{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,5,12]],"date-time":"2022-05-12T18:26:49Z","timestamp":1652380009269},"reference-count":23,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2011,2,1]],"date-time":"2011-02-01T00:00:00Z","timestamp":1296518400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Academic Radiology"],"published-print":{"date-parts":[[2011,2]]},"DOI":"10.1016\/j.acra.2010.09.014","type":"journal-article","created":{"date-parts":[[2010,11,14]],"date-time":"2010-11-14T09:28:22Z","timestamp":1289726902000},"page":"205-211","source":"Crossref","is-referenced-by-count":4,"title":["Patient Size Compensated Automatic Tube Current Modulation in Multi-detector Row CT of the Abdomen and Pelvis"],"prefix":"10.1016","volume":"18","author":[{"given":"Jianhai","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Unni K.","family":"Udayasankar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiangyang","family":"Tang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas L.","family":"Toth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William C.","family":"Small","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mannudeep K.","family":"Kalra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.acra.2010.09.014_bib1","doi-asserted-by":"crossref","first-page":"331","DOI":"10.2214\/ajr.181.2.1810331","article-title":"Dose reduction in multidetector CT using attenuation-based online tube current modulation","volume":"181","author":"Tack","year":"2003","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2010.09.014_bib2","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1148\/radiol.2363041220","article-title":"Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation","volume":"237","author":"Mulkens","year":"2005","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2010.09.014_bib3","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1148\/radiol.2351041751","article-title":"Automatic exposure control techniques for individual dose adaptation","volume":"235","author":"Rizzo","year":"2005","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2010.09.014_bib4","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1055\/s-2004-813183","article-title":"[Automatic exposure control to reduce the dose in subsecond multislice spiral CT: phantom measurements and clinical results]","volume":"176","author":"Greess","year":"2004","journal-title":"Rofo"},{"key":"10.1016\/j.acra.2010.09.014_bib5","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1148\/radiol.2303021726","article-title":"Strategies for CT radiation dose optimization","volume":"230","author":"Kalra","year":"2004","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2010.09.014_bib6","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1148\/radiol.2333031150","article-title":"Techniques and applications of automatic tube current modulation for CT","volume":"233","author":"Kalra","year":"2004","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2010.09.014_bib7","first-page":"2221","article-title":"Optimization of Z-axis automatic exposure control for multidetector row CT evaluation of neck and comparison with fixed tube current technique for image quality and radiation dose","volume":"27","author":"Namasivayam","year":"2006","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.acra.2010.09.014_bib8","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1148\/radiol.2331031505","article-title":"Sixteen-detector row CT of abdomen and pelvis: study for optimization of Z-axis modulation technique performed in 153 patients","volume":"233","author":"Kalra","year":"2004","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2010.09.014_bib9","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1148\/radiol.2371041227","article-title":"Chest CT performed with z-axis modulation: scanning protocol and radiation dose","volume":"237","author":"Kalra","year":"2005","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2010.09.014_bib10","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1148\/radiol.2352040331","article-title":"Detection of urinary tract stones at low-radiation-dose CT with z-axis automatic tube current modulation: phantom and clinical studies","volume":"235","author":"Kalra","year":"2005","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2010.09.014_bib11","doi-asserted-by":"crossref","first-page":"234","DOI":"10.3348\/kjr.2003.4.4.234","article-title":"Correlation of patient weight and cross-sectional dimensions with subjective image quality at standard dose abdominal CT","volume":"4","author":"Kalra","year":"2003","journal-title":"Korean J Radiol"},{"key":"10.1016\/j.acra.2010.09.014_bib12","doi-asserted-by":"crossref","first-page":"W100","DOI":"10.2214\/AJR.07.2891","article-title":"Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: phantom study","volume":"190","author":"Schindera","year":"2008","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2010.09.014_bib13","doi-asserted-by":"crossref","first-page":"3889","DOI":"10.1088\/0031-9155\/50\/16\/016","article-title":"A three-dimensional weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT under a circular source trajectory","volume":"50","author":"Tang","year":"2005","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.acra.2010.09.014_bib14","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1088\/0031-9155\/51\/4\/007","article-title":"A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning","volume":"51","author":"Tang","year":"2006","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.acra.2010.09.014_bib15","doi-asserted-by":"crossref","first-page":"3093","DOI":"10.1118\/1.2748113","article-title":"The influence of patient centering on CT dose and image noise","volume":"34","author":"Toth","year":"2007","journal-title":"Med Phys"},{"key":"10.1016\/j.acra.2010.09.014_bib16","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1118\/1.598948","article-title":"Calculation of effective dose","volume":"27","author":"McCollough","year":"2000","journal-title":"Med Phys"},{"key":"10.1016\/j.acra.2010.09.014_bib17","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"Landis","year":"1977","journal-title":"Biometrics"},{"key":"10.1016\/j.acra.2010.09.014_bib18","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1007\/s003300050674","article-title":"Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers","volume":"9","author":"Kalender","year":"1999","journal-title":"Eur Radiol"},{"key":"10.1016\/j.acra.2010.09.014_bib19","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1067\/j.cpradiol.2005.06.002","article-title":"Computed tomography radiation dose optimization: scanning protocols and clinical applications of automatic exposure control","volume":"345","author":"Kalra","year":"2005","journal-title":"Curr Probl Diagn Radiol"},{"key":"10.1016\/j.acra.2010.09.014_bib20","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1093\/rpd\/ncm384","article-title":"Comparison between 3-D and z-axis automatic tube current modulation technique in multidetector-row CT","volume":"128","author":"Matsubara","year":"2008","journal-title":"Radiat Prot Dosimetry"},{"key":"10.1016\/j.acra.2010.09.014_bib21","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1148\/rg.262055138","article-title":"CT dose reduction and dose management tools: overview of available options","volume":"26","author":"McCollough","year":"2006","journal-title":"Radiographics"},{"key":"10.1016\/j.acra.2010.09.014_bib22","doi-asserted-by":"crossref","first-page":"673","DOI":"10.2214\/AJR.04.1513","article-title":"Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis","volume":"186","author":"Rizzo","year":"2006","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2010.09.014_bib23","doi-asserted-by":"crossref","first-page":"547","DOI":"10.2214\/AJR.06.0370","article-title":"Automatic patient centering for MDCT: effect on radiation dose","volume":"188","author":"Li","year":"2007","journal-title":"AJR Am J Roentgenol"}],"container-title":["Academic Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1076633210005234?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1076633210005234?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,6,6]],"date-time":"2019-06-06T08:27:52Z","timestamp":1559809672000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1076633210005234"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,2]]},"references-count":23,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2011,2]]}},"alternative-id":["S1076633210005234"],"URL":"https:\/\/doi.org\/10.1016\/j.acra.2010.09.014","relation":{},"ISSN":["1076-6332"],"issn-type":[{"value":"1076-6332","type":"print"}],"subject":[],"published":{"date-parts":[[2011,2]]}}}