{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T15:33:05Z","timestamp":1757777585803},"reference-count":26,"publisher":"Elsevier BV","issue":"12","license":[{"start":{"date-parts":[[2009,12,1]],"date-time":"2009-12-01T00:00:00Z","timestamp":1259625600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Academic Radiology"],"published-print":{"date-parts":[[2009,12]]},"DOI":"10.1016\/j.acra.2009.07.010","type":"journal-article","created":{"date-parts":[[2009,11,5]],"date-time":"2009-11-05T12:42:19Z","timestamp":1257424939000},"page":"1509-1517","source":"Crossref","is-referenced-by-count":6,"title":["Conspicuity of Microcalcifications on Digital Screening Mammograms Using Varying Degrees of Monitor Zooming"],"prefix":"10.1016","volume":"16","author":[{"given":"Tamara Miner","family":"Haygood","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elsa","family":"Arribas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick C.","family":"Brennan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E. Neely","family":"Atkinson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark","family":"Herndon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph","family":"Dieber","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William","family":"Geiser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lumarie","family":"Santiago","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chadwick M.","family":"Mills","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul","family":"Davis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Beatriz","family":"Adrada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Selin","family":"Carkaci","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tanya W.","family":"Stephens","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gary J.","family":"Whitman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.acra.2009.07.010_bib1","unstructured":"American College of Radiology. Practice guideline for determinants of image quality in digital mammography. Available at: http:\/\/www.acr.org\/SecondaryMainMenuCategories\/quality_safety\/guidelines\/breast\/image_quality_digital_mammo.aspx. Accessed August 27, 2008."},{"key":"10.1016\/j.acra.2009.07.010_bib2","doi-asserted-by":"crossref","first-page":"38","DOI":"10.2214\/AJR.05.1397","article-title":"Digital and screen-film mammography: comparison of image acquisition and interpretation times","volume":"187","author":"Berns","year":"2006","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2009.07.010_bib3","doi-asserted-by":"crossref","first-page":"216","DOI":"10.2214\/AJR.07.3608","article-title":"Timed efficiency of digital\u00a0and\u00a0film-screen screening mammographic interpretation","volume":"192","author":"Haygood","year":"2009","journal-title":"AJR Am\u00a0J Roentgenol"},{"key":"10.1016\/j.acra.2009.07.010_bib4","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"},{"key":"10.1016\/j.acra.2009.07.010_bib5","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1148\/radiol.2232010704","article-title":"Interpretation of digital mammograms: comparison of speed and accuracy of soft-copy versus printed-film display","volume":"223","author":"Pisano","year":"2002","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2009.07.010_bib6","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1016\/j.acra.2004.04.003","article-title":"Diagnostic accuracy of Fischer Senoscan digital mammography versus screen-film mammography in a diagnostic mammography population","volume":"11","author":"Cole","year":"2004","journal-title":"Acad Radiol"},{"key":"10.1016\/j.acra.2009.07.010_bib7","doi-asserted-by":"crossref","first-page":"671","DOI":"10.2214\/ajr.179.3.1790671","article-title":"Clinical comparison of full-field digital mammography and screen-film mammography for detection of breast cancer","volume":"179","author":"Lewin","year":"2002","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2009.07.010_bib8","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1148\/radiol.2293021171","article-title":"Population-based mammography screening: comparison of screen-film and full-field digital mammography with soft-copy reading\u2014Oslo I study","volume":"229","author":"Skaane","year":"2003","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2009.07.010_bib9","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1148\/radiol.2321031624","article-title":"Screen-film mammography versus full-field digital mammography with soft-copy reading: randomized trial in a\u00a0population-based screening program\u2014the Oslo II study","volume":"232","author":"Skaane","year":"2004","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2009.07.010_bib10","doi-asserted-by":"crossref","first-page":"2188","DOI":"10.1007\/s00330-002-1356-8","article-title":"Magnification mammography: a comparison of full-field digital mammography and screen-film mammography for the detection of simulated small masses and microcalcifications","volume":"12","author":"Hermann","year":"2002","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.acra.2009.07.010_bib11","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1148\/radiol.2461070200","article-title":"Diagnostic accuracy of digital versus film mammography: exploratory analysis of selected population subgroups in DMIST","volume":"246","author":"Pisano","year":"2008","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2009.07.010_bib12","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1148\/radiol.2443061478","article-title":"Randomized trial of screen-film versus full-field digital mammography with soft-copy reading in population-based screening program: follow-up and final results of Oslo II study","volume":"244","author":"Skaane","year":"2007","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2009.07.010_bib13","doi-asserted-by":"crossref","first-page":"860","DOI":"10.2214\/AJR.07.2303","article-title":"Full-field digital versus screen-film mammography: comparative accuracy in concurrent screening cohorts","volume":"189","author":"Del Turco","year":"2007","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2009.07.010_bib14","article-title":"Why does it take longer to read digital than film-screen screening mammograms? A partial explanation","author":"Haygood","year":"2009","journal-title":"J\u00a0Digit Imaging"},{"key":"10.1016\/j.acra.2009.07.010_bib15","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1007\/s10278-005-7666-z","article-title":"Differential use of image enhancement techniques by experienced and inexperienced observers","volume":"18","author":"Krupinski","year":"2005","journal-title":"J\u00a0Digit Imaging"},{"key":"10.1016\/j.acra.2009.07.010_bib16","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1148\/radiol.2471070418","article-title":"Accuracy of soft-copy digital mammography versus that of screen-film mammography according to digital manufacturer: ACRIN DMIST retrospective multireader study","volume":"247","author":"Hendrick","year":"2008","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2009.07.010_bib17","doi-asserted-by":"crossref","first-page":"47","DOI":"10.2214\/AJR.05.0187","article-title":"Comparison of calcification specificity in digital mammography using soft-copy display versus screen-film mammography","volume":"187","author":"Kim","year":"2006","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2009.07.010_bib18","doi-asserted-by":"crossref","first-page":"917","DOI":"10.2214\/ajr.179.4.1790917","article-title":"Time course of perception\u00a0and decision making during mammographic interpretation","volume":"179","author":"Nodine","year":"2002","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2009.07.010_bib19","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/0720-048X(93)90015-F","article-title":"Chest \u201cgestalt\u201d and detectability of lung lesions","volume":"16","author":"Oestmann","year":"1993","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.acra.2009.07.010_bib20","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1016\/j.acra.2008.01.023","article-title":"Using gaze-tracking data\u00a0and\u00a0mixture distribution analysis to support a holistic model for the\u00a0detection of cancers on mammograms","volume":"15","author":"Kundel","year":"2008","journal-title":"Acad Radiol"},{"key":"10.1016\/j.acra.2009.07.010_bib21","doi-asserted-by":"crossref","first-page":"1492","DOI":"10.2214\/AJR.04.1713","article-title":"Full-field digital mammography on LCD versus CRT monitors","volume":"187","author":"Zuley","year":"2006","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2009.07.010_bib22","doi-asserted-by":"crossref","first-page":"214","DOI":"10.3348\/kjr.2005.6.4.214","article-title":"Screen-film mammography and soft-copy full-field digital mammography: comparison in the patients with microcalcifications","volume":"6","author":"Kim","year":"2005","journal-title":"Korean J Radiol"},{"key":"10.1016\/j.acra.2009.07.010_bib23","doi-asserted-by":"crossref","first-page":"1252","DOI":"10.1016\/j.acra.2007.06.016","article-title":"A review of research into the development of radiologic expertise: Implications for computer-based training","volume":"14","author":"Taylor","year":"2007","journal-title":"Acad Radiol"},{"key":"10.1016\/j.acra.2009.07.010_bib24","doi-asserted-by":"crossref","first-page":"830","DOI":"10.1016\/j.acra.2005.03.068","article-title":"Effects of lesion conspicuity\u00a0on visual search in mammogram reading","volume":"12","author":"Mello-Thoms","year":"2005","journal-title":"Acad Radiol"},{"key":"10.1016\/j.acra.2009.07.010_bib25","doi-asserted-by":"crossref","first-page":"4464","DOI":"10.1118\/1.2977600","article-title":"The effect of breast compression on mass conspicuity in digital mammography","volume":"35","author":"Saunders","year":"2008","journal-title":"Med Phys"},{"key":"10.1016\/j.acra.2009.07.010_bib26","doi-asserted-by":"crossref","first-page":"1554","DOI":"10.1016\/j.acra.2008.07.018","article-title":"Validation and statistical power comparison of methods for analyzing free-response observer performance studies","volume":"15","author":"Chakraborty","year":"2008","journal-title":"Acad Radiol"}],"container-title":["Academic Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1076633209004085?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1076633209004085?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,12,15]],"date-time":"2018-12-15T15:21:04Z","timestamp":1544887264000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1076633209004085"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,12]]},"references-count":26,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2009,12]]}},"alternative-id":["S1076633209004085"],"URL":"https:\/\/doi.org\/10.1016\/j.acra.2009.07.010","relation":{},"ISSN":["1076-6332"],"issn-type":[{"value":"1076-6332","type":"print"}],"subject":[],"published":{"date-parts":[[2009,12]]}}}