{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T04:23:31Z","timestamp":1793679811234,"version":"4.5.1"},"reference-count":70,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,3,1]],"date-time":"2023-03-01T00:00:00Z","timestamp":1677628800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,3,1]],"date-time":"2023-03-01T00:00:00Z","timestamp":1677628800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,1,17]],"date-time":"2023-01-17T00:00:00Z","timestamp":1673913600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100004313","name":"General Electric","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004313","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100019310","name":"Northwell Health Feinstein Institutes for Medical Research","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100019310","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007150","name":"United Therapeutics Corporation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007150","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100009455","name":"West Virginia University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100009455","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100014126","name":"GE Global Research","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100014126","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Acta Biomaterialia"],"published-print":{"date-parts":[[2023,3]]},"DOI":"10.1016\/j.actbio.2023.01.026","type":"journal-article","created":{"date-parts":[[2023,1,17]],"date-time":"2023-01-17T05:59:05Z","timestamp":1673935145000},"page":"394-409","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":31,"special_numbering":"C","title":["Flexible IrOx neural electrode for mouse vagus nerve stimulation"],"prefix":"10.1016","volume":"159","author":[{"given":"Tao","family":"Sun","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T\u00e9a","family":"Tsaava","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joanne","family":"Peragine","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6069-900X","authenticated-orcid":false,"given":"Christine","family":"Crosfield","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Fernanda","family":"Lopez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Romil","family":"Modi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rohit","family":"Sharma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunyan","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harbaljit","family":"Sohal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5592-4276","authenticated-orcid":false,"given":"Eric H.","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6772-253X","authenticated-orcid":false,"given":"Loren","family":"Rieth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.actbio.2023.01.026_bib0001","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/S1474-4422(02)00220-X","article-title":"Vagus-nerve stimulation for the treatment of epilepsy","volume":"1","author":"Ben-Menachem","year":"2002","journal-title":"Lancet Neurol."},{"key":"10.1016\/j.actbio.2023.01.026_bib0002","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1007\/s11916-015-0528-6","article-title":"Review of the uses of vagal nerve stimulation in chronic pain management","volume":"19","author":"Chakravarthy","year":"2015","journal-title":"Curr. Pain Headache Rep."},{"key":"10.1016\/j.actbio.2023.01.026_bib0003","doi-asserted-by":"crossref","first-page":"5781","DOI":"10.1113\/JP271539","article-title":"Anti-inflammatory properties of the vagus nerve: potential therapeutic implications of vagus nerve stimulation","volume":"594","author":"Bonaz","year":"2016","journal-title":"J. Physiol."},{"key":"10.1016\/j.actbio.2023.01.026_bib0004","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1038\/nrd4351","article-title":"Bioelectronic medicines: a research roadmap","volume":"13","author":"Birmingham","year":"2014","journal-title":"Nat. Rev. Drug Discov"},{"key":"10.1016\/j.actbio.2023.01.026_bib0005","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1111\/joim.12967","article-title":"Bioelectronic medicine: an unexpected path to new therapies","volume":"286","author":"Olofsson","year":"2019","journal-title":"J. Intern. Med."},{"key":"10.1016\/j.actbio.2023.01.026_bib0006","doi-asserted-by":"crossref","first-page":"44","DOI":"10.3389\/fpsyt.2018.00044","article-title":"Vagus nerve as modulator of the brain\u2013gut axis in psychiatric and inflammatory disorders","volume":"9","author":"Breit","year":"2018","journal-title":"Front. Psychiatry"},{"key":"10.1016\/j.actbio.2023.01.026_bib0007","doi-asserted-by":"crossref","first-page":"878","DOI":"10.1038\/s41586-022-04515-5","article-title":"A multidimensional coding architecture of the vagal interoceptive system","volume":"603","author":"Zhao","year":"2022","journal-title":"Nature"},{"key":"10.1016\/j.actbio.2023.01.026_bib0008","doi-asserted-by":"crossref","first-page":"203","DOI":"10.2147\/JIR.S163248","article-title":"A review of vagus nerve stimulation as a therapeutic intervention","volume":"11","author":"Johnson","year":"2018","journal-title":"J. Inflamm. Res."},{"key":"10.1016\/j.actbio.2023.01.026_bib0009","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1016\/j.berh.2014.10.015","article-title":"Vagus nerve stimulation: a new bioelectronics approach to treat rheumatoid arthritis?","volume":"28","author":"Koopman","year":"2014","journal-title":"Best Pract. Res. Clin. Rheumatol."},{"key":"10.1016\/j.actbio.2023.01.026_bib0010","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1007\/s11906-015-0532-6","article-title":"Vagal modulation of hypertension","volume":"17","author":"Petkovich","year":"2015","journal-title":"Curr. Hypertens. Rep."},{"key":"10.1016\/j.actbio.2023.01.026_bib0011","doi-asserted-by":"crossref","first-page":"5791","DOI":"10.1113\/JP271538","article-title":"Role of the vagus nerve in the development and treatment of diet-induced obesity","volume":"594","author":"de Lartigue","year":"2016","journal-title":"J. Physiol."},{"key":"10.1016\/j.actbio.2023.01.026_bib0012","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1038\/s41575-018-0078-6","article-title":"Bioelectric neuromodulation for gastrointestinal disorders: effectiveness and mechanisms","volume":"16","author":"Payne","year":"2019","journal-title":"Nat. Rev. Gastroenterol. Hepatol."},{"key":"10.1016\/j.actbio.2023.01.026_bib0013","doi-asserted-by":"crossref","first-page":"46006","DOI":"10.1088\/1741-2552\/ab9a9a","article-title":"Stability of flexible thin-film metallization stimulation electrodes: analysis of explants after first-in-human study and improvement of in vivo performance","volume":"17","author":"\u010cvan\u010dara","year":"2020","journal-title":"J. Neural Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0014","doi-asserted-by":"crossref","first-page":"4256","DOI":"10.1039\/C5LC00809C","article-title":"Materials for microfabricated implantable devices: a review","volume":"15","author":"Scholten","year":"2015","journal-title":"Lab Chip"},{"key":"10.1016\/j.actbio.2023.01.026_bib0015","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1109\/TNSRE.2011.2109399","article-title":"In vitro and in vivo evaluation of PEDOT microelectrodes for neural stimulation and recording","volume":"19","author":"Venkatraman","year":"2011","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0016","doi-asserted-by":"crossref","first-page":"66002","DOI":"10.1088\/1741-2552\/ab2e79","article-title":"Electrically conducting diamond films grown on platinum foil for neural stimulation","volume":"16","author":"Sikder","year":"2019","journal-title":"J. Neural Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0017","doi-asserted-by":"crossref","first-page":"16015","DOI":"10.1088\/1741-2552\/ab5163","article-title":"Electrochemical and mechanical performance of reduced graphene oxide, conductive hydrogel, and electrodeposited Pt{\\textendash}Ir coated electrodes: an active in vitro study","volume":"17","author":"Dalrymple","year":"2019","journal-title":"J. Neural Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0018","doi-asserted-by":"crossref","first-page":"6958","DOI":"10.1038\/s41598-018-25198-x","article-title":"Ultra-capacitive carbon neural probe allows simultaneous long-term electrical stimulations and high-resolution neurotransmitter detection","volume":"8","author":"Nimbalkar","year":"2018","journal-title":"Sci. Rep."},{"key":"10.1016\/j.actbio.2023.01.026_bib0019","doi-asserted-by":"crossref","first-page":"880","DOI":"10.1002\/jbm.b.34442","article-title":"High-charge-capacity sputtered iridium oxide neural stimulation electrodes deposited using water vapor as a reactive plasma constituent","volume":"108","author":"Maeng","year":"2020","journal-title":"J. Biomed. Mater. Res. Part B Appl. Biomater."},{"key":"10.1016\/j.actbio.2023.01.026_bib0020","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.bios.2010.05.010","article-title":"A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve","volume":"26","author":"Boretius","year":"2010","journal-title":"Biosens. Bioelectron."},{"key":"10.1016\/j.actbio.2023.01.026_bib0021","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1109\/TNSRE.2004.831491","article-title":"Acute peripheral nerve recording characteristics of polymer-based longitudinal intrafascicular electrodes","volume":"12","author":"Lawrence","year":"2004","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0022","doi-asserted-by":"crossref","first-page":"56042","DOI":"10.1088\/1741-2552\/abc025","article-title":"Long-term performance of Utah slanted electrode arrays and intramuscular electromyographic leads implanted chronically in human arm nerves and muscles","volume":"17","author":"George","year":"2020","journal-title":"J. Neural Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0023","doi-asserted-by":"crossref","first-page":"1757","DOI":"10.1109\/TBME.2010.2041778","article-title":"Flexible split-ring electrode for insect flight biasing using multisite neural stimulation","volume":"57","author":"Tsang","year":"2010","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0024","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1109\/10.8670","article-title":"A spiral nerve cuff electrode for peripheral nerve stimulation","volume":"35","author":"Naples","year":"1988","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0025","doi-asserted-by":"crossref","first-page":"35015","DOI":"10.1088\/0960-1317\/20\/3\/035015","article-title":"Fabrication and characterization of implantable and flexible nerve cuff electrodes with Pt, Ir and {IrOxfilms} deposited by {RF} sputtering","volume":"20","author":"Lee","year":"2010","journal-title":"J. Micromech. Microeng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0026","doi-asserted-by":"crossref","first-page":"65003","DOI":"10.1088\/0960-1317\/24\/6\/065003","article-title":"Formation of three-dimensional Parylene C structures via thermoforming","volume":"24","author":"Kim","year":"2014","journal-title":"J. Micromech. Microeng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0027","doi-asserted-by":"crossref","first-page":"3028","DOI":"10.1016\/j.tsf.2007.11.113","article-title":"Surface characteristics and adhesive strengths of metal on O2 ion beam treated polyimide substrate","volume":"516","author":"Park","year":"2008","journal-title":"Thin Solid Films"},{"key":"10.1016\/j.actbio.2023.01.026_bib0028","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1002\/jbm.b.31223","article-title":"Sputtered iridium oxide films for neural stimulation electrodes","volume":"89B","author":"Cogan","year":"2009","journal-title":"J. Biomed. Mater. Res. Part B Appl. Biomater."},{"issue":"3","key":"10.1016\/j.actbio.2023.01.026_bib0029","article-title":"Standardization of methods to record Vagus nerve activity in mice","volume":"4","author":"Silverman","year":"2018","journal-title":"Bioelectron. Med."},{"key":"10.1016\/j.actbio.2023.01.026_bib0030","doi-asserted-by":"crossref","first-page":"15007","DOI":"10.1088\/1748-6041\/5\/1\/015007","article-title":"In vitro comparison of sputtered iridium oxide and platinum-coated neural implantable microelectrode arrays","volume":"5","author":"Negi","year":"2010","journal-title":"Biomed. Mater."},{"key":"10.1016\/j.actbio.2023.01.026_bib0031","doi-asserted-by":"crossref","first-page":"6733","DOI":"10.1039\/c2jm16633j","article-title":"Surface area and pore size characteristics of nanoporous gold subjected to thermal{,} mechanical{,} or surface modification studied using gas adsorption isotherms{,} cyclic voltammetry{,} thermogravimetric analysis{,} and scanning electron microscopy","volume":"22","author":"Tan","year":"2012","journal-title":"J. Mater. Chem."},{"key":"10.1016\/j.actbio.2023.01.026_bib0032","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/j.micromeso.2011.02.023","article-title":"Pore analysis of obliquely deposited nanostructures by krypton gas adsorption at 87K","volume":"143","author":"Krause","year":"2011","journal-title":"Microporous Mesoporous Mater."},{"key":"10.1016\/j.actbio.2023.01.026_bib0033","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1016\/j.snb.2008.11.015","article-title":"Effect of sputtering pressure on pulsed-DC sputtered iridium oxide films","volume":"137","author":"Negi","year":"2009","journal-title":"Sens. Actuators B Chem."},{"key":"10.1016\/j.actbio.2023.01.026_bib0034","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.jneumeth.2009.10.016","article-title":"Neural electrode degradation from continuous electrical stimulation: comparison of sputtered and activated iridium oxide","volume":"186","author":"Negi","year":"2010","journal-title":"J. Neurosci. Methods"},{"key":"10.1016\/j.actbio.2023.01.026_bib0035","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.1109\/TBME.2005.847523","article-title":"Impedance characterization and modeling of electrodes for biomedical applications","volume":"52","author":"Franks","year":"2005","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0036","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.jneumeth.2017.10.002","article-title":"Neural electrode resilience against dielectric damage may be improved by use of highly doped silicon as a conductive material","volume":"293","author":"Caldwell","year":"2018","journal-title":"J. Neurosci. Methods."},{"key":"10.1016\/j.actbio.2023.01.026_bib0037","doi-asserted-by":"crossref","first-page":"56001","DOI":"10.1088\/1741-2552\/abb9bf","article-title":"Activated iridium oxide film (AIROF) electrodes for neural tissue stimulation","volume":"17","author":"Frederick","year":"2020","journal-title":"J. Neural Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0038","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.ijrmhm.2014.01.010","article-title":"Long-term high-temperature oxidation of iridium coated rhenium by electrical resistance heating method","volume":"44","author":"Zhu","year":"2014","journal-title":"Int. J. Refract. Met. Hard Mater."},{"issue":"F3132","key":"10.1016\/j.actbio.2023.01.026_bib0039","article-title":"Activity and stability of electrochemically and thermally treated iridium for the oxygen evolution reaction","volume":"163","author":"Geiger","year":"2016","journal-title":"J. Electrochem. Soc."},{"key":"10.1016\/j.actbio.2023.01.026_bib0040","doi-asserted-by":"crossref","first-page":"911","DOI":"10.3389\/fnins.2019.00911","article-title":"Vagus nerve stimulation in rodent models: an overview of technical considerations","volume":"13","author":"Noller","year":"2019","journal-title":"Front. Neurosci."},{"key":"10.1016\/j.actbio.2023.01.026_bib0041","doi-asserted-by":"crossref","first-page":"924","DOI":"10.1016\/j.snb.2016.06.169","article-title":"Characterization of nerve-cuff electrode interface for biocompatible and chronic stimulating application","volume":"237","author":"Lee","year":"2016","journal-title":"Sens. Actuators B Chem."},{"key":"10.1016\/j.actbio.2023.01.026_bib0042","doi-asserted-by":"crossref","first-page":"74009","DOI":"10.1088\/0960-1317\/19\/7\/074009","article-title":"Iridium oxide deposited by pulsed dc-sputtering for stimulation electrodes","volume":"19","author":"van Ooyen","year":"2009","journal-title":"J. Micromech. Microeng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0043","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1111\/head.12647","article-title":"Vagus nerve and vagus nerve stimulation, a comprehensive review: part I","volume":"56","author":"Yuan","year":"2016","journal-title":"Headache J. Head Face Pain"},{"key":"10.1016\/j.actbio.2023.01.026_bib0044","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1038\/hr.2015.122","article-title":"Effect of selective vagal nerve stimulation on blood pressure, heart rate and respiratory rate in rats under metoprolol medication","volume":"39","author":"Gierthmuehlen","year":"2016","journal-title":"Hypertens. Res."},{"key":"10.1016\/j.actbio.2023.01.026_bib0045","doi-asserted-by":"crossref","DOI":"10.14814\/phy2.12689","article-title":"Modulation of heart rate by temporally patterned vagus nerve stimulation in the anesthetized dog","volume":"4","author":"Yoo","year":"2016","journal-title":"Physiol. Rep."},{"key":"10.1016\/j.actbio.2023.01.026_bib0046","doi-asserted-by":"crossref","first-page":"21","DOI":"10.2217\/bem-2017-0001","article-title":"Calibration of thresholds for functional engagement of vagal A, B and C fiber groups in vivo","volume":"1","author":"McAllen","year":"2017","journal-title":"Bioelectron. Med."},{"key":"10.1016\/j.actbio.2023.01.026_bib0047","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1109\/TNSRE.2005.847373","article-title":"Repeated voltage biasing improves unit recordings by reducing resistive tissue impedances","volume":"13","author":"Johnson","year":"2005","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0048","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1109\/TBME.2005.862530","article-title":"Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes","volume":"53","author":"Otto","year":"2006","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0049","first-page":"7139","article-title":"Effects of adsorbed proteins, an antifouling agent and long-duration DC voltage pulses on the impedance of silicon-based neural microelectrodes","author":"Sommakia","year":"2009","journal-title":"Annu. Int. Conf. IEEE Eng. Med. Biol. Soc."},{"key":"10.1016\/j.actbio.2023.01.026_bib0050","doi-asserted-by":"crossref","DOI":"10.1016\/j.biomaterials.2019.119731","article-title":"Characterization of Parylene-C degradation mechanisms: In vitro reactive accelerated aging model compared to multiyear in vivo implantation","volume":"232","author":"Caldwell","year":"2020","journal-title":"Biomaterials"},{"key":"10.1016\/j.actbio.2023.01.026_bib0051","doi-asserted-by":"crossref","first-page":"2673","DOI":"10.1002\/adfm.200800306","article-title":"Theoretical and experimental studies of bending of inorganic electronic materials on plastic substrates","volume":"18","author":"Park","year":"2008","journal-title":"Adv. Funct. Mater."},{"key":"10.1016\/j.actbio.2023.01.026_bib0052","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.polymdegradstab.2016.09.026","article-title":"Enhancement of polyimide and 3D graphene-polyimide through thermoforming and its effect on mechanical properties and associated creep phenomenon","volume":"134","author":"Verker","year":"2016","journal-title":"Polym. Degrad. Stab."},{"key":"10.1016\/j.actbio.2023.01.026_bib0053","doi-asserted-by":"crossref","DOI":"10.1016\/j.snb.2019.127203","article-title":"Spatiotemporal electrochemical sensing in a smart contact lens","volume":"303","author":"Donora","year":"2020","journal-title":"Sens. Actuators B Chem."},{"key":"10.1016\/j.actbio.2023.01.026_bib0054","doi-asserted-by":"crossref","first-page":"4472","DOI":"10.1002\/adma.201503423","article-title":"Progress of flexible electronics in neural interfacing \u2013 a self-adaptive non-invasive neural ribbon electrode for small nerves recording","volume":"28","author":"Xiang","year":"2016","journal-title":"Adv. Mater."},{"key":"10.1016\/j.actbio.2023.01.026_bib0055","doi-asserted-by":"crossref","first-page":"37","DOI":"10.15424\/bioelectronmed.2015.00006","article-title":"Single-pulse and unidirectional electrical activation of the cervical vagus nerve reduces tumor necrosis factor in endotoxemia","volume":"2","author":"Olofsson","year":"2015","journal-title":"Bioelectron. Med."},{"key":"10.1016\/j.actbio.2023.01.026_bib0056","doi-asserted-by":"crossref","first-page":"3462","DOI":"10.3389\/fimmu.2020.595957","article-title":"Vagus nerve stimulation decreases pancreatitis severity in mice","volume":"11","author":"Zhang","year":"2021","journal-title":"Front. Immunol."},{"key":"10.1016\/j.actbio.2023.01.026_bib0057","doi-asserted-by":"crossref","first-page":"e61270","DOI":"10.7554\/eLife.61270","article-title":"Development and characterization of a chronic implant mouse model for vagus nerve stimulation","volume":"10","author":"Mughrabi","year":"2021","journal-title":"Elife"},{"issue":"13","key":"10.1016\/j.actbio.2023.01.026_bib0058","article-title":"Safety of long-term electrical peripheral nerve stimulation: review of the state of the art","volume":"16","author":"G\u00fcnter","year":"2019","journal-title":"J. Neuroeng. Rehabil."},{"key":"10.1016\/j.actbio.2023.01.026_bib0059","doi-asserted-by":"crossref","first-page":"21001","DOI":"10.1088\/1741-2560\/13\/2\/021001","article-title":"Tissue damage thresholds during therapeutic electrical stimulation","volume":"13","author":"Cogan","year":"2016","journal-title":"J. Neural Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0060","doi-asserted-by":"crossref","DOI":"10.1016\/j.isci.2022.104539","article-title":"Imaging the stability of chronic electrical microstimulation using electrodes coated with PEDOT\/CNT and iridium oxide","volume":"25","author":"Zheng","year":"2022","journal-title":"IScience"},{"key":"10.1016\/j.actbio.2023.01.026_bib0061","doi-asserted-by":"crossref","first-page":"849","DOI":"10.1109\/TBME.2014.2366514","article-title":"<italic>In Vivo<\/italic>and <italic>In Vitro<\/italic>comparison of the charge injection capacity of platinum macroelectrodes","volume":"62","author":"Leung","year":"2015","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0062","doi-asserted-by":"crossref","first-page":"265","DOI":"10.3389\/fnins.2015.00265","article-title":"In vivo comparison of the charge densities required to evoke motor responses using novel annular penetrating microelectrodes","volume":"9","author":"Brunton","year":"2015","journal-title":"Front. Neurosci."},{"key":"10.1016\/j.actbio.2023.01.026_bib0063","doi-asserted-by":"crossref","first-page":"2153","DOI":"10.1109\/TBME.2013.2248152","article-title":"Electrical performance of penetrating microelectrodes chronically implanted in cat cortex","volume":"60","author":"Kane","year":"2013","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/j.actbio.2023.01.026_bib0064","doi-asserted-by":"crossref","first-page":"7620","DOI":"10.1002\/adma.201501810","article-title":"Conducting polymers for neural prosthetic and neural interface applications","volume":"27","author":"Green","year":"2015","journal-title":"Adv. Mater."},{"key":"10.1016\/j.actbio.2023.01.026_bib0065","doi-asserted-by":"crossref","first-page":"4714","DOI":"10.1039\/D2TB00584K","article-title":"Carbohydrate based biomaterials for neural interface applications","volume":"10","author":"Dhawan","year":"2022","journal-title":"J. Mater. Chem. B."},{"key":"10.1016\/j.actbio.2023.01.026_bib0066","first-page":"3","article-title":"Enhanced PEDOT adhesion on solid substrates with electrografted P(EDOT-NH2)","author":"Ouyang","year":"2017","journal-title":"Sci. Adv."},{"key":"10.1016\/j.actbio.2023.01.026_bib0067","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1021\/acsami.6b13468","article-title":"Long-term stable adhesion for conducting polymers in biomedical applications: IrOx and nanostructured platinum solve the chronic challenge","volume":"9","author":"Boehler","year":"2017","journal-title":"ACS Appl. Mater. Interfaces"},{"issue":"19258","key":"10.1016\/j.actbio.2023.01.026_bib0068","article-title":"Characterization of multi-channel intraneural stimulation in transradial amputees","volume":"9","author":"Strauss","year":"2019","journal-title":"Sci. Rep."},{"key":"10.1016\/j.actbio.2023.01.026_bib0069","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.biomaterials.2017.01.014","article-title":"Long-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes","volume":"122","author":"Wurth","year":"2017","journal-title":"Biomaterials"},{"key":"10.1016\/j.actbio.2023.01.026_bib0070","doi-asserted-by":"crossref","first-page":"36029","DOI":"10.1088\/1741-2552\/ab965c","article-title":"Sputtered porous Pt for wafer-scale manufacture of low-impedance flexible microelectrodes","volume":"17","author":"Fan","year":"2020","journal-title":"J. Neural Eng."}],"container-title":["Acta Biomaterialia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1742706123000260?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1742706123000260?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T18:03:27Z","timestamp":1761674607000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1742706123000260"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3]]},"references-count":70,"alternative-id":["S1742706123000260"],"URL":"https:\/\/doi.org\/10.1016\/j.actbio.2023.01.026","relation":{},"ISSN":["1742-7061"],"issn-type":[{"value":"1742-7061","type":"print"}],"subject":[],"published":{"date-parts":[[2023,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Flexible IrOx neural electrode for mouse vagus nerve stimulation","name":"articletitle","label":"Article Title"},{"value":"Acta Biomaterialia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.actbio.2023.01.026","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Authors. Published by Elsevier Ltd on behalf of Acta Materialia Inc.","name":"copyright","label":"Copyright"}]}}