{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T00:16:24Z","timestamp":1792714584127,"version":"4.5.0"},"reference-count":54,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,10,18]],"date-time":"2023-10-18T00:00:00Z","timestamp":1697587200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["advancesradonc.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Advances in Radiation Oncology"],"published-print":{"date-parts":[[2024,3]]},"DOI":"10.1016\/j.adro.2023.101392","type":"journal-article","created":{"date-parts":[[2023,10,21]],"date-time":"2023-10-21T11:21:47Z","timestamp":1697887307000},"page":"101392","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"title":["Dosimetric Evaluation and Reproducibility of Breath-hold Plans in Intensity Modulated Proton Therapy: An Initial Clinical Experience"],"prefix":"10.1016","volume":"9","author":[{"given":"Pouya","family":"Sabouri","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jason","family":"Molitoris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maida","family":"Ranjbar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julie","family":"Moreau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"II","given":"Charles B.","family":"Simone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pranshu","family":"Mohindra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katja","family":"Langen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9007-3112","authenticated-orcid":false,"given":"Sina","family":"Mossahebi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.adro.2023.101392_bib0001","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1001\/jamaoncol.2019.4889","article-title":"Comparative effectiveness of proton versus photon therapy as part of concurrent chemoradiotherapy for locally advanced cancer","volume":"6","author":"Baumann","year":"2020","journal-title":"JAMA Oncol"},{"key":"10.1016\/j.adro.2023.101392_bib0002","doi-asserted-by":"crossref","first-page":"1569","DOI":"10.1200\/JCO.19.02503","article-title":"Randomized phase IIB trial of proton beam therapy versus intensity-modulated radiation therapy for locally advanced esophageal cancer","volume":"38","author":"Lin","year":"2020","journal-title":"J Clin Oncol"},{"key":"10.1016\/j.adro.2023.101392_bib0003","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.ijrobp.2016.10.001","article-title":"National cancer database analysis of proton versus photon radiation therapy in non-small cell lung cancer","volume":"97","author":"Higgins","year":"2017","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0004","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.ijrobp.2019.01.076","article-title":"Protons versus photons for unresectable hepatocellular carcinoma: Liver decompensation and overall survival","volume":"105","author":"Sanford","year":"2019","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0005","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1016\/S1470-2045(14)70268-2","article-title":"Charged particle therapy versus photon therapy for paranasal sinus and nasal cavity malignant diseases: A systematic review and meta-analysis","volume":"15","author":"Patel","year":"2014","journal-title":"Lancet Oncol"},{"key":"10.1016\/j.adro.2023.101392_bib0006","doi-asserted-by":"crossref","DOI":"10.1093\/jnci\/djx208","article-title":"Quality of life and patient-reported outcomes following proton radiation therapy: A systematic review","volume":"110","author":"Verma","year":"2018","journal-title":"J Natl Cancer Inst"},{"key":"10.1016\/j.adro.2023.101392_bib0007","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1078\/0939-3889-00217","article-title":"The clinical potential of intensity modulated proton therapy","volume":"14","author":"Lomax","year":"2004","journal-title":"Z Med Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0008","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1118\/1.1350587","article-title":"Intensity modulated proton therapy: A clinical example","volume":"28","author":"Lomax","year":"2001","journal-title":"Med Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0009","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1016\/j.ijrobp.2007.09.014","article-title":"Postoperative spot-scanning proton radiation therapy for chordoma and chondrosarcoma in children and adolescents: Initial experience at paul scherrer institute","volume":"71","author":"Rutz","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0010","doi-asserted-by":"crossref","first-page":"2253","DOI":"10.1088\/0031-9155\/53\/9\/003","article-title":"Quantification of interplay effects of scanned particle beams and moving targets","volume":"53","author":"Bert","year":"2008","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.adro.2023.101392_bib0011","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1016\/j.ijrobp.2013.01.024","article-title":"Motion interplay as a function of patient parameters and spot size in spot scanning proton therapy for lung cancer","volume":"86","author":"Grassberger","year":"2013","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0012","doi-asserted-by":"crossref","first-page":"6004","DOI":"10.1118\/1.4749964","article-title":"Motion mitigation in intensity modulated particle therapy by internal target volumes covering range changes","volume":"39","author":"Graeff","year":"2012","journal-title":"Med Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0013","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1088\/0031-9155\/37\/1\/016","article-title":"Effects of respiratory motion on dose uniformity with a charged particle scanning method","volume":"37","author":"Phillips","year":"1992","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.adro.2023.101392_bib0014","doi-asserted-by":"crossref","first-page":"e383","DOI":"10.1016\/S1470-2045(12)70243-7","article-title":"Real-time tumour tracking in particle therapy: technological developments and future perspectives","volume":"13","author":"Riboldi","year":"2012","journal-title":"Lancet Oncol"},{"key":"10.1016\/j.adro.2023.101392_bib0015","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.3390\/cancers7030829","article-title":"Tumour movement in proton therapy: Solutions and remaining questions: A review","volume":"7","author":"De Ruysscher","year":"2015","journal-title":"Cancers"},{"key":"10.1016\/j.adro.2023.101392_bib0016","doi-asserted-by":"crossref","first-page":"3273","DOI":"10.1118\/1.2756602","article-title":"A respiratory-gated treatment system for proton therapy","volume":"34","author":"Lu","year":"2007","journal-title":"Med Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0017","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/j.ijrobp.2016.09.027","article-title":"Impact of real-time image gating on spot scanning proton therapy for lung tumors: A simulation study","volume":"97","author":"Kanehira","year":"2017","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0018","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/j.radonc.2018.01.019","article-title":"A statistical comparison of motion mitigation performances and robustness of various pencil beam scanned proton systems for liver tumour treatments","volume":"128","author":"Zhang","year":"2018","journal-title":"Radiother Oncol"},{"issue":"Suppl 21","key":"10.1016\/j.adro.2023.101392_bib0019","doi-asserted-by":"crossref","first-page":"S2437","DOI":"10.21037\/jtd.2018.01.155","article-title":"Advances in the use of motion management and image guidance in radiation therapy treatment for lung cancer","volume":"10","author":"Molitoris","year":"2018","journal-title":"J Thorac Dis"},{"key":"10.1016\/j.adro.2023.101392_bib0020","doi-asserted-by":"crossref","first-page":"3874","DOI":"10.1118\/1.2349696","article-title":"The management of respiratory motion in radiation oncology report of AAPM Task Group 76","volume":"33","author":"Keall","year":"2006","journal-title":"Med Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0021","doi-asserted-by":"crossref","DOI":"10.3389\/fonc.2021.621350","article-title":"Enhanced deep-inspiration breath hold superior to high-frequency percussive ventilation for respiratory motion mitigation: A physiology-driven, MRI-guided assessment toward optimized lung cancer treatment with proton therapy","volume":"11","author":"Emert","year":"2021","journal-title":"Front Oncol"},{"key":"10.1016\/j.adro.2023.101392_bib0022","doi-asserted-by":"crossref","first-page":"51","DOI":"10.14338\/IJPT-XX-000XX.1","article-title":"Initial validation of proton dose calculations on SPR images from DECT in treatment planning system","volume":"7","author":"Mossahebi","year":"2020","journal-title":"Int J Part Ther"},{"key":"10.1016\/j.adro.2023.101392_bib0023","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1118\/1.4894702","article-title":"The ANACONDA algorithm for deformable image registration in radiotherapy","volume":"42","author":"Weistrand","year":"2015","journal-title":"Med Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0024","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1016\/j.ijrobp.2014.04.029","article-title":"Involved-node proton therapy in combined modality therapy for Hodgkin lymphoma: Results of a phase 2 study","volume":"89","author":"Hoppe","year":"2014","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0025","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1016\/j.ijrobp.2008.12.048","article-title":"Dosimetric comparison of three different involved nodal irradiation techniques for stage II Hodgkin's lymphoma patients: Conventional radiotherapy, intensity-modulated radiotherapy, and three-dimensional proton radiotherapy","volume":"75","author":"Chera","year":"2009","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0026","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.ijrobp.2017.05.014","article-title":"Consensus guidelines for implementing pencil-beam scanning proton therapy for thoracic malignancies on behalf of the PTCOG thoracic and lymphoma subcommittee","volume":"99","author":"Chang","year":"2017","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0027","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1080\/0284186X.2018.1512153","article-title":"Comparative treatment planning study for mediastinal Hodgkin's lymphoma: Impact on normal tissue dose using deep inspiration breath hold proton and photon therapy","volume":"58","author":"Edvardsson","year":"2019","journal-title":"Acta Oncologica"},{"key":"10.1016\/j.adro.2023.101392_bib0028","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1016\/j.ijrobp.2017.08.023","article-title":"Feasibility of pencil beam scanned intensity modulated proton therapy in breath-hold for locally advanced non-small cell lung cancer","volume":"99","author":"Gorgisyan","year":"2017","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0029","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/j.radonc.2020.09.035","article-title":"Clinical implementation of pencil beam scanning proton therapy for liver cancer with forced deep expiration breath hold","volume":"154","author":"Fracchiolla","year":"2021","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.adro.2023.101392_bib0030","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/j.ejmp.2012.04.006","article-title":"Is abdominal compression useful in lung stereotactic body radiation therapy? A 4DCT and dosimetric lobe-dependent study","volume":"29","author":"Bouilhol","year":"2013","journal-title":"Phys Med"},{"key":"10.1016\/j.adro.2023.101392_bib0031","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.1016\/j.ijrobp.2008.06.1937","article-title":"Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients","volume":"72","author":"Yamamoto","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0032","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/j.ijrobp.2010.05.007","article-title":"Rationale for and preliminary results of proton beam therapy for mediastinal lymphoma","volume":"81","author":"Li","year":"2011","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0033","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.radonc.2008.03.007","article-title":"Can protons improve SBRT for lung lesions? Dosimetric considerations","volume":"88","author":"Georg","year":"2008","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.adro.2023.101392_bib0034","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1016\/j.ijrobp.2008.07.048","article-title":"Dose coverage beyond the gross tumor volume for various stereotactic body radiotherapy planning techniques reporting similar control rates for stage I non\u2013small-cell lung cancer","volume":"72","author":"Arvidson","year":"2008","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0035","doi-asserted-by":"crossref","first-page":"4078","DOI":"10.1118\/1.3438081","article-title":"Stereotactic body radiation therapy: The report of AAPM Task Group 101","volume":"37","author":"Benedict","year":"2010","journal-title":"Med Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0036","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1056\/NEJMoa1209825","article-title":"Risk of ischemic heart disease in women after radiotherapy for breast cancer","volume":"368","author":"Darby","year":"2013","journal-title":"N Engl J Med"},{"key":"10.1016\/j.adro.2023.101392_bib0037","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1016\/j.ijrobp.2007.04.077","article-title":"A nomogram to predict radiation pneumonitis, derived from a combined analysis of RTOG 9311 and institutional data","volume":"69","author":"Bradley","year":"2007","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0038","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1016\/j.radonc.2016.09.012","article-title":"Abdominal organ motion during inhalation and exhalation breath-holds: Pancreatic motion at different lung volumes compared","volume":"121","author":"Lens","year":"2016","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.adro.2023.101392_bib0039","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20160194","article-title":"Safely prolonging single breath-holds to >5 min in patients with cancer: Feasibility and applications for radiotherapy","volume":"89","author":"Parkes","year":"2016","journal-title":"Br J Radiol"},{"key":"10.1016\/j.adro.2023.101392_bib0040","doi-asserted-by":"crossref","first-page":"4332","DOI":"10.1120\/jacmp.v15i1.4332","article-title":"Assessment of tumor motion reproducibility with audio-visual coaching through successive 4D CT sessions","volume":"15","author":"Goossens","year":"2014","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0041","doi-asserted-by":"crossref","first-page":"1665","DOI":"10.1016\/j.ijrobp.2011.02.048","article-title":"Incidence of changes in respiration-induced tumor motion and its relationship with respiratory surrogates during individual treatment fractions","volume":"82","author":"Malinowski","year":"2012","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0042","doi-asserted-by":"crossref","first-page":"1352","DOI":"10.1016\/j.ijrobp.2006.11.025","article-title":"Is a single respiratory correlated 4D-CT study sufficient for evaluation of breathing motion?","volume":"67","author":"Guckenberger","year":"2007","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0043","doi-asserted-by":"crossref","first-page":"1360","DOI":"10.1080\/0284186X.2016.1221532","article-title":"Considerable pancreatic tumor motion during breath-holding","volume":"55","author":"Lens","year":"2016","journal-title":"Acta Oncol"},{"key":"10.1016\/j.adro.2023.101392_bib0044","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.radonc.2018.07.007","article-title":"Intra-breath-hold residual motion of image-guided DIBH liver-SBRT: An estimation by ultrasound-based monitoring correlated with diaphragm position in CBCT","volume":"129","author":"Vogel","year":"2018","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.adro.2023.101392_bib0045","doi-asserted-by":"crossref","first-page":"4137","DOI":"10.1088\/0031-9155\/58\/12\/4137","article-title":"Interplay effects in proton scanning for lung: A 4D Monte Carlo study assessing the impact of tumor and beam delivery parameters","volume":"58","author":"Dowdell","year":"2013","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.adro.2023.101392_bib0046","doi-asserted-by":"crossref","first-page":"e50","DOI":"10.1002\/mp.15470","article-title":"AAPM Task Group Report 290: Respiratory motion management for particle therapy","volume":"49","author":"Li","year":"2022","journal-title":"Med Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0047","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.radonc.2022.10.003","article-title":"Systematic review for deep inspiration breath hold in proton therapy for mediastinal lymphoma: A PTCOG Lymphoma Subcommittee report and recommendations","volume":"177","author":"Patel","year":"2022","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.adro.2023.101392_bib0048","doi-asserted-by":"crossref","first-page":"4840","DOI":"10.1118\/1.4923171","article-title":"Selective robust optimization: A new intensity-modulated proton therapy optimization strategy","volume":"42","author":"Li","year":"2015","journal-title":"Med Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0049","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/abcbcf","article-title":"Validation of a CT-based motion model with in-situ fluoroscopy for lung surface deformation estimation","volume":"66","author":"Ranjbar","year":"2021","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.adro.2023.101392_bib0050","doi-asserted-by":"crossref","first-page":"5407","DOI":"10.1002\/mp.13824","article-title":"Development and prospective in-patient proof-of-concept validation of a surface photogrammetry+ CT-based volumetric motion model for lung radiotherapy","volume":"46","author":"Ranjbar","year":"2019","journal-title":"Med Phys"},{"issue":"6 Part 1","key":"10.1016\/j.adro.2023.101392_bib0051","doi-asserted-by":"crossref","first-page":"3157","DOI":"10.1118\/1.3589131","article-title":"Correlation of respiratory motion between external patient surface and internal anatomical landmarks","volume":"38","author":"Fayad","year":"2011","journal-title":"Med Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0052","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1118\/1.3250856","article-title":"Respiratory motion management in particle therapy","volume":"37","author":"Rietzel","year":"2010","journal-title":"Med Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0053","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.1016\/j.ijrobp.2004.07.718","article-title":"Reproducibility of organ position using voluntary breath-hold method with spirometer for extracranial stereotactic radiotherapy","volume":"60","author":"Kimura","year":"2004","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.adro.2023.101392_bib0054","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1007\/s00330-005-2795-9","article-title":"Assessment of reproducibility and stability of different breath-hold maneuvres by dynamic MRI: Comparison between healthy adults and patients with pulmonary hypertension","volume":"16","author":"Plathow","year":"2006","journal-title":"Eur Radiol"}],"container-title":["Advances in Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2452109423002208?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2452109423002208?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T15:44:01Z","timestamp":1762530241000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2452109423002208"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3]]},"references-count":54,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,3]]}},"alternative-id":["S2452109423002208"],"URL":"https:\/\/doi.org\/10.1016\/j.adro.2023.101392","relation":{},"ISSN":["2452-1094"],"issn-type":[{"value":"2452-1094","type":"print"}],"subject":[],"published":{"date-parts":[[2024,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Dosimetric Evaluation and Reproducibility of Breath-hold Plans in Intensity Modulated Proton Therapy: An Initial Clinical Experience","name":"articletitle","label":"Article Title"},{"value":"Advances in Radiation Oncology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.adro.2023.101392","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Published by Elsevier Inc. on behalf of American Society for Radiation Oncology.","name":"copyright","label":"Copyright"}],"article-number":"101392"}}