{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,6]],"date-time":"2025-11-06T05:53:03Z","timestamp":1762408383392,"version":"3.44.0"},"reference-count":25,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2005,6,1]],"date-time":"2005-06-01T00:00:00Z","timestamp":1117584000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2005,6,1]],"date-time":"2005-06-01T00:00:00Z","timestamp":1117584000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Analytical Biochemistry"],"published-print":{"date-parts":[[2005,6]]},"DOI":"10.1016\/j.ab.2005.03.014","type":"journal-article","created":{"date-parts":[[2005,3,29]],"date-time":"2005-03-29T07:31:28Z","timestamp":1112081488000},"page":"299-307","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":45,"title":["Spectrofluorimetric determination of heparin using a tetracycline\u2013europium probe"],"prefix":"10.1016","volume":"341","author":[{"given":"Xiaojing","family":"Zhu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaolei","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chongqiu","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ab.2005.03.014_bib1","doi-asserted-by":"crossref","first-page":"4614","DOI":"10.1021\/ac990387s","article-title":"Renewable pH cross-sensitive potentiometric heparin sensors with incorporated electrically charged H+ ionophores","volume":"71","author":"Mathison","year":"1999","journal-title":"Anal. Chem."},{"year":"1999","series-title":"Handbook of chemical products","author":"Wang","key":"10.1016\/j.ab.2005.03.014_bib2"},{"key":"10.1016\/j.ab.2005.03.014_bib3","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1016\/S0039-9140(98)00330-0","article-title":"Investigation on the binding site in heparin by spectrophotometry","volume":"48","author":"Jiao","year":"1999","journal-title":"Talanta"},{"year":"1985","series-title":"Pharmacopoeia of the people\u2019s republic of china","author":"Qian","key":"10.1016\/j.ab.2005.03.014_bib4"},{"key":"10.1016\/j.ab.2005.03.014_bib5","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/S0003-2670(99)00472-9","article-title":"Determination of heparin using flow injection analysis with spectrophotometric detection","volume":"401","author":"N\u011bmcov\u00e1","year":"1999","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.ab.2005.03.014_bib6","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/S0003-2670(00)00740-6","article-title":"Development of an ion-channel sensor for heparin detection","volume":"411","author":"Gadzekpo","year":"2000","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.ab.2005.03.014_bib7","doi-asserted-by":"crossref","first-page":"3907","DOI":"10.1021\/ac001454h","article-title":"Resonance Rayleigh scattering study of the interaction of heparin with some basic diphenyl naphthylmethane dyes","volume":"73","author":"Liu","year":"2001","journal-title":"Anal. Chem."},{"key":"10.1016\/j.ab.2005.03.014_bib8","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/S0003-2670(01)01365-4","article-title":"Resonance Rayleigh scattering spectra for studying the interaction of heparin with some basic phenothiazine dyes and their analytical applications","volume":"449","author":"Luo","year":"2001","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.ab.2005.03.014_bib9","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1016\/S0039-9140(98)00040-X","article-title":"Determination of plasma heparin by micellar electrokinetic capillary chromatography","volume":"46","author":"Zhou","year":"1998","journal-title":"Talanta"},{"key":"10.1016\/j.ab.2005.03.014_bib10","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/S0378-4347(97)00478-7","article-title":"Sensitive high-performance liquid chromatographic method with fluorometric detection for the determination of heparin and heparan sulfate in biological samples: application to human urinary heparan sulfate","volume":"704","author":"Toyoda","year":"1997","journal-title":"J. Chromatogr. B"},{"key":"10.1016\/j.ab.2005.03.014_bib11","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.1016\/S0956-5663(98)00094-3","article-title":"Surface plasmon resonance sensor for heparin measurements in blood plasma","volume":"13","author":"Gaus","year":"1998","journal-title":"Biosens. Bioelectron."},{"key":"10.1016\/j.ab.2005.03.014_bib12","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1021\/ac000756g","article-title":"Rotating electrode potentiometry: Lowering the detection limits of nonequilibrium polyion-sensitive membrane electrodes","volume":"73","author":"Ye","year":"2001","journal-title":"Anal. Chem."},{"key":"10.1016\/j.ab.2005.03.014_bib13","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/S0003-2670(00)01346-5","article-title":"Determination of heparin levels in blood with activated partial thromboplastin time by a piezoelectric quartz crystal sensor","volume":"432","author":"Cheng","year":"2001","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.ab.2005.03.014_bib14","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1093\/clinchem\/44.3.606","article-title":"Improved protamine-sensitive membrane electrode for monitoring heparin concentrations in whole blood via protamine titration","volume":"44","author":"Ramamurthy","year":"1998","journal-title":"Clin. Chem."},{"key":"10.1016\/j.ab.2005.03.014_bib15","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1093\/clinchem\/47.5.858","article-title":"Evaluation of the TAS analyzer and the low-range heparin management test in patients undergoing extracorporeal membrane oxygenation","volume":"47","author":"Ambrose","year":"2001","journal-title":"Clin. Chem."},{"key":"10.1016\/j.ab.2005.03.014_bib16","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.aca.2004.01.043","article-title":"Lysozyme enhanced europium\u2013metacycline complex fluorescence: a new spectrofluorimetric method for the determination of lysozyme","volume":"511","author":"Jiang","year":"2004","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.ab.2005.03.014_bib17","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/j.aca.2003.11.013","article-title":"Spectrofluorimetric determination of human serum albumin using a doxycycline\u2013europium probe","volume":"506","author":"Jiang","year":"2004","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.ab.2005.03.014_bib18","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/S0003-2697(03)00356-7","article-title":"Determination of the activity of catalase using a europium(III)\u2013tetracycline-derived fluorescent substrate","volume":"320","author":"Wu","year":"2003","journal-title":"Anal. Biochem."},{"key":"10.1016\/j.ab.2005.03.014_bib19","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1007\/s00604-003-0087-0","article-title":"Detection of hydrogen peroxide in river water via a microplate luminescence assay with time-resolved (\u201cgated\u201d) detection","volume":"143","author":"Lei","year":"2003","journal-title":"Microchim. Acta"},{"key":"10.1016\/j.ab.2005.03.014_bib20","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/S0022-2313(01)00234-4","article-title":"Study of the interaction between nucleic acid and oxytetracycline\u2013Eu3+ and its analytical application","volume":"96","author":"Liu","year":"2002","journal-title":"J. Luminesc."},{"key":"10.1016\/j.ab.2005.03.014_bib21","doi-asserted-by":"crossref","first-page":"1869","DOI":"10.1021\/ac0013305","article-title":"Synthesis of a terbium fluorescent chelate and its application to time-resolved fluoroimmunoassay","volume":"73","author":"Yuan","year":"2001","journal-title":"Anal. Chem."},{"key":"10.1016\/j.ab.2005.03.014_bib22","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/0003-2697(67)90297-7","article-title":"A graphic method for the determination and presentation of binding parameters in a complex system","volume":"20","author":"Rosenthal","year":"1967","journal-title":"Anal. Biochem."},{"key":"10.1016\/j.ab.2005.03.014_bib23","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1039\/a902253h","article-title":"Determination of protein based on absorbance decrease of molybdenum(VI) complex with 2,6,7-trihydroxy-9-(4-chlorophenyl)-3H-xanthen-3-one","volume":"124","author":"Guo","year":"1999","journal-title":"Analyst"},{"key":"10.1016\/j.ab.2005.03.014_bib24","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1016\/S1386-1425(99)00286-3","article-title":"Application of aluminium(III) complex with salicylidene-o-aminophenol to the fluorometric determination of nucleic acids","volume":"56","author":"Hao","year":"2000","journal-title":"Spectrochim. Acta"},{"key":"10.1016\/j.ab.2005.03.014_bib25","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1021\/cr00051a004","article-title":"Terbium(III) and europium(III) ions as luminescent probes and stains for biomolecular systems","volume":"82","author":"Richardson","year":"1982","journal-title":"Chem. Rev."}],"container-title":["Analytical Biochemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003269705001995?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003269705001995?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T20:39:48Z","timestamp":1757709588000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0003269705001995"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,6]]},"references-count":25,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2005,6]]}},"alternative-id":["S0003269705001995"],"URL":"https:\/\/doi.org\/10.1016\/j.ab.2005.03.014","relation":{},"ISSN":["0003-2697"],"issn-type":[{"type":"print","value":"0003-2697"}],"subject":[],"published":{"date-parts":[[2005,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Spectrofluorimetric determination of heparin using a tetracycline\u2013europium probe","name":"articletitle","label":"Article Title"},{"value":"Analytical Biochemistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ab.2005.03.014","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2005 Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}