{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T09:44:30Z","timestamp":1762508670453,"version":"build-2065373602"},"reference-count":25,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T00:00:00Z","timestamp":1643673600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T00:00:00Z","timestamp":1643673600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Anaesthesia Critical Care &amp; Pain Medicine"],"published-print":{"date-parts":[[2022,2]]},"DOI":"10.1016\/j.accpm.2021.101003","type":"journal-article","created":{"date-parts":[[2021,12,11]],"date-time":"2021-12-11T12:31:18Z","timestamp":1639225878000},"page":"101003","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["Haemodynamic monitoring in circulatory shock \u2014 in a nutshell"],"prefix":"10.1016","volume":"41","author":[{"given":"Moritz","family":"Flick","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8107-6952","authenticated-orcid":false,"given":"Karim","family":"Kouz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2888-4111","authenticated-orcid":false,"given":"Michelle S.","family":"Chew","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6619-0722","authenticated-orcid":false,"given":"Bernd","family":"Saugel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"18","key":"10.1016\/j.accpm.2021.101003_bib0005","doi-asserted-by":"crossref","first-page":"1726","DOI":"10.1056\/NEJMra1208943","article-title":"Circulatory shock","volume":"369","author":"Vincent","year":"2013","journal-title":"N Engl J Med"},{"issue":"12","key":"10.1016\/j.accpm.2021.101003_bib0010","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.1007\/s00134-014-3525-z","article-title":"Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine","volume":"40","author":"Cecconi","year":"2014","journal-title":"Intensive Care Med"},{"issue":"3","key":"10.1016\/j.accpm.2021.101003_bib0015","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1097\/01.CCM.0000201896.45809.E3","article-title":"Does dopamine administration in shock influence outcome? Results of the sepsis occurrence in acutely ill patients (SOAP) study","volume":"34","author":"Sakr","year":"2006","journal-title":"Crit Care Med"},{"issue":"6","key":"10.1016\/j.accpm.2021.101003_bib0020","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1186\/cc11510","article-title":"Clinical review: circulatory shock\u2014an update: a tribute to professor Max Harry Weil","volume":"16","author":"Vincent","year":"2012","journal-title":"Crit Care"},{"key":"10.1016\/j.accpm.2021.101003_bib0025","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1186\/s13054-016-1401-7","article-title":"Echocardiography in shock management","volume":"20","author":"McLean","year":"2016","journal-title":"Crit Care"},{"issue":"3","key":"10.1016\/j.accpm.2021.101003_bib0030","first-page":"165","article-title":"Cardiac output monitoring: how to choose the optimal method for the individual patient","volume":"24","author":"Saugel","year":"2018","journal-title":"Curr Opin Crit Care"},{"key":"10.1016\/j.accpm.2021.101003_bib0035","article-title":"The contemporary pulmonary artery catheter. Part 1: placement and waveform analysis","author":"Bootsma","year":"2021","journal-title":"J Clin Monit Comput"},{"key":"10.1016\/j.accpm.2021.101003_bib0040","first-page":"1","article-title":"The contemporary pulmonary artery catheter. Part 2: measurements, limitations, and clinical applications","author":"Bootsma","year":"2021","journal-title":"J Clin Monit Comput"},{"issue":"1","key":"10.1016\/j.accpm.2021.101003_bib0045","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1186\/s13054-021-03523-7","article-title":"Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis","volume":"25","author":"Kouz","year":"2021","journal-title":"Crit Care"},{"issue":"2","key":"10.1016\/j.accpm.2021.101003_bib0050","article-title":"Pulmonary artery catheters for adult patients in intensive care","author":"Rajaram","year":"2013","journal-title":"Cochrane Database Syst Rev"},{"issue":"1","key":"10.1016\/j.accpm.2021.101003_bib0055","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1186\/s13054-017-1739-5","article-title":"Transpulmonary thermodilution: advantages and limits","volume":"21","author":"Monnet","year":"2017","journal-title":"Crit Care"},{"issue":"3","key":"10.1016\/j.accpm.2021.101003_bib0060","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1213\/ANE.0b013e3181cc885a","article-title":"Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives","volume":"110","author":"Reuter","year":"2010","journal-title":"Anesth Analg"},{"issue":"1","key":"10.1016\/j.accpm.2021.101003_bib0065","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1186\/s13613-015-0081-9","article-title":"Extravascular lung water in critical care: recent advances and clinical applications","volume":"5","author":"Jozwiak","year":"2015","journal-title":"Ann Intensive Care"},{"issue":"3","key":"10.1016\/j.accpm.2021.101003_bib0070","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1007\/s00134-006-0498-6","article-title":"Assessing pulmonary permeability by transpulmonary thermodilution allows differentiation of hydrostatic pulmonary edema from ALI\/ARDS","volume":"33","author":"Monnet","year":"2007","journal-title":"Intensive Care Med"},{"issue":"1","key":"10.1016\/j.accpm.2021.101003_bib0075","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.bja.2020.09.049","article-title":"Cardiac output estimation using pulse wave analysis-physiology, algorithms, and technologies: a narrative review","volume":"126","author":"Saugel","year":"2021","journal-title":"Br J Anaesth"},{"issue":"1","key":"10.1016\/j.accpm.2021.101003_bib0080","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1097\/ALN.0000000000003553","article-title":"Pulse wave analysis to estimate cardiac output","volume":"134","author":"Kouz","year":"2021","journal-title":"Anesthesiology"},{"issue":"4","key":"10.1016\/j.accpm.2021.101003_bib0085","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1093\/bja\/aet429","article-title":"Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume variation","volume":"112","author":"Slagt","year":"2014","journal-title":"Br J Anaesth"},{"issue":"5","key":"10.1016\/j.accpm.2021.101003_bib0090","doi-asserted-by":"crossref","first-page":"1220","DOI":"10.1097\/ALN.0b013e3181ee3130","article-title":"Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision","volume":"113","author":"Peyton","year":"2010","journal-title":"Anesthesiology"},{"issue":"1","key":"10.1016\/j.accpm.2021.101003_bib0095","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1164\/rccm.201801-0088CI","article-title":"Arterial pulse pressure variation with mechanical ventilation","volume":"199","author":"Teboul","year":"2019","journal-title":"Am J Respir Crit Care Med"},{"issue":"1","key":"10.1016\/j.accpm.2021.101003_bib0100","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1186\/s13613-021-00817-5","article-title":"Predictors of fluid responsiveness in critically ill patients mechanically ventilated at low tidal volumes: systematic review and meta-analysis","volume":"11","author":"Alvarado Sanchez","year":"2021","journal-title":"Ann Intensive Care"},{"issue":"6","key":"10.1016\/j.accpm.2021.101003_bib0105","doi-asserted-by":"crossref","first-page":"1177","DOI":"10.1007\/s10877-016-9951-4","article-title":"Applicability of stroke volume variation in patients of a general intensive care unit: a longitudinal observational study","volume":"31","author":"Mair","year":"2017","journal-title":"J Clin Monit Comput"},{"issue":"4","key":"10.1016\/j.accpm.2021.101003_bib0110","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1093\/bja\/aet442","article-title":"Evaluation of pulse pressure variation validity criteria in critically ill patients: a prospective observational multicentre point-prevalence study","volume":"112","author":"Mahjoub","year":"2014","journal-title":"Br J Anaesth"},{"issue":"9","key":"10.1016\/j.accpm.2021.101003_bib0115","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1007\/s00134-016-4375-7","article-title":"Less invasive hemodynamic monitoring in critically ill patients","volume":"42","author":"Teboul","year":"2016","journal-title":"Intensive Care Med"},{"issue":"3","key":"10.1016\/j.accpm.2021.101003_bib0120","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1007\/s00134-018-5070-7","article-title":"Second consensus on the assessment of sublingual microcirculation in critically ill patients: results from a task force of the European Society of Intensive Care Medicine","volume":"44","author":"Ince","year":"2018","journal-title":"Intensive Care Med"},{"issue":"6","key":"10.1016\/j.accpm.2021.101003_bib0125","doi-asserted-by":"crossref","first-page":"950","DOI":"10.1007\/s00134-018-5180-2","article-title":"Could resuscitation be based on microcirculation data? We are not sure","volume":"44","author":"Monnet","year":"2018","journal-title":"Intensive Care Med"}],"container-title":["Anaesthesia Critical Care &amp; Pain Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352556821002101?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352556821002101?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T01:48:46Z","timestamp":1762480126000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352556821002101"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,2]]}},"alternative-id":["S2352556821002101"],"URL":"https:\/\/doi.org\/10.1016\/j.accpm.2021.101003","relation":{},"ISSN":["2352-5568"],"issn-type":[{"type":"print","value":"2352-5568"}],"subject":[],"published":{"date-parts":[[2022,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Haemodynamic monitoring in circulatory shock \u2014 in a nutshell","name":"articletitle","label":"Article Title"},{"value":"Anaesthesia Critical Care & Pain Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.accpm.2021.101003","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"simple-article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 Soci\u00e9t\u00e9 fran\u00e7aise d'anesth\u00e9sie et de r\u00e9animation (Sfar). Published by Elsevier Masson SAS. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"101003"}}