{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T23:14:43Z","timestamp":1774307683196,"version":"3.50.1"},"reference-count":44,"publisher":"Elsevier BV","issue":"8-9","license":[{"start":{"date-parts":[[2013,8,1]],"date-time":"2013-08-01T00:00:00Z","timestamp":1375315200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2013,8,1]],"date-time":"2013-08-01T00:00:00Z","timestamp":1375315200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2014,8,1]],"date-time":"2014-08-01T00:00:00Z","timestamp":1406851200000},"content-version":"vor","delay-in-days":365,"URL":"http:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Archives of Cardiovascular Diseases"],"published-print":{"date-parts":[[2013,8]]},"DOI":"10.1016\/j.acvd.2013.04.008","type":"journal-article","created":{"date-parts":[[2013,7,29]],"date-time":"2013-07-29T22:23:26Z","timestamp":1375136606000},"page":"423-432","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":13,"title":["Remote-controlled magnetic pulmonary vein isolation using a new three-dimensional non-fluoroscopic navigation system: A single-centre prospective study"],"prefix":"10.1016","volume":"106","author":[{"given":"Antoine","family":"Da Costa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mouna","family":"Ben H\u2019Dech","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C\u00e9cile","family":"Romeyer-Bouchard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Laurence","family":"Bisch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexis","family":"Gate-Martinet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marie","family":"Levallois","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karl","family":"Isaaz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.acvd.2013.04.008_bib0005","doi-asserted-by":"crossref","first-page":"1509","DOI":"10.1161\/01.CIR.0000121736.16643.11","article-title":"Relationships between sinus rhythm, treatment, and survival in the Atrial Fibrillation Follow-Up Investigation of Rhythm Management (AFFIRM) Study","volume":"109","author":"Corley","year":"2004","journal-title":"Circulation"},{"key":"10.1016\/j.acvd.2013.04.008_bib0010","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1056\/NEJM199809033391003","article-title":"Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins","volume":"339","author":"Haissaguerre","year":"1998","journal-title":"N Engl J Med"},{"key":"10.1016\/j.acvd.2013.04.008_bib0015","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1161\/CIRCEP.108.837294","article-title":"Cost-effectiveness of radiofrequency catheter ablation compared with antiarrhythmic drug therapy for paroxysmal atrial fibrillation","volume":"2","author":"Reynolds","year":"2009","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0020","doi-asserted-by":"crossref","first-page":"191","DOI":"10.7326\/0003-4819-151-3-200908040-00131","article-title":"Systematic review: comparative effectiveness of radiofrequency catheter ablation for atrial fibrillation","volume":"151","author":"Terasawa","year":"2009","journal-title":"Ann Intern Med"},{"key":"10.1016\/j.acvd.2013.04.008_bib0025","doi-asserted-by":"crossref","first-page":"S35","DOI":"10.1046\/j.1540-8167.14.s9.17.x","article-title":"Rhythm versus rate control trials in atrial fibrillation","volume":"14","author":"Wyse","year":"2003","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0030","doi-asserted-by":"crossref","first-page":"3449","DOI":"10.1001\/jama.1985.03360240061035","article-title":"Characteristics and prognosis of lone atrial fibrillation. 30-year follow-up in the Framingham Study","volume":"254","author":"Brand","year":"1985","journal-title":"JAMA"},{"key":"10.1016\/j.acvd.2013.04.008_bib0035","doi-asserted-by":"crossref","first-page":"1973","DOI":"10.1161\/01.CIR.0000118472.77237.FA","article-title":"Analysis of cause-specific mortality in the Atrial Fibrillation Follow-up Investigation of Rhythm Management (AFFIRM) study","volume":"109","author":"Steinberg","year":"2004","journal-title":"Circulation"},{"key":"10.1016\/j.acvd.2013.04.008_bib0040","doi-asserted-by":"crossref","first-page":"1825","DOI":"10.1056\/NEJMoa021328","article-title":"A comparison of rate control and rhythm control in patients with atrial fibrillation","volume":"347","author":"Wyse","year":"2002","journal-title":"N Engl J Med"},{"key":"10.1016\/j.acvd.2013.04.008_bib0045","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.1111\/j.1540-8159.2012.03382.x","article-title":"Catheter ablation utilizing remote magnetic navigation: a review of applications and outcomes","volume":"35","author":"Bradfield","year":"2012","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0050","doi-asserted-by":"crossref","first-page":"1472","DOI":"10.1161\/01.CIR.0000125126.83579.1B","article-title":"Initial experience with remote catheter ablation using a novel magnetic navigation system: magnetic remote catheter ablation","volume":"109","author":"Ernst","year":"2004","journal-title":"Circulation"},{"key":"10.1016\/j.acvd.2013.04.008_bib0055","doi-asserted-by":"crossref","first-page":"2980","DOI":"10.1161\/01.CIR.0000038704.84304.6F","article-title":"Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation","volume":"106","author":"Faddis","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.acvd.2013.04.008_bib0060","doi-asserted-by":"crossref","first-page":"1952","DOI":"10.1016\/j.jacc.2003.07.023","article-title":"Magnetic guidance system for cardiac electrophysiology: a prospective trial of safety and efficacy in humans","volume":"42","author":"Faddis","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0065","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.hrthm.2005.09.017","article-title":"Remote controlled magnetically guided pulmonary vein isolation in canines","volume":"3","author":"Greenberg","year":"2006","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.acvd.2013.04.008_bib0070","doi-asserted-by":"crossref","first-page":"1390","DOI":"10.1016\/j.jacc.2005.11.058","article-title":"Robotic magnetic navigation for atrial fibrillation ablation","volume":"47","author":"Pappone","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0075","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1093\/europace\/eup152","article-title":"Image integration increases efficacy of paroxysmal atrial fibrillation catheter ablation: results from the CartoMerge Italian Registry","volume":"11","author":"Bertaglia","year":"2009","journal-title":"Europace"},{"key":"10.1016\/j.acvd.2013.04.008_bib0080","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.1093\/eurheartj\/ehi834","article-title":"Radiofrequency ablation of arrhythmias guided by non-fluoroscopic catheter location: a prospective randomized trial","volume":"27","author":"Earley","year":"2006","journal-title":"Eur Heart J"},{"key":"10.1016\/j.acvd.2013.04.008_bib0085","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1111\/j.1540-8167.2009.01439.x","article-title":"Effect of electroanatomically guided versus conventional catheter ablation of typical atrial flutter on the fluoroscopy time and resource use: a prospective randomized multicenter study","volume":"20","author":"Hindricks","year":"2009","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0090","doi-asserted-by":"crossref","first-page":"3029","DOI":"10.1093\/eurheartj\/ehn453","article-title":"The impact of image integration on catheter ablation of atrial fibrillation using electroanatomic mapping: a prospective randomized study","volume":"29","author":"Kistler","year":"2008","journal-title":"Eur Heart J"},{"key":"10.1016\/j.acvd.2013.04.008_bib0095","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1111\/j.1540-8167.2006.00594.x","article-title":"The impact of CT image integration into an electroanatomic mapping system on clinical outcomes of catheter ablation of atrial fibrillation","volume":"17","author":"Kistler","year":"2006","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0100","doi-asserted-by":"crossref","first-page":"1415","DOI":"10.1093\/eurheartj\/ehi172","article-title":"Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system","volume":"26","author":"Rotter","year":"2005","journal-title":"Eur Heart J"},{"key":"10.1016\/j.acvd.2013.04.008_bib0105","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1093\/europace\/eur062","article-title":"Visualization of multiple catheters with electroanatomical mapping reduces X-ray exposure during atrial fibrillation ablation","volume":"13","author":"Scaglione","year":"2011","journal-title":"Europace"},{"key":"10.1016\/j.acvd.2013.04.008_bib0110","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1111\/j.1540-8167.2004.03356.x","article-title":"Electroanatomic versus fluoroscopic mapping for catheter ablation procedures: a prospective randomized study","volume":"15","author":"Sporton","year":"2004","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0115","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1093\/europace\/eur271","article-title":"Reduced fluoroscopy exposure during ablation of atrial fibrillation using a novel electroanatomical navigation system: a multicentre experience","volume":"14","author":"Stabile","year":"2012","journal-title":"Europace"},{"key":"10.1016\/j.acvd.2013.04.008_bib0120","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1016\/j.hrthm.2011.12.016","volume":"9","author":"Calkins","year":"2012","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.acvd.2013.04.008_bib0125","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1016\/j.jacc.2007.03.040","article-title":"Obesity is a major determinant of radiation dose in patients undergoing pulmonary vein isolation for atrial fibrillation","volume":"50","author":"Ector","year":"2007","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0130","doi-asserted-by":"crossref","first-page":"3003","DOI":"10.1161\/01.CIR.0000146952.49223.11","article-title":"Radiation exposure during catheter ablation of atrial fibrillation","volume":"110","author":"Lickfett","year":"2004","journal-title":"Circulation"},{"key":"10.1016\/j.acvd.2013.04.008_bib0135","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1046\/j.1460-9592.2003.00034.x","article-title":"Radiation exposure during radiofrequency catheter ablation for atrial fibrillation","volume":"26","author":"Macle","year":"2003","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0140","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.ahj.2008.08.009","article-title":"Cancer risk from professional exposure in staff working in cardiac catheterization laboratory: insights from the National Research Council's Biological Effects of Ionizing Radiation VII Report","volume":"157","author":"Venneri","year":"2009","journal-title":"Am Heart J"},{"key":"10.1016\/j.acvd.2013.04.008_bib0145","doi-asserted-by":"crossref","first-page":"2221","DOI":"10.1016\/j.jacc.2012.02.010","volume":"59","author":"Bashore","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0150","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1161\/CIRCEP.110.942672","article-title":"Remote-controlled magnetic pulmonary vein isolation using a new irrigated-tip catheter in patients with atrial fibrillation","volume":"3","author":"Chun","year":"2010","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0155","doi-asserted-by":"crossref","first-page":"1313","DOI":"10.1111\/j.1540-8159.2008.01183.x","article-title":"Remote magnetic versus manual catheter navigation for ablation of supraventricular tachycardias: a randomized, multicenter trial","volume":"31","author":"Wood","year":"2008","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0160","doi-asserted-by":"crossref","first-page":"1399","DOI":"10.1111\/j.1540-8159.2008.01202.x","article-title":"Impact of remote magnetic catheter navigation on ablation fluoroscopy and procedure time","volume":"31","author":"Kim","year":"2008","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0165","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1016\/j.jacc.2007.05.023","article-title":"Remote magnetic navigation: human experience in pulmonary vein ablation","volume":"50","author":"Di Biase","year":"2007","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0170","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1016\/j.acvd.2009.02.009","article-title":"Robotic magnetic navigation for ablation of human arrhythmias: initial experience","volume":"102","author":"Latcu","year":"2009","journal-title":"Arch Cardiovasc Dis"},{"key":"10.1016\/j.acvd.2013.04.008_bib0175","first-page":"691","article-title":"Robotic navigation and ablation","volume":"58","author":"Malcolme-Lawes","year":"2010","journal-title":"Minerva Cardioangiol"},{"issue":"Suppl. 3","key":"10.1016\/j.acvd.2013.04.008_bib0180","first-page":"iii57","article-title":"Remote navigation systems in electrophysiology","volume":"10","author":"Schmidt","year":"2008","journal-title":"Europace"},{"key":"10.1016\/j.acvd.2013.04.008_bib0185","doi-asserted-by":"crossref","first-page":"1963","DOI":"10.1109\/TBME.2009.2021659","article-title":"An impedance-based catheter positioning system for cardiac mapping and navigation","volume":"56","author":"Jiang","year":"2009","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.acvd.2013.04.008_bib0190","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1111\/j.1540-8167.2010.01853.x","article-title":"Morphologic analysis of left atrial anatomy by magnetic resonance angiography in patients with atrial fibrillation: a large single center experience","volume":"22","author":"Anselmino","year":"2011","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0195","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1093\/europace\/euq107","volume":"12","author":"Caponi","year":"2010","journal-title":"Europace"},{"key":"10.1016\/j.acvd.2013.04.008_bib0200","doi-asserted-by":"crossref","first-page":"2004","DOI":"10.1161\/01.CIR.0000061951.81767.4E","article-title":"Pulmonary vein anatomy in patients undergoing catheter ablation of atrial fibrillation: lessons learned by use of magnetic resonance imaging","volume":"107","author":"Kato","year":"2003","journal-title":"Circulation"},{"key":"10.1016\/j.acvd.2013.04.008_bib0205","doi-asserted-by":"crossref","first-page":"1715","DOI":"10.1093\/europace\/eus169","article-title":"Novel robotic catheter manipulation system integrated with remote magnetic navigation for fully remote ablation of atrial tachyarrhythmias: a two-centre evaluation","volume":"14","author":"Nolker","year":"2012","journal-title":"Europace"},{"key":"10.1016\/j.acvd.2013.04.008_bib0210","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1093\/europace\/euq380","article-title":"Remote magnetic navigation for atrial fibrillation ablation: is \u201cAs Good as Manual\u201d good enough","volume":"13","author":"Burkhardt","year":"2011","journal-title":"Europace"},{"key":"10.1016\/j.acvd.2013.04.008_bib0215","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1161\/CIRCEP.110.957803","article-title":"Remote magnetic navigation with irrigated tip catheter for ablation of paroxysmal atrial fibrillation","volume":"3","author":"Miyazaki","year":"2010","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.acvd.2013.04.008_bib0220","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.hrthm.2010.09.074","article-title":"Irrigated-tip magnetic catheter ablation of AF: a long-term prospective study in 130 patients","volume":"8","author":"Pappone","year":"2011","journal-title":"Heart Rhythm"}],"container-title":["Archives of Cardiovascular Diseases"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1875213613001666?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1875213613001666?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T13:41:22Z","timestamp":1761745282000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1875213613001666"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,8]]},"references-count":44,"journal-issue":{"issue":"8-9","published-print":{"date-parts":[[2013,8]]}},"alternative-id":["S1875213613001666"],"URL":"https:\/\/doi.org\/10.1016\/j.acvd.2013.04.008","relation":{},"ISSN":["1875-2136"],"issn-type":[{"value":"1875-2136","type":"print"}],"subject":[],"published":{"date-parts":[[2013,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Remote-controlled magnetic pulmonary vein isolation using a new three-dimensional non-fluoroscopic navigation system: A single-centre prospective study","name":"articletitle","label":"Article Title"},{"value":"Archives of Cardiovascular Diseases","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.acvd.2013.04.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2013 Elsevier Masson SAS. All rights reserved.","name":"copyright","label":"Copyright"}]}}