{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T15:27:16Z","timestamp":1785770836149,"version":"3.56.0"},"reference-count":139,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,12,17]],"date-time":"2025-12-17T00:00:00Z","timestamp":1765929600000},"content-version":"am","delay-in-days":350,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000070","name":"National Institute of Biomedical Imaging and Bioengineering","doi-asserted-by":"publisher","award":["R21EB028547"],"award-info":[{"award-number":["R21EB028547"]}],"id":[{"id":"10.13039\/100000070","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Acta Biomaterialia"],"published-print":{"date-parts":[[2025,1]]},"DOI":"10.1016\/j.actbio.2024.11.039","type":"journal-article","created":{"date-parts":[[2024,11,22]],"date-time":"2024-11-22T21:04:32Z","timestamp":1732309472000},"page":"336-351","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"special_numbering":"C","title":["Magnetoactive elastomer-based dynamic urethral support device for stress urinary incontinence"],"prefix":"10.1016","volume":"191","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7397-7953","authenticated-orcid":false,"given":"Seelay","family":"Tasmim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-9829-6979","authenticated-orcid":false,"given":"Asha","family":"Baten","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3218-7135","authenticated-orcid":false,"given":"Manivannan","family":"Sivaperuman Kalairaj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suitu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe E.","family":"Zimmern","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7996-7393","authenticated-orcid":false,"given":"Taylor H.","family":"Ware","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.actbio.2024.11.039_bib0001","doi-asserted-by":"crossref","first-page":"17042","DOI":"10.1038\/nrdp.2017.42","article-title":"Urinary incontinence in women","volume":"3","author":"Aoki","year":"2017","journal-title":"Nat. Rev. Dis. Primers."},{"key":"10.1016\/j.actbio.2024.11.039_bib0002","first-page":"398","article-title":"Annual Direct Cost of Urinary Incontinence","volume":"98","author":"Wilson","year":"2001","journal-title":"Obstet. Gynecol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0003","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1007\/s11934-011-0209-x","article-title":"The Financial Burden of Stress Urinary Incontinence Among Women in the United States","volume":"12","author":"Chong","year":"2011","journal-title":"Curr. Urol. Rep."},{"key":"10.1016\/j.actbio.2024.11.039_bib0004","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/S0022-5347(06)00588-X","article-title":"Increasing Costs of Urinary Incontinence Among Female Medicare Beneficiaries","volume":"176","author":"Anger","year":"2006","journal-title":"J. Urol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0005","first-page":"130","article-title":"Economic burden of urgency urinary incontinence in the United States: a systematic review","volume":"20","author":"Coyne","year":"2014","journal-title":"J. Manag. Care Pharm. : JMCP"},{"key":"10.1016\/j.actbio.2024.11.039_bib0006","doi-asserted-by":"crossref","first-page":"2286","DOI":"10.1016\/j.juro.2008.01.098","article-title":"Stress Urinary Incontinence: Relative Importance of Urethral Support and Urethral Closure Pressure","volume":"179","author":"DeLancey","year":"2008","journal-title":"J Urology"},{"key":"10.1016\/j.actbio.2024.11.039_bib0007","doi-asserted-by":"crossref","first-page":"1869","DOI":"10.1002\/nau.24760","article-title":"Urethral function and failure: A review of current knowledge of urethral closure mechanisms, how they vary, and how they are affected by life events","volume":"40","author":"Pipitone","year":"2021","journal-title":"Neurourol. Urodyn."},{"key":"10.1016\/j.actbio.2024.11.039_bib0008","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1007\/s00192-020-04622-9","article-title":"The pathophysiology of stress urinary incontinence: a systematic review and meta-analysis","volume":"32","author":"Falah-Hassani","year":"2021","journal-title":"Int. Urogynecology J."},{"key":"10.1016\/j.actbio.2024.11.039_bib0009","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/j.ogrm.2021.05.004","article-title":"Surgical treatment of stress urinary incontinence in women","volume":"31","author":"Obloza","year":"2021","journal-title":"Obstet., Gynaecol. Reprod. Med."},{"key":"10.1016\/j.actbio.2024.11.039_bib0010","doi-asserted-by":"crossref","first-page":"1713","DOI":"10.1016\/S0002-9378(12)91840-2","article-title":"Structural support of the urethra as it relates to stress urinary incontinence: The hammock hypothesis","volume":"170","author":"DeLancey","year":"1994","journal-title":"Am. J. Obstet. Gynecol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0011","doi-asserted-by":"crossref","first-page":"1251","DOI":"10.1007\/s00345-015-1599-z","article-title":"Considerations in the modern management of stress urinary incontinence resulting from intrinsic sphincter deficiency","volume":"33","author":"Hillary","year":"2015","journal-title":"World J. Urol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0012","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1186\/1472-6874-6-11","article-title":"Pelvic floor muscle training and adjunctive therapies for the treatment of stress urinary incontinence in women: a systematic review","volume":"6","author":"Neumann","year":"2006","journal-title":"BMC Women's Heal"},{"key":"10.1016\/j.actbio.2024.11.039_bib0013","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1038\/nrurol.2012.243","article-title":"Surgical management of female SUI: is there a gold standard?","volume":"10","author":"Cox","year":"2013","journal-title":"Nat. Rev. Urol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0014","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1586\/17434440.5.4.507","article-title":"Stress urinary incontinence: the evolution of the sling","volume":"5","author":"Williams","year":"2008","journal-title":"Expert Rev. M\u00e9d. Devices"},{"key":"10.1016\/j.actbio.2024.11.039_bib0015","doi-asserted-by":"crossref","first-page":"1275","DOI":"10.1007\/s00192-017-3278-7","article-title":"Intraurethral bulking agents for the management of female stress urinary incontinence: a systematic review","volume":"28","author":"Siddiqui","year":"2017","journal-title":"Int. Urogynecology J."},{"key":"10.1016\/j.actbio.2024.11.039_bib0016","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.urology.2023.12.019","article-title":"Long-term Outcomes With Macroplastique in Women With Stress Urinary Incontinence Secondary to Intrinsic Sphincter Deficiency","volume":"185","author":"Kusin","year":"2023","journal-title":"Urology."},{"key":"10.1016\/j.actbio.2024.11.039_bib0017","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1111\/luts.12372","article-title":"Durability of Macroplastique volume and configuration in women with stress urinary incontinence secondary to intrinsic sphincter deficiency: A retrospective review","volume":"13","author":"Carroll","year":"2021","journal-title":"LUTS: Low. Urin. Tract Symptoms"},{"key":"10.1016\/j.actbio.2024.11.039_bib0018","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1097\/MOU.0000000000000187","article-title":"Management of complications of mesh surgery","volume":"25","author":"Lee","year":"2015","journal-title":"Curr. Opin. Urol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0019","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1002\/nau.23046","article-title":"Sling mobilization in the management of urinary retention after mid-urethral sling surgery","volume":"36","author":"Moksnes","year":"2017","journal-title":"Neurourol Urodynam"},{"key":"10.1016\/j.actbio.2024.11.039_bib0020","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1007\/s00192-010-1177-2","article-title":"Preoperative Valsalva voiding increases the risk of urinary retention after midurethral sling placement","volume":"21","author":"Pham","year":"2010","journal-title":"Int. Urogynecol. J."},{"key":"10.1016\/j.actbio.2024.11.039_bib0021","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1007\/s00192-021-04705-1","article-title":"Urinary retention is rare after colpocleisis and concomitant midurethral sling: a 10-year experience","volume":"32","author":"Wolff","year":"2021","journal-title":"Int. Urogynecol. J."},{"key":"10.1016\/j.actbio.2024.11.039_bib0022","doi-asserted-by":"crossref","first-page":"571.e1","DOI":"10.1016\/j.ajog.2008.11.021","article-title":"The association between regional anesthesia and acute postoperative urinary retention in women undergoing outpatient midurethral sling procedures","volume":"200","author":"Wohlrab","year":"2009","journal-title":"Am. J. Obstet. Gynecol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0023","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1016\/j.anclin.2009.07.010","article-title":"Postoperative Urinary Retention","volume":"27","author":"Darrah","year":"2009","journal-title":"Anesthesiol. Clin."},{"key":"10.1016\/j.actbio.2024.11.039_bib0024","doi-asserted-by":"crossref","first-page":"1890","DOI":"10.1016\/j.juro.2008.07.029","article-title":"Complications of Mid Urethral Slings: Important Outcomes for Future Clinical Trials","volume":"180","author":"Daneshgari","year":"2008","journal-title":"J Urology"},{"key":"10.1016\/j.actbio.2024.11.039_bib0025","doi-asserted-by":"crossref","first-page":"829","DOI":"10.2147\/IJWH.S55383","article-title":"Prevention and management of postoperative urinary retention after urogynecologic surgery","volume":"6","author":"Geller","year":"2014","journal-title":"Int J Women's Heal Volume"},{"key":"10.1016\/j.actbio.2024.11.039_bib0026","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1007\/s00192-008-0666-z","article-title":"Eleven years prospective follow-up of the tension-free vaginal tape procedure for treatment of stress urinary incontinence","volume":"19","author":"Nilsson","year":"2008","journal-title":"Int. Urogynecology J."},{"key":"10.1016\/j.actbio.2024.11.039_bib0027","first-page":"210","article-title":"Re: Long-Term Efficacy of the Tension-Free Vaginal Tape Procedure for the Treatment of Urinary Incontinence: A Retrospective Follow-Up 11.5 Years Post-Operatively","volume":"186","author":"Wein","year":"2011","journal-title":"J. Urol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0028","doi-asserted-by":"crossref","first-page":"420","DOI":"10.4111\/kju.2010.51.6.420","article-title":"Readjustable Sling Procedure for the Treatment of Female Stress Urinary Incontinence with Intrinsic Sphincter Deficiency: Preliminary Report","volume":"51","author":"Yoo","year":"2010","journal-title":"Korean J Urology"},{"key":"10.1016\/j.actbio.2024.11.039_bib0029","doi-asserted-by":"crossref","first-page":"S9","DOI":"10.1007\/s001920170004","article-title":"Tension-Free Vaginal Tape (TVT) in Women with Recurrent Stress Urinary Incontinence \u2013 A Long-term Follow up","volume":"12","author":"Rezapour","year":"2001","journal-title":"Int. Urogynecol. J."},{"key":"10.1016\/j.actbio.2024.11.039_bib0030","doi-asserted-by":"crossref","first-page":"1370","DOI":"10.1097\/01.ju.0000139882.57216.45","article-title":"Tension-free vaginal tape procedure for urinary incontinence with low Valsalva leak point pressure","volume":"172","author":"Paick","year":"2004","journal-title":"J Urology"},{"key":"10.1016\/j.actbio.2024.11.039_bib0031","doi-asserted-by":"crossref","first-page":"2717","DOI":"10.1007\/s10439-017-1939-9","article-title":"Implantable Systems for Stress Urinary Incontinence","volume":"45","author":"Adem","year":"2017","journal-title":"Ann. Biomed. Eng."},{"key":"10.1016\/j.actbio.2024.11.039_bib0032","article-title":"Outcomes of open artificial urinary sphincter in women with stress urinary incontinence: long-term follow up","volume":"11","author":"Tricard","year":"2019","journal-title":"Ther Adv Urology"},{"issue":"Suppl 4","key":"10.1016\/j.actbio.2024.11.039_bib0033","first-page":"S28","article-title":"AMS-800 Artificial urinary sphincter in female patients with stress urinary incontinence: A systematic review","volume":"38","author":"Peyronnet","year":"2018","journal-title":"Neurourol. Urodyn."},{"key":"10.1016\/j.actbio.2024.11.039_bib0034","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.euf.2018.10.009","article-title":"Performance and Safety of the Artificial Urinary Sphincter (AMS 800) for Non-neurogenic Women with Urinary Incontinence Secondary to Intrinsic Sphincter Deficiency: A Systematic Review","volume":"6","author":"Reus","year":"2018","journal-title":"Eur. Urol. Focus."},{"key":"10.1016\/j.actbio.2024.11.039_bib0035","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1016\/j.eururo.2011.03.006","article-title":"Female Urinary Incontinence and Artificial Urinary Sphincter: Study of Efficacy and Risk Factors for Failure and Complications","volume":"59","author":"Vayleux","year":"2011","journal-title":"Eur. Urol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0036","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1016\/S0022-5347(05)67285-0","article-title":"THE LONG-TERM OUTCOME OF ARTIFICIAL URINARY SPHINCTERS","volume":"164","author":"VENN","year":"2000","journal-title":"J Urology"},{"key":"10.1016\/j.actbio.2024.11.039_bib0037","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1111\/j.1757-5672.2011.00129.x","article-title":"Management of Recurrent or Persistent Stress Urinary Incontinence after Mid-urethral Sling","volume":"4","author":"HAN","year":"2012","journal-title":"Luts Low Urin Tract Symptoms"},{"key":"10.1016\/j.actbio.2024.11.039_bib0038","doi-asserted-by":"crossref","first-page":"127","DOI":"10.4111\/icu.2017.58.2.127","article-title":"Efficacy and safety of a readjustable midurethral sling (Remeex system) for stress urinary incontinence with female voiding dysfunction","volume":"58","author":"Chung","year":"2016","journal-title":"Investigative Clin Urology"},{"key":"10.1016\/j.actbio.2024.11.039_bib0039","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.urology.2014.10.003","article-title":"Midterm Efficacy and Complications of Readjustable Midurethral Sling (Remeex System) in Female Stress Urinary Incontinence With Recurrence or Intrinsic Sphincter Deficiency","volume":"85","author":"Park","year":"2015","journal-title":"Urology."},{"key":"10.1016\/j.actbio.2024.11.039_bib0040","article-title":"The challenges in artificial muscle research to treat incontinence","volume":"139","author":"M\u00fcller","year":"2009","journal-title":"Swiss M\u00e9d. Wkly."},{"key":"10.1016\/j.actbio.2024.11.039_bib0041","doi-asserted-by":"crossref","first-page":"1355","DOI":"10.1007\/s10439-016-1572-z","article-title":"Artificial Muscle Devices: Innovations and Prospects for Fecal Incontinence Treatment","volume":"44","author":"Fattorini","year":"2016","journal-title":"Ann. Biomed. Eng."},{"key":"10.1016\/j.actbio.2024.11.039_bib0042","doi-asserted-by":"crossref","first-page":"3924","DOI":"10.1039\/D2BM00436D","article-title":"Synthesis of bio-based polyester elastomers and evaluation of their in vivo biocompatibility and biodegradability as biomedical materials","volume":"10","author":"Gao","year":"2022","journal-title":"Biomater. Sci."},{"key":"10.1016\/j.actbio.2024.11.039_bib0043","doi-asserted-by":"crossref","first-page":"168","DOI":"10.3390\/act11060168","article-title":"Biorobotics: An Overview of Recent Innovations in Artificial Muscles","volume":"11","author":"Craddock","year":"2022","journal-title":"Actuators."},{"key":"10.1016\/j.actbio.2024.11.039_bib0044","doi-asserted-by":"crossref","first-page":"4395","DOI":"10.1038\/s41467-021-24680-x","article-title":"Self-healing polyurethane-elastomer with mechanical tunability for multiple biomedical applications in vivo","volume":"12","author":"Jiang","year":"2021","journal-title":"Nat. Commun."},{"key":"10.1016\/j.actbio.2024.11.039_bib0045","doi-asserted-by":"crossref","first-page":"3475","DOI":"10.1007\/s12274-022-5129-1","article-title":"High-strength hydrogels: Fabrication, reinforcement mechanisms, and applications","volume":"16","author":"Huang","year":"2023","journal-title":"Nano Res."},{"key":"10.1016\/j.actbio.2024.11.039_bib0046","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1111\/aor.14434","article-title":"Artificial sphincters: An overview from existing devices to novel technologies","volume":"47","author":"Toniolo","year":"2023","journal-title":"Artif. Organs"},{"key":"10.1016\/j.actbio.2024.11.039_bib0047","doi-asserted-by":"crossref","first-page":"E337","DOI":"10.1111\/j.1464-410X.2012.11728.x","article-title":"Experimental evaluation of an electromechanical artificial urinary sphincter in an animal model","volume":"112","author":"Valerio","year":"2013","journal-title":"BJu Int."},{"key":"10.1016\/j.actbio.2024.11.039_bib0048","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1063\/1.4908588","article-title":"Micro- and nanostructured electro-active polymer actuators as smart muscles for incontinence treatment","volume":"1646","author":"Osmani","year":"2015","journal-title":"AIP Conf. Proc."},{"key":"10.1016\/j.actbio.2024.11.039_bib0049","series-title":"2014 Int. Symp. Technol. Manag. Emerg. Technol.","first-page":"44","article-title":"Design of Wireless Real Time Artificial Sphincter Control System for Urinary Incontinence","author":"Ramesh","year":"2014"},{"key":"10.1016\/j.actbio.2024.11.039_bib0050","doi-asserted-by":"crossref","DOI":"10.1088\/1361-665X\/ab3a77","article-title":"Soft robots based on dielectric elastomer actuators: a review","volume":"28","author":"Gupta","year":"2019","journal-title":"Smart Mater. Struct."},{"key":"10.1016\/j.actbio.2024.11.039_bib0051","doi-asserted-by":"crossref","DOI":"10.1016\/j.biomaterials.2022.121912","article-title":"Liquid crystal elastomer based dynamic device for urethral support: Potential treatment for stress urinary incontinence","volume":"292","author":"Tasmim","year":"2023","journal-title":"Biomaterials"},{"key":"10.1016\/j.actbio.2024.11.039_bib0052","doi-asserted-by":"crossref","unstructured":"F. of P. Russia Lomonosov Moscow State University, Leninskie Gory 1, str 2, Moscow, 119991, E.Y. Kramarenko, N.I. of O.C. Russia Russian Academy of Sciences, ul Vavilova 28, Moscow, 119991, G.V. Stepanov, S.S.C. of the R.F. Russia Institute of Chemistry and Technology of Organoelement Compounds, sh Entuziastov 38, Moscow 111123, A.R. Khokhlov, Magnetically Active Silicone Elastomers: Twenty Years of Development, INEOS OPEN 2 (2020) 178\u2013184. https:\/\/doi.org\/10.32931\/io1926r.","DOI":"10.32931\/io1926r"},{"key":"10.1016\/j.actbio.2024.11.039_bib0053","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/S0142-9418(03)00103-X","article-title":"Magnetoactive elastomer composites","volume":"23","author":"Farshad","year":"2004","journal-title":"Polym. Test."},{"key":"10.1016\/j.actbio.2024.11.039_bib0054","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1177\/1045389X15615966","article-title":"A new approach for modeling of magnetorheological elastomers","volume":"27","author":"Norouzi","year":"2016","journal-title":"J Intel Mat Syst Str"},{"key":"10.1016\/j.actbio.2024.11.039_bib0055","doi-asserted-by":"crossref","first-page":"4174","DOI":"10.1021\/acsami.0c19280","article-title":"4D Printing of Magnetoactive Soft Materials for On-Demand Magnetic Actuation Transformation","volume":"13","author":"Zhang","year":"2021","journal-title":"Acs Appl Mater Inter"},{"key":"10.1016\/j.actbio.2024.11.039_bib0056","article-title":"3D Printing of Functional Magnetic Materials: From Design to Applications","volume":"31","author":"Zhang","year":"2021","journal-title":"Adv. Funct. Mater."},{"key":"10.1016\/j.actbio.2024.11.039_bib0057","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/03091902.2021.1893397","article-title":"Development of a more clinically relevant bladder and urethral model for catheter testing","volume":"45","author":"Gammie","year":"2021","journal-title":"J. Med. Eng. Technol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0058","doi-asserted-by":"crossref","first-page":"eaax7329","DOI":"10.1126\/scirobotics.aax7329","article-title":"Ferromagnetic soft continuum robots","volume":"4","author":"Kim","year":"2019","journal-title":"Sci Robotics"},{"key":"10.1016\/j.actbio.2024.11.039_bib0059","doi-asserted-by":"crossref","first-page":"5317","DOI":"10.1021\/acs.chemrev.1c00481","article-title":"Magnetic Soft Materials and Robots","volume":"122","author":"Kim","year":"2022","journal-title":"Chem. Rev."},{"key":"10.1016\/j.actbio.2024.11.039_bib0060","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1146\/annurev-bioeng-010510-103409","article-title":"Microrobots for Minimally Invasive Medicine","volume":"12","author":"Nelson","year":"2010","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"10.1016\/j.actbio.2024.11.039_bib0061","doi-asserted-by":"crossref","unstructured":"Q. Ze, X. Kuang, S. Wu, J. Wong, S.M. Montgomery, R. Zhang, J.M. Kovitz, F. Yang, H.J. Qi, R. Zhao, Magnetic Shape Memory Polymers with Integrated Multifunctional Shape Manipulations, Arxiv (2019).","DOI":"10.1002\/adma.201906657"},{"key":"10.1016\/j.actbio.2024.11.039_bib0062","doi-asserted-by":"crossref","first-page":"eabq1456","DOI":"10.1126\/sciadv.abq1456","article-title":"Magnetic soft robotic bladder for assisted urination","volume":"8","author":"Yang","year":"2022","journal-title":"Sci. Adv."},{"key":"10.1016\/j.actbio.2024.11.039_bib0063","doi-asserted-by":"crossref","first-page":"876","DOI":"10.1021\/acsami.6b12824","article-title":"Direct-Write Fabrication of 4D Active Shape-Changing Structures Based on a Shape Memory Polymer and Its Nanocomposite","volume":"9","author":"Wei","year":"2017","journal-title":"Acs Appl Mater Inter"},{"key":"10.1016\/j.actbio.2024.11.039_bib0064","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1038\/s41586-018-0185-0","article-title":"Printing ferromagnetic domains for untethered fast-transforming soft materials","volume":"558","author":"Kim","year":"2018","journal-title":"Nature"},{"key":"10.1016\/j.actbio.2024.11.039_bib0065","doi-asserted-by":"crossref","first-page":"8368","DOI":"10.1002\/pc.27007","article-title":"Effect of NdFeB particle size on the performance of 3D printed bonded magnets of polyamide-based composites","volume":"43","author":"Xu","year":"2022","journal-title":"Polym. Compos."},{"key":"10.1016\/j.actbio.2024.11.039_bib0066","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1007\/s00192-007-0446-1","article-title":"Mechanical properties of polypropylene mesh used in pelvic floor repair","volume":"19","author":"Afonso","year":"2008","journal-title":"Int. Urogynecology J."},{"key":"10.1016\/j.actbio.2024.11.039_bib0067","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1007\/s00192-003-1041-8","article-title":"Mechanical properties of urogynecologic implant materials","volume":"14","author":"Dietz","year":"2003","journal-title":"Int. Urogynecol. J."},{"key":"10.1016\/j.actbio.2024.11.039_bib0068","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1002\/jbm.b.34138","article-title":"In vivo biocompatibility and time-dependent changes in mechanical properties of woven collagen meshes: A comparison to xenograft and synthetic mid-urethral sling materials","volume":"107","author":"Chapin","year":"2019","journal-title":"J Biomed Mater Res Part B Appl Biomaterials"},{"key":"10.1016\/j.actbio.2024.11.039_bib0069","doi-asserted-by":"crossref","unstructured":"A. Al-Mayah, Biomechanics of Soft Tissues, (2018) 1\u201325. https:\/\/doi.org\/10.1201\/9781351135825-1.","DOI":"10.1201\/9781351135825-1"},{"key":"10.1016\/j.actbio.2024.11.039_bib0070","doi-asserted-by":"crossref","first-page":"2587","DOI":"10.1007\/s10439-015-1294-7","article-title":"Characterisation of Elastic and Acoustic Properties of an Agar-Based Tissue Mimicking Material","volume":"43","author":"Brewin","year":"2015","journal-title":"Ann. Biomed. Eng."},{"key":"10.1016\/j.actbio.2024.11.039_bib0071","doi-asserted-by":"crossref","first-page":"1871","DOI":"10.1109\/TUFFC.2022.3154235","article-title":"High-Frequency Ultrasound Elastography for Assessing Elastic Properties of Skin and Scars","volume":"69","author":"Tsai","year":"2022","journal-title":"IEEE Trans. Ultrason., Ferroelectr., Freq. Control"},{"key":"10.1016\/j.actbio.2024.11.039_bib0072","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.jmbbm.2015.08.011","article-title":"Strain-rate and temperature dependent material properties of Agar and Gellan Gum used in biomedical applications","volume":"53","author":"Schiavi","year":"2015","journal-title":"J Mech Behav Biomed"},{"key":"10.1016\/j.actbio.2024.11.039_bib0073","doi-asserted-by":"crossref","DOI":"10.1088\/2057-1976\/aa7992","article-title":"Mechanical behaviour of tissue mimicking breast phantom materials","volume":"3","author":"Ismail","year":"2017","journal-title":"Biomed. Phys. Eng. Express"},{"key":"10.1016\/j.actbio.2024.11.039_bib0074","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.jmbbm.2011.05.027","article-title":"Elastic and viscoelastic characterization of agar","volume":"7","author":"Nayar","year":"2012","journal-title":"J Mech Behav Biomed"},{"key":"10.1016\/j.actbio.2024.11.039_bib0075","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.polymertesting.2017.03.018","article-title":"On the cyclic deformation behavior, fracture properties and cytotoxicity of silicone-based elastomers for biomedical applications","volume":"60","author":"Bernardi","year":"2017","journal-title":"Polym. Test."},{"key":"10.1016\/j.actbio.2024.11.039_bib0076","doi-asserted-by":"crossref","DOI":"10.1126\/scirobotics.aax7329","article-title":"Ferromagnetic soft continuum robots","volume":"4","author":"Kim","year":"2019","journal-title":"Sci. Robot."},{"key":"10.1016\/j.actbio.2024.11.039_bib0077","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1179\/174327807X238909","article-title":"Biodegradation mechanisms of polyurethane elastomers","volume":"42","author":"Christenson","year":"2007","journal-title":"Corros. Eng., Sci. Technol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0078","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.smim.2007.11.004","article-title":"Foreign body reaction to biomaterials","volume":"20","author":"Anderson","year":"2008","journal-title":"Semin. Immunol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0079","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1021\/acsbiomaterials.8b00252","article-title":"The Foreign Body Response Demystified","volume":"5","author":"Chandorkar","year":"2019","journal-title":"ACS Biomater. Sci. Eng."},{"key":"10.1016\/j.actbio.2024.11.039_bib0080","doi-asserted-by":"crossref","first-page":"4086","DOI":"10.1039\/D3CS00923H","article-title":"Degradable biomedical elastomers: paving the future of tissue repair and regenerative medicine","volume":"53","author":"Jia","year":"2024","journal-title":"Chem. Soc. Rev."},{"key":"10.1016\/j.actbio.2024.11.039_bib0081","doi-asserted-by":"crossref","first-page":"1109","DOI":"10.1002\/jbm.a.37357","article-title":"Analysis of oxidative degradation and calcification behavior of a silicone polycarbonate polyurethane-polydimethylsiloxane material","volume":"110","author":"Kayal","year":"2022","journal-title":"J. Biomed. Mater. Res. Part A"},{"key":"10.1016\/j.actbio.2024.11.039_bib0082","doi-asserted-by":"crossref","first-page":"2064","DOI":"10.1002\/jbm.b.35308","article-title":"Accelerated in vitro oxidative degradation testing of polypropylene surgical mesh","volume":"111","author":"Jain","year":"2023","journal-title":"J. Biomed. Mater. Res. Part B: Appl. Biomater."},{"key":"10.1016\/j.actbio.2024.11.039_bib0083","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1002\/jbm.a.30067","article-title":"Oxidative mechanisms of poly(carbonate urethane) and poly(ether urethane) biodegradation: In vivo and in vitro correlations","volume":"70A","author":"Christenson","year":"2004","journal-title":"J. Biomed. Mater. Res. Part A"},{"key":"10.1016\/j.actbio.2024.11.039_bib0084","doi-asserted-by":"crossref","first-page":"7190","DOI":"10.1039\/C4DT02551B","article-title":"A comparative study on the structural, optical and magnetic properties of Fe3O4 and Fe3O4@SiO2 core-shell microspheres along with an assessment of their potentiality as electrochemical double layer capacitors","volume":"44","author":"Majumder","year":"2015","journal-title":"Dalton Trans. (Camb., Engl. : 2003)"},{"key":"10.1016\/j.actbio.2024.11.039_bib0085","doi-asserted-by":"crossref","first-page":"3093","DOI":"10.1016\/j.apsusc.2009.11.079","article-title":"Re-examination of characteristic FTIR spectrum of secondary layer in bilayer oleic acid-coated Fe3O4 nanoparticles","volume":"256","author":"Yang","year":"2010","journal-title":"Appl. Surf. Sci."},{"key":"10.1016\/j.actbio.2024.11.039_bib0086","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1590\/1980-5373-mr-2016-0707","article-title":"Characterization and Chemical Stability of Hydrophilic and Hydrophobic Magnetic Nanoparticles","volume":"20","author":"Lobato","year":"2017","journal-title":"Mater. Res."},{"key":"10.1016\/j.actbio.2024.11.039_bib0087","doi-asserted-by":"crossref","DOI":"10.1088\/0964-1726\/25\/11\/115005","article-title":"Carbonyl iron powder surface modification of magnetorheological elastomers for vibration absorbing application","volume":"25","author":"Chen","year":"2016","journal-title":"Smart Mater. Struct."},{"key":"10.1016\/j.actbio.2024.11.039_bib0088","doi-asserted-by":"crossref","first-page":"5317","DOI":"10.3390\/ma13235317","article-title":"Systematic Review on the Effects, Roles and Methods of Magnetic Particle Coatings in Magnetorheological Materials","volume":"13","author":"Jamari","year":"2020","journal-title":"Materials"},{"key":"10.1016\/j.actbio.2024.11.039_bib0089","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1016\/j.polymdegradstab.2004.05.019","article-title":"Oxidation of natural rubber-based magnetorheological elastomers","volume":"86","author":"Lokander","year":"2004","journal-title":"Polym. Degrad. Stab."},{"key":"10.1016\/j.actbio.2024.11.039_bib0090","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1002\/nau.21229","article-title":"Defining achievable standards in urodynamics\u2014a prospective study of initial resting pressures","volume":"31","author":"Sullivan","year":"2012","journal-title":"Neurourol. Urodyn."},{"key":"10.1016\/j.actbio.2024.11.039_bib0091","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/j.ogrm.2015.08.002","article-title":"Basic understanding of urodynamics","volume":"25","author":"Swithinbank","year":"2015","journal-title":"Obstet., Gynaecol. Reprod. Med."},{"key":"10.1016\/j.actbio.2024.11.039_bib0092","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.ejogrb.2012.12.013","article-title":"Factors affecting transient urinary retention after transobturator tape mid-urethral sling surgery for female patients with stress urinary incontinence: a single center experience","volume":"168","author":"Kim","year":"2013","journal-title":"Eur. J. Obstet. Gynecol. Reprod. Biol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0093","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1097\/MOU.0000000000000187","article-title":"Management of complications of mesh surgery","volume":"25","author":"Lee","year":"2015","journal-title":"Curr. Opin. Urol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0094","doi-asserted-by":"crossref","first-page":"1379","DOI":"10.1097\/01.ju.0000138555.70421.ca","article-title":"DELAYED TREATMENT OF BLADDER OUTLET OBSTRUCTION AFTER SLING SURGERY","volume":"172","author":"LENG","year":"2004","journal-title":"J. Urol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0095","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1111\/j.1464-410X.2012.11614.x","article-title":"Newer and novel artificial urinary sphincters (AUS): the development of alternatives to the current AUS device","volume":"110","author":"Chung","year":"2012","journal-title":"BJu Int."},{"key":"10.1016\/j.actbio.2024.11.039_bib0096","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1109\/TMECH.2015.2490065","article-title":"Novel Electromechanic Artificial Urinary Sphincter","volume":"21","author":"Hached","year":"2016","journal-title":"IEEEASME Trans. Mechatron."},{"key":"10.1016\/j.actbio.2024.11.039_bib0097","article-title":"The electronic artificial urinary sphincter: ongoing innovation of a classic device\u2014a narrative review","author":"Koch","year":"2023","journal-title":"Transl. Androl. Urol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0098","doi-asserted-by":"crossref","first-page":"3123","DOI":"10.1016\/j.biomaterials.2004.08.009","article-title":"Evaluation of polydimethylsiloxane scaffolds with physiologically-relevant elastic moduli: interplay of substrate mechanics and surface chemistry effects on vascular smooth muscle cell response","volume":"26","author":"Brown","year":"2005","journal-title":"Biomaterials"},{"key":"10.1016\/j.actbio.2024.11.039_bib0099","doi-asserted-by":"crossref","first-page":"2592","DOI":"10.1016\/j.biomaterials.2009.12.017","article-title":"Long term performance of small-diameter vascular grafts made of a poly(ether)urethane\u2013polydimethylsiloxane semi-interpenetrating polymeric network","volume":"31","author":"Soldani","year":"2010","journal-title":"Biomaterials"},{"key":"10.1016\/j.actbio.2024.11.039_bib0100","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1016\/j.eururo.2012.03.008","article-title":"Long-Term Results of Artificial Urinary Sphincter for Women with Type III Stress Urinary Incontinence","volume":"63","author":"Costa","year":"2013","journal-title":"Eur. Urol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0101","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.euf.2016.01.002","article-title":"Evaluation and Management of Postprostatectomy Incontinence: A Systematic Review of Current Literature","volume":"2","author":"Kretschmer","year":"2016","journal-title":"Eur. Urol. Focus"},{"key":"10.1016\/j.actbio.2024.11.039_bib0102","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1007\/s00345-015-1662-9","article-title":"Risk factors for artificial urinary sphincter failure","volume":"34","author":"Kretschmer","year":"2016","journal-title":"World J. Urol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0103","doi-asserted-by":"crossref","first-page":"6207","DOI":"10.1021\/acsapm.1c01007","article-title":"Temperature-Dependent Viscoelastic Energy Dissipation and Fatigue Crack Growth in Filled Silicone Elastomers","volume":"3","author":"Chen","year":"2021","journal-title":"ACS Appl. Polym. Mater."},{"key":"10.1016\/j.actbio.2024.11.039_bib0104","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.polymertesting.2016.12.029","article-title":"On the large strain deformation behavior of silicone-based elastomers for biomedical applications","volume":"58","author":"Bernardi","year":"2017","journal-title":"Polym. Test."},{"key":"10.1016\/j.actbio.2024.11.039_bib0105","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.polymertesting.2017.03.018","article-title":"On the cyclic deformation behavior, fracture properties and cytotoxicity of silicone-based elastomers for biomedical applications","volume":"60","author":"Bernardi","year":"2017","journal-title":"Polym. Test."},{"key":"10.1016\/j.actbio.2024.11.039_bib0106","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1002\/jbm.b.31042","article-title":"The effect of the environment on the mechanical properties of medical grade silicones","volume":"86B","author":"Leslie","year":"2008","journal-title":"J. Biomed. Mater. Res. Part B: Appl. Biomater."},{"key":"10.1016\/j.actbio.2024.11.039_bib0107","doi-asserted-by":"crossref","first-page":"4592","DOI":"10.3390\/polym14214592","article-title":"Research Progress on Fatigue Life of Rubber Materials","volume":"14","author":"Qiu","year":"2022","journal-title":"Polymers. (Basel)"},{"key":"10.1016\/j.actbio.2024.11.039_bib0108","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1007\/12_2020_80","article-title":"Fatigue Crack Growth in Rubber Materials","author":"Chazeau","year":"2020","journal-title":"Adv. Polym. Sci."},{"key":"10.1016\/j.actbio.2024.11.039_bib0109","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1002\/jbm.820080603","article-title":"The effect of implantation on the physical properties of silicone rubber","volume":"8","author":"Swanson","year":"1974","journal-title":"J. Biomed. Mater. Res."},{"key":"10.1016\/j.actbio.2024.11.039_bib0110","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/S0363-5023(97)80166-9","article-title":"Pre- and postimplantation dynamic mechanical properties of silastic HP-100 finger joints","volume":"22","author":"Naidu","year":"1997","journal-title":"J. Hand Surg."},{"key":"10.1016\/j.actbio.2024.11.039_bib0111","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/0142-9612(89)90130-0","article-title":"In vivo degradation of polymers II. Change of mechanical properties and cross-link density in silicone rubber pacemaker lead insulations during long-term implantation in the human body","volume":"10","author":"Dole\u017eel","year":"1989","journal-title":"Biomaterials"},{"key":"10.1016\/j.actbio.2024.11.039_bib0112","doi-asserted-by":"crossref","first-page":"2853","DOI":"10.1002\/app.1987.070340819","article-title":"Anisotropic reinforcement in elastomers containing magnetic filler particles","volume":"34","author":"Sohoni","year":"1987","journal-title":"J. Appl. Polym. Sci."},{"key":"10.1016\/j.actbio.2024.11.039_bib0113","doi-asserted-by":"crossref","DOI":"10.1016\/j.compscitech.2021.108955","article-title":"Control of Mullins stress softening in silicone elastomer composites by rational design of fumed silica fillers","volume":"214","author":"Allen","year":"2021","journal-title":"Compos. Sci. Technol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0114","doi-asserted-by":"crossref","first-page":"29813","DOI":"10.1039\/C9RA05833H","article-title":"Relationship between dynamic fatigue crack propagation properties and viscoelasticity of natural rubber\/silicone rubber composites","volume":"9","author":"Han","year":"2019","journal-title":"RSC. Adv."},{"key":"10.1016\/j.actbio.2024.11.039_bib0115","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1146\/annurev-bioeng-010510-103409","article-title":"Microrobots for Minimally Invasive Medicine","volume":"12","author":"Nelson","year":"2010","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"10.1016\/j.actbio.2024.11.039_bib0116","doi-asserted-by":"crossref","first-page":"3859","DOI":"10.1002\/adfm.201504699","article-title":"Actuating Soft Matter with Magnetic Torque","volume":"26","author":"Erb","year":"2016","journal-title":"Adv. Funct. Mater."},{"key":"10.1016\/j.actbio.2024.11.039_bib0117","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1111\/j.1464-410X.2012.11482.x","article-title":"New self-anchoring adjustable transobturator system","volume":"111","author":"Hoda","year":"2013","journal-title":"BJu Int."},{"key":"10.1016\/j.actbio.2024.11.039_bib0118","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/s00192-003-1066-z","article-title":"Mechanical properties of synthetic implants used in the repair of prolapse and urinary incontinence in women: which is the ideal material?","volume":"14","author":"Cosson","year":"2003","journal-title":"Int. Urogynecology J."},{"key":"10.1016\/j.actbio.2024.11.039_bib0119","doi-asserted-by":"crossref","first-page":"146","DOI":"10.4236\/oju.2013.33027","article-title":"Re-Adjustable Male Slings","volume":"2013","author":"H\u00fcbner","year":"2013","journal-title":"Open J Urology"},{"key":"10.1016\/j.actbio.2024.11.039_bib0120","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1007\/s00192-007-0499-1","article-title":"Tensile properties of five commonly used mid-urethral slings relative to the TVTTM","volume":"19","author":"Moalli","year":"2008","journal-title":"Int. Urogynecol. J."},{"key":"10.1016\/j.actbio.2024.11.039_bib0121","doi-asserted-by":"crossref","DOI":"10.1155\/2013\/240631","article-title":"Blends of Thermoplastic Polyurethane and Polydimethylsiloxane Rubber: Assessment of Biocompatibility and Suture Holding Strength of Membranes","volume":"2013","author":"Rajan","year":"2013","journal-title":"Int. J. Biomater."},{"key":"10.1016\/j.actbio.2024.11.039_bib0122","doi-asserted-by":"crossref","unstructured":"P.A. Gunatillake, R. Adhikari, Biosynthetic Polymers for Medical Applications, Part One: Introd. Fundam. (2016) 33\u201362. https:\/\/doi.org\/10.1016\/b978-1-78242-105-4.00002-x.","DOI":"10.1016\/B978-1-78242-105-4.00002-X"},{"key":"10.1016\/j.actbio.2024.11.039_bib0123","doi-asserted-by":"crossref","first-page":"5317","DOI":"10.1021\/acs.chemrev.1c00481","article-title":"Magnetic Soft Materials and Robots","volume":"122","author":"Kim","year":"2022","journal-title":"Chem. Rev."},{"key":"10.1016\/j.actbio.2024.11.039_bib0124","first-page":"335","article-title":"Testing the cytotoxicity of metal alloys used as magnetic prosthetic devices","volume":"14","author":"Hopp","year":"2003","journal-title":"J. Mater. Sci.: Mater. Med."},{"key":"10.1016\/j.actbio.2024.11.039_bib0125","doi-asserted-by":"crossref","first-page":"eabq1456","DOI":"10.1126\/sciadv.abq1456","article-title":"Magnetic soft robotic bladder for assisted urination","volume":"8","author":"Yang","year":"2022","journal-title":"Sci. Adv."},{"key":"10.1016\/j.actbio.2024.11.039_bib0126","article-title":"A Facile Magnetic System for Tracking of Medical Devices","volume":"6","author":"Swanepoel","year":"2021","journal-title":"Adv. Mater. Technol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0127","doi-asserted-by":"crossref","first-page":"3649","DOI":"10.1002\/jbm.a.35037","article-title":"Comparative analysis of in vitro oxidative degradation of poly(carbonate urethanes) for biostability screening","volume":"102","author":"Dempsey","year":"2014","journal-title":"J. Biomed. Mater. Res. Part A"},{"key":"10.1016\/j.actbio.2024.11.039_bib0128","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1111\/j.1464-410X.2005.05702.x","article-title":"A tissue-engineered suburethral sling in an animal model of stress urinary incontinence","volume":"96","author":"Cannon","year":"2005","journal-title":"BJu Int."},{"key":"10.1016\/j.actbio.2024.11.039_bib0129","doi-asserted-by":"crossref","DOI":"10.3389\/fbioe.2024.1414323","article-title":"Animal models, treatment options, and biomaterials for female stress urinary incontinence","volume":"12","author":"Tan","year":"2024","journal-title":"Front. Bioeng. Biotechnol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0130","doi-asserted-by":"crossref","first-page":"2103","DOI":"10.1016\/j.juro.2008.01.096","article-title":"Animal Models of Female Stress Urinary Incontinence","volume":"179","author":"Hijaz","year":"2008","journal-title":"J. Urol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0131","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1007\/s00192-019-04104-7","article-title":"A structured review on the female urethral anatomy and innervation with an emphasis on the role of the urethral longitudinal smooth muscle","volume":"31","author":"Mistry","year":"2020","journal-title":"Int. Urogynecol. J."},{"key":"10.1016\/j.actbio.2024.11.039_bib0132","doi-asserted-by":"crossref","unstructured":"J.O.L. DeLancey, Biomechanics of the Female Pelvic Floor, Sect 1 Princ Pelvic Floor Anat Biomechanics (2016) 13\u201351. https:\/\/doi.org\/10.1016\/b978-0-12-803228-2.00002-7.","DOI":"10.1016\/B978-0-12-803228-2.00002-7"},{"key":"10.1016\/j.actbio.2024.11.039_bib0133","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1196\/annals.1389.034","article-title":"Functional Anatomy of the Female Pelvic Floor","volume":"1101","author":"ASHTON-MILLER","year":"2007","journal-title":"Ann Ny Acad Sci"},{"key":"10.1016\/j.actbio.2024.11.039_bib0134","first-page":"203","article-title":"Intelligent Human Systems Integration","author":"Adem","year":"2017","journal-title":"Adv. Intell. Syst. Comput."},{"key":"10.1016\/j.actbio.2024.11.039_bib0135","doi-asserted-by":"crossref","first-page":"329","DOI":"10.3233\/THC-2012-0675","article-title":"Minipig urethra: a suitable animal model in vitro","volume":"20","author":"Joller","year":"2012","journal-title":"Technol. Heal. Care : Off. J. Eur. Soc. Eng. Med."},{"key":"10.1016\/j.actbio.2024.11.039_bib0136","doi-asserted-by":"crossref","first-page":"967","DOI":"10.1016\/S0021-9290(97)00050-X","article-title":"On the flow through the human female urethra","volume":"30","author":"Bush","year":"1997","journal-title":"J. Biomech."},{"key":"10.1016\/j.actbio.2024.11.039_bib0137","first-page":"237","article-title":"Development of a more clinically relevant bladder and urethral model for catheter testing","volume":"45","author":"Gammie","year":"2021","journal-title":"J. M\u00e9d. Eng. Technol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0138","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1016\/S0022-5347(02)80338-X","article-title":"Prognostic value of urodynamic testing in myelodysplastic patients","volume":"167","author":"McGuire","year":"2002","journal-title":"J. Urol."},{"key":"10.1016\/j.actbio.2024.11.039_bib0139","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1007\/s00192-019-04104-7","article-title":"A structured review on the female urethral anatomy and innervation with an emphasis on the role of the urethral longitudinal smooth muscle","volume":"31","author":"Mistry","year":"2020","journal-title":"Int. Urogynecology J."}],"container-title":["Acta Biomaterialia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1742706124006949?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1742706124006949?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,12,17]],"date-time":"2024-12-17T07:22:58Z","timestamp":1734420178000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1742706124006949"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":139,"alternative-id":["S1742706124006949"],"URL":"https:\/\/doi.org\/10.1016\/j.actbio.2024.11.039","relation":{},"ISSN":["1742-7061"],"issn-type":[{"value":"1742-7061","type":"print"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Magnetoactive elastomer-based dynamic urethral support device for stress urinary incontinence","name":"articletitle","label":"Article Title"},{"value":"Acta Biomaterialia","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.actbio.2024.11.039","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Acta Materialia Inc. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}