{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T21:22:06Z","timestamp":1792790526255,"version":"4.5.0"},"reference-count":23,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T00:00:00Z","timestamp":1762905600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100015696","name":"Siemens Healthineers USA","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100015696","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["advancesradonc.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Advances in Radiation Oncology"],"published-print":{"date-parts":[[2026,2]]},"DOI":"10.1016\/j.adro.2025.101957","type":"journal-article","created":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T14:27:26Z","timestamp":1763648846000},"page":"101957","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Accuracy of Photon Dose Calculation on Photon-Counting Computed Tomography\u2014A Comparison Study Based on Virtual Monoenergetic and Electron Density (Rho) Images for Pancreatic Cases"],"prefix":"10.1016","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1108-7626","authenticated-orcid":false,"given":"Xin","family":"Wu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Wohlfahrt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jainil","family":"Shah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ludovica","family":"Lofino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manisha","family":"Palta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiuwen","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Q. Jackie","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Sheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.adro.2025.101957_bib0001","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2023.110829","article-title":"Photon-counting CT: Review of initial clinical results","volume":"163","author":"van der Bie","year":"2023","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.adro.2025.101957_bib0002","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1148\/radiol.212579","article-title":"First clinical photon-counting detector CT system: Technical evaluation","volume":"303","author":"Rajendran","year":"2022","journal-title":"Radiology"},{"key":"10.1016\/j.adro.2025.101957_bib0003","doi-asserted-by":"crossref","first-page":"2461","DOI":"10.1007\/s00330-022-09278-1","article-title":"Initial experience on abdominal photon-counting computed tomography in clinical routine: General image quality and dose exposure","volume":"33","author":"Becker","year":"2023","journal-title":"Eur Radiol"},{"key":"10.1016\/j.adro.2025.101957_bib0004","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.ejmp.2020.10.030","article-title":"Photon-counting CT review","volume":"79","author":"Flohr","year":"2020","journal-title":"Phys Med"},{"key":"10.1016\/j.adro.2025.101957_bib0005","first-page":"363","article-title":"Cardiovascular applications of photon-counting CT technology: A revolutionary new diagnostic step","volume":"10","author":"Meloni","year":"2023","journal-title":"J Cardiovasc Dev Dis"},{"key":"10.1016\/j.adro.2025.101957_bib0006","doi-asserted-by":"crossref","first-page":"3626","DOI":"10.3390\/jcm12113626","article-title":"Dual source photon-counting computed tomography\u2014part II: Clinical overview of neurovascular applications","volume":"12","author":"Cademartiri","year":"2023","journal-title":"J Clin Med"},{"key":"10.1016\/j.adro.2025.101957_bib0007","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1177\/15910199231175198","article-title":"High-resolution computed tomography angiography of the orbit using a photon-counting computed tomography scanner","volume":"31","author":"Farnsworth","year":"2025","journal-title":"Interv Neuroradiol"},{"key":"10.1016\/j.adro.2025.101957_bib0008","doi-asserted-by":"crossref","DOI":"10.2214\/AJR.23.29950","article-title":"Photon-counting detector CT versus energy-integrating detector CT of the lumbar spine: Comparison of radiation dose and image quality","volume":"222","author":"Marth","year":"2024","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.adro.2025.101957_bib0009","doi-asserted-by":"crossref","first-page":"894","DOI":"10.1093\/bjr\/tqae058","article-title":"High yield clinical applications for photon counting CT in neurovascular imaging","volume":"97","author":"Madhavan","year":"2024","journal-title":"Br J Radiol"},{"key":"10.1016\/j.adro.2025.101957_bib0010","doi-asserted-by":"crossref","DOI":"10.1002\/acm2.14069","article-title":"A methodology for incorporating a photon-counting CT system into routine clinical use","volume":"24","author":"Bache","year":"2023","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.adro.2025.101957_bib0011","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ab1af1","article-title":"The potential of photon-counting CT for quantitative contrast-enhanced imaging in radiotherapy","volume":"64","author":"Simard","year":"2019","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.adro.2025.101957_bib0012","doi-asserted-by":"crossref","DOI":"10.3389\/fonc.2022.970299","article-title":"Assessment of quantitative information for radiation therapy at a first-generation clinical photon-counting computed tomography scanner","volume":"12","author":"Hu","year":"2022","journal-title":"Front Oncol"},{"key":"10.1016\/j.adro.2025.101957_bib0013","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1016\/j.clinimag.2023.08.004","article-title":"Virtual monoenergetic imaging in photon-counting CT of the head and neck","volume":"102","author":"Farhadi","year":"2023","journal-title":"Clin Imaging"},{"key":"10.1016\/j.adro.2025.101957_bib0014","series-title":"Spectral Imaging. Medical Radiology","first-page":"333","article-title":"Dual-energy CT in radiation oncology","author":"Richter","year":"2022"},{"key":"10.1016\/j.adro.2025.101957_bib0015","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1186\/1748-717X-9-168","article-title":"Radiotherapy treatment planning with contrast-enhanced computed tomography: Feasibility of dual-energy virtual unenhanced imaging for improved dose calculations","volume":"9","author":"Yamada","year":"2014","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.adro.2025.101957_bib0016","series-title":"Spectral Imaging: Dual-Energy, Multi-Energy and Photon-Counting CT","author":"Alkadhi","year":"2022"},{"key":"10.1016\/j.adro.2025.101957_bib0017","doi-asserted-by":"crossref","first-page":"2579","DOI":"10.1007\/s00261-017-1151-2","article-title":"Assessment of 70-keV virtual monoenergetic spectral images in abdominal CT imaging: A comparison study to conventional polychromatic 120-kVp images","volume":"42","author":"Rassouli","year":"2017","journal-title":"Abdom Radiol (NY)"},{"key":"10.1016\/j.adro.2025.101957_bib0018","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1007\/s11604-021-01233-2","article-title":"Dual-energy CT: Minimal essentials for radiologists","volume":"40","author":"Tatsugami","year":"2022","journal-title":"Jpn J Radiol"},{"key":"10.1016\/j.adro.2025.101957_bib0019","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.1007\/s11604-025-01823-4","article-title":"Contrast medium dose optimization in the era of multi-energy CT","volume":"43","author":"Nagayama","year":"2025","journal-title":"Jpn J Radiol"},{"key":"10.1016\/j.adro.2025.101957_bib0020","doi-asserted-by":"crossref","DOI":"10.1016\/j.radonc.2023.109675","article-title":"Consensus guide on CT-based prediction of stopping-power ratio using a Hounsfield look-up table for proton therapy","volume":"184","author":"Peters","year":"2023","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.adro.2025.101957_bib0021","doi-asserted-by":"crossref","first-page":"68","DOI":"10.3389\/frai.2020.00068","article-title":"Fluence map prediction using deep learning models\u2014Direct plan generation for pancreas stereotactic body radiation therapy","volume":"3","author":"Wang","year":"2020","journal-title":"Front Artif Intell"},{"key":"10.1016\/j.adro.2025.101957_bib0022","doi-asserted-by":"crossref","first-page":"3149","DOI":"10.1118\/1.2241992","article-title":"Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution\/superposition, and pencil beam computations","volume":"33","author":"Vanderstraeten","year":"2006","journal-title":"Med Phys"},{"key":"10.1016\/j.adro.2025.101957_bib0023","first-page":"tqae226","article-title":"A review of applications of photon-counting computed tomography in head and neck imaging","author":"Dogra","year":"2024","journal-title":"Br J Radiol"}],"container-title":["Advances in Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2452109425002441?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2452109425002441?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T11:23:30Z","timestamp":1770981810000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2452109425002441"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2]]},"references-count":23,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["S2452109425002441"],"URL":"https:\/\/doi.org\/10.1016\/j.adro.2025.101957","relation":{},"ISSN":["2452-1094"],"issn-type":[{"value":"2452-1094","type":"print"}],"subject":[],"published":{"date-parts":[[2026,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Accuracy of Photon Dose Calculation on Photon-Counting Computed Tomography\u2014A Comparison Study Based on Virtual Monoenergetic and Electron Density (Rho) Images for Pancreatic Cases","name":"articletitle","label":"Article Title"},{"value":"Advances in Radiation Oncology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.adro.2025.101957","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Author(s). Published by Elsevier Inc. on behalf of American Society for Radiation Oncology.","name":"copyright","label":"Copyright"}],"article-number":"101957"}}