{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T16:59:01Z","timestamp":1791305941291,"version":"4.3.1"},"reference-count":32,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2006,1,1]],"date-time":"2006-01-01T00:00:00Z","timestamp":1136073600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Academic Radiology"],"published-print":{"date-parts":[[2006,1]]},"DOI":"10.1016\/j.acra.2005.08.035","type":"journal-article","created":{"date-parts":[[2006,1,5]],"date-time":"2006-01-05T13:26:54Z","timestamp":1136467614000},"page":"63-72","source":"Crossref","is-referenced-by-count":303,"title":["A Fuzzy C-Means (FCM)-Based Approach for Computerized Segmentation of Breast Lesions in Dynamic Contrast-Enhanced MR Images1"],"prefix":"10.1016","volume":"13","author":[{"given":"Weijie","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maryellen L.","family":"Giger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulrich","family":"Bick","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.acra.2005.08.035_bib1","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/S0033-8389(03)00068-4","article-title":"Breast MR imaging","volume":"41","author":"Schnall","year":"2003","journal-title":"Radiol Clin North Am"},{"key":"10.1016\/j.acra.2005.08.035_bib2","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1097\/00004728-198603000-00005","article-title":"MR imaging of the breast using gadolinium-DTPA","volume":"10","author":"Heywang","year":"1986","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.acra.2005.08.035_bib3","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1148\/radiology.171.1.2648479","article-title":"MR imaging of the breast with Gd-DTPA","volume":"171","author":"Heywang","year":"1989","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2005.08.035_bib4","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1148\/radiology.170.3.2916021","article-title":"MR imaging of the breast","volume":"170","author":"Kaiser","year":"1989","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2005.08.035_bib5","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1016\/S0033-8389(01)00005-7","article-title":"Breast cancer imaging with MRI","volume":"40","author":"Morris","year":"2002","journal-title":"Radiol Clin North Am"},{"key":"10.1016\/j.acra.2005.08.035_bib6","doi-asserted-by":"crossref","first-page":"1647","DOI":"10.1118\/1.598345","article-title":"Computerized analysis of breast lesions in three dimensions using dynamic magnetic-resonance imaging","volume":"25","author":"Gilhuijs","year":"1998","journal-title":"Med Phys"},{"key":"10.1016\/j.acra.2005.08.035_bib7","doi-asserted-by":"crossref","first-page":"1076","DOI":"10.1118\/1.1695652","article-title":"Computerized interpretation of breast MRI","volume":"31","author":"Chen","year":"2004","journal-title":"Med Phys"},{"key":"10.1016\/j.acra.2005.08.035_bib8","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1148\/radiology.197.3.7480749","article-title":"Breast tumors","volume":"197","author":"Boetes","year":"1995","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2005.08.035_bib9","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/BF01806626","article-title":"Breast cancer measurements with magnetic resonance imaging, ultrasonography, and mammography","volume":"37","author":"Davis","year":"1996","journal-title":"Breast Cancer Res Treat"},{"key":"10.1016\/j.acra.2005.08.035_bib10","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1007\/s00330-002-1718-2","article-title":"Comparison of lesion size estimated by dynamic MR imaging, mammography and histopathology in breast neoplasms","volume":"13","author":"Wiberg","year":"2003","journal-title":"Eur Radiol"},{"key":"10.1016\/j.acra.2005.08.035_bib11","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1109\/42.730396","article-title":"Automated seeded lesion segmentation on digital mammograms","volume":"17","author":"Kupinski","year":"1998","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1016\/j.acra.2005.08.035_bib12","doi-asserted-by":"crossref","first-page":"1512","DOI":"10.1118\/1.1738960","article-title":"Incorporation of an iterative, linear segmentation routine into a mammographic mass CAD system","volume":"31","author":"Catarious","year":"2004","journal-title":"Med Phys"},{"key":"10.1016\/j.acra.2005.08.035_bib13","doi-asserted-by":"crossref","first-page":"1652","DOI":"10.1118\/1.1386426","article-title":"Automatic segmentation of breast lesions on ultrasound","volume":"28","author":"Horsch","year":"2001","journal-title":"Med Phys"},{"key":"10.1016\/j.acra.2005.08.035_bib14","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1109\/TMI.2002.808364","article-title":"Combining low-, high-level and empirical domain knowledge for automated segmentation of ultrasonic breast lesions","volume":"22","author":"Madabhushi","year":"2003","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1016\/j.acra.2005.08.035_bib15","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1002\/jmri.1880060508","article-title":"Segmentation strategies for breast tumors from dynamic MR images","volume":"6","author":"Lucas-Quesada","year":"1996","journal-title":"J Magn Reson Imaging"},{"key":"10.1016\/j.acra.2005.08.035_bib16","series-title":"Computer-Aided Diagnosis in Medical Imaging","first-page":"305","article-title":"A method for computerized assessment of tumor extent in contrast-enhanced MR images of the breast","author":"Gihuijs","year":"1999"},{"key":"10.1016\/j.acra.2005.08.035_bib17","series-title":"Pattern Recognition With Fuzzy Objective Function Algorithm","author":"Bezdek","year":"1981"},{"key":"10.1016\/j.acra.2005.08.035_bib18","series-title":"Fuzzy Models for Pattern Recognition","author":"Bezdek","year":"1992"},{"key":"10.1016\/j.acra.2005.08.035_bib19","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1118\/1.597000","article-title":"Review of MR image segmentation techniques using pattern recognition","volume":"20","author":"Bezdek","year":"1993","journal-title":"Med Phys"},{"key":"10.1016\/j.acra.2005.08.035_bib20","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1109\/42.802752","article-title":"Adaptive fuzzy segmentation of magnetic resonance images","volume":"18","author":"Pham","year":"1999","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1016\/j.acra.2005.08.035_bib21","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1109\/42.996338","article-title":"A modified fuzzy c-means algorithm for bias field estimation and segmentation of MRI data","volume":"21","author":"Ahmed","year":"2002","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1016\/j.acra.2005.08.035_bib22","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/S0730-725X(97)00277-4","article-title":"Quantification in functional magnetic resonance imaging","volume":"16","author":"Baumgartner","year":"1998","journal-title":"correlation analysis. Magn Reson Imaging"},{"key":"10.1016\/j.acra.2005.08.035_bib23","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1016\/j.mri.2004.01.035","article-title":"Controlling the false positive rate in fuzzy clustering using randomization","volume":"22","author":"Jahanian","year":"2004","journal-title":"Magn Reson Imaging"},{"key":"10.1016\/j.acra.2005.08.035_bib24","first-page":"28","article-title":"Computer and Robot Vision","volume":"1","author":"Haralick","year":"1992","journal-title":"Reading, MA"},{"key":"10.1016\/j.acra.2005.08.035_bib25","series-title":"Morphological Image Analysis","first-page":"173","author":"Soille","year":"1999"},{"key":"10.1016\/j.acra.2005.08.035_bib26","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1148\/radiology.211.1.r99ap38101","article-title":"Dynamic breast MR imaging","volume":"211","author":"Kuhl","year":"1999","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2005.08.035_bib27","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1002\/mrm.1910330408","article-title":"Pharmacokinetic mapping of the breast","volume":"33","author":"Hoffmann","year":"1995","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.acra.2005.08.035_bib28","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1259\/0007-1285-60-709-83","article-title":"Image nonuniformity in magnetic resonance imaging","volume":"60","author":"Condon","year":"1987","journal-title":"Br J Radiol"},{"key":"10.1016\/j.acra.2005.08.035_bib29","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1109\/42.511747","article-title":"Adaptive segmentation of MRI data","volume":"15","author":"Wells","year":"1996","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1016\/j.acra.2005.08.035_bib30","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1109\/42.585758","article-title":"Estimating the bias field of MR images","volume":"16","author":"Guillemaud","year":"1997","journal-title":"IEEE Trans Med Imaging"},{"key":"10.1016\/j.acra.2005.08.035_bib31","series-title":"PhD dissertation","article-title":"Analysis of Contrast-Enhanced Breast MRI","author":"Hayton","year":"1998"},{"key":"10.1016\/j.acra.2005.08.035_bib32","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1117\/12.387599","article-title":"Fractal discrimination of MRI breast masses using multiple segmentations","volume":"3979","author":"Penn","year":"2000","journal-title":"Proc SPIE Med Imaging 2000"}],"container-title":["Academic Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1076633205008032?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1076633205008032?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,4,11]],"date-time":"2020-04-11T23:15:25Z","timestamp":1586646925000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1076633205008032"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,1]]},"references-count":32,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2006,1]]}},"alternative-id":["S1076633205008032"],"URL":"https:\/\/doi.org\/10.1016\/j.acra.2005.08.035","relation":{},"ISSN":["1076-6332"],"issn-type":[{"value":"1076-6332","type":"print"}],"subject":[],"published":{"date-parts":[[2006,1]]}}}