{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T01:55:27Z","timestamp":1781661327748,"version":"3.54.5"},"reference-count":25,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2016,3,1]],"date-time":"2016-03-01T00:00:00Z","timestamp":1456790400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81201092"],"award-info":[{"award-number":["81201092"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Beijing Health System High Level Health Technical Personnel Training Plan","award":["2013-3-068"],"award-info":[{"award-number":["2013-3-068"]}]}],"content-domain":{"domain":["academicradiology.org","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Academic Radiology"],"published-print":{"date-parts":[[2016,3]]},"DOI":"10.1016\/j.acra.2015.11.004","type":"journal-article","created":{"date-parts":[[2016,1,6]],"date-time":"2016-01-06T08:30:26Z","timestamp":1452069026000},"page":"337-343","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"title":["Optimal Adaptive Statistical Iterative Reconstruction Percentage in Dual-energy Monochromatic CT Portal Venography"],"prefix":"10.1016","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1274-5179","authenticated-orcid":false,"given":"Liqin","family":"Zhao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Winklhofer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhenghan","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keyang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wen","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.acra.2015.11.004_bib0010","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1148\/rg.331125037","article-title":"Multidetector CT anatomy of drainage routes of gastric varices: a pictorial review","volume":"33","author":"Kiyosue","year":"2013","journal-title":"Radiographics"},{"key":"10.1016\/j.acra.2015.11.004_bib0015","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00261-009-9506-y","article-title":"Evaluation of entire gastric fundic and esophageal varices secondary to posthepatitic cirrhosis: portal venography using 64-row MDCT","volume":"35","author":"Chen","year":"2010","journal-title":"Abdom Imaging"},{"key":"10.1016\/j.acra.2015.11.004_bib0020","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1111\/j.1440-1673.2007.01903.x","article-title":"Multidetector CT portal venography in evaluation of portosystemic collateral vessels","volume":"52","author":"Agarwal","year":"2008","journal-title":"J Med Imaging Radiat Oncol"},{"key":"10.1016\/j.acra.2015.11.004_bib0025","first-page":"98","article-title":"Efficacy of CT angiography for preoperative vascular mapping in adult to adult living related liver transplant donors","volume":"94","author":"Apisarnthanarak","year":"2011","journal-title":"J Med Assoc Thai"},{"key":"10.1016\/j.acra.2015.11.004_bib0030","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1148\/radiol.13121901","article-title":"Coronary artery imaging with single-source rapid kilovolt peak-switching dual-energy CT","volume":"268","author":"Scheske","year":"2013","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2015.11.004_bib0035","doi-asserted-by":"crossref","first-page":"686","DOI":"10.2214\/AJR.09.3681","article-title":"Partial thrombosis of gastric varices after balloon-occluded retrograde transvenous obliteration: CT findings and endoscopic correlation","volume":"196","author":"Takaji","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2015.11.004_bib0040","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1148\/radiol.13122462","article-title":"Contrast medium-induced nephrotoxicity risk assessment in adult inpatients: a comparison of serum creatinine level- and estimated glomerular filtration rate-based screening methods","volume":"269","author":"Davenport","year":"2013","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2015.11.004_bib0045","doi-asserted-by":"crossref","first-page":"e387","DOI":"10.1016\/j.ejrad.2013.04.029","article-title":"Contrast induced nephropathy in patients undergoing intravenous (IV) contrast enhanced computed tomography (CECT) and the relationship with risk factors: a meta-analysis","volume":"82","author":"Moos","year":"2013","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.acra.2015.11.004_bib0050","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1177\/0284185113488576","article-title":"Impact of adaptive iterative dose reduction (AIDR) 3D on low-dose abdominal CT: comparison with routine-dose CT using filtered back projection","volume":"54","author":"Matsuki","year":"2013","journal-title":"Acta Radiol"},{"key":"10.1016\/j.acra.2015.11.004_bib0055","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1258\/ar.2011.100500","article-title":"The optimal contrast media policy in CT of the liver. Part II: clinical protocols","volume":"52","author":"Rengo","year":"2011","journal-title":"Acta Radiol"},{"key":"10.1016\/j.acra.2015.11.004_bib0060","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1097\/RCT.0b013e31827cd656","article-title":"Optimal contrast of computed tomography portal venography using dual-energy computed tomography","volume":"37","author":"Wang","year":"2013","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.acra.2015.11.004_bib0065","doi-asserted-by":"crossref","first-page":"S64","DOI":"10.2214\/AJR.12.9196","article-title":"Dual-energy CT applications in the abdomen","volume":"199","author":"Heye","year":"2012","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2015.11.004_bib0070","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1148\/radiol.11100978","article-title":"Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT","volume":"259","author":"Matsumoto","year":"2011","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2015.11.004_bib0075","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1007\/s00330-012-2624-x","article-title":"Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose","volume":"23","author":"Pinho","year":"2013","journal-title":"Eur Radiol"},{"key":"10.1016\/j.acra.2015.11.004_bib0080","doi-asserted-by":"crossref","first-page":"47","DOI":"10.2214\/AJR.09.2592","article-title":"Dual-energy and low-kVp CT in the abdomen","volume":"193","author":"Yeh","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2015.11.004_bib0085","doi-asserted-by":"crossref","first-page":"713","DOI":"10.2214\/AJR.09.2989","article-title":"Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients","volume":"195","author":"Sagara","year":"2010","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2015.11.004_bib0090","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1097\/RLI.ob013e3181dzfeec","article-title":"Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique","volume":"45","author":"Prakash","year":"2010","journal-title":"Invest Radiol"},{"key":"10.1016\/j.acra.2015.11.004_bib0095","doi-asserted-by":"crossref","first-page":"W336","DOI":"10.2214\/AJR.10.4573","article-title":"Impact of adaptive statistical iterative reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: a qualitative and quantitative analysis","volume":"196","author":"Cornfeld","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2015.11.004_bib0100","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1148\/radiol.12110268","article-title":"Radiation dose reduction with hybrid iterative reconstruction for pediatric CT","volume":"263","author":"Singh","year":"2012","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2015.11.004_bib0105","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1097\/RLI.0b013e318240a874","article-title":"Virtual monochromatic spectral imaging for the evaluation of hypovascular hepatic metastases: the optimal monochromatic level with fast kilovoltage switching dual-energy computed tomography","volume":"47","author":"Yamada","year":"2012","journal-title":"Invest Radiol"},{"key":"10.1016\/j.acra.2015.11.004_bib0110","series-title":"Interpretation and uses of medical statistics","first-page":"p410","author":"Daly","year":"2007"},{"key":"10.1016\/j.acra.2015.11.004_bib0115","series-title":"Measurement in physical education","author":"Meyers","year":"1962"},{"key":"10.1016\/j.acra.2015.11.004_bib0120","doi-asserted-by":"crossref","first-page":"1677","DOI":"10.1016\/j.ejrad.2011.02.063","article-title":"Improving image quality in portal venography with spectral CT imaging","volume":"81","author":"Zhao","year":"2012","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.acra.2015.11.004_bib0125","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1016\/j.jvir.2012.04.012","article-title":"Indirect computed tomography venography of the lower extremities using single-source dual-energy computed tomography: advantage of low-kiloelectron volt monochromatic images","volume":"23","author":"Kulkarni","year":"2012","journal-title":"J Vasc Interv Radiol"},{"key":"10.1016\/j.acra.2015.11.004_bib0130","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.jcct.2013.01.004","article-title":"First experience with monochromatic coronary computed tomography angiography from a 64-slice CT scanner with gemstone spectral imaging (GSI)","volume":"7","author":"Fuchs","year":"2013","journal-title":"J Cardiovasc Comput Tomogr"}],"container-title":["Academic Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1076633215005164?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1076633215005164?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,16]],"date-time":"2018-09-16T06:22:03Z","timestamp":1537078923000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1076633215005164"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,3]]},"references-count":25,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2016,3]]}},"alternative-id":["S1076633215005164"],"URL":"https:\/\/doi.org\/10.1016\/j.acra.2015.11.004","relation":{},"ISSN":["1076-6332"],"issn-type":[{"value":"1076-6332","type":"print"}],"subject":[],"published":{"date-parts":[[2016,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Optimal Adaptive Statistical Iterative Reconstruction Percentage in Dual-energy Monochromatic CT Portal Venography","name":"articletitle","label":"Article Title"},{"value":"Academic Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.acra.2015.11.004","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}