{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T19:50:19Z","timestamp":1785354619541,"version":"3.55.0"},"reference-count":49,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/501100007059","name":"Palacky University Olomouc","doi-asserted-by":"publisher","award":["IGA_PrF_2023_020"],"award-info":[{"award-number":["IGA_PrF_2023_020"]}],"id":[{"id":"10.13039\/501100007059","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100007059","name":"Palacky University Olomouc","doi-asserted-by":"publisher","award":["IGA_PrF_2023_031"],"award-info":[{"award-number":["IGA_PrF_2023_031"]}],"id":[{"id":"10.13039\/501100007059","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100007601","name":"Horizon 2020","doi-asserted-by":"publisher","award":["862858"],"award-info":[{"award-number":["862858"]}],"id":[{"id":"10.13039\/501100007601","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Analytica Chimica Acta"],"published-print":{"date-parts":[[2024,1]]},"DOI":"10.1016\/j.aca.2023.342010","type":"journal-article","created":{"date-parts":[[2023,11,15]],"date-time":"2023-11-15T02:29:39Z","timestamp":1700015379000},"page":"342010","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"special_numbering":"C","title":["Rapid profiling of cytokinins using supercritical fluid chromatography coupled with tandem mass spectrometry"],"prefix":"10.1016","volume":"1285","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5320-7599","authenticated-orcid":false,"given":"Ivan","family":"Pet\u0159\u00edk","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1314-2249","authenticated-orcid":false,"given":"Ale\u0161","family":"P\u011bn\u010d\u00edk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jakub","family":"St\u00fdskala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lenka","family":"Tranov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Petra","family":"Amakorov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miroslav","family":"Strnad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3452-0154","authenticated-orcid":false,"given":"Ond\u0159ej","family":"Nov\u00e1k","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.aca.2023.342010_bib1","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1111\/j.1399-3054.1997.tb01052.x","article-title":"The aromatic cytokinins","volume":"101","author":"Strnad","year":"1997","journal-title":"Physiol. Plantarum"},{"key":"10.1016\/j.aca.2023.342010_bib2","doi-asserted-by":"crossref","first-page":"1392","DOI":"10.1021\/ja01610a105","article-title":"Kinetin, a cell division factor from deoxyribonucleic acid","volume":"77","author":"Miller","year":"1955","journal-title":"J. Am. Chem. Soc."},{"key":"10.1016\/j.aca.2023.342010_bib3","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1023\/A:1006192619432","article-title":"Biological activity of cytokinins derived from Ortho- and Meta-Hydroxybenzyladenine","volume":"26","author":"Holub","year":"1998","journal-title":"Plant Growth Regul."},{"key":"10.1016\/j.aca.2023.342010_bib4","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/S0981-9428(02)01362-1","article-title":"Aromatic cytokinins in micropropagated potato plants","volume":"40","author":"Baroja-Fernandez","year":"2002","journal-title":"Plant Physiol. Biochem."},{"key":"10.1016\/j.aca.2023.342010_bib5","doi-asserted-by":"crossref","first-page":"1851","DOI":"10.1093\/jxb\/eru522","article-title":"Plant membrane assays with cytokinin receptors underpin the unique role of free cytokinin bases as biologically active ligands","volume":"66","author":"Lomin","year":"2015","journal-title":"J. Exp. Bot."},{"key":"10.1016\/j.aca.2023.342010_bib6","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1016\/j.pbi.2009.07.002","article-title":"Cytokinin action in plant development","volume":"12","author":"Werner","year":"2009","journal-title":"Curr. Opin. Plant Biol."},{"key":"10.1016\/j.aca.2023.342010_bib7","first-page":"267","article-title":"Cytokinins - recent news and views of evolutionally old molecules","volume":"39","author":"Funct","year":"2012","journal-title":"Plant Biol."},{"key":"10.1016\/j.aca.2023.342010_bib8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/bs.ircmb.2016.01.001","article-title":"Cytokinin synthesis, signaling, and function\u2014advances and new insights","volume":"324","author":"Zurcher","year":"2016","journal-title":"Int. Rev. Cell Mol. Biol."},{"key":"10.1016\/j.aca.2023.342010_bib9","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1007\/s00425-014-2063-9","article-title":"Quo vadis plant hormone analysis?","volume":"240","author":"Tarkowska","year":"2014","journal-title":"Planta"},{"key":"10.1016\/j.aca.2023.342010_bib10","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1146\/annurev-arplant-042916-040812","article-title":"Zooming in on plant hormone analysis: tissue- and cell-specific approaches","volume":"68","author":"Novak","year":"2017","journal-title":"Annu. Rev. Plant Biol."},{"key":"10.1016\/j.aca.2023.342010_bib11","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/0009-2509(56)80003-1","article-title":"Longitudinal diffusion and resistance to mass transfer as causes of nonideality in chromatography","volume":"5","author":"Van Deemter","year":"1956","journal-title":"Chem. Eng. Sci."},{"key":"10.1016\/j.aca.2023.342010_bib12","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1186\/1746-4811-8-17","article-title":"A new approach for cytokinin isolation from Arabidopsis tissues using miniaturized purification: pipette tip solid-phase extraction","volume":"8","author":"Svacinova","year":"2012","journal-title":"Plant Methods"},{"key":"10.1016\/j.aca.2023.342010_bib13","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1104\/pp.18.00293","article-title":"Plant hormonomics: multiple phytohormone profiling by targeted metabolomics","volume":"177","author":"Simura","year":"2018","journal-title":"Plant Physiol."},{"key":"10.1016\/j.aca.2023.342010_bib14","article-title":"Current state of supercritical fluid chromatography-mass spectrometry","volume":"142","author":"Gazarkova","year":"2022","journal-title":"Trends Anal. Chem."},{"key":"10.1016\/j.aca.2023.342010_bib15","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1002\/jlcr.3702","article-title":"Synthesis of [15N4] purine labeled cytokinin glycosides derived from zeatins and topolins with 9\u2010\u03b2\u2010D, 7\u2010\u03b2\u2010D\u2010glucopyranosyl, or 9\u2010\u03b2\u2010D\u2010ribofuranosyl group","volume":"62","author":"Tranova","year":"2019","journal-title":"J. Label. Compd. Radiopharm."},{"key":"10.1016\/j.aca.2023.342010_bib16","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/S0021-9673(02)00024-9","article-title":"Fast and efficient separation of cytokinins from auxin and abscisic acid and their purification using mixed-mode solid-phase extraction","volume":"950","author":"Dobrev","year":"2002","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2023.342010_bib17","article-title":"Matrix-matched monitoring ion selection strategy for improving the matrix effect and qualitative accuracy in pesticide detection based on UFLC-ESI-MS\/MS: a case of Chrysanthemum","volume":"160","author":"Quin","year":"2021","journal-title":"Microchem. J."},{"key":"10.1016\/j.aca.2023.342010_bib18","doi-asserted-by":"crossref","first-page":"3019","DOI":"10.1021\/ac020361s","article-title":"Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS\/MS","volume":"75","author":"Matuszewski","year":"2003","journal-title":"Anal. Chem."},{"key":"10.1016\/j.aca.2023.342010_bib19","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1016\/j.jpba.2015.03.007","article-title":"Supercritical fluid chromatography in pharmaceutical analysis","volume":"113","author":"Desfontaine","year":"2015","journal-title":"J. Pharm. Biomed. Anal."},{"key":"10.1016\/j.aca.2023.342010_bib20","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.aca.2016.02.010","article-title":"Fast and sensitive supercritical fluid chromatography - tandem mass spectrometry multi-class screening method for the determination of doping agents in urine","volume":"915","author":"Novakova","year":"2016","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2023.342010_bib21","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.chroma.2012.10.005","article-title":"Comparison of ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography for the analysis of pharmaceutical compounds","volume":"1266","author":"Perrenoud","year":"2012","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2023.342010_bib22","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/j.aca.2015.03.003","article-title":"Development and validation of ultra-high performance supercritical fluid chromatography method for determination of illegal dyes and comparison to ultra-high performance liquid chromatography method","volume":"874","author":"Khalikova","year":"2015","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2023.342010_bib23","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.jpba.2015.12.002","article-title":"Comparison of ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography for the separation of spirostanol saponins","volume":"120","author":"Zhu","year":"2016","journal-title":"J. Pharm. Biomed. Anal."},{"key":"10.1016\/j.aca.2023.342010_bib24","doi-asserted-by":"crossref","first-page":"1535","DOI":"10.1021\/ac052025s","article-title":"Feasibility of supercritical fluid chromatography\/mass spectrometry of polypeptides with up to 40-mers","volume":"78","author":"Zheng","year":"2006","journal-title":"Anal. Chem."},{"key":"10.1016\/j.aca.2023.342010_bib25","doi-asserted-by":"crossref","first-page":"6441","DOI":"10.1016\/j.chroma.2009.07.022","article-title":"Effect of increasing concentration of ammonium acetate as an additive in supercritical fluid chromatography using CO2-methanol mobile phase","volume":"1216","author":"Cazenave-Gassiot","year":"2009","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2023.342010_bib26","doi-asserted-by":"crossref","DOI":"10.1016\/j.chroma.2019.460582","article-title":"Usual, unusual and unbelievable retention behavior in achiral supercritical fluid chromatography: review and discussion","volume":"1614","author":"Lesellier","year":"2020","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2023.342010_bib28","doi-asserted-by":"crossref","DOI":"10.1016\/j.chroma.2019.460726","article-title":"Ion exchange in supercritical fluid chromatography tandem mass spectrometry (SFC-MS\/MS): application for polar and ionic drugs and metabolites in forensic and anti-doping analysis","volume":"1614","author":"Xhaferaj","year":"2020","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2023.342010_bib27","doi-asserted-by":"crossref","first-page":"1037","DOI":"10.1016\/j.chroma.2010.12.047","article-title":"Fundamental challenges and opportunities for preparative supercritical fluid Chromatography","volume":"1218","author":"Guiochon","year":"2011","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2023.342010_bib29","doi-asserted-by":"crossref","DOI":"10.1016\/j.trac.2021.116464","article-title":"Effect of water addition to super\/sub-critical fluid mobile-phases for achiral and chiral separations","volume":"145","author":"Roy","year":"2021","journal-title":"Trends Anal. Chem."},{"key":"10.1016\/j.aca.2023.342010_bib30","doi-asserted-by":"crossref","first-page":"3856","DOI":"10.1021\/ac062441s","article-title":"Supercritical fluid chromatography and high-performance liquid chromatography\/tandem mass spectrometric methods for the determination of cytarabine in mouse plasma","volume":"79","author":"Hsieh","year":"2007","journal-title":"Anal. Chem."},{"key":"10.1016\/j.aca.2023.342010_bib31","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.chroma.2018.05.055","article-title":"Applicability of supercritical fluid chromatography - mass spectrometry to metabolomics. I - optimization of separation conditions for the simultaneous analysis of hydrophilic and lipophilic substances","volume":"1562","author":"Desfontaine","year":"2018","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2023.342010_bib32","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.jpha.2019.05.001","article-title":"Simultaneous determination of amino acids in different teas using supercritical fluid chromatography coupled with single quadrupole mass spectrometry","volume":"9","author":"Huang","year":"2019","journal-title":"J. Pharm. Anal."},{"key":"10.1016\/j.aca.2023.342010_bib33","doi-asserted-by":"crossref","DOI":"10.1016\/j.chroma.2019.460780","article-title":"Supercritical fluid chromatography-mass spectrometry in routine anti-doping analyses: estimation of retention time variability under reproducible conditions","volume":"1616","author":"Losacco","year":"2020","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2023.342010_bib34","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.aca.2018.06.013","article-title":"Development and validation of ultra-high performance supercritical fluid chromatography method for quantitative determination of nine sunscreens in cosmetic samples","volume":"1034","author":"Khalikova","year":"2018","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2023.342010_bib35","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.chroma.2016.04.040","article-title":"Analysis of polar urinary metabolites for metabolic phenotyping using supercritical fluid chromatography and mass spectrometry","volume":"1449","author":"Sen","year":"2016","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2023.342010_bib36","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.chroma.2007.03.056","article-title":"Viscous fingering in packed chromatographic columns: linear stability analysis","volume":"1149","author":"Rosseaux","year":"2007","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2023.342010_bib37","doi-asserted-by":"crossref","first-page":"8353","DOI":"10.1016\/j.chroma.2011.09.040","article-title":"Viscous fingering in packed chromatographic columns: non-linear dynamics","volume":"1218","author":"Rosseaux","year":"2011","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2023.342010_bib38","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.chroma.2017.06.075","article-title":"A systematic investigation of sample diluents in modern supercritical fluid chromatography","volume":"1511","author":"Desfontaine","year":"2017","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2023.342010_bib39","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1080\/10826076.2011.565540","article-title":"Viscosity estimation in binary and ternary supercritical fluid mixtures containing carbon dioxide using a supercritical fluid chromatograph","volume":"34","author":"Fields","year":"2011","journal-title":"J. Liq. Chromatogr. Relat."},{"key":"10.1016\/j.aca.2023.342010_bib40","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.chroma.2014.03.006","article-title":"Coupling state-of-the-art supercritical fluid chromatography and mass spectrometry: from hyphenation interface optimization to high-sensitivity analysis of pharmaceutical compounds","volume":"1339","author":"Perrenoud","year":"2014","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2023.342010_bib41","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1016\/j.aca.2014.10.004","article-title":"Ultra high performance supercritical fluid chromatography coupledwith tandem mass spectrometry for screening of doping agents. I: investigation of mobile phase and MS conditions","volume":"853","author":"Novakova","year":"2015","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2023.342010_bib42","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.aca.2018.07.008","article-title":"Ultra-high performance supercritical fluid chromatography in impurity control: searching for generic screening approach","volume":"1039","author":"Plachka","year":"2018","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2023.342010_bib43","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.trac.2018.12.023","article-title":"Recent developments in supercritical fluid chromatography - mass spectrometry: is it a viable option for analysis of complex samples?","volume":"112","author":"Pilarova","year":"2019","journal-title":"Trends Anal. Chem."},{"key":"10.1016\/j.aca.2023.342010_bib44","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/j.aca.2014.10.007","article-title":"Ultra high performance supercritical fluid chromatography coupled with tandem mass spectrometry for screening of doping agents. II: analysis of biological samples","volume":"853","author":"Novakova","year":"2015","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2023.342010_bib45","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/j.chroma.2016.05.004","article-title":"Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine","volume":"1451","author":"Desfontaine","year":"2016","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2023.342010_bib46","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.aca.2017.10.014","article-title":"The differences in matrix effect between supercritical fluid chromatography and reversed phase liquid chromatography coupled to ESI\/MS","volume":"1000","author":"Svan","year":"2018","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2023.342010_bib47","series-title":"Introduction to Modern Liquid Chromatography","author":"Snyder","year":"2009"},{"key":"10.1016\/j.aca.2023.342010_bib48","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1111\/tpj.13443","article-title":"Microscale magnetic microparticle-based immunopurification of cytokinins from Arabidopsis root apex","volume":"89","author":"Plackova","year":"2017","journal-title":"Plant J."},{"key":"10.1016\/j.aca.2023.342010_bib49","doi-asserted-by":"crossref","first-page":"2423","DOI":"10.1111\/nph.16310","article-title":"Distinct metabolism of N-glucosides of isopentenyladenine and trans-zeatin determines cytokinin metabolic spectrum in Arabidopsis","volume":"225","author":"Hosek","year":"2020","journal-title":"New Phytol."}],"container-title":["Analytica Chimica Acta"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S000326702301231X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S000326702301231X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,2]],"date-time":"2025-11-02T11:45:44Z","timestamp":1762083944000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S000326702301231X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":49,"alternative-id":["S000326702301231X"],"URL":"https:\/\/doi.org\/10.1016\/j.aca.2023.342010","relation":{},"ISSN":["0003-2670"],"issn-type":[{"value":"0003-2670","type":"print"}],"subject":[],"published":{"date-parts":[[2024,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Rapid profiling of cytokinins using supercritical fluid chromatography coupled with tandem mass spectrometry","name":"articletitle","label":"Article Title"},{"value":"Analytica Chimica Acta","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.aca.2023.342010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"342010"}}