{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T21:11:33Z","timestamp":1792789893325,"version":"4.5.0"},"reference-count":28,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2020,4,1]],"date-time":"2020-04-01T00:00:00Z","timestamp":1585699200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,4,1]],"date-time":"2020-04-01T00:00:00Z","timestamp":1585699200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,1,9]],"date-time":"2021-01-09T00:00:00Z","timestamp":1610150400000},"content-version":"vor","delay-in-days":283,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100005366","name":"Universitetet i Oslo","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005366","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Analytica Chimica Acta"],"published-print":{"date-parts":[[2020,4]]},"DOI":"10.1016\/j.aca.2020.01.058","type":"journal-article","created":{"date-parts":[[2020,1,28]],"date-time":"2020-01-28T08:32:34Z","timestamp":1580200354000},"page":"1-9","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":14,"special_numbering":"C","title":["Towards exhaustive electromembrane extraction under stagnant conditions"],"prefix":"10.1016","volume":"1104","author":[{"given":"Magnus Saed","family":"Restan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6060-8219","authenticated-orcid":false,"given":"\u00d8ystein","family":"Skj\u00e6rv\u00f8","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u00d8rjan G.","family":"Martinsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1666-8043","authenticated-orcid":false,"given":"Stig","family":"Pedersen-Bjergaard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.aca.2020.01.058_bib1","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/j.chroma.2006.01.025","article-title":"Electrokinetic migration across artificial liquid membranes: new concept for rapid sample preparation of biological fluids","volume":"1109","author":"Pedersen-Bjergaard","year":"2006","journal-title":"J.\u00a0Chromatogr. A"},{"key":"10.1016\/j.aca.2020.01.058_bib2","doi-asserted-by":"crossref","DOI":"10.1515\/revac-2016-0008","article-title":"Organic solvents in electromembrane extraction: recent insights","volume":"35","author":"Huang","year":"2016","journal-title":"Rev. Anal. Chem."},{"key":"10.1016\/j.aca.2020.01.058_bib3","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.memsci.2016.11.049","article-title":"Electromembrane extraction with alkylated phosphites and phosphates as supported liquid membranes","volume":"526","author":"Huang","year":"2017","journal-title":"J.\u00a0Membr. Sci."},{"key":"10.1016\/j.aca.2020.01.058_bib4","doi-asserted-by":"crossref","first-page":"8267","DOI":"10.1021\/acs.analchem.9b00946","article-title":"Liquid-phase microextraction or electromembrane extraction?","volume":"91","author":"Wan","year":"2019","journal-title":"Anal. Chem."},{"key":"10.1016\/j.aca.2020.01.058_bib5","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.aca.2016.07.048","article-title":"Simultaneous extraction of acidic and basic drugs via on-chip electromembrane extraction","volume":"937","author":"Asl","year":"2016","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2020.01.058_bib6","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.talanta.2011.08.026","article-title":"Electromembrane extraction and HPLC analysis of haloacetic acids and aromatic acetic acids in wastewater","volume":"86","author":"Alhooshani","year":"2011","journal-title":"Talanta"},{"key":"10.1016\/j.aca.2020.01.058_bib7","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/j.chroma.2008.04.041","article-title":"Electromembrane extraction of peptides","volume":"1194","author":"Balchen","year":"2008","journal-title":"J.\u00a0Chromatogr. A"},{"key":"10.1016\/j.aca.2020.01.058_bib8","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1002\/elps.201000462","article-title":"Electromembrane extraction of heavy metal cations followed by capillary electrophoresis with capacitively coupled contactless conductivity detection","volume":"32","author":"Kuban","year":"2011","journal-title":"Electrophoresis"},{"key":"10.1016\/j.aca.2020.01.058_bib9","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.chroma.2008.10.041","article-title":"Extraction of lead ions by electromembrane isolation","volume":"1213","author":"Basheer","year":"2008","journal-title":"J.\u00a0Chromatogr. A"},{"key":"10.1016\/j.aca.2020.01.058_bib10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jchromb.2016.01.014","article-title":"Microwave-assisted digestion followed by parallel electromembrane extraction for trace level perchlorate detection in biological samples","volume":"1012","author":"Nsubuga","year":"2016","journal-title":"J.\u00a0Chromatogr. B"},{"key":"10.1016\/j.aca.2020.01.058_bib11","first-page":"s447","article-title":"Determination of chlorophenols in environmental samples using electromembrane extraction and capillary electrophoresis","volume":"107","author":"\u0160lampov\u00e1","year":"2013","journal-title":"Chem. Listy"},{"key":"10.1016\/j.aca.2020.01.058_bib12","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.talanta.2014.02.066","article-title":"Extraction of pyridine derivatives from human urine using electromembrane extraction coupled to dispersive liquid\u2013liquid microextraction followed by gas chromatography determination","volume":"126","author":"Arjomandi-Behzad","year":"2014","journal-title":"Talanta"},{"key":"10.1016\/j.aca.2020.01.058_bib13","doi-asserted-by":"crossref","first-page":"6951","DOI":"10.1021\/acs.analchem.5b01610","article-title":"Combination of electromembrane extraction and liquid-phase microextraction in a single step: simultaneous group separation of acidic and basic drugs","volume":"87","author":"Huang","year":"2015","journal-title":"Anal. Chem."},{"key":"10.1016\/j.aca.2020.01.058_bib14","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1007\/s00216-008-2344-x","article-title":"Electromembrane extraction of basic drugs from untreated human plasma and whole blood under physiological pH conditions","volume":"393","author":"Gjelstad","year":"2009","journal-title":"Anal. Bioanal. Chem."},{"key":"10.1016\/j.aca.2020.01.058_bib15","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1021\/ac1027148","article-title":"On-chip electro membrane extraction with online ultraviolet and mass spectrometric detection","volume":"83","author":"Petersen","year":"2011","journal-title":"Anal. Chem."},{"key":"10.1016\/j.aca.2020.01.058_bib16","doi-asserted-by":"crossref","first-page":"3321","DOI":"10.1039\/c2an35264h","article-title":"On-chip electromembrane extraction for monitoring drug metabolism in real time by electrospray ionization mass spectrometry","volume":"137","author":"Petersen","year":"2012","journal-title":"Analyst"},{"key":"10.1016\/j.aca.2020.01.058_bib17","doi-asserted-by":"crossref","first-page":"110221","DOI":"10.1039\/C6RA18798F","article-title":"Effect of type of stirring on hollow fiber liquid phase microextraction and electromembrane extraction of basic drugs: speed up extraction time and enhancement of extraction efficiency","volume":"6","author":"Nojavan","year":"2016","journal-title":"RSC Adv."},{"key":"10.1016\/j.aca.2020.01.058_bib18","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.1016\/j.chroma.2008.12.079","article-title":"Drop-to-drop microextraction across a supported liquid membrane by an electrical field under stagnant conditions","volume":"1216","author":"Petersen","year":"2009","journal-title":"J.\u00a0Chromatogr. A"},{"key":"10.1016\/j.aca.2020.01.058_bib19","doi-asserted-by":"crossref","first-page":"5050","DOI":"10.1016\/j.chroma.2010.06.018","article-title":"Kinetic electro membrane extraction under stagnant conditions--fast isolation of drugs from untreated human plasma","volume":"1217","author":"Eibak","year":"2010","journal-title":"J.\u00a0Chromatogr. A"},{"key":"10.1016\/j.aca.2020.01.058_bib20","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.aca.2017.11.081","article-title":"Semi-automated set-up for exhaustive micro-electromembrane extractions of basic drugs from biological fluids","volume":"1005","author":"Dvo\u0159\u00e1k","year":"2018","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2020.01.058_bib21","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.aca.2017.06.049","article-title":"Comprehensive study of buffer systems and local pH effects in electromembrane extraction","volume":"984","author":"Restan","year":"2017","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2020.01.058_bib22","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.chroma.2007.08.057","article-title":"Simulation of flux during electro-membrane extraction based on the Nernst\u2013Planck equation","volume":"1174","author":"Gjelstad","year":"2007","journal-title":"J.\u00a0Chromatogr. A"},{"key":"10.1016\/j.aca.2020.01.058_bib23","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.chroma.2013.07.105","article-title":"Electromembrane extraction from aqueous samples containing polar organic solvents","volume":"1308","author":"Seip","year":"2013","journal-title":"J.\u00a0Chromatogr. A"},{"key":"10.1016\/j.aca.2020.01.058_bib24","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.chroma.2007.08.057","article-title":"Simulation of flux during electro-membrane extraction based on the Nernst\u2013Planck equation","volume":"1174","author":"Gjelstad","year":"2007","journal-title":"J.\u00a0Chromatogr. A"},{"key":"10.1016\/j.aca.2020.01.058_bib25","doi-asserted-by":"crossref","DOI":"10.7243\/2052-6962-2-5","article-title":"Plasma viscosity and whole blood viscosity as diagnostic tools of blood abnormalities by using simple syringe method","volume":"2","author":"Elblbesy","year":"2014","journal-title":"Med. Instrum."},{"key":"10.1016\/j.aca.2020.01.058_bib26","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1007\/s00216-008-2344-x","article-title":"Electromembrane extraction of basic drugs from untreated human plasma and whole blood under physiological pH conditions","volume":"393","author":"Gjelstad","year":"2009","journal-title":"Anal. Bioanal. Chem."},{"key":"10.1016\/j.aca.2020.01.058_bib27","article-title":"A\u00a0sensitive Lc-Ms\/Ms assay for the quantification of methadone and its metabolites in dried blood spots: comparison with plasma","author":"Davari","year":"2019","journal-title":"Ther. Drug Monit."},{"key":"10.1016\/j.aca.2020.01.058_bib28","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.drugalcdep.2019.03.013","article-title":"The optimization of methadone dosing whilst treating with rifampicin: a pharmacokinetic modeling study","volume":"200","author":"Badhan","year":"2019","journal-title":"Drug Alcohol Depend."}],"container-title":["Analytica Chimica Acta"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003267020301112?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003267020301112?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T19:18:29Z","timestamp":1757704709000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0003267020301112"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4]]},"references-count":28,"alternative-id":["S0003267020301112"],"URL":"https:\/\/doi.org\/10.1016\/j.aca.2020.01.058","relation":{},"ISSN":["0003-2670"],"issn-type":[{"value":"0003-2670","type":"print"}],"subject":[],"published":{"date-parts":[[2020,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Towards exhaustive electromembrane extraction under stagnant conditions","name":"articletitle","label":"Article Title"},{"value":"Analytica Chimica Acta","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.aca.2020.01.058","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 The Authors. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}]}}