","volume":"73","author":"Eberhard","year":"1992","journal-title":"J. Appl. Physiol."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB9","doi-asserted-by":"crossref","first-page":"1235","DOI":"10.1378\/chest.102.4.1235","article-title":"Manoeuvre-free determination of compliance and resistance in ventilated ARDS patients","volume":"102","author":"Guttmann","year":"1992","journal-title":"Chest"},{"key":"10.1016\/S0169-2607(02)00030-5_BIB10","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1183\/09031936.93.05070871","article-title":"Respiratory mechanics studied by multiple linear regression in unsedated ventilated patients","volume":"5","author":"Peslin","year":"1992","journal-title":"Eur. Respir. J."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB11","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.1152\/jappl.1994.77.3.1185","article-title":"Influence of nonlinearities on estimates of respiratory mechanics using multilinear regression analysis","volume":"77","author":"Kano","year":"1994","journal-title":"J. Appl. Physiol."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB12","doi-asserted-by":"crossref","first-page":"1982","DOI":"10.1152\/jappl.1998.85.5.1982","article-title":"Measurement of pulmonary resistance and dynamic compliance with airway obstruction","volume":"85","author":"Officer","year":"1998","journal-title":"J. Appl. Physiol."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB13","doi-asserted-by":"crossref","first-page":"1159","DOI":"10.1152\/jappl.1991.71.3.1159","article-title":"Estimation of time-varying mechanical parameters by recursive least squares","volume":"71","author":"Lauzon","year":"1991","journal-title":"J. Appl. Physiol."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB14","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1109\/10.108133","article-title":"A nonstatistical approach to estimating confidence interval about model parameters: application to respiratory mechanics","volume":"39","author":"Bates","year":"1992","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB15","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1109\/10.376132","article-title":"Influence of flow pattern on the parameter estimates of a simple breathing mechanics model","volume":"42","author":"Avanzolini","year":"1995","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB16","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1007\/BF02738546","article-title":"A new approach for tracking respiratory mechanical parameters in real-time","volume":"25","author":"Avanzolini","year":"1997","journal-title":"Ann. Biomed. Eng."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB17","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1152\/jappl.1981.51.1.218","article-title":"Fluid dynamic factors in tracheal pressure measurement","volume":"51","author":"Chang","year":"1981","journal-title":"J. Appl. Physiol."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB18","first-page":"166","article-title":"Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction","volume":"126","author":"Pepe","year":"1982","journal-title":"Am. Rev. Respir. Dis."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB19","first-page":"672","article-title":"Measurement of static compliance of total respiratory system in patients with acute respiratory failure during mechanical ventilation","volume":"131","author":"Rossi","year":"1985","journal-title":"Am. Rev. Respir. Dis."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB20","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1002\/ppul.1950040306","article-title":"Evaluation of neonatal pulmonary mechanics and energetics: a two factor least mean square analysis","volume":"4","author":"Bhutani","year":"1988","journal-title":"Pediatr. Pulmonol."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB21","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/0169-2607(86)90064-7","article-title":"A cycle by cycle shape analysis of biological rhythms: application to respiratory rhythm","volume":"23","author":"Bachy","year":"1986","journal-title":"Comput. Methods Programs Biomed."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB22","series-title":"Analyse num\u00e9rique matricielle appliqu\u00e9e \u00e0 l'art de l'ing\u00e9nieur","first-page":"142","author":"Lascaux","year":"1993"},{"key":"10.1016\/S0169-2607(02)00030-5_BIB23","first-page":"81","article-title":"A computerized method for measuring respiratory mechanics during mechanical ventilation","volume":"22","author":"Lorino","year":"1986","journal-title":"Bull. Eur. Physiopathol. Respir."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB24","doi-asserted-by":"crossref","first-page":"1152","DOI":"10.1097\/00003246-199208000-00015","article-title":"Validation of respiratory mechanics software in microprocessor-controlled ventilators","volume":"20","author":"Korst","year":"1992","journal-title":"Crit. Care Med."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB25","doi-asserted-by":"crossref","first-page":"922","DOI":"10.1152\/jappl.1993.74.2.922","article-title":"Comparison of mathematical and mechanical models of pressure-controlled ventilation","volume":"74","author":"Burke","year":"1993","journal-title":"J. Appl. Physiol."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB26","first-page":"423","article-title":"Automated measurement of respiratory mechanics in anaesthetised ventilated patients","volume":"23","author":"Benhamou","year":"1987","journal-title":"Bull. Eur. Physiopathol. Respir."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB27","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1183\/09031936.98.12030526","article-title":"Measurement of overinflation by multiple regression analysis in patients with acute lung injury","volume":"12","author":"Bernsten","year":"1998","journal-title":"Eur. Respir. J."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB28","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1007\/s001340051016","article-title":"Volume-dependent compliance in ARDS: proposal of a new diagnostic concept","volume":"25","author":"Mols","year":"1999","journal-title":"Intensive Care Med."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB29","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1152\/jappl.1999.86.1.418","article-title":"Estimating respiratory mechanics in the presence of flow limitation","volume":"86","author":"Bijaoui","year":"1999","journal-title":"J. Appl. Physiol."},{"key":"10.1016\/S0169-2607(02)00030-5_BIB30","doi-asserted-by":"crossref","first-page":"1393","DOI":"10.1213\/00000539-199812000-00035","article-title":"Respiratory mechanics during laparoscopic cholecystectomy: the effects of abdominal wall lift","volume":"87","author":"Carry","year":"1998","journal-title":"Anesth. Analg."}],"container-title":["Computer Methods and Programs in Biomedicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0169260702000305?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0169260702000305?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2023,4,17]],"date-time":"2023-04-17T21:06:43Z","timestamp":1681765603000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0169260702000305"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,5]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2003,5]]}},"alternative-id":["S0169260702000305"],"URL":"https:\/\/doi.org\/10.1016\/s0169-2607(02)00030-5","relation":{},"ISSN":["0169-2607"],"issn-type":[{"value":"0169-2607","type":"print"}],"subject":[],"published":{"date-parts":[[2003,5]]}}}