{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T12:52:41Z","timestamp":1792155161044,"version":"4.4.0"},"reference-count":42,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"funder":[{"DOI":"10.13039\/501100001824","name":"Grantov\u00e1 Agentura \u010cesk\u00e9 Republiky","doi-asserted-by":"publisher","award":["23-05972S"],"award-info":[{"award-number":["23-05972S"]}],"id":[{"id":"10.13039\/501100001824","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004240","name":"Akademie V\u011bd \u010cesk\u00e9 Republiky","doi-asserted-by":"publisher","award":["68081715"],"award-info":[{"award-number":["68081715"]}],"id":[{"id":"10.13039\/501100004240","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100014440","name":"Ministerio de Ciencia, Innovaci\u00f3n y Universidades","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100014440","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100011033","name":"Agencia Estatal de Investigaci\u00f3n","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100011033","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Analytica Chimica Acta"],"published-print":{"date-parts":[[2026,11]]},"DOI":"10.1016\/j.aca.2026.346234","type":"journal-article","created":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T15:34:56Z","timestamp":1788795296000},"page":"346234","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Automatic analyses of quantitative dried material spots by on-line coupling of sequential injection to high-performance liquid chromatography: A proof-of-concept"],"prefix":"10.1016","volume":"1424","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9245-1639","authenticated-orcid":false,"given":"Milo\u0161","family":"Dvo\u0159\u00e1k","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4468-4593","authenticated-orcid":false,"given":"Carlos","family":"Pagan-Galbarro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manuel","family":"Mir\u00f3","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8928-9255","authenticated-orcid":false,"given":"Pavel","family":"Kub\u00e1\u0148","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.aca.2026.346234_bib1","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1111\/jvh.13890","article-title":"The role of dried blood spot tests in the detection of hepatitis B infection: a systematic review","volume":"31","author":"Virtudazo","year":"2024","journal-title":"J. Viral Hepat."},{"key":"10.1016\/j.aca.2026.346234_bib2","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1002\/ansa.202300011","article-title":"Blood microsampling technologies: innovations and applications in 2022","volume":"4","author":"Thangavelu","year":"2023","journal-title":"Anal. Sci. Adv"},{"key":"10.1016\/j.aca.2026.346234_bib3","doi-asserted-by":"crossref","DOI":"10.1002\/jssc.202300210","article-title":"Dried blood spot analysis with liquid chromatography and mass spectrometry: trends in clinical chemistry","volume":"46","author":"Skogvold","year":"2023","journal-title":"J. Separ. Sci."},{"key":"10.1016\/j.aca.2026.346234_bib4","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1097\/FTD.0000000000001082","article-title":"Dried blood spot sampling in the monitoring of anticancer therapy for solid tumors: a systematic review","volume":"45","author":"Shafiei","year":"2023","journal-title":"Ther. Drug Monit."},{"key":"10.1016\/j.aca.2026.346234_bib5","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1080\/17512433.2023.2224562","article-title":"Dried blood spot sampling for therapeutic drug monitoring: challenges and opportunities","volume":"16","author":"M\u00fcnller","year":"2023","journal-title":"Expert Rev. Clin. Pharmacol."},{"key":"10.1016\/j.aca.2026.346234_bib6","doi-asserted-by":"crossref","first-page":"681","DOI":"10.3390\/ijms24010681","article-title":"Volumetric absorptive microsampling in therapeutic drug monitoring of immunosuppressive drugs-from sampling and analytical issues to clinical application","volume":"24","author":"Kocur","year":"2023","journal-title":"Int. J. Mol. Sci."},{"key":"10.1016\/j.aca.2026.346234_bib7","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1097\/FTD.0000000000001083","article-title":"Applications of volumetric absorptive microsampling technique: a systematic critical review","volume":"45","author":"Dodeja","year":"2023","journal-title":"Ther. Drug Monit."},{"key":"10.1016\/j.aca.2026.346234_bib8","doi-asserted-by":"crossref","DOI":"10.1016\/j.chroma.2022.463724","article-title":"Dried blood microsampling-assisted therapeutic drug monitoring of immunosuppressants: an overview","volume":"1689","author":"Deprez","year":"2023","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2026.346234_bib9","doi-asserted-by":"crossref","first-page":"1038","DOI":"10.3390\/metabo13101038","article-title":"Volumetric absorptive microsampling in the analysis of endogenous metabolites","volume":"13","author":"de S\u00e1 e Silva","year":"2023","journal-title":"Metabolites"},{"key":"10.1016\/j.aca.2026.346234_bib10","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1134\/S1061934822040104","article-title":"Dried samples of biological fluids on porous membranes as a promising sample preparation method for biomedical and veterinary diagnostics","volume":"77","author":"Samsonova","year":"2022","journal-title":"J. Anal. Chem."},{"key":"10.1016\/j.aca.2026.346234_bib11","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.aca.2018.09.004","article-title":"(T)utorial: Volumetric absorptive microsampling (VAMS)","volume":"1046","author":"Protti","year":"2019","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2026.346234_bib12","series-title":"Dried Blood Spots. Applications and Techniques","author":"Li","year":"2014"},{"key":"10.1016\/j.aca.2026.346234_bib13","doi-asserted-by":"crossref","first-page":"2023","DOI":"10.4155\/bio.13.156","article-title":"Hemato-critical issues in quantitative analysis of dried blood spots: challenges and solutions","volume":"5","author":"De Kesel","year":"2013","journal-title":"Bioanalysis"},{"key":"10.1016\/j.aca.2026.346234_bib14","doi-asserted-by":"crossref","first-page":"1871","DOI":"10.4155\/bio.14.151","article-title":"Current strategies for coping with the hematocrit problem in dried blood spot analysis","volume":"6","author":"De Kesel","year":"2014","journal-title":"Bioanalysis"},{"key":"10.1016\/j.aca.2026.346234_bib15","doi-asserted-by":"crossref","first-page":"2147","DOI":"10.4155\/bio.13.170","article-title":"The effect of hematocrit on bioanalysis of DBS: results from the EBF DBS-microsampling consortium","volume":"5","author":"de Vries","year":"2013","journal-title":"Bioanalysis"},{"key":"10.1016\/j.aca.2026.346234_bib16","doi-asserted-by":"crossref","DOI":"10.1126\/scitranslmed.abh3826","article-title":"Undiagnosed SARS-CoV-2 seropositivity during the first 6 months of the COVID-19 pandemic in the United States","volume":"13","author":"Kalish","year":"2021","journal-title":"Sci. Transl. Med."},{"key":"10.1016\/j.aca.2026.346234_bib17","doi-asserted-by":"crossref","DOI":"10.1016\/j.jpba.2020.113597","article-title":"Quantitative microsampling for bioanalytical applications related to the SARS-CoV-2 pandemic: usefulness, benefits and pitfalls","volume":"191","author":"Protti","year":"2020","journal-title":"J. Pharm. Biomed. Anal."},{"key":"10.1016\/j.aca.2026.346234_bib26","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.clinbiochem.2020.02.007","article-title":"The application of fully automated dried blood spot analysis for liquid chromatography-tandem mass spectrometry using the CAMAG DBS-MS 500 autosampler","volume":"82","author":"Luginb\u00fchl","year":"2020","journal-title":"Clin. Biochem."},{"key":"10.1016\/j.aca.2026.346234_bib27","doi-asserted-by":"crossref","first-page":"6068","DOI":"10.1002\/anie.202012997","article-title":"Dried blood spot self-sampling with automated capillary electrophoresis processing for clinical analysis","volume":"60","author":"Ry\u0161av\u00e1","year":"2021","journal-title":"Angew. Chem. Int. Ed."},{"key":"10.1016\/j.aca.2026.346234_bib28","doi-asserted-by":"crossref","DOI":"10.1016\/j.aca.2023.341390","article-title":"Autonomous capillary electrophoresis processing and analysis of dried blood spots for high-throughput determination of uric acid","volume":"1267","author":"Morav\u010d\u00edk","year":"2023","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2026.346234_bib29","doi-asserted-by":"crossref","first-page":"11823","DOI":"10.1021\/acs.analchem.3c02474","article-title":"Capillary electrophoresis with interchangeable cartridges for versatile and automated analyses of dried blood spot samples","volume":"95","author":"Dvo\u0159\u00e1k","year":"2023","journal-title":"Anal. Chem."},{"key":"10.1016\/j.aca.2026.346234_bib30","doi-asserted-by":"crossref","DOI":"10.1016\/j.aca.2024.342718","article-title":"Automated analyses of dried blood spots collected by volumetric microsampling devices","volume":"1310","author":"Dvo\u0159\u00e1k","year":"2024","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2026.346234_bib31","doi-asserted-by":"crossref","DOI":"10.1016\/j.talanta.2024.127253","article-title":"Rapid determination of phenylalanine and tyrosine in volumetrically collected dried blood spots using fully automated processing and analysis by capillary electrophoresis","volume":"284","author":"Aranda-Merino","year":"2025","journal-title":"Talanta"},{"key":"10.1016\/j.aca.2026.346234_bib32","article-title":"Automated capillary electrophoresis analyses of dried blood samples after patient-centric volumetric absorptive microsampling","volume":"13","author":"Mar\u0161ala","year":"2025","journal-title":"Adv. Sample Prep."},{"key":"10.1016\/j.aca.2026.346234_bib33","doi-asserted-by":"crossref","DOI":"10.1016\/j.jchromb.2023.123721","article-title":"New perspectives for the therapeutic drug monitoring of tacrolimus: quantification in volumetric DBS based on an automated extraction and LC-MS\/MS analysis","volume":"1223","author":"Ros\u00e9","year":"2023","journal-title":"J. Chromatogr. B"},{"key":"10.1016\/j.aca.2026.346234_bib34","article-title":"Sorbent-less dried blood spot microsampling","volume":"16","author":"Dvo\u0159\u00e1k","year":"2025","journal-title":"Adv. Sample Prep."},{"key":"10.1016\/j.aca.2026.346234_bib35","doi-asserted-by":"crossref","first-page":"6227","DOI":"10.1007\/s00216-015-8834-8","article-title":"CocoSoft: educational software for automation in the analytical chemistry laboratory","volume":"407","author":"Cocovi-Solberg","year":"2015","journal-title":"Anal. Bioanal. Chem."},{"key":"10.1016\/j.aca.2026.346234_bib36","doi-asserted-by":"crossref","first-page":"12541","DOI":"10.1021\/acs.analchem.7b03767","article-title":"3D-Printed microflow injection analysis platform for online magnetic nanoparticle sorptive extraction of antimicrobials in biological specimens as a front end to liquid chromatographic assays","volume":"89","author":"Wang","year":"2017","journal-title":"Anal. Chem."},{"key":"10.1016\/j.aca.2026.346234_bib37","doi-asserted-by":"crossref","first-page":"8783","DOI":"10.1021\/ac301996n","article-title":"Alginate and Chitosan foam combined with electromembrane extraction for dried blood spot analysis","volume":"84","author":"Eibak","year":"2012","journal-title":"Anal. Chem."},{"key":"10.1016\/j.aca.2026.346234_bib38","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/j.jpba.2017.02.060","article-title":"Whole blood microsampling for the quantitation of estetrol without derivatization by liquid chromatography-tandem mass spectrometry","volume":"140","author":"Nys","year":"2017","journal-title":"J. Pharm. Biomed. Anal."},{"key":"10.1016\/j.aca.2026.346234_bib39","doi-asserted-by":"crossref","DOI":"10.1016\/j.aca.2023.340793","article-title":"Fully soluble polymeric foams for in-vial dried blood spot collection and analysis of acidic drugs by capillary electrophoresis","volume":"1241","author":"Ry\u0161av\u00e1","year":"2023","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.aca.2026.346234_bib40","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.chroma.2016.12.009","article-title":"Sampling only ten microliters of whole blood for the quantification of poorly soluble drugs: itraconazole as case study","volume":"1479","author":"Thiry","year":"2017","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2026.346234_bib41","doi-asserted-by":"crossref","first-page":"10076","DOI":"10.1021\/acs.analchem.0c01887","article-title":"AGREE-analytical GREEnness metric approach and software","volume":"92","author":"Pena-Pereira","year":"2020","journal-title":"Anal. Chem."},{"key":"10.1016\/j.aca.2026.346234_bib42","series-title":"Statistics and Chemometrics for Analytical Chemistry","author":"Miller","year":"2010"},{"key":"10.1016\/j.aca.2026.346234_bib43","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1002\/dta.3781","article-title":"Quantitative analysis of nonsteroidal anti-inflammatory drugs in dried blood spot from mountain ultra-trail runners. Contribution of pharmacokinetic models for the interpretation of the results","volume":"17","author":"Mashal","year":"2025","journal-title":"Drug Test. Anal."},{"key":"10.1016\/j.aca.2026.346234_bib46","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1186\/s13054-020-02915-5","article-title":"Revisited: therapeutic and toxic blood concentrations of more than 1100 drugs and other xenobiotics","volume":"24","author":"Schulz","year":"2020","journal-title":"Crit. Care"},{"key":"10.1016\/j.aca.2026.346234_bib47","doi-asserted-by":"crossref","first-page":"1501","DOI":"10.4155\/bio.10.51","article-title":"Determination of naproxen using DBS: evaluation & pharmacokinetic comparison of human plasma versus human blood DBS","volume":"2","author":"Youhnovski","year":"2010","journal-title":"Bioanalysis"},{"key":"10.1016\/j.aca.2026.346234_bib48","doi-asserted-by":"crossref","first-page":"3858","DOI":"10.1039\/D1AN00446H","article-title":"An automatic flow-through system for exploration of the human bioaccessibility of endocrine disrupting compounds from microplastics","volume":"146","author":"Sixto","year":"2021","journal-title":"Analyst"},{"key":"10.1016\/j.aca.2026.346234_bib49","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.talanta.2016.04.062","article-title":"Rapid estimation of readily leachable triazine residues in soils using automatic kinetic bioaccessibility assays followed by on-line sorptive clean-up as a front-end to liquid chromatography","volume":"156","author":"Vida","year":"2016","journal-title":"Talanta"},{"key":"10.1016\/j.aca.2026.346234_bib50","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.chroma.2003.12.036","article-title":"Automated sample preparation based on the sequential injection principle - solid-phase extraction on a molecularly imprinted polymer coupled on-line to high-performance liquid chromatography","volume":"1030","author":"Theodoridis","year":"2004","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.aca.2026.346234_bib51","doi-asserted-by":"crossref","first-page":"2819","DOI":"10.1002\/jssc.200900102","article-title":"Automated zone-sampling dilution by coupling sequential injection analysis to high-throughput HPLC for the direct determination of gemfibrozil","volume":"32","author":"Tzanavaras","year":"2009","journal-title":"J. Separ. Sci."},{"key":"10.1016\/j.aca.2026.346234_bib52","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.jchromb.2004.05.003","article-title":"On-line coupling of sequential injection with liquid chromatography for the automated derivatization and determination of \u03b3-aminobutyric acid in human biological fluids","volume":"808","author":"Zacharis","year":"2004","journal-title":"J. Chromatogr. B"}],"container-title":["Analytica Chimica Acta"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003267026011840?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0003267026011840?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T12:21:07Z","timestamp":1792153267000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0003267026011840"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,11]]},"references-count":42,"alternative-id":["S0003267026011840"],"URL":"https:\/\/doi.org\/10.1016\/j.aca.2026.346234","relation":{},"ISSN":["0003-2670"],"issn-type":[{"value":"0003-2670","type":"print"}],"subject":[],"published":{"date-parts":[[2026,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Automatic analyses of quantitative dried material spots by on-line coupling of sequential injection to high-performance liquid chromatography: A proof-of-concept","name":"articletitle","label":"Article Title"},{"value":"Analytica Chimica Acta","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.aca.2026.346234","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"346234"}}