{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,22]],"date-time":"2026-02-22T00:42:22Z","timestamp":1771720942198,"version":"3.50.1"},"reference-count":21,"publisher":"Elsevier BV","issue":"11","license":[{"start":{"date-parts":[[2023,11,1]],"date-time":"2023-11-01T00:00:00Z","timestamp":1698796800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,11,1]],"date-time":"2023-11-01T00:00:00Z","timestamp":1698796800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100016724","name":"Postgraduate Institute of Medical Education and Research, Chandigarh","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100016724","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["academicradiology.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Academic Radiology"],"published-print":{"date-parts":[[2023,11]]},"DOI":"10.1016\/j.acra.2023.01.029","type":"journal-article","created":{"date-parts":[[2023,3,16]],"date-time":"2023-03-16T01:52:11Z","timestamp":1678931531000},"page":"2557-2565","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Impact of Radial Percentage K-Space Filling and Signal Averaging on Native Lung MRI Image Quality in 3D Radial UTE Acquisition: A Pilot Study"],"prefix":"10.1016","volume":"30","author":[{"given":"Kushaljit Singh","family":"Sodhi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4630-5742","authenticated-orcid":false,"given":"Anmol","family":"Bhatia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pratyaksha","family":"Rana","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph L.","family":"Mathew","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.acra.2023.01.029_bib0001","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1007\/s13244-011-0142-z","article-title":"MRI of the lung (3\/3)\u2014current applications and future perspectives","volume":"3","author":"Biederer","year":"2012","journal-title":"Insights Imaging"},{"key":"10.1016\/j.acra.2023.01.029_bib0002","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.ejrad.2018.12.021","article-title":"Evaluation of 3\u2009T lung magnetic resonance imaging in children with allergic bronchopulmonary aspergillosis: pilot study","volume":"111","author":"Sodhi","year":"2019","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.acra.2023.01.029_bib0003","doi-asserted-by":"crossref","first-page":"70","DOI":"10.3109\/10428194.2015.1041389","article-title":"Rapid lung MRI\u2014paradigm shift in evaluation of febrile neutropenia in children with leukemia: a pilot study","volume":"57","author":"Sodhi","year":"2016","journal-title":"Leuk Lymphoma"},{"key":"10.1016\/j.acra.2023.01.029_bib0004","doi-asserted-by":"crossref","first-page":"982","DOI":"10.2214\/AJR.18.20928","article-title":"Prospective comparison of MRI and contrast-enhanced MDCT for evaluation of pediatric pulmonary hydatid disease: added diagnostic value of MRI","volume":"212","author":"Sodhi","year":"2019","journal-title":"AJR"},{"key":"10.1016\/j.acra.2023.01.029_bib0005","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1007\/s00247-019-04523-0","article-title":"Diagnostic accuracy of 3-T lung magnetic resonance imaging in human immunodeficiency virus-positive children","volume":"50","author":"Rana","year":"2020","journal-title":"Pediatr Radiol"},{"key":"10.1016\/j.acra.2023.01.029_bib0006","doi-asserted-by":"crossref","first-page":"1196","DOI":"10.1002\/jmri.25082","article-title":"Rapid lung MRI in children with pulmonary infections: time to change our diagnostic algorithms","volume":"43","author":"Sodhi","year":"2016","journal-title":"J Magn Reson Imaging"},{"key":"10.1016\/j.acra.2023.01.029_bib0007","doi-asserted-by":"crossref","first-page":"1542","DOI":"10.1002\/nbm.3156","article-title":"Advances in functional and structural imaging of the human lung using proton MRI","volume":"27","author":"Miller","year":"2014","journal-title":"NMR Biomed"},{"key":"10.1016\/j.acra.2023.01.029_bib0008","doi-asserted-by":"crossref","first-page":"1656","DOI":"10.1002\/jmri.25309","article-title":"Morphological and quantitative evaluation of emphysema in chronic obstructive pulmonary disease patients: a comparative study of MRI with CT","volume":"44","author":"Roach","year":"2016","journal-title":"J Magn Reson Imaging"},{"key":"10.1016\/j.acra.2023.01.029_bib0009","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1055\/a-0715-2246","article-title":"Outracing lung signal decay\u2014potential of ultrashort echo time MRI","volume":"191","author":"Wielp\u00fctz","year":"2019","journal-title":"Rofo"},{"key":"10.1016\/j.acra.2023.01.029_bib0010","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1002\/jmri.25008","article-title":"Pulmonary high resolution ultrashort TE MR imaging: comparison with thin-section standard- and low-dose computed tomography for the assessment of pulmonary parenchyma diseases","volume":"43","author":"Ohno","year":"2016","journal-title":"J Magn Reson Imaging"},{"key":"10.1016\/j.acra.2023.01.029_bib0011","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1002\/jmri.25394","article-title":"Pulmonary MRI of neonates in the intensive care unit using 3D ultrashort echo time and a small footprint MRI system","volume":"45","author":"Hahn","year":"2017","journal-title":"J Magn Reson Imaging"},{"key":"10.1016\/j.acra.2023.01.029_bib0012","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1007\/s10334-014-0459-y","article-title":"Free-breathing, zero-TE MR lung imaging","volume":"28","author":"Gibiino","year":"2014","journal-title":"Magn Reson Mater Phys Biol Med"},{"key":"10.1016\/j.acra.2023.01.029_bib0013","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1007\/s00247-021-05090-z","article-title":"Practical protocol for lung magnetic resonance imaging and common clinical indications","volume":"52","author":"Sodhi","year":"2022","journal-title":"Pediatr Radiol"},{"key":"10.1016\/j.acra.2023.01.029_bib0014","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1002\/jmri.23798","article-title":"DC-gated high resolution three dimensional lung imaging during free-breathing","volume":"37","author":"Weick","year":"2013","journal-title":"J Magn Reson Imaging"},{"key":"10.1016\/j.acra.2023.01.029_bib0015","doi-asserted-by":"crossref","first-page":"1241","DOI":"10.1002\/mrm.24570","article-title":"Optimized 3D ultrashort echo time pulmonary MRI","volume":"70","author":"Johnson","year":"2013","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.acra.2023.01.029_bib0016","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1148\/radiol.15141655","article-title":"Quiet submillimeter MR imaging of the lung is feasible with a PETRA sequence at 1.5T","volume":"276","author":"Dournes","year":"2015","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2023.01.029_bib0017","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1148\/radiology.179.3.2027991","article-title":"Lung parenchyma: projection reconstruction MR imaging","volume":"179","author":"Bergin","year":"1991","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2023.01.029_bib0018","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1002\/jmri.10113","article-title":"Short echo time MR spectroscopic imaging of the lung parenchyma","volume":"15","author":"Gold","year":"2002","journal-title":"J Magn Reson Imaging"},{"key":"10.1016\/j.acra.2023.01.029_bib0019","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1148\/radiol.2020201138","article-title":"Expanding applications of pulmonary MRI in the clinical evaluation of lung disorders: Fleischner society position paper","volume":"297","author":"Hatabu","year":"2020","journal-title":"Radiology"},{"key":"10.1016\/j.acra.2023.01.029_bib0020","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1002\/mrm.20796","article-title":"Design and analysis of a practical 3D cones trajectory","volume":"55","author":"Gurney","year":"2006","journal-title":"Magn Reson Med"},{"key":"10.1016\/j.acra.2023.01.029_bib0021","doi-asserted-by":"crossref","first-page":"708.e9","DOI":"10.1016\/j.crad.2021.05.015","article-title":"Clinical application of ultrashort echo-time MRI for lung pathologies in children","volume":"76","author":"Geiger","year":"2021","journal-title":"Clin Radiol"}],"container-title":["Academic Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1076633223000454?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1076633223000454?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T09:00:51Z","timestamp":1761037251000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1076633223000454"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11]]},"references-count":21,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2023,11]]}},"alternative-id":["S1076633223000454"],"URL":"https:\/\/doi.org\/10.1016\/j.acra.2023.01.029","relation":{},"ISSN":["1076-6332"],"issn-type":[{"value":"1076-6332","type":"print"}],"subject":[],"published":{"date-parts":[[2023,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Impact of Radial Percentage K-Space Filling and Signal Averaging on Native Lung MRI Image Quality in 3D Radial UTE Acquisition: A Pilot Study","name":"articletitle","label":"Article Title"},{"value":"Academic Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.acra.2023.01.029","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}