{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,16]],"date-time":"2026-04-16T20:28:20Z","timestamp":1776371300009,"version":"3.51.2"},"reference-count":34,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2005,4,1]],"date-time":"2005-04-01T00:00:00Z","timestamp":1112313600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["American Heart Journal"],"published-print":{"date-parts":[[2005,4]]},"DOI":"10.1016\/j.ahj.2004.07.011","type":"journal-article","created":{"date-parts":[[2005,4,9]],"date-time":"2005-04-09T11:46:04Z","timestamp":1113047164000},"page":"681-688","source":"Crossref","is-referenced-by-count":18,"title":["Prospective randomized comparison of early and late results of a carbonized stent versus a high-grade stainless steel stent of identical design: The Prevention of Recurrent Venous Thromboembolism (PREVENT) trial"],"prefix":"10.1016","volume":"149","author":[{"given":"Peter B.","family":"Sick","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oana","family":"Brosteanu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthias","family":"Ulrich","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Holger","family":"Thiele","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Josef","family":"Niebauer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ingmar","family":"Busch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerhard","family":"Schuler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ahj.2004.07.011_bib1","doi-asserted-by":"crossref","first-page":"1591","DOI":"10.1055\/s-0038-1649987","article-title":"Fast and reproducible vascular neointima formation in the hamster carotid artery: effects of trapidil and captopril","volume":"74","author":"Matsuno","year":"1995","journal-title":"Thromb. Haemost."},{"key":"10.1016\/j.ahj.2004.07.011_bib2","doi-asserted-by":"crossref","first-page":"2710","DOI":"10.1161\/01.CIR.90.6.2710","volume":"90","author":"Maresta","year":"1994","journal-title":"Circulation"},{"key":"10.1016\/j.ahj.2004.07.011_bib3","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1056\/NEJM199408253310801","article-title":"A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group","volume":"331","author":"Serruys","year":"1994","journal-title":"N. Engl. J. Med."},{"key":"10.1016\/j.ahj.2004.07.011_bib4","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1056\/NEJM199408253310802","article-title":"A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators","volume":"331","author":"Fischman","year":"1994","journal-title":"N. Engl. J. Med."},{"key":"10.1016\/j.ahj.2004.07.011_bib5","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/S0002-8703(03)00113-3","article-title":"Prospective randomized comparison of early and late results of 4 different stent designs","volume":"146","author":"Sick","year":"2003","journal-title":"Am. Heart J."},{"key":"10.1016\/j.ahj.2004.07.011_bib6","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1080\/089419399272520","article-title":"Diamond-like carbon coating and plasma or glow discharge treatment of mechanical heart valves","volume":"12","author":"Tran","year":"1999","journal-title":"J. Invest. Surg."},{"key":"10.1016\/j.ahj.2004.07.011_bib7","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1002\/ccd.10249","article-title":"Stent design\u2013related coronary artery remodeling and patterns of neointima formation following self-expanding and balloon-expandable stent implantation","volume":"56","author":"Konig","year":"2002","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"10.1016\/j.ahj.2004.07.011_bib8","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1016\/S0049-3848(00)00295-4","article-title":"In vitro analyses of diamond-like carbon coated stents. Reduction of metal ion release, platelet activation, and thrombogenicity","volume":"99","author":"Gutensohn","year":"2000","journal-title":"Thromb. Res."},{"key":"10.1016\/j.ahj.2004.07.011_bib9","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1002\/(SICI)1097-0304(199601)37:1<14::AID-CCD5>3.0.CO;2-7","article-title":"Comparison of different quantitative coronary analysis systems: ARTREK, CAAS, and CMS","volume":"37","author":"Hausleiter","year":"1996","journal-title":"Catheter. Cardiovasc. Diagn."},{"key":"10.1016\/j.ahj.2004.07.011_bib10","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1002\/ccd.1810350205","article-title":"Alterations in reference vessel diameter following intracoronary stent implantation: important consequences for restenosis based on percent diameter stenosis","volume":"35","author":"Foley","year":"1995","journal-title":"Catheter. Cardiovasc. Diagn."},{"key":"10.1016\/j.ahj.2004.07.011_bib11","doi-asserted-by":"crossref","first-page":"1000","DOI":"10.1007\/s003920050142","article-title":"[Comparative studies of the rate of restenosis after implantation of Palmaz-Schatz and AVE-Micro stents]","volume":"86","author":"Sick","year":"1997","journal-title":"Z. Kardiol."},{"key":"10.1016\/j.ahj.2004.07.011_bib12","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1056\/NEJMoa012843","article-title":"A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization","volume":"346","author":"Morice","year":"2002","journal-title":"N. Engl. J. Med."},{"key":"10.1016\/j.ahj.2004.07.011_bib13","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1080\/14628840050516181","article-title":"Clinical and angiographic results with the ACS MULTI-LINK DUET trade mark Coronary Stent System\u2014the DUET Study","volume":"3","author":"Te Riele","year":"2000","journal-title":"Int. J. Cardiovasc. Intervent."},{"key":"10.1016\/j.ahj.2004.07.011_bib14","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1536\/jhj.42.409","article-title":"Angiographic and clinical follow-up after coronary implantation of the ACS Multilink Duet stent: a single center experience","volume":"42","author":"Sayin","year":"2001","journal-title":"Jpn. Heart J."},{"key":"10.1016\/j.ahj.2004.07.011_bib15","doi-asserted-by":"crossref","first-page":"1299","DOI":"10.1001\/jama.1996.03530410011004","article-title":"New ideas on pathology of restenosis","volume":"275","author":"Phillips","year":"1996","journal-title":"JAMA"},{"key":"10.1016\/j.ahj.2004.07.011_bib16","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1007\/978-1-4615-5959-7_16","article-title":"Compensatory enlargement, remodeling, and restenosis","volume":"430","author":"Keren","year":"1997","journal-title":"Adv. Exp. Med. Biol."},{"key":"10.1016\/j.ahj.2004.07.011_bib17","doi-asserted-by":"crossref","first-page":"1895","DOI":"10.1016\/S0140-6736(00)03262-1","article-title":"Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis","volume":"356","author":"Koster","year":"2000","journal-title":"Lancet"},{"key":"10.1016\/j.ahj.2004.07.011_bib18","first-page":"309","article-title":"Restenosis after coronary angioplasty: its pathogenesis and prevention","volume":"36","author":"Marzocchi","year":"1991","journal-title":"Cardiologia"},{"key":"10.1016\/j.ahj.2004.07.011_bib19","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1097\/00045415-199907000-00014","article-title":"Prevention of coronary restenosis","volume":"7","author":"Casterella","year":"1999","journal-title":"Cardiol. Rev."},{"key":"10.1016\/j.ahj.2004.07.011_bib20","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1002\/(SICI)1097-0320(19990215)38:1<30::AID-CYTO5>3.0.CO;2-5","article-title":"Rapid in vitro biocompatibility assay of endovascular stents by flow cytometry using platelet activation and platelet-leukocyte aggregation","volume":"38","author":"Tarnok","year":"1999","journal-title":"Cytometry"},{"key":"10.1016\/j.ahj.2004.07.011_bib21","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1161\/01.CIR.103.3.429","article-title":"Gold-coated NIR stents in porcine coronary arteries","volume":"103","author":"Edelman","year":"2001","journal-title":"Circulation"},{"key":"10.1016\/j.ahj.2004.07.011_bib22","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1097\/00004424-199507000-00004","article-title":"Experimental arterial stent placement. Comparison of a new Nitinol stent and Wallstent","volume":"30","author":"Schurmann","year":"1995","journal-title":"Invest. Radiol."},{"key":"10.1016\/j.ahj.2004.07.011_bib23","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1148\/radiology.203.1.9122416","article-title":"Iliac arteries: plain and heparin-coated Dacron-covered stent-grafts compared with noncovered metal stents\u2014an experimental study","volume":"203","author":"Schurmann","year":"1997","journal-title":"Radiology"},{"key":"10.1016\/j.ahj.2004.07.011_bib24","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1002\/(SICI)1097-0304(199705)41:1<71::AID-CCD17>3.0.CO;2-T","article-title":"Coronary implantation of silicone-carbide\u2013coated Palmaz-Schatz stents in patients with high risk of stent thrombosis without oral anticoagulation","volume":"41","author":"Ozbek","year":"1997","journal-title":"Catheter. Cardiovasc. Diagn."},{"key":"10.1016\/j.ahj.2004.07.011_bib25","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/0142-9612(88)90075-0","article-title":"Tissue reaction to fabrics coated with turbostratic carbon: subcutaneous versus vascular implants","volume":"9","author":"Aebischer","year":"1988","journal-title":"Biomaterials"},{"key":"10.1016\/j.ahj.2004.07.011_bib26","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1177\/039139889101400807","article-title":"Pyrolytic carbon coating enhances Teflon and Dacron fabric compatibility with endothelial cell growth","volume":"14","author":"Sbarbati","year":"1991","journal-title":"Int. J. Artif. Organs"},{"key":"10.1016\/j.ahj.2004.07.011_bib27","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/0272-8842(93)90038-S","article-title":"Carbofilm: present and future applications in biomedical devices","volume":"19","author":"Vallana","year":"1993","journal-title":"Ceram. Int."},{"key":"10.1016\/j.ahj.2004.07.011_bib28","doi-asserted-by":"crossref","first-page":"1949","DOI":"10.1056\/NEJM199912233412601","article-title":"Coronary angioplasty with or without stent implantation for acute myocardial infarction. Stent Primary Angioplasty in Myocardial Infarction Study Group","volume":"341","author":"Grines","year":"1999","journal-title":"N. Engl. J. Med."},{"key":"10.1016\/j.ahj.2004.07.011_bib29","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1016\/0142-9612(95)94903-X","article-title":"Platelet and coagulation factor variations induced in vitro by polyethylene terephthalate (Dacron) coated with pyrolytic carbon","volume":"16","author":"Cenni","year":"1995","journal-title":"Biomaterials"},{"key":"10.1016\/j.ahj.2004.07.011_bib30","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1016\/j.amjcard.2004.02.029","article-title":"Comparison of early and late results of a Carbofilm-coated stent versus a pure high-grade stainless steel stent (the Carbostent-Trial)","volume":"93","author":"Sick","year":"2004","journal-title":"Am. J. Cardiol."},{"key":"10.1016\/j.ahj.2004.07.011_bib31","first-page":"562","article-title":"Comparison of stainless steel stents coated with turbostratic carbon and uncoated stents for percutaneous coronary interventions","volume":"15","author":"Haase","year":"2003","journal-title":"J. Invasive Cardiol."},{"key":"10.1016\/j.ahj.2004.07.011_bib32","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1016\/S0735-1097(98)00076-X","article-title":"Predictors of restenosis after coronary stent implantation","volume":"31","author":"Bauters","year":"1998","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.ahj.2004.07.011_bib33","doi-asserted-by":"crossref","first-page":"1428","DOI":"10.1016\/S0735-1097(97)00334-3","article-title":"Predictive factors of restenosis after coronary stent placement","volume":"30","author":"Kastrati","year":"1997","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.ahj.2004.07.011_bib34","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1056\/NEJMoa012843","article-title":"A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization","volume":"346","author":"Morice","year":"2002","journal-title":"N. Engl. J. Med."}],"updated-by":[{"DOI":"10.1016\/j.ahj.2005.05.016","type":"erratum","label":"Erratum","source":"publisher","updated":{"date-parts":[[2005,6,1]],"date-time":"2005-06-01T00:00:00Z","timestamp":1117584000000}}],"container-title":["American Heart Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002870304004466?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002870304004466?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,2,10]],"date-time":"2019-02-10T13:32:58Z","timestamp":1549805578000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002870304004466"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,4]]},"references-count":34,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2005,4]]}},"alternative-id":["S0002870304004466"],"URL":"https:\/\/doi.org\/10.1016\/j.ahj.2004.07.011","relation":{},"ISSN":["0002-8703"],"issn-type":[{"value":"0002-8703","type":"print"}],"subject":[],"published":{"date-parts":[[2005,4]]}}}