{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T17:44:22Z","timestamp":1771263862693,"version":"3.50.1"},"reference-count":21,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2012,3,1]],"date-time":"2012-03-01T00:00:00Z","timestamp":1330560000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2012,3,1]],"date-time":"2012-03-01T00:00:00Z","timestamp":1330560000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Heart Journal"],"published-print":{"date-parts":[[2012,3]]},"DOI":"10.1016\/j.ahj.2011.12.009","type":"journal-article","created":{"date-parts":[[2012,3,16]],"date-time":"2012-03-16T12:14:16Z","timestamp":1331900056000},"page":"492-499","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":105,"title":["Safety of a conservative strategy of permanent pacemaker implantation after transcatheter aortic CoreValve implantation"],"prefix":"10.1016","volume":"163","author":[{"given":"Marco","family":"De Carlo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cristina","family":"Giannini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesco","family":"Bedogni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Silvio","family":"Klugmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nedy","family":"Brambilla","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Federico","family":"De Marco","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giulio","family":"Zucchelli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luca","family":"Testa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jacopo","family":"Oreglia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anna Sonia","family":"Petronio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ahj.2011.12.009_bb0005","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1016\/S0735-1097(02)02926-1","article-title":"Development and validation of a simple risk score to predict the need for permanent pacing after cardiac valve surgery","volume":"41","author":"Koplan","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ahj.2011.12.009_bb0010","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1111\/j.1540-8191.2006.00216.x","article-title":"Risk factors for requirement of permanent pacemaker implantation after aortic valve replacement","volume":"21","author":"Erdogan","year":"2006","journal-title":"J Card Surg"},{"key":"10.1016\/j.ahj.2011.12.009_bb0015","doi-asserted-by":"crossref","first-page":"3006","DOI":"10.1161\/01.CIR.0000047200.36165.B8","article-title":"Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description","volume":"106","author":"Cribier","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.ahj.2011.12.009_bb0020","first-page":"465","article-title":"First report on a human percutaneous transluminal implantation of a self-expanding valve prosthesis for interventional treatment of aortic valve stenosis","volume":"66","author":"Grube","year":"2005","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.ahj.2011.12.009_bb0025","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/j.jcin.2008.04.007","article-title":"Early and persistent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve","volume":"1","author":"Piazza","year":"2008","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.ahj.2011.12.009_bb0030","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1161\/CIRCINTERVENTIONS.109.930453","article-title":"Safety and efficacy of the subclavian approach for transcatheter aortic valve implantation with the CoreValve revalving system","volume":"3","author":"Petronio","year":"2010","journal-title":"Circ Cardiovasc Interv"},{"key":"10.1016\/j.ahj.2011.12.009_bb0035","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1016\/j.jcin.2010.01.017","article-title":"Predictors for new-onset complete heart block after transcatheter aortic valve implantation","volume":"3","author":"Bleiziffer","year":"2010","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.ahj.2011.12.009_bb0040","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1016\/j.amjcard.2010.07.012","article-title":"Incidence and predictors of atrioventricular conduction impairment after transcatheter aortic valve implantation","volume":"106","author":"Roten","year":"2010","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.ahj.2011.12.009_bb0045","first-page":"431","article-title":"\u201cDevice landing zone\u201d calcification, assessed by MSCT, as a predictive factor for pacemaker implantation after TAVI","volume":"76","author":"Latsios","year":"2010","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.ahj.2011.12.009_bb0050","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1161\/CIRCULATIONAHA.109.927152","article-title":"Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: incidence and contributing factors (the UK CoreValve Collaborative)","volume":"123","author":"Khawaja","year":"2011","journal-title":"Circulation"},{"key":"10.1016\/j.ahj.2011.12.009_bb0055","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1093\/eurheartj\/ehq339","article-title":"Transcatheter aortic valve implantation: first results from a multi-centre real-world registry","volume":"32","author":"Zahn","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.ahj.2011.12.009_bb0060","doi-asserted-by":"crossref","first-page":"860","DOI":"10.1016\/j.ahj.2009.02.016","article-title":"Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis","volume":"157","author":"Jilaihawi","year":"2009","journal-title":"Am Heart J"},{"key":"10.1016\/j.ahj.2011.12.009_bb0065","first-page":"751","article-title":"Predictors for permanent pacing after transcatheter aortic valve implantation","volume":"76","author":"Haworth","year":"2010","journal-title":"Catheter Cardiovasc Interv"},{"key":"10.1016\/j.ahj.2011.12.009_bb0070","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1016\/j.ahj.2009.12.009","article-title":"Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesis","volume":"159","author":"Baan","year":"2010","journal-title":"Am Heart J"},{"key":"10.1016\/j.ahj.2011.12.009_bb0075","doi-asserted-by":"crossref","first-page":"1188","DOI":"10.1093\/europace\/euq094","article-title":"Electrocardiographic and further predictors for permanent pacemaker requirement after transcatheter aortic valve implantation","volume":"12","author":"Erkapic","year":"2010","journal-title":"Europace"},{"key":"10.1016\/j.ahj.2011.12.009_bb0080","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1161\/CIRCULATIONAHA.110.946533","article-title":"Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis","volume":"123","author":"Tamburino","year":"2011","journal-title":"Circulation"},{"key":"10.1016\/j.ahj.2011.12.009_bb0085","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.jacc.2007.04.047","article-title":"Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome","volume":"50","author":"Grube","year":"2007","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ahj.2011.12.009_bb0090","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1093\/eurheartj\/ehq406","article-title":"Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium","volume":"32","author":"Leon","year":"2011","journal-title":"Eur Heart J"},{"key":"10.1016\/j.ahj.2011.12.009_bb0095","doi-asserted-by":"crossref","first-page":"2256","DOI":"10.1093\/eurheartj\/ehm305","article-title":"Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in collaboration with the European Heart Rhythm Association","volume":"28","author":"Vardas","year":"2007","journal-title":"Eur Heart J"},{"key":"10.1016\/j.ahj.2011.12.009_bb0100","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/j.jcin.2007.12.009","article-title":"Atrioventricular block after transcatheter balloon expandable aortic valve implantation","volume":"1","author":"Sinhal","year":"2008","journal-title":"JACC Cardiovasc Interv"},{"key":"10.1016\/j.ahj.2011.12.009_bb0105","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/j.jacc.2009.04.032","article-title":"Results of transfemoral or transapical aortic valve implantation following a uniform assessment in high-risk patients with aortic stenosis","volume":"54","author":"Himbert","year":"2009","journal-title":"J Am Coll Cardiol"}],"container-title":["American Heart Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002870311008908?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002870311008908?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T05:46:45Z","timestamp":1757569605000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002870311008908"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,3]]},"references-count":21,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2012,3]]}},"alternative-id":["S0002870311008908"],"URL":"https:\/\/doi.org\/10.1016\/j.ahj.2011.12.009","relation":{},"ISSN":["0002-8703"],"issn-type":[{"value":"0002-8703","type":"print"}],"subject":[],"published":{"date-parts":[[2012,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Safety of a conservative strategy of permanent pacemaker implantation after transcatheter aortic CoreValve implantation","name":"articletitle","label":"Article Title"},{"value":"American Heart Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ahj.2011.12.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2012 Mosby, Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}