{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T13:46:14Z","timestamp":1780667174890,"version":"3.54.1"},"reference-count":15,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2017,8,1]],"date-time":"2017-08-01T00:00:00Z","timestamp":1501545600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,8,1]],"date-time":"2017-08-01T00:00:00Z","timestamp":1501545600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Heart Journal"],"published-print":{"date-parts":[[2017,8]]},"DOI":"10.1016\/j.ahj.2017.04.011","type":"journal-article","created":{"date-parts":[[2017,5,4]],"date-time":"2017-05-04T06:37:03Z","timestamp":1493879823000},"page":"46-53","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":18,"special_numbering":"C","title":["Retained cardiac implantable electronic device fragments are not associated with magnetic resonance imaging safety issues, morbidity, or mortality after orthotopic heart transplant"],"prefix":"10.1016","volume":"190","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6237-1403","authenticated-orcid":false,"given":"Christopher O.","family":"Austin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin","family":"Landolfo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pragnesh P.","family":"Parikh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Parag C.","family":"Patel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.L.","family":"Venkatachalam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fred M.","family":"Kusumoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"21","key":"10.1016\/j.ahj.2017.04.011_bb0005","doi-asserted-by":"crossref","first-page":"2140","DOI":"10.1056\/NEJMoa032423","article-title":"Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure","volume":"350","author":"Bristow","year":"2004","journal-title":"N Engl J Med"},{"issue":"3","key":"10.1016\/j.ahj.2017.04.011_bb0010","doi-asserted-by":"crossref","first-page":"e283","DOI":"10.1161\/CIR.0b013e318276ce9b","article-title":"2012 ACCF\/AHA\/HRS focused update incorporated into the ACCF\/AHA\/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation\/American Heart Association Task Force on Practice Guide","volume":"127","author":"Epstein","year":"2013","journal-title":"Circulation"},{"issue":"12","key":"10.1016\/j.ahj.2017.04.011_bb0015","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1056\/NEJMoa013474","article-title":"Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction","volume":"346","author":"Moss","year":"2002","journal-title":"N Engl J Med"},{"key":"10.1016\/j.ahj.2017.04.011_bb0020","first-page":"1329","article-title":"Cardiac-resynchronization therapy for the prevention of heart-failure events","volume":"361(14)","author":"Moss","year":"2009"},{"key":"10.1016\/j.ahj.2017.04.011_bb0025","first-page":"987","article-title":"Superior vena cava defibrillator coils make transvenous lead extraction more challenging and riskier","volume":"61(9)","author":"Epstein","year":"2013"},{"issue":"2","key":"10.1016\/j.ahj.2017.04.011_bb0030","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1111\/pace.12274","article-title":"Frequency and sequelae of retained implanted cardiac device material post heart transplantation","volume":"37","author":"Martin","year":"2014","journal-title":"Pacing Clin Electrophysiol"},{"issue":"2","key":"10.1016\/j.ahj.2017.04.011_bb0035","doi-asserted-by":"crossref","first-page":"159","DOI":"10.5603\/KP.2013.0009","article-title":"Post heart transplant extraction of the abandoned fragments of pacing and defibrillation leads: proposed management algorithm","volume":"71","author":"Ku\u015bmierski","year":"2013","journal-title":"Kardiol Pol"},{"issue":"7","key":"10.1016\/j.ahj.2017.04.011_bb0040","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1016\/j.hrthm.2013.03.046","article-title":"No benefit of a dual coil over a single coil ICD lead: evidence from the Sudden Cardiac Death in Heart Failure Trial","volume":"10","author":"Aoukar","year":"2013","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.ahj.2017.04.011_bb0045","first-page":"239","article-title":"Dual- versus single-coil implantable defibrillator leads: review of the literature","volume":"101(4)","author":"Neuzner","year":"2012"},{"issue":"4","key":"10.1016\/j.ahj.2017.04.011_bb0050","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1111\/j.1540-8159.2005.50024.x","article-title":"Current clinical issues for MRI scanning of pacemaker and defibrillator patients","volume":"28","author":"Kalin","year":"2005","journal-title":"Pacing Clin Electrophysiol"},{"issue":"24","key":"10.1016\/j.ahj.2017.04.011_bb0055","doi-asserted-by":"crossref","first-page":"1505","DOI":"10.1093\/eurheartj\/ehv086","article-title":"Magnetic resonance imaging safety in pacemaker and implantable cardioverter defibrillator patients: how far have we come?","volume":"36","author":"Nordbeck","year":"2015","journal-title":"Eur Heart J"},{"issue":"4","key":"10.1016\/j.ahj.2017.04.011_bb0060","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1002\/jmri.21536","article-title":"In vitro investigation of pacemaker lead heating induced by magnetic resonance imaging: role of implant geometry","volume":"28","author":"Calcagnini","year":"2008","journal-title":"J Magn Reson Imaging"},{"issue":"7","key":"10.1016\/j.ahj.2017.04.011_bb0065","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1093\/europace\/euq144","article-title":"Risks to pacemaker patients undergoing magnetic resonance imaging examinations","volume":"12","author":"Irnich","year":"2010","journal-title":"Europace"},{"issue":"2","key":"10.1016\/j.ahj.2017.04.011_bb0070","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1081\/JCMR-120019424","article-title":"Cardiac pacemakers, ICDs, and loop recorder: evaluation of translational attraction using conventional (\u201clong-bore\u201d) and \u201cshort-bore\u201d 1.5- and 3.0-tesla MR systems","volume":"5","author":"Shellock","year":"2003","journal-title":"J Cardiovasc Magn Reson"},{"issue":"6","key":"10.1016\/j.ahj.2017.04.011_bb0075","doi-asserted-by":"crossref","first-page":"1963","DOI":"10.1002\/mrm.24197","article-title":"Reducing RF-related heating of cardiac pacemaker leads in MRI: implementation and experimental verification of practical design changes","volume":"68","author":"Nordbeck","year":"2012","journal-title":"Magn Reson Med"}],"container-title":["American Heart Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002870317301370?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002870317301370?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T05:59:00Z","timestamp":1757570340000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002870317301370"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8]]},"references-count":15,"alternative-id":["S0002870317301370"],"URL":"https:\/\/doi.org\/10.1016\/j.ahj.2017.04.011","relation":{},"ISSN":["0002-8703"],"issn-type":[{"value":"0002-8703","type":"print"}],"subject":[],"published":{"date-parts":[[2017,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Retained cardiac implantable electronic device fragments are not associated with magnetic resonance imaging safety issues, morbidity, or mortality after orthotopic heart transplant","name":"articletitle","label":"Article Title"},{"value":"American Heart Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ahj.2017.04.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}