{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T16:48:34Z","timestamp":1791046114437,"version":"4.1.0"},"reference-count":19,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2006,1,1]],"date-time":"2006-01-01T00:00:00Z","timestamp":1136073600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2006,1,1]],"date-time":"2006-01-01T00:00:00Z","timestamp":1136073600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Heart Journal"],"published-print":{"date-parts":[[2006,1]]},"DOI":"10.1016\/j.ahj.2005.02.046","type":"journal-article","created":{"date-parts":[[2005,12,22]],"date-time":"2005-12-22T18:08:02Z","timestamp":1135274882000},"page":"131-138","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":31,"title":["Real-time myocardial perfusion imaging for pharmacologic stress testing: Added value to single photon emission computed tomography"],"prefix":"10.1016","volume":"151","author":[{"given":"Grigorios","family":"Korosoglou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alain-Eric","family":"Dubart","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"Jr","given":"K. Gaspar C.","family":"DaSilva","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nino","family":"Labadze","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Hardt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Hansen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raffi","family":"Bekeredjian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Zugck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joerg","family":"Zehelein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hugo A.","family":"Katus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Helmut","family":"Kuecherer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ahj.2005.02.046_bib1","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1161\/01.CIR.97.5.473","article-title":"Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion","volume":"97","author":"Wei","year":"1998","journal-title":"Circulation"},{"key":"10.1016\/j.ahj.2005.02.046_bib2","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1161\/01.CIR.96.3.785","article-title":"Detection of coronary artery disease with myocardial contrast echocardiography: comparison with 99mTc-sestamibi single-photon emission computed tomography","volume":"96","author":"Kaul","year":"1997","journal-title":"Circulation"},{"key":"10.1016\/j.ahj.2005.02.046_bib3","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1161\/01.CIR.102.1.55","article-title":"Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosin stress: comparison with 99m Tc-sestamibi SPECT imaging","volume":"102","author":"Heinle","year":"2000","journal-title":"Circulation"},{"key":"10.1016\/j.ahj.2005.02.046_bib4","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.1016\/j.ahj.2003.12.030","article-title":"Myocardial perfusion assessment in patients with medium probability of coronary artery disease and no prior myocardial infarction: comparison of myocardial contrast echocardiography with 99m Tc single-photon emission computed tomography","volume":"147","author":"Senior","year":"2004","journal-title":"Am Heart J"},{"key":"10.1016\/j.ahj.2005.02.046_bib5","doi-asserted-by":"crossref","first-page":"1293","DOI":"10.1016\/S0002-9149(03)00316-3","article-title":"Comparison of usefulness of dipyridamole stress myocardial contrast echocardiography to technetium-99m sestamibi single-photon emission computed tomography for detection of coronary artery disease (PB127 Multicenter Phase 2 Trial results)","volume":"91","author":"Wei","year":"2003","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.ahj.2005.02.046_bib6","series-title":"Contrast agents for echocardiography: principles and instrumentation","first-page":"20","year":"2000"},{"key":"10.1016\/j.ahj.2005.02.046_bib7","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1016\/S0002-9149(02)02512-2","article-title":"Comparison of real-time coherent contrast imaging to dipyridamole thallium-201 single-photon emission computed tomography for assessment of myocardial perfusion and left ventricular wall motion","volume":"90","author":"Oraby","year":"2002","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.ahj.2005.02.046_bib8","doi-asserted-by":"crossref","first-page":"1807","DOI":"10.1016\/j.jacc.2003.09.073","article-title":"Incremental value of parametric quantitative assessment of myocardial perfusion by triggered low-power myocardial contrast echocardiography","volume":"43","author":"Yu","year":"2004","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ahj.2005.02.046_bib9","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.jacc.2003.07.040","article-title":"Assessment of the physiologic significance of coronary disease with dipyridamole real-time myocardial contrast echocardiography. Comparison with technetium-99m sestamibi single-photon emission computed tomography and quantitative coronary angiography","volume":"43","author":"Peltier","year":"2004","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ahj.2005.02.046_bib10","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1016\/S0735-1097(00)01179-7","article-title":"Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: comparison with single photon emission computed tomography","volume":"37","author":"Shimoni","year":"2001","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ahj.2005.02.046_bib11","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.amjcard.2004.05.018","article-title":"Comparison of real-time myocardial contrast echocardiography for the assessment of myocardial viability with 18fluordeoxyglucose positron emission tomography and dobutamine stress echocardiography","volume":"94","author":"Korosoglou","year":"2004","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.ahj.2005.02.046_bib12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.amjcard.2004.07.104","article-title":"Usefulness of real-time myocardial perfusion imaging in the evaluation of patients with first time chest pain","volume":"94","author":"Korosoglou","year":"2004","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.ahj.2005.02.046_bib13","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.echo.2003.08.004","article-title":"Real-time myocardial contrast echocardiography for pharmacologic stress testing: is quantitative estimation of myocardial blood flow reserve necessary?","volume":"17","author":"Korosoglou","year":"2004","journal-title":"J Am Soc Echocardiogr"},{"key":"10.1016\/j.ahj.2005.02.046_bib14","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1038\/clpt.1981.18","article-title":"Clinical biostatistics: the biostatistics of concordance","volume":"29","author":"Kramer","year":"1981","journal-title":"Clin Pharmacol Ther"},{"key":"10.1016\/j.ahj.2005.02.046_bib15","doi-asserted-by":"crossref","first-page":"1550","DOI":"10.1161\/hc3801.095694","article-title":"Comparison of real-time and intermittent triggered myocardial contrast echocardiography for quantification of coronary stenosis severity and transmural perfusion gradient","volume":"104","author":"Masugata","year":"2001","journal-title":"Circulation"},{"key":"10.1016\/j.ahj.2005.02.046_bib16","doi-asserted-by":"crossref","first-page":"1010","DOI":"10.1067\/mje.2001.112908","article-title":"Accuracy and reproducibility of coronary flow rate assessment by real-time contrast echocardiography: in vitro and in vivo studies","volume":"14","author":"Lafitte","year":"2001","journal-title":"J Am Soc Echocardiogr"},{"key":"10.1016\/j.ahj.2005.02.046_bib17","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/S0735-1097(99)00231-4","article-title":"Comparison of stress\/rest myocardial perfusion tomography, dipyridamole and dobutamine stress echocardiography for the detection of coronary disease in hypertensive patients with chest pain and positive exercise test","volume":"34","author":"Fragasso","year":"1999","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ahj.2005.02.046_bib18","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1016\/S0735-1097(00)01204-3","article-title":"Real-time perfusion imaging with low mechanical index pulse inversion Doppler imaging","volume":"37","author":"Porter","year":"2001","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ahj.2005.02.046_bib19","doi-asserted-by":"crossref","first-page":"1108","DOI":"10.1161\/01.CIR.0000139905.47128.9F","article-title":"Incremental benefit of myocardial contrast to combined dipyridamole-exercise stress echocardiography for the assessment of coronary artery disease","volume":"110","author":"Moir","year":"2004","journal-title":"Circulation"}],"container-title":["American Heart Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002870305003285?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002870305003285?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T05:17:18Z","timestamp":1757567838000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002870305003285"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,1]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2006,1]]}},"alternative-id":["S0002870305003285"],"URL":"https:\/\/doi.org\/10.1016\/j.ahj.2005.02.046","relation":{},"ISSN":["0002-8703"],"issn-type":[{"value":"0002-8703","type":"print"}],"subject":[],"published":{"date-parts":[[2006,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Real-time myocardial perfusion imaging for pharmacologic stress testing: Added value to single photon emission computed tomography","name":"articletitle","label":"Article Title"},{"value":"American Heart Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ahj.2005.02.046","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2005 Mosby, Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}