{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T09:12:27Z","timestamp":1782983547994,"version":"3.54.5"},"reference-count":26,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2019,4,1]],"date-time":"2019-04-01T00:00:00Z","timestamp":1554076800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["academicradiology.org","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Academic Radiology"],"published-print":{"date-parts":[[2019,4]]},"DOI":"10.1016\/j.acra.2018.05.027","type":"journal-article","created":{"date-parts":[[2018,8,17]],"date-time":"2018-08-17T10:47:46Z","timestamp":1534502866000},"page":"480-488","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"title":["Reduced Contrast Volume and Radiation Dose During Computed Tomography of the Pancreas"],"prefix":"10.1016","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5394-9699","authenticated-orcid":false,"given":"Charbel","family":"Saade","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jad","family":"Chokr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3361-5880","authenticated-orcid":false,"given":"Lena","family":"Naffaa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Walid","family":"Faraj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali","family":"Shamseddine","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deborah","family":"Mukherji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Skye El","family":"Sayegh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rita","family":"Assi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7528-6854","authenticated-orcid":false,"given":"Ali","family":"Haydar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.acra.2018.05.027_bib0001","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1148\/radiology.220.1.r01jl1897","article-title":"Multi-detector row helical CT of the pancreas: effect of contrast-enhanced multiphasic imaging on enhancement of the pancreas, peripancreatic vasculature, and pancreatic adenocarcinoma 1","volume":"220","author":"McNulty","year":"2001","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2018.05.027_bib0002","doi-asserted-by":"crossref","first-page":"301","DOI":"10.2214\/AJR.11.7907","article-title":"Pancreatic imaging mimics: part 1, imaging mimics of pancreatic adenocarcinoma","volume":"199","author":"Coakley","year":"2012","journal-title":"Am J Roentgenol"},{"key":"10.1016\/j.acra.2018.05.027_bib0003","doi-asserted-by":"crossref","first-page":"753","DOI":"10.7326\/0003-4819-141-10-200411160-00006","article-title":"Comparison of endoscopic ultrasonography and multidetector computed tomography for detecting and staging pancreatic cancer","volume":"141","author":"DeWitt","year":"2004","journal-title":"Ann Intern Med"},{"key":"10.1016\/j.acra.2018.05.027_bib0004","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1111\/j.1572-0241.2004.04087.x","article-title":"Preoperative staging and tumor resectability assessment of pancreatic cancer: prospective study comparing endoscopic ultrasonography, helical computed tomography, magnetic resonance imaging, and angiography","volume":"99","author":"Soriano","year":"2004","journal-title":"Am J Gastroenterol"},{"key":"10.1016\/j.acra.2018.05.027_bib0005","doi-asserted-by":"crossref","first-page":"890","DOI":"10.1245\/ASO.2003.03.555","article-title":"Comparison of linear array endoscopic ultrasound and helical computed tomography for thestaging of periampullary malignancies","volume":"10","author":"Rivadeneira","year":"2003","journal-title":"Ann Surg Oncol"},{"key":"10.1016\/j.acra.2018.05.027_bib0006","series-title":"Imaging of the pancreas. multidisciplinary teaching atlas of the pancreas","first-page":"91","author":"Casillas","year":"2016"},{"key":"10.1016\/j.acra.2018.05.027_bib0007","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.gtc.2015.10.010","article-title":"Imaging of the pancreas","volume":"45","author":"Xu","year":"2016","journal-title":"Gastroenterol Clin N Am"},{"key":"10.1016\/j.acra.2018.05.027_bib0008","first-page":"1","article-title":"Multidetector CT of pancreatic ductal adenocarcinoma: effect of tube voltage and iodine load on tumour conspicuity and image quality","author":"Loizou","year":"2016","journal-title":"Eur Radiol"},{"key":"10.1016\/j.acra.2018.05.027_bib0009","article-title":"Contrast medium usage reduction in abdominal computed tomography by using high-iodinated concentration contrast medium","author":"Suwannasri","year":"2016","journal-title":"J Phys: Conf Ser"},{"key":"10.1016\/j.acra.2018.05.027_bib0010","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1148\/radiology.195.2.7724752","article-title":"Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement","volume":"195","author":"Heiken","year":"1995","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2018.05.027_bib0011","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1148\/radiology.216.3.r00se26718","article-title":"Abdominal helical CT: evaluation of optimal doses of intravenous contrast material\u2014a prospective randomized study 1","volume":"216","author":"Yamashita","year":"2000","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2018.05.027_bib0012","article-title":"Model-based iterative reconstruction and adaptive statistical iterative reconstruction: dose-reduced CT for detecting pancreatic calcification","volume":"5","author":"Yasaka","year":"2016","journal-title":"Acta Radiol Open"},{"key":"10.1016\/j.acra.2018.05.027_bib0013","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1148\/radiol.13121409","article-title":"Split-bolus spectral multidetector CT of the pancreas: assessment of radiation dose and tumor conspicuity","volume":"269","author":"Brook","year":"2013","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2018.05.027_bib0014","doi-asserted-by":"crossref","first-page":"2052","DOI":"10.1016\/j.ejrad.2015.07.020","article-title":"Dual-energy CT of the pancreas: improved carcinoma-to-pancreas contrast with a noise-optimized monoenergetic reconstruction algorithm","volume":"84","author":"Frellesen","year":"2015","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.acra.2018.05.027_bib0015","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1159\/000055871","article-title":"Imaging pancreatic cancer: the role of multidetector CT with three-dimensional CT angiography","volume":"1","author":"Fishman","year":"2001","journal-title":"Pancreatology"},{"key":"10.1016\/j.acra.2018.05.027_bib0016","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1097\/RLI.0b013e3181727505","article-title":"Contrast injection protocols for coronary computed tomography angiography using a 64-detector scanner: comparison between patient weight-adjusted- and fixed iodine-dose protocols","volume":"43","author":"Nakaura","year":"2008","journal-title":"Investig Radiol"},{"key":"10.1016\/j.acra.2018.05.027_bib0017","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1148\/radiol.2412051107","article-title":"Multidetector CT of pancreas: effects of contrast material flow rate and individualized scan delay on enhancement of pancreas and tumor contrast","volume":"241","author":"Schueller","year":"2006","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2018.05.027_bib0018","doi-asserted-by":"crossref","first-page":"995","DOI":"10.1148\/radiol.2483071964","article-title":"Converting dose-length product to effective dose at CT","volume":"248","author":"Huda","year":"2008","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2018.05.027_bib0019","unstructured":"Boone J, Strauss K, Cody D. Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations: AAPM report no. 204. American Association of Physicists in Medicine website. 2013."},{"key":"10.1016\/j.acra.2018.05.027_bib0020","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1259\/bjr\/35012658","article-title":"Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluation","volume":"80","author":"Bath","year":"2007","journal-title":"Br J Radiol."},{"key":"10.1016\/j.acra.2018.05.027_bib0021","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1186\/s13027-016-0105-6","article-title":"Multidetector computer tomography in the pancreatic adenocarcinoma assessment: an update","volume":"11","author":"Granata","year":"2016","journal-title":"Infect Agents Cancer"},{"key":"10.1016\/j.acra.2018.05.027_bib0022","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1097\/RCT.0000000000000268","article-title":"High-pitch dual-source computed tomography renal angiography comparison with conventional low-pitch computed tomography angiography: image quality, contrast medium volume, and radiation dose","volume":"39","author":"Pang","year":"2015","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.acra.2018.05.027_bib0023","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1097\/RCT.0b013e31829e02b9","article-title":"Caudocranial scan direction and patient-specific injection protocols optimize ECG-gated and non-gated thoracic CTA","volume":"37","author":"Saade","year":"2013","journal-title":"J Comput Assist Tomogr."},{"key":"10.1016\/j.acra.2018.05.027_bib0024","doi-asserted-by":"crossref","DOI":"10.5152\/dir.2015.15219","article-title":"Contrast medium administration and image acquisition parameters in renal CT angiography: what radiologists need to know","author":"Saade","year":"2016","journal-title":"Diagn Interv Radiol."},{"key":"10.1016\/j.acra.2018.05.027_bib0025","doi-asserted-by":"crossref","first-page":"96","DOI":"10.2214\/AJR.11.7450","article-title":"CT angiography of the renal arteries: comparison of lower-tube-voltage CTA with moderate-concentration iodinated contrast material and conventional CTA","volume":"199","author":"Cho","year":"2012","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.acra.2018.05.027_bib0026","doi-asserted-by":"crossref","first-page":"687","DOI":"10.2214\/AJR.15.14518","article-title":"Impact of knowledge-based iterative model reconstruction in abdominal dynamic ct with low tube voltage and low contrast dose","author":"Iyama","year":"2016","journal-title":"AJR Am J Roentgenol"}],"container-title":["Academic Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S107663321830312X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S107663321830312X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,11,27]],"date-time":"2019-11-27T22:56:04Z","timestamp":1574895364000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S107663321830312X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4]]},"references-count":26,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,4]]}},"alternative-id":["S107663321830312X"],"URL":"https:\/\/doi.org\/10.1016\/j.acra.2018.05.027","relation":{},"ISSN":["1076-6332"],"issn-type":[{"value":"1076-6332","type":"print"}],"subject":[],"published":{"date-parts":[[2019,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Reduced Contrast Volume and Radiation Dose During Computed Tomography of the Pancreas","name":"articletitle","label":"Article Title"},{"value":"Academic Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.acra.2018.05.027","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}