{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T09:48:22Z","timestamp":1792230502203,"version":"4.4.0"},"reference-count":26,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2020,11,1]],"date-time":"2020-11-01T00:00:00Z","timestamp":1604188800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,11,1]],"date-time":"2020-11-01T00:00:00Z","timestamp":1604188800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100001824","name":"Grantov\u00e1 Agentura \u010cesk\u00e9 Republiky","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001824","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Analytica Chimica Acta"],"published-print":{"date-parts":[[2020,11]]},"DOI":"10.1016\/j.aca.2020.08.061","type":"journal-article","created":{"date-parts":[[2020,9,6]],"date-time":"2020-09-06T01:48:06Z","timestamp":1599356886000},"page":"74-84","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":35,"special_numbering":"C","title":["Determination of one year stability of lipid plasma profile and comparison of blood collection tubes using UHPSFC\/MS and HILIC-UHPLC\/MS"],"prefix":"10.1016","volume":"1137","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2664-3912","authenticated-orcid":false,"given":"Denise","family":"Wolrab","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michaela","family":"Chocholou\u0161kov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Jir\u00e1sko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ond\u0159ej","family":"Peterka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vladim\u00edra","family":"Mu\u017e\u00e1kov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hana","family":"\u0160tudentov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bohuslav","family":"Melichar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3978-1249","authenticated-orcid":false,"given":"Michal","family":"Hol\u010dapek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"12","key":"10.1016\/j.aca.2020.08.061_bib1","first-page":"2015","article-title":"Joint EFLM-COLABIOCLI Recommendation for venous blood sampling","volume":"56","author":"Simundic","year":"2018"},{"issue":"7","key":"10.1016\/j.aca.2020.08.061_bib2","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1080\/10408363.2018.1499708","article-title":"Sample management for clinical biochemistry assays: are serum and plasma interchangeable specimens?","volume":"55","author":"Lima-Oliveira","year":"2018","journal-title":"Crit. Rev. Clin. Lab Sci."},{"key":"10.1016\/j.aca.2020.08.061_bib3","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.aca.2018.03.009","article-title":"Serum or plasma, what is the difference? Investigations to facilitate the sample material selection decision making process for metabolomics studies and beyond","volume":"1037","author":"Liu","year":"2018","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2020.08.061_bib4","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1016\/j.talanta.2015.12.079","article-title":"Influence of the collection tube on metabolomic changes in serum and plasma","volume":"150","author":"L\u00f3pez-Basc\u00f3n","year":"2016","journal-title":"Talanta"},{"issue":"12","key":"10.1016\/j.aca.2020.08.061_bib5","doi-asserted-by":"crossref","first-page":"2035","DOI":"10.3390\/ijms17122035","article-title":"A\u00a0systematic evaluation of blood serum and plasma pre-analytics for metabolomics cohort studies","volume":"17","author":"Jobard","year":"2016","journal-title":"Int. J. Mol. Sci."},{"issue":"7","key":"10.1016\/j.aca.2020.08.061_bib6","doi-asserted-by":"crossref","first-page":"2547","DOI":"10.1021\/acs.jproteome.7b00106","article-title":"Plasma and serum metabolite association networks: Comparability within and between studies using NMR and MS profiling","volume":"16","author":"Suarez-Diez","year":"2017","journal-title":"J.\u00a0Proteome Res."},{"issue":"7","key":"10.1016\/j.aca.2020.08.061_bib7","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0021230","article-title":"Differences between human plasma and serum metabolite profiles","volume":"6","author":"Yu","year":"2011","journal-title":"PloS One"},{"issue":"4","key":"10.1016\/j.aca.2020.08.061_bib8","doi-asserted-by":"crossref","first-page":"1426","DOI":"10.1021\/acs.jproteome.7b00788","article-title":"Systematic evaluation of the use of human plasma and serum for mass-spectrometry-based shotgun proteomics","volume":"17","author":"Lan","year":"2018","journal-title":"J.\u00a0Proteome Res."},{"issue":"3","key":"10.1016\/j.aca.2020.08.061_bib9","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.1021\/ac102806p","article-title":"Characterization of differences between blood sample matrices in untargeted metabolomics","volume":"83","author":"Denery","year":"2011","journal-title":"Anal. Chem."},{"issue":"1","key":"10.1016\/j.aca.2020.08.061_bib10","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1021\/pr800545q","article-title":"Standard operating procedures for serum and plasma collection: Early detection research network consensus statement standard operating procedure integration working group","volume":"8","author":"Tuck","year":"2009","journal-title":"J.\u00a0Proteome Res."},{"issue":"17","key":"10.1016\/j.aca.2020.08.061_bib11","doi-asserted-by":"crossref","first-page":"6689","DOI":"10.1021\/ac2012224","article-title":"Is serum or plasma more appropriate for intersubject comparisons in metabolomic studies? An assessment in patients with small-cell lung cancer","volume":"83","author":"Wedge","year":"2011","journal-title":"Anal. Chem."},{"issue":"13","key":"10.1016\/j.aca.2020.08.061_bib12","doi-asserted-by":"crossref","first-page":"4307","DOI":"10.1021\/ac051972y","article-title":"Impact of analytical bias in metabonomic studies of human blood serum and plasma","volume":"78","author":"Teahan","year":"2006","journal-title":"Anal. Chem."},{"issue":"34","key":"10.1016\/j.aca.2020.08.061_bib13","doi-asserted-by":"crossref","first-page":"5638","DOI":"10.1200\/JCO.2007.15.1712","article-title":"Recommendations for collection and handling of specimens from group breast cancer clinical trials","volume":"26","author":"Leyland-Jones","year":"2008","journal-title":"J.\u00a0Clin. Oncol."},{"issue":"17","key":"10.1016\/j.aca.2020.08.061_bib14","doi-asserted-by":"crossref","first-page":"4879","DOI":"10.1007\/s00216-015-8565-x","article-title":"Effects of pre-analytical processes on blood samples used in metabolomics studies","volume":"407","author":"Yin","year":"2015","journal-title":"Anal. Bioanal. Chem."},{"issue":"7","key":"10.1016\/j.aca.2020.08.061_bib15","doi-asserted-by":"crossref","first-page":"594","DOI":"10.1038\/nrd1776","article-title":"The emerging field of lipidomics","volume":"4","author":"Wenk","year":"2005","journal-title":"Nat. Rev. Drug Discov."},{"key":"10.1016\/j.aca.2020.08.061_bib16","doi-asserted-by":"crossref","DOI":"10.1016\/j.trac.2019.04.012","article-title":"Oncolipidomics: mass spectrometric quantitation of lipids in cancer research","volume":"120","author":"Wolrab","year":"2019","journal-title":"Trac. Trends Anal. Chem."},{"issue":"7","key":"10.1016\/j.aca.2020.08.061_bib17","doi-asserted-by":"crossref","first-page":"4249","DOI":"10.1021\/acs.analchem.7b05395","article-title":"Lipidomic analysis","volume":"90","author":"Hol\u010dapek","year":"2018","journal-title":"Anal. Chem."},{"issue":"22","key":"10.1016\/j.aca.2020.08.061_bib18","doi-asserted-by":"crossref","first-page":"12425","DOI":"10.1021\/acs.analchem.7b03523","article-title":"Hydrophilic interaction liquid chromatography\u2013mass spectrometry characterization of gangliosides in biological samples","volume":"89","author":"H\u00e1jek","year":"2017","journal-title":"Anal. Chem."},{"issue":"3","key":"10.1016\/j.aca.2020.08.061_bib19","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1002\/rcm.7791","article-title":"Correlation of lipidomic composition of cell lines and tissues of breast cancer patients using hydrophilic interaction liquid chromatography\/electrospray ionization mass spectrometry and multivariate data analysis","volume":"31","author":"C\u00edfkov\u00e1","year":"2017","journal-title":"Rapid Commun. Mass Spectrom."},{"issue":"10","key":"10.1016\/j.aca.2020.08.061_bib20","doi-asserted-by":"crossref","first-page":"2375","DOI":"10.1007\/s00216-020-02473-3","article-title":"Validation of lipidomic analysis of human plasma and serum by supercritical fluid chromatography\u2013mass spectrometry and hydrophilic interaction liquid chromatography\u2013mass spectrometry","volume":"412","author":"Wolrab","year":"2020","journal-title":"Anal. Bioanal. Chem."},{"issue":"14","key":"10.1016\/j.aca.2020.08.061_bib21","doi-asserted-by":"crossref","first-page":"7187","DOI":"10.1021\/acs.analchem.5b01054","article-title":"High-throughput and comprehensive lipidomic analysis using ultrahigh-performance supercritical fluid chromatography\u2013mass spectrometry","volume":"87","author":"L\u00edsa","year":"2015","journal-title":"Anal. Chem."},{"issue":"50","key":"10.1016\/j.aca.2020.08.061_bib23","doi-asserted-by":"crossref","first-page":"48737","DOI":"10.1074\/jbc.M206812200","article-title":"Serum lysophosphatidic acid is produced through diverse phospholipase pathways","volume":"277","author":"Aoki","year":"2002","journal-title":"J.\u00a0Biol. Chem."},{"issue":"1","key":"10.1016\/j.aca.2020.08.061_bib24","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1038\/s41467-017-00413-x","article-title":"Establishing multiple omics baselines for three Southeast Asian populations in the Singapore integrative omics study","volume":"8","author":"Saw","year":"2017","journal-title":"Nat. Commun."},{"issue":"12","key":"10.1016\/j.aca.2020.08.061_bib25","doi-asserted-by":"crossref","first-page":"2275","DOI":"10.1194\/jlr.M079012","article-title":"Harmonizing lipidomics: NIST interlaboratory comparison exercise for lipidomics using SRM 1950\u2013Metabolites in Frozen Human Plasma","volume":"58","author":"Bowden","year":"2017","journal-title":"J.\u00a0Lipid Res."},{"issue":"8","key":"10.1016\/j.aca.2020.08.061_bib26","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1038\/s42255-019-0094-z","article-title":"Lipidomics needs more standardization","volume":"1","author":"Liebisch","year":"2019","journal-title":"Nature Metabolism"},{"issue":"1","key":"10.1016\/j.aca.2020.08.061_bib27","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1194\/jlr.D119000393","article-title":"Shared reference materials harmonize lipidomics across MS-based detection platforms and laboratories","volume":"61","author":"Triebl","year":"2020","journal-title":"J.\u00a0Lipid Res."}],"container-title":["Analytica Chimica Acta"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003267020309089?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003267020309089?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T19:25:21Z","timestamp":1757705121000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0003267020309089"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,11]]},"references-count":26,"alternative-id":["S0003267020309089"],"URL":"https:\/\/doi.org\/10.1016\/j.aca.2020.08.061","relation":{},"ISSN":["0003-2670"],"issn-type":[{"value":"0003-2670","type":"print"}],"subject":[],"published":{"date-parts":[[2020,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Determination of one year stability of lipid plasma profile and comparison of blood collection tubes using UHPSFC\/MS and HILIC-UHPLC\/MS","name":"articletitle","label":"Article Title"},{"value":"Analytica Chimica Acta","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.aca.2020.08.061","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}