{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T17:25:44Z","timestamp":1793985944142,"version":"4.8.0"},"reference-count":25,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,11,1]],"date-time":"2026-11-01T00:00:00Z","timestamp":1793491200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Anaesthesia Critical Care &amp; Pain Medicine"],"published-print":{"date-parts":[[2026,11]]},"DOI":"10.1016\/j.accpm.2026.101843","type":"journal-article","created":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T15:39:23Z","timestamp":1775057963000},"page":"101843","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of time for endotracheal intubation with flexible tip bougie versus standard bougie during videolaryngoscopy in simulated cervical spine immobilization in adult patients \u2013 A randomized control trial"],"prefix":"10.1016","volume":"45","author":[{"given":"Shivam","family":"Shivam","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renu","family":"Sinha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bikash Ranjan","family":"Ray","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Armanullah","family":"Khan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kanil Ranjith","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manpreet","family":"Kaur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V","family":"Darlong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jyotsna","family":"Punj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.accpm.2026.101843_bib0005","doi-asserted-by":"crossref","first-page":"900","DOI":"10.1111\/j.1365-2044.1994.tb04271.x","article-title":"Emergency airway management in patients with cervical spine injuries","volume":"49","author":"Criswell","year":"1994","journal-title":"Anaesthesia"},{"key":"10.1016\/j.accpm.2026.101843_bib0010","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1213\/01.ANE.0000122825.04923.15","article-title":"Emergency tracheal intubation: complications associated with repeated laryngoscopic attempts","volume":"99","author":"Mort","year":"2004","journal-title":"Anesth Analg"},{"key":"10.1016\/j.accpm.2026.101843_bib0015","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1007\/BF03009858","article-title":"The airway: problems and predictions in 18,500 patients","volume":"41","author":"Rose","year":"1994","journal-title":"Can J Anaesth"},{"key":"10.1016\/j.accpm.2026.101843_bib0020","unstructured":"Hagberg and Benumof\u2019s Airway Management, 5th Edition - 9780323795388 n.d. https:\/\/evolve.elsevier.com\/cs\/product\/9780323795388?role=student (accessed August 13, 2025)."},{"key":"10.1016\/j.accpm.2026.101843_bib0025","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1186\/1757-7241-20-85","article-title":"The epidemiology of traumatic cervical spine fractures: a prospective population study from Norway","volume":"20","author":"Fred\u00f8","year":"2012","journal-title":"Scand J Trauma Resusc Emerg Med"},{"key":"10.1016\/j.accpm.2026.101843_bib0030","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1213\/ANE.0000000000003374","article-title":"Airway management practice in adults with an unstable cervical spine: the Harborview Medical Center experience","volume":"127","author":"Holmes","year":"2018","journal-title":"Anesth Analg"},{"key":"10.1016\/j.accpm.2026.101843_bib0035","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.1016\/j.ajem.2017.03.030","article-title":"C-MAC compared with direct laryngoscopy for intubation in patients with cervical spine immobilization: a manikin trial","volume":"35","author":"Smereka","year":"2017","journal-title":"Am J Emerg Med"},{"key":"10.1016\/j.accpm.2026.101843_bib0040","doi-asserted-by":"crossref","first-page":"19","DOI":"10.4103\/2152-7806.199560","article-title":"Comparison of intubation success and glottic visualization using King vision and C-MAC videolaryngoscopes in patients with cervical spine injuries with cervical immobilization: a randomized clinical trial","volume":"8","author":"Shravanalakshmi","year":"2017","journal-title":"Surg Neurol Int"},{"key":"10.1016\/j.accpm.2026.101843_bib0045","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.bjan.2013.06.006","article-title":"Comparison of the conventional CMAC and the D-blade CMAC with the direct laryngoscopes in simulated cervical spine injury\u2014a manikin study","volume":"64","author":"Jain","year":"2014","journal-title":"Braz J Anesthesiol (Engl Ed)"},{"key":"10.1016\/j.accpm.2026.101843_bib0050","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1186\/s12871-020-01118-3","article-title":"Randomized crossover trial comparing cervical spine motion during tracheal intubation with a Macintosh laryngoscope versus a C-MAC D-blade videolaryngoscope in a simulated immobilized cervical spine","volume":"20","author":"Paik","year":"2020","journal-title":"BMC Anesthesiol"},{"key":"10.1016\/j.accpm.2026.101843_bib0055","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1046\/j.1365-2044.2003.03095_12.x","article-title":"Gum elastic bougie and simulated difficult intubation","volume":"58","author":"Green","year":"2003","journal-title":"Anaesthesia"},{"key":"10.1016\/j.accpm.2026.101843_bib0060","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1111\/j.1365-2044.1993.tb07133.x","article-title":"Orotracheal intubation in patients with potential cervical spine injuries. An indication for the gum elastic bougie","volume":"48","author":"Nolan","year":"1993","journal-title":"Anaesthesia"},{"key":"10.1016\/j.accpm.2026.101843_bib0065","doi-asserted-by":"crossref","first-page":"790","DOI":"10.1111\/anae.16574","article-title":"Flexible-tip bougie vs. stylet for tracheal intubation with a hyperangulated videolaryngoscope in critical care: a randomised controlled trial","volume":"80","author":"Taboada","year":"2025","journal-title":"Anaesthesia"},{"key":"10.1016\/j.accpm.2026.101843_bib0070","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/S0196-0644(05)82179-1","article-title":"Oral intubation in the multiply injured patient: the risk of exacerbating spinal cord damage","volume":"19","author":"Rhee","year":"1990","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.accpm.2026.101843_bib0075","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1007\/BF03008461","article-title":"Elective oral tracheal intubation in cervical spine-injured adults","volume":"38","author":"Suderman","year":"1991","journal-title":"Can J Anaesth"},{"key":"10.1016\/j.accpm.2026.101843_bib0080","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1186\/s12871-020-01009-7","article-title":"Comparison of the new flexible tip bougie catheter and standard bougie stylet for tracheal intubation by anesthesiologists in different difficult airway scenarios: a randomized crossover trial","volume":"20","author":"Ruetzler","year":"2020","journal-title":"BMC Anesthesiol"},{"key":"10.1016\/j.accpm.2026.101843_bib0085","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1016\/j.jemermed.2010.05.005","article-title":"Difficulties with gum elastic bougie intubation in an academic emergency department","volume":"41","author":"Shah","year":"2011","journal-title":"J Emerg Med"},{"key":"10.1016\/j.accpm.2026.101843_bib0090","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1111\/anae.15854","article-title":"Standard and flexible tip bougie for tracheal intubation using a non-channelled hyperangulated videolaryngoscope: a randomised comparison<sup\/>","volume":"77","author":"Oxenham","year":"2022","journal-title":"Anaesthesia"},{"key":"10.1016\/j.accpm.2026.101843_bib0095","doi-asserted-by":"crossref","DOI":"10.1155\/2019\/7306204","article-title":"Comparison of different intubation methods in difficult airways during simulated cardiopulmonary resuscitation with continuous chest compression: a randomized cross-over manikin trial","volume":"2019","author":"Evrin","year":"2019","journal-title":"Emerg Med Int"},{"key":"10.1016\/j.accpm.2026.101843_bib0100","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1080\/17434440.2024.2344667","article-title":"Dynamic versus standard bougies for tracheal intubation with direct or indirect laryngoscopy in simulated or real scenarios: a systematic review and meta-analysis","volume":"21","author":"Sastre","year":"2024","journal-title":"Expert Rev Med Devices"},{"key":"10.1016\/j.accpm.2026.101843_bib0105","doi-asserted-by":"crossref","first-page":"1264","DOI":"10.1213\/ANE.0000000000004102","article-title":"Effect of dynamic versus stylet-guided intubation on first-attempt Success in difficult airways undergoing glidescope laryngoscopy: a randomized controlled trial","volume":"128","author":"Mazzinari","year":"2019","journal-title":"Anesth Analg"},{"key":"10.1016\/j.accpm.2026.101843_bib0110","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.redar.2023.08.001","article-title":"Spanish Society of Anesthesiology, Reanimation and Pain Therapy (SEDAR), Spanish Society of Emergency and Emergency Medicine (SEMES) and Spanish Society of Otolaryngology, Head and Neck Surgery (SEORL-CCC) guideline for difficult airway management. Part II","volume":"71","author":"G\u00f3mez-R\u00edos","year":"2024","journal-title":"Rev Esp Anestesiol Reanim (Engl Ed)"},{"key":"10.1016\/j.accpm.2026.101843_bib0115","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1186\/s12245-020-00298-6","article-title":"A randomised crossover comparison of two endotracheal tube introducers: the FROVA and the flexible tip bougie for GlideScope intubation of a difficult airway manikin by infrequent intubators","volume":"13","author":"Cormack","year":"2020","journal-title":"Int J Emerg Med"},{"key":"10.1016\/j.accpm.2026.101843_bib0120","article-title":"The performance of flexible tip bougie\u2122 in intubating simulated difficult airway model","volume":"8","author":"Mahli","year":"2021","journal-title":"Front Med (Lausanne)"},{"key":"10.1016\/j.accpm.2026.101843_bib0125","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1007\/s00540-010-0905-6","article-title":"Is the modified Mallampati test performed in supine position a reliable predictor of difficult tracheal intubation?","volume":"24","author":"Bindra","year":"2010","journal-title":"J Anesth"}],"container-title":["Anaesthesia Critical Care &amp; Pain Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352556826001013?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2352556826001013?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T16:44:42Z","timestamp":1793983482000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2352556826001013"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,11]]},"references-count":25,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,11]]}},"alternative-id":["S2352556826001013"],"URL":"https:\/\/doi.org\/10.1016\/j.accpm.2026.101843","relation":{},"ISSN":["2352-5568"],"issn-type":[{"value":"2352-5568","type":"print"}],"subject":[],"published":{"date-parts":[[2026,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of time for endotracheal intubation with flexible tip bougie versus standard bougie during videolaryngoscopy in simulated cervical spine immobilization in adult patients \u2013 A randomized control trial","name":"articletitle","label":"Article Title"},{"value":"Anaesthesia Critical Care & Pain Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.accpm.2026.101843","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Soci\u00e9t\u00e9 Fran\u00e7aise d'Anesth\u00e9sie et de R\u00e9animation (SFAR). Published by Elsevier Masson SAS. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"101843"}}