{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,9]],"date-time":"2025-12-09T15:39:20Z","timestamp":1765294760893},"reference-count":20,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2015,12,1]],"date-time":"2015-12-01T00:00:00Z","timestamp":1448928000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Anaesthesia Critical Care &amp; Pain Medicine"],"published-print":{"date-parts":[[2015,12]]},"DOI":"10.1016\/j.accpm.2015.06.008","type":"journal-article","created":{"date-parts":[[2015,10,30]],"date-time":"2015-10-30T22:24:25Z","timestamp":1446243865000},"page":"345-348","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["Baseline cerebral oximetry values depend on non-modifiable patient characteristics"],"prefix":"10.1016","volume":"34","author":[{"given":"Luc\u00eda","family":"Valencia","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aurelio","family":"Rodr\u00edguez-P\u00e9rez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nazario","family":"Ojeda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Romen Yone","family":"Santana","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laura","family":"Morales","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oto","family":"Padr\u00f3n","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.accpm.2015.06.008_bib0105","first-page":"10","article-title":"Cerebral oximetry: emerging applications for an established technology","volume":"38","author":"Elizabeth","year":"2012","journal-title":"Anesthesiol News"},{"key":"10.1016\/j.accpm.2015.06.008_bib0110","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1213\/01.ane.0000246814.29362.f4","article-title":"Monitoring brain oxygen saturation during coronary bypass surgery: a randomized, prospective study","volume":"104","author":"Murkin","year":"2007","journal-title":"Anesth Analg"},{"key":"10.1016\/j.accpm.2015.06.008_bib0115","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1093\/bja\/aep309","article-title":"Reduced cerebral oxygen saturation measured by absolute cerebral oximetry during thoracic surgery correlates with postoperative complications","volume":"103","author":"Kazan","year":"2009","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.accpm.2015.06.008_bib0120","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1093\/bja\/aer501","article-title":"Reduced cerebral oxygen saturation during thoracic surgery predicts early postoperative cognitive dysfunction","volume":"108","author":"Tang","year":"2012","journal-title":"Br J Anaesth"},{"key":"10.1016\/j.accpm.2015.06.008_bib0125","doi-asserted-by":"crossref","first-page":"740","DOI":"10.1213\/01.ane.0000166974.96219.cd","article-title":"Continuous monitoring of cerebral oxygen saturation in elderly patients undergoing major abdominal surgery minimizes brain exposure to potential hypoxia","volume":"101","author":"Casati","year":"2005","journal-title":"Anesth Analg"},{"key":"10.1016\/j.accpm.2015.06.008_bib0130","first-page":"59","article-title":"Monitoring cerebral oxygen saturation in elderly patients undergoing general abdominal surgery: a prospective cohort study","volume":"24","author":"Casati","year":"2007","journal-title":"Eur J Anaesthesiol"},{"key":"10.1016\/j.accpm.2015.06.008_bib0135","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1097\/ACO.0b013e32833e1536","article-title":"Noninvasive cerebral oximetry: is there light at the end of the tunnel?","volume":"23","author":"Highton","year":"2010","journal-title":"Curr Opin Anaesthesiol"},{"key":"10.1016\/j.accpm.2015.06.008_bib0140","doi-asserted-by":"crossref","first-page":"e59","DOI":"10.1016\/j.annfar.2013.12.020","article-title":"Does sevoflurane preserve regional cerebral oxygen saturation measured by near-infrared spectroscopy better than propofol?","volume":"33","author":"Valencia","year":"2014","journal-title":"Ann Fr Anesth Reanim"},{"key":"10.1016\/j.accpm.2015.06.008_bib0145","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1097\/00008506-200310000-00002","article-title":"Influence of patient variables and sensor location on regional cerebral oxygen saturation measured by INVOS 4100 near-infrared spectrophotometers","volume":"15","author":"Kishi","year":"2003","journal-title":"J Neurosurg Anesthesiol"},{"key":"10.1016\/j.accpm.2015.06.008_bib0150","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1080\/01616412.1998.11740496","article-title":"Transcranial cerebral oximetry in random normal subjects","volume":"20","author":"Misra","year":"1998","journal-title":"Neurol Res"},{"key":"10.1016\/j.accpm.2015.06.008_bib0155","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1016\/j.injury.2011.04.015","article-title":"Baseline cerebral oximetry values in elderly patients with hip fractures: a prospective observational study","volume":"42","author":"Papadopoulos","year":"2011","journal-title":"Injury"},{"key":"10.1016\/j.accpm.2015.06.008_bib0160","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1097\/ALN.0b013e3181fef34e","article-title":"Preoperative cerebral oxygen saturation and clinical outcomes in cardiac surgery","volume":"114","author":"Heringlake","year":"2011","journal-title":"Anesthesiology"},{"key":"10.1016\/j.accpm.2015.06.008_bib0165","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1023\/A:1024190429920","article-title":"Frontal lobe and cognitive development","volume":"31","author":"Fuster","year":"2002","journal-title":"J Neurocytol"},{"key":"10.1016\/j.accpm.2015.06.008_bib0170","doi-asserted-by":"crossref","first-page":"1177","DOI":"10.1038\/jcbfm.2012.18","article-title":"Brain energy metabolism and blood flow differences in healthy aging","volume":"32","author":"Aanerud","year":"2012","journal-title":"J Cereb Blood Flow Metab"},{"issue":"5","key":"10.1016\/j.accpm.2015.06.008_bib0175","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1186\/1749-8090-5-41","article-title":"Baseline cerebral oximetry values in cardiac and vascular surgery patients: a prospective observational study","volume":"24","author":"Baikoussis","year":"2010","journal-title":"J Cardiothorac Surg"},{"key":"10.1016\/j.accpm.2015.06.008_bib0180","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1111\/j.1751-7133.2011.00284.x","article-title":"Initial description of cerebral oximetry measurement in heart failure patients","volume":"18","author":"Rifai","year":"2012","journal-title":"Congest Heart Fail"},{"key":"10.1016\/j.accpm.2015.06.008_bib0185","doi-asserted-by":"crossref","first-page":"855","DOI":"10.3109\/0886022X.2013.794675","article-title":"Cerebral oximetry values in dialyzed surgical patients: a comparison between hemodialysis and peritoneal dialysis","volume":"35","author":"Papadopoulos","year":"2013","journal-title":"Ren Fail"},{"key":"10.1016\/j.accpm.2015.06.008_bib0190","doi-asserted-by":"crossref","first-page":"1861","DOI":"10.1038\/sj.jcbfm.9600478","article-title":"Cerebrovascular effects of hemodialysis in chronic kidney disease","volume":"27","author":"Prohovnik","year":"2007","journal-title":"J Cereb Blood Flow Metab"},{"key":"10.1016\/j.accpm.2015.06.008_bib0195","first-page":"605","article-title":"New technology for noninvasive brain monitoring: continuous cerebral oximetry","volume":"72","author":"Casati","year":"2006","journal-title":"Minerva Anestesiol"},{"key":"10.1016\/j.accpm.2015.06.008_bib0200","first-page":"249","article-title":"Cerebral oximetry in cardiac and major vascular surgery","volume":"2","author":"Fischer","year":"2010","journal-title":"HSR Proc Intensive Care Cardiovasc Anesth"}],"container-title":["Anaesthesia Critical Care &amp; Pain Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352556815001113?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352556815001113?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,18]],"date-time":"2018-09-18T05:20:55Z","timestamp":1537248055000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352556815001113"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,12]]},"references-count":20,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2015,12]]}},"alternative-id":["S2352556815001113"],"URL":"https:\/\/doi.org\/10.1016\/j.accpm.2015.06.008","relation":{},"ISSN":["2352-5568"],"issn-type":[{"value":"2352-5568","type":"print"}],"subject":[],"published":{"date-parts":[[2015,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Baseline cerebral oximetry values depend on non-modifiable patient characteristics","name":"articletitle","label":"Article Title"},{"value":"Anaesthesia Critical Care & Pain Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.accpm.2015.06.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Soci\u00e9t\u00e9 fran\u00e7aise d\u2019anesth\u00e9sie et de r\u00e9animation (Sfar). Published by Elsevier Masson SAS All rights reserved.","name":"copyright","label":"Copyright"}]}}