{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T13:05:10Z","timestamp":1793019910313,"version":"4.5.0"},"reference-count":50,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2022,4,1]],"date-time":"2022-04-01T00:00:00Z","timestamp":1648771200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,4,1]],"date-time":"2022-04-01T00:00:00Z","timestamp":1648771200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["U1804251"],"award-info":[{"award-number":["U1804251"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100012149","name":"National Key Scientific Instrument and Equipment Development Projects of China","doi-asserted-by":"publisher","award":["2018YFC1106703"],"award-info":[{"award-number":["2018YFC1106703"]}],"id":[{"id":"10.13039\/501100012149","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100012166","name":"National Key Research and Development Program of China","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Acta Biomaterialia"],"published-print":{"date-parts":[[2022,4]]},"DOI":"10.1016\/j.actbio.2022.01.045","type":"journal-article","created":{"date-parts":[[2022,1,24]],"date-time":"2022-01-24T12:17:56Z","timestamp":1643026676000},"page":"402-412","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":84,"special_numbering":"C","title":["A biodegradable magnesium alloy vascular stent structure: Design, optimisation and evaluation"],"prefix":"10.1016","volume":"142","author":[{"given":"Yafei","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhenquan","family":"Shen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fulong","family":"Miao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianfeng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yufeng","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shijie","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7402-9979","authenticated-orcid":false,"given":"Yufeng","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5892-4164","authenticated-orcid":false,"given":"Shaokang","family":"Guan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"5","key":"10.1016\/j.actbio.2022.01.045_bib0001","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1038\/s41569-018-0124-7","article-title":"Fully bioresorbable vascular scaffolds: lessons learned and future directions","volume":"16","author":"Jinnouchi","year":"2019","journal-title":"Nat. Rev. Cardiol."},{"key":"10.1016\/j.actbio.2022.01.045_bib0002","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.actbio.2017.07.019","article-title":"Current status and future direction of biodegradable metallic and polymeric vascular scaffolds for next-generation stents","volume":"60","author":"Im","year":"2017","journal-title":"Acta Biomater."},{"key":"10.1016\/j.actbio.2022.01.045_bib0003","doi-asserted-by":"crossref","DOI":"10.1016\/j.biomaterials.2019.119641","article-title":"Evolution of metallic cardiovascular stent materials: a comparative study among stainless steel, magnesium and zinc","volume":"230","author":"Fu","year":"2020","journal-title":"Biomaterials"},{"key":"10.1016\/j.actbio.2022.01.045_bib0004","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1016\/j.actbio.2019.11.013","article-title":"Comparative in vitro study on binary Mg-RE (Sc, Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu) alloy systems","volume":"102","author":"Liu","year":"2020","journal-title":"Acta Biomater."},{"issue":"6","key":"10.1016\/j.actbio.2022.01.045_bib0005","doi-asserted-by":"crossref","first-page":"5937","DOI":"10.1021\/acsnano.5b00651","article-title":"Bioresorbable Electronic Stent Integrated with Therapeutic Nanoparticles for Endovascular Diseases","volume":"9","author":"Son","year":"2015","journal-title":"ACS Nano"},{"issue":"24","key":"10.1016\/j.actbio.2022.01.045_bib0006","doi-asserted-by":"crossref","first-page":"2319","DOI":"10.1056\/NEJMoa1614954","article-title":"Bioresorbable scaffolds versus metallic stents in routine PCI","volume":"376","author":"Wykrzykowska","year":"2017","journal-title":"N. Engl. J. Med."},{"issue":"7","key":"10.1016\/j.actbio.2022.01.045_bib0007","first-page":"E674","article-title":"Mechanical properties of the drug-eluting bioresorbable magnesium scaffold compared with polymeric scaffolds and a permanent metallic drug-eluting stent","volume":"96","author":"Barkholt","year":"2020","journal-title":"Catheter. Cardiovasc. Interv."},{"issue":"1","key":"10.1016\/j.actbio.2022.01.045_bib0008","doi-asserted-by":"crossref","first-page":"46343","DOI":"10.1038\/srep46343","article-title":"A promising biodegradable magnesium alloy suitable for clinical vascular stent application","volume":"7","author":"Mao","year":"2017","journal-title":"Sci. Rep."},{"key":"10.1016\/j.actbio.2022.01.045_bib0009","doi-asserted-by":"crossref","first-page":"1261","DOI":"10.1007\/s11517-016-1584-8","article-title":"Plastic strains during stent deployment have a critical influence on the rate of corrosion in absorbable magnesium stents","volume":"55","author":"Galvin","year":"2017","journal-title":"Med. Biol. Eng. Comput."},{"key":"10.1016\/j.actbio.2022.01.045_bib0010","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1016\/j.actbio.2018.01.018","article-title":"The degradation and transport mechanism of a Mg-Nd-Zn-Zr stent in rabbit common carotid artery: a 20-month study","volume":"69","author":"Zhang","year":"2018","journal-title":"Acta Biomater."},{"key":"10.1016\/j.actbio.2022.01.045_bib0011","doi-asserted-by":"crossref","DOI":"10.1016\/j.biomaterials.2019.119414","article-title":"In vivo and in vitro evaluation of a biodegradable magnesium vascular stent designed by shape optimization strategy","volume":"221","author":"Chen","year":"2019","journal-title":"Biomaterials"},{"key":"10.1016\/j.actbio.2022.01.045_bib0012","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1016\/j.msec.2014.05.078","article-title":"Finite element analyses for optimization design of biodegradable magnesium alloy stent","volume":"42","author":"Li","year":"2014","journal-title":"Mater. Sci. Eng. C Mater. Biol. Appl."},{"key":"10.1016\/j.actbio.2022.01.045_bib0013","first-page":"1","article-title":"Multiobjective design of a biodegradable coronary artery stent","volume":"15","author":"Bressloff","year":"2014","journal-title":"Stud. Mechanobiol. Tissue Eng. Biomater."},{"issue":"3","key":"10.1016\/j.actbio.2022.01.045_bib0014","doi-asserted-by":"crossref","first-page":"800","DOI":"10.1016\/j.ijcard.2014.09.143","article-title":"Impact of stent strut design in metallic stents and biodegradable scaffolds","volume":"177","author":"Foin","year":"2014","journal-title":"Int. J. Cardiol."},{"issue":"25","key":"10.1016\/j.actbio.2022.01.045_bib0015","doi-asserted-by":"crossref","first-page":"3287","DOI":"10.1016\/j.jacc.2018.09.019","article-title":"Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin Durable Polymer Everolimus-Eluting Stents","volume":"72","author":"Kandzari","year":"2018","journal-title":"J. Am. Coll. Cardiol."},{"issue":"8","key":"10.1016\/j.actbio.2022.01.045_bib0016","doi-asserted-by":"crossref","first-page":"1283","DOI":"10.1016\/S0735-1097(03)00119-0","article-title":"Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial","volume":"41","author":"Pache","year":"2003","journal-title":"J. Am. Coll. Cardiol."},{"issue":"4","key":"10.1016\/j.actbio.2022.01.045_bib0017","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1016\/j.patbio.2004.03.013","article-title":"The influence of physical stent parameters upon restenosis","volume":"52","author":"Morton","year":"2004","journal-title":"Pathol. Biol."},{"issue":"10","key":"10.1016\/j.actbio.2022.01.045_bib0018","doi-asserted-by":"crossref","first-page":"1652","DOI":"10.1016\/j.amjcard.2018.07.040","article-title":"Meta-Analysis of the Impact of Strut Thickness on Outcomes in Patients With Drug-Eluting Stents in a Coronary Artery","volume":"122","author":"Iantorno","year":"2018","journal-title":"Am. J. Cardiol."},{"issue":"5","key":"10.1016\/j.actbio.2022.01.045_bib0019","first-page":"776","article-title":"Initial findings of impact of strut width on stent coverage and apposition of sirolimus-eluting stents assessed by optical coherence tomography","volume":"81","author":"Shimpei","year":"2013","journal-title":"Catheter Cardio Inte"},{"key":"10.1016\/j.actbio.2022.01.045_bib0020","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1016\/j.jmbbm.2018.09.005","article-title":"Optimizing the deformation behavior of stent with nonuniform Poisson's ratio distribution for curved artery","volume":"88","author":"Han","year":"2018","journal-title":"J. Mech. Behav. Biomed."},{"issue":"1","key":"10.1016\/j.actbio.2022.01.045_bib0021","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1007\/s11517-018-1864-6","article-title":"Multiobjective design optimization of stent geometry with wall deformation for triangular and rectangular struts","volume":"57","author":"Putra","year":"2018","journal-title":"Med. Biol. Eng. Comput."},{"issue":"28","key":"10.1016\/j.actbio.2022.01.045_bib0022","first-page":"16","article-title":"Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial","volume":"103","author":"Kastrati","year":"2001","journal-title":"Circulation"},{"issue":"12","key":"10.1016\/j.actbio.2022.01.045_bib0023","doi-asserted-by":"crossref","first-page":"1178","DOI":"10.1038\/nmat4991","article-title":"Leveraging advances in biology to design biomaterials","volume":"16","author":"Darnell","year":"2017","journal-title":"Nat. Mater."},{"key":"10.1016\/j.actbio.2022.01.045_bib0024","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.msec.2018.04.100","article-title":"Biodegradable stents for coronary artery disease treatment: recent advances and future perspectives","volume":"91","author":"Hu","year":"2018","journal-title":"Mater. Sci. Eng. C Mater. Biol. Appl."},{"key":"10.1016\/j.actbio.2022.01.045_bib0025","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1016\/j.ijcard.2016.11.258","article-title":"Bioresorbable stents: current and upcoming bioresorbable technologies","volume":"228","author":"Ang","year":"2017","journal-title":"Int. J. Cardiol."},{"issue":"33","key":"10.1016\/j.actbio.2022.01.045_bib0026","doi-asserted-by":"crossref","first-page":"8049","DOI":"10.1016\/j.biomaterials.2013.07.010","article-title":"Optimizing the design of a bioabsorbable metal stent using computer simulation methods","volume":"34","author":"Grogan","year":"2013","journal-title":"Biomaterials"},{"key":"10.1016\/j.actbio.2022.01.045_bib0027","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.medengphy.2018.04.017","article-title":"Assessment of structural and hemodynamic performance of vascular stents modelled as periodic lattices","volume":"57","author":"Prithipaul","year":"2018","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.actbio.2022.01.045_bib0028","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/j.ijcard.2016.11.065","article-title":"The conical stent in coronary artery improves hemodynamics compared with the traditional cylindrical stent","volume":"227","author":"Yu","year":"2017","journal-title":"Int. J. Cardiol."},{"key":"10.1016\/j.actbio.2022.01.045_bib0029","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1016\/j.matdes.2015.10.153","article-title":"Multiobjective robust optimization of coronary stents","volume":"90","author":"Tammareddi","year":"2016","journal-title":"Mater. Des."},{"key":"10.1016\/j.actbio.2022.01.045_bib0030","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/S0002-9149(00)01268-6","article-title":"Restenosis after coronary placement of various stent types","volume":"87","author":"Kastrati","year":"2001","journal-title":"Am. J. Cardiol."},{"key":"10.1016\/j.actbio.2022.01.045_bib0031","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1161\/01.RES.84.4.378","article-title":"Balloon-artery interactions during stent placement: a finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury","volume":"84","author":"Rogers","year":"1999","journal-title":"Circ. Res."},{"issue":"6\u20137","key":"10.1016\/j.actbio.2022.01.045_bib0032","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1016\/j.finel.2009.01.001","article-title":"Shape optimization of coronary artery stent based on a parametric model","volume":"45","author":"Li","year":"2009","journal-title":"Finite Elem. Anal. Des."},{"issue":"9","key":"10.1016\/j.actbio.2022.01.045_bib0033","doi-asserted-by":"crossref","first-page":"2829","DOI":"10.1007\/s10439-010-0057-8","article-title":"Finite element shape optimization for biodegradable magnesium alloy stents","volume":"38","author":"Wu","year":"2010","journal-title":"Ann. Biomed. Eng."},{"issue":"17","key":"10.1016\/j.actbio.2022.01.045_bib0034","doi-asserted-by":"crossref","first-page":"B11","DOI":"10.1016\/j.jacc.2012.08.046","article-title":"TCT-38 two-year clinical data of cohort 1 and multi-modality imaging results up to 1-year follow-up of the BIOSOLVE-I study with the paclitaxel-eluting bioabsorbable magnesium scaffold (DREAMS)","volume":"60","author":"Haude","year":"2012","journal-title":"J. Am. Coll. Cardiol."},{"issue":"9869","key":"10.1016\/j.actbio.2022.01.045_bib0035","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1016\/S0140-6736(12)61765-6","article-title":"Safety and performance of the drug-eluting absorbable metal scaffold (DREAMS) in patients with de-novo coronary lesions: 12 month results of the prospective, multicentre, first-in-man BIOSOLVE-I trial","volume":"381","author":"Haude","year":"2013","journal-title":"The Lancet"},{"issue":"1","key":"10.1016\/j.actbio.2022.01.045_bib0036","doi-asserted-by":"crossref","first-page":"20","DOI":"10.3390\/polym9010020","article-title":"Multi-Objective Optimizations of Biodegradable Polymer Stent Structure and Stent Microinjection Molding Process","volume":"9","author":"Li","year":"2017","journal-title":"Polymers (Basel)"},{"issue":"1","key":"10.1016\/j.actbio.2022.01.045_bib0037","first-page":"171","article-title":"Orthogonal-Maximin Latin Hypercube Designs","volume":"18","author":"Joseph","year":"2012","journal-title":"Stat. Sin."},{"key":"10.1016\/j.actbio.2022.01.045_bib0038","doi-asserted-by":"crossref","DOI":"10.1016\/j.jclepro.2020.119964","article-title":"Machine learning-based multi-objective optimisation of an aerogel glazing system using NSGA-II\u2014Study of modelling and application in the subtropical climate Hong Kong","volume":"253","author":"Zhou","year":"2020","journal-title":"J. Clean. Prod."},{"key":"10.1016\/j.actbio.2022.01.045_bib0039","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1016\/j.msec.2018.05.005","article-title":"Processing and properties of magnesium alloy micro-tubes for biodegradable vascular stents","volume":"90","author":"Wang","year":"2018","journal-title":"Mater. Sci. Eng. C Mater. Biol. Appl."},{"key":"10.1016\/j.actbio.2022.01.045_bib0040","doi-asserted-by":"crossref","DOI":"10.1016\/j.jallcom.2020.155369","article-title":"Microstructure and properties of biodegradable Mg\u2013Zn\u2013Y-Nd alloy micro-tubes prepared by an improved method","volume":"835","author":"Li","year":"2020","journal-title":"J. Alloy Compd."},{"issue":"287","key":"10.1016\/j.actbio.2022.01.045_bib0041","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1080\/01621459.1959.10501525","article-title":"A Basis for the Selection of a Response Surface Design","volume":"54","author":"Box","year":"1959","journal-title":"J. Am. Stat. Assoc."},{"key":"10.1016\/j.actbio.2022.01.045_bib0042","author":"Draper","year":"1966","journal-title":"Appl. Regression Anal. Vol. 3 Wiley New York,"},{"key":"10.1016\/j.actbio.2022.01.045_bib0043","unstructured":"ISO, 25539-2:2008 Cardiovascular Implants\u2014Endovascular Devices\u2014Part 2: vascular Stents."},{"key":"10.1016\/j.actbio.2022.01.045_bib0044","unstructured":"ASTM, F3067-14 Radial Loading of Balloon Expandable and Self Expanding Vascular Stents, (2014)."},{"key":"10.1016\/j.actbio.2022.01.045_bib0045","unstructured":"ASTM, F2394-07 Measuring Securement of Balloon Expandable Vascular Stent Mounted on Delivery System, (2017)."},{"issue":"28","key":"10.1016\/j.actbio.2022.01.045_bib0046","doi-asserted-by":"crossref","first-page":"17842","DOI":"10.1021\/acsami.6b05038","article-title":"Enhanced in Vitro and in Vivo Performance of Mg\u2212Zn\u2212Y\u2212Nd Alloy Achieved with APTES Pretreatment for Drug-Eluting Vascular Stent Application","volume":"8","author":"Liu","year":"2016","journal-title":"Acs Appl. Mater. Inter."},{"key":"10.1016\/j.actbio.2022.01.045_bib0047","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2019\/2960435","article-title":"Structural design of mechanical property for biodegradable polymeric stent","volume":"2019","author":"Wei","year":"2019","journal-title":"Adv. Mater. Sci. Eng."},{"key":"10.1016\/j.actbio.2022.01.045_bib0048","first-page":"1","article-title":"Mechanical properties of the drug-eluting bioresorbable magnesium scaffold compared with polymeric scaffolds and a permanent metallic drug-eluting stent","author":"Barkholt","year":"2019","journal-title":"Catheter Cardio Inte"},{"key":"10.1016\/j.actbio.2022.01.045_bib0049","doi-asserted-by":"crossref","first-page":"1869","DOI":"10.1016\/S0140-6736(07)60853-8","article-title":"Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial","volume":"369","author":"Erbel","year":"2007","journal-title":"The Lancet"},{"issue":"10","key":"10.1016\/j.actbio.2022.01.045_bib0050","first-page":"1153","article-title":"Research Progress in Bioresorbable Magnesium Scaffolds","volume":"53","author":"Xi","year":"2017","journal-title":"Acta Metall Sin"}],"container-title":["Acta Biomaterialia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S174270612200054X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S174270612200054X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T17:50:32Z","timestamp":1761673832000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S174270612200054X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4]]},"references-count":50,"alternative-id":["S174270612200054X"],"URL":"https:\/\/doi.org\/10.1016\/j.actbio.2022.01.045","relation":{},"ISSN":["1742-7061"],"issn-type":[{"value":"1742-7061","type":"print"}],"subject":[],"published":{"date-parts":[[2022,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A biodegradable magnesium alloy vascular stent structure: Design, optimisation and evaluation","name":"articletitle","label":"Article Title"},{"value":"Acta Biomaterialia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.actbio.2022.01.045","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}