{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T02:29:00Z","timestamp":1763000940544,"version":"3.45.0"},"reference-count":53,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,1,1]],"date-time":"2021-01-01T00:00:00Z","timestamp":1609459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2020,11,16]],"date-time":"2020-11-16T00:00:00Z","timestamp":1605484800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Heart Journal Plus: Cardiology Research and Practice"],"published-print":{"date-parts":[[2021,1]]},"DOI":"10.1016\/j.ahjo.2020.100002","type":"journal-article","created":{"date-parts":[[2020,11,25]],"date-time":"2020-11-25T12:11:33Z","timestamp":1606306293000},"page":"100002","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"special_numbering":"C","title":["Mechanical circulatory support with Impella in percutaneous coronary intervention: current status"],"prefix":"10.1016","volume":"1","author":[{"given":"Baskaran","family":"Chandrasekar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ahjo.2020.100002_bb0005","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.1161\/CIRCULATIONAHA.108.814947","article-title":"Thirty year trends (1975-2005) in the magnitude, management, and hospital death rates associated with cardiogenic shock in patients with acute myocardial infarction: a population-based perspective","volume":"119","author":"Goldberg","year":"2009","journal-title":"Circulation"},{"key":"10.1016\/j.ahjo.2020.100002_bb0010","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1001\/jama.294.4.448","article-title":"Trends in management and outcomes of patients with acute myocardial infarction complicated by cardiogenic shock","volume":"294","author":"Babaev","year":"2005","journal-title":"JAMA"},{"key":"10.1016\/j.ahjo.2020.100002_bb0015","doi-asserted-by":"crossref","first-page":"790","DOI":"10.1016\/j.jcin.2013.03.020","article-title":"Enhanced mortality risk prediction with a focus on high-risk percutaneous coronary intervention (results from 1,208,137 procedures in the National Cardiovascular Data Registry)","volume":"6","author":"Brennan","year":"2013","journal-title":"JACC Cardiovasc. Interv."},{"key":"10.1016\/j.ahjo.2020.100002_bb0020","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.1056\/NEJMoa1208410","article-title":"Intraaortic balloon support for myocardial infarction with cardiogenic shock","volume":"367","author":"Thiele","year":"2012","journal-title":"N. Engl. J. Med."},{"key":"10.1016\/j.ahjo.2020.100002_bb0025","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1161\/CIRCULATIONAHA.118.038201","article-title":"Intra-aortic balloon pump in cardiogenic shock complicating acute myocardial infarction: long-term 6-year outcome of the randomized IABP-SHOCK II trial","volume":"139","author":"Thiele","year":"2019","journal-title":"Circulation"},{"key":"10.1016\/j.ahjo.2020.100002_bb0030","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1001\/jama.2010.1190","article-title":"Elective intra-aortic balloon counterpulsation during high-risk percutaneous coronary intervention: a randomized controlled trial","volume":"304","author":"Perera","year":"2010","journal-title":"JAMA"},{"key":"10.1016\/j.ahjo.2020.100002_bb0035","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1161\/CIRCULATIONAHA.112.132209","article-title":"BCIS-1 investigators. Long-term mortality data from the balloon pump-assisted coronary intervention study (BCIS-1): a randomized, clinical trial of elective balloon counterpulsation during high-risk percutaneous coronary intervention","volume":"127","author":"Perera","year":"2013","journal-title":"Circulation"},{"key":"10.1016\/j.ahjo.2020.100002_bb0040","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.jcin.2014.07.030","article-title":"Percutaneous circulatory assist devices for high-risk coronary intervention","volume":"8","author":"Myat","year":"2015","journal-title":"JACC Cardiovasc. Interv."},{"key":"10.1016\/j.ahjo.2020.100002_bb0045","first-page":"532","article-title":"Effects of left ventricular unloading by Impella recover LP2.5 on coronary hemodynamics","volume":"70","author":"Remmelink","year":"2007","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"10.1016\/j.ahjo.2020.100002_bb0050","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1111\/j.1525-1594.2007.00477.x","article-title":"Combined Impella and intra-aortic balloon pump support to improve both ventricular unloading and coronary blood flow for myocardial recovery: an experimental study","volume":"31","author":"Sauren","year":"2007","journal-title":"Artif. Organs"},{"key":"10.1016\/j.ahjo.2020.100002_bb0055","first-page":"187","article-title":"Effects of mechanical left ventricular unloading by Impella on left ventricular dynamics in high-risk and primary percutaneous coronary intervention patients","volume":"75","author":"Remmelink","year":"2010","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"10.1016\/j.ahjo.2020.100002_bb0060","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1185\/030079904125003359","article-title":"Subendocardial ischemia without coronary artery disease: is elevated left ventricular diastolic pressure the culprit?","volume":"20","author":"Elhabyan","year":"2004","journal-title":"Curr. Med. Res. Opin."},{"key":"10.1016\/j.ahjo.2020.100002_bb0065","first-page":"182","article-title":"Mechanical left ventricular unloading prior to reperfusion reduces infarct size in a canine infarction model","volume":"64","author":"Achour","year":"2005","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"10.1016\/j.ahjo.2020.100002_bb0070","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1016\/j.jchf.2015.06.010","article-title":"Mechanical pre-conditioning with acute circulatory support before reperfusion limits infarct size in acute myocardial infarction","volume":"3","author":"Kapur","year":"2015","journal-title":"JACC Heart Fail."},{"key":"10.1016\/j.ahjo.2020.100002_bb0075","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1016\/j.jacc.2018.05.034","article-title":"Left ventricular unloading before reperfusion promotes functional recovery after acute myocardial infarction","volume":"72","author":"Esposito","year":"2018","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.ahjo.2020.100002_bb0080","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1161\/CIRCULATIONAHA.112.000029","article-title":"Mechanically unloading the left ventricle before coronary reperfusion reduces left ventricular wall stress and myocardial infarct size","volume":"128","author":"Kapur","year":"2013","journal-title":"Circulation"},{"key":"10.1016\/j.ahjo.2020.100002_bb0085","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/j.pharmthera.2014.03.009","article-title":"Stromal derived factor 1\u03b1: a chemokine that delivers a two-pronged defence of the myocardium","volume":"143","author":"Bromage","year":"2014","journal-title":"Pharmacol. Ther."},{"key":"10.1016\/j.ahjo.2020.100002_bb0090","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1161\/CIRCHEARTFAILURE.110.960302","article-title":"Stromal cell-derived factor-1 retention and cardioprotection for ischemic myocardium","volume":"4","author":"Kanki","year":"2011","journal-title":"Circ. Heart Fail."},{"key":"10.1016\/j.ahjo.2020.100002_bb0095","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1016\/j.jclinepi.2009.06.005","article-title":"Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement","volume":"62","author":"Moher","year":"2009","journal-title":"J. Clin. Epidemiol."},{"key":"10.1016\/j.ahjo.2020.100002_bb0100","doi-asserted-by":"crossref","first-page":"1584","DOI":"10.1016\/j.jacc.2008.05.065","article-title":"A randomized clinical trial to evaluate the safety and efficacy of a percutaneous left ventricular assist device versus intra-aortic balloon pumping for treatment of cardiogenic shock caused by myocardial infarction","volume":"52","author":"Seyfarth","year":"2008","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.ahjo.2020.100002_bb0105","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.jacc.2016.10.022","article-title":"Percutaneous mechanical circulatory support versus intra-aortic balloon pump in cardiogenic shock after acute myocardial infarction","volume":"69","author":"Ouweneel","year":"2017","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.ahjo.2020.100002_bb0110","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.ahj.2019.04.019","article-title":"Rationale and design of DanGer shock: Danish-German cardiogenic shock trial","volume":"214","author":"Udesen","year":"2019","journal-title":"Am. Heart J."},{"key":"10.1016\/j.ahjo.2020.100002_bb0115","doi-asserted-by":"crossref","first-page":"1717","DOI":"10.1161\/CIRCULATIONAHA.112.098194","article-title":"A prospective, randomized clinical trial of hemodynamic support with Impella 2.5 versus intra-aortic balloon pump in patients undergoing high-risk percutaneous coronary intervention, the PROTECT II study","volume":"126","author":"O\u2019Neill","year":"2012","journal-title":"Circulation"},{"key":"10.1016\/j.ahjo.2020.100002_bb0120","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1056\/NEJM199908263410901","article-title":"Early revascularization in acute myocardial infarction complicated by cardiogenic shock","volume":"341","author":"Hochman","year":"1999","journal-title":"N. Engl. J. Med."},{"key":"10.1016\/j.ahjo.2020.100002_bb0125","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.ahj.2017.09.007","article-title":"The cVAD registry for percutaneous temporary hemodynamic support: a prospective registry of Impella mechanical circulatory support use in high-risk PCI, cardiogenic shock, and decompensated heart failure","volume":"199","author":"Vetrovec","year":"2018","journal-title":"Am. Heart J."},{"key":"10.1016\/j.ahjo.2020.100002_bb0130","doi-asserted-by":"crossref","DOI":"10.1155\/2019\/5243913","article-title":"Long-term outcomes of extent of revascularization in complex high risk and indicated patients undergoing Impella-protected percutaneous coronary intervention: report from the Roma-Verona registry","author":"Burzotta","year":"2019","journal-title":"J. Interv. Cardiol."},{"key":"10.1016\/j.ahjo.2020.100002_bb0135","doi-asserted-by":"crossref","first-page":"653","DOI":"10.1007\/s00392-018-1230-6","article-title":"Indication and short-term clinical outcomes of high-risk percutaneous coronary intervention with microaxial Impella pump: results from the German Impella registry","volume":"107","author":"Baumann","year":"2018","journal-title":"Clin. Res. Cardiol."},{"key":"10.1016\/j.ahjo.2020.100002_bb0140","first-page":"576","article-title":"Real-world supported unprotected left main percutaneous coronary intervention with Impella device; data from the USpella registry","volume":"90","author":"Schreiber","year":"2017","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"10.1016\/j.ahjo.2020.100002_bb0145","doi-asserted-by":"crossref","first-page":"e1343","DOI":"10.4244\/EIJ-D-19-00428","article-title":"Observational multicentre registry of patients treated with Impella mechanical circulatory support device in Italy: the IMP-IT registry","volume":"15","author":"Chieffo","year":"2020","journal-title":"Eurointervention"},{"key":"10.1016\/j.ahjo.2020.100002_bb0150","doi-asserted-by":"crossref","first-page":"1330","DOI":"10.1016\/j.amjcard.2018.07.011","article-title":"Meta-analysis and trial sequential analysis comparing percutaneous ventricular assist devices versus intra-aortic balloon pump during high-risk percutaneous coronary intervention or cardiogenic shock","volume":"122","author":"Rios","year":"2018","journal-title":"Am. J. Cardiol."},{"key":"10.1016\/j.ahjo.2020.100002_bb0155","doi-asserted-by":"crossref","first-page":"161","DOI":"10.4172\/Interventional-Cardiology.1000624","article-title":"Systematic literature review and meta-analysis of Impella devices used in cardiogenic shock and high risk percutaneous coronary interventions","volume":"11","author":"Hill","year":"2019","journal-title":"Interv. Cardiol."},{"key":"10.1016\/j.ahjo.2020.100002_bb0160","doi-asserted-by":"crossref","first-page":"1407","DOI":"10.1016\/j.jacc.2014.07.958","article-title":"National trends in the utilization of short-term mechanical circulatory support: incidence, outcomes, and cost analysis","volume":"64","author":"Stretch","year":"2014","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.ahjo.2020.100002_bb0165","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1161\/CIRCRESAHA.116.309738","article-title":"Hemodynamic support with a microaxial percutaneous left ventricular assist device (Impella) protects against acute kidney injury in patients undergoing high-risk percutaneous coronary intervention","volume":"120","author":"Flaherty","year":"2017","journal-title":"Circ. Res."},{"key":"10.1016\/j.ahjo.2020.100002_bb0170","first-page":"1111","article-title":"Impella support and acute kidney injury during high-risk percutaneous coronary intervention: the global cVAD renal protection study","volume":"95","author":"Flaherty","year":"2020","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"10.1016\/j.ahjo.2020.100002_bb0175","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1161\/CIRCULATIONAHA.119.044007","article-title":"The evolving landscape of Impella use in the United States among patients undergoing percutaneous coronary intervention with mechanical circulatory support","volume":"141","author":"Amin","year":"2020","journal-title":"Circulation"},{"key":"10.1016\/j.ahjo.2020.100002_bb0180","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1111\/joic.12080","article-title":"The current use of Impella 2.5 in acute myocardial infarction complicated by cardiogenic shock: results from the USpella registry","volume":"27","author":"O\u2019Neill","year":"2014","journal-title":"J. Interv. Cardiol."},{"key":"10.1016\/j.ahjo.2020.100002_bb0185","doi-asserted-by":"crossref","first-page":"1805","DOI":"10.1016\/j.jcin.2017.06.027","article-title":"Early initiation of Impella in acute myocardial infarction complicated by cardiogenic shock improves survival, a meta-analysis","volume":"10","author":"Flaherty","year":"2017","journal-title":"JACC Cardiovasc. Interv."},{"key":"10.1016\/j.ahjo.2020.100002_bb0190","first-page":"149","article-title":"Long-term survival after early unloading with Impella CP in acute myocardial infarction complicated by cardiogenic shock","volume":"9","author":"Loehn","year":"2020","journal-title":"Eur. Heart J. Acute Cardiovasc. Care"},{"key":"10.1016\/j.ahjo.2020.100002_bb0195","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.1161\/CIRCULATIONAHA.118.036614","article-title":"Impella support for acute myocardial infarction complicated by cardiogenic shock","volume":"139","author":"Schrage","year":"2019","journal-title":"Circulation"},{"key":"10.1016\/j.ahjo.2020.100002_bb0200","doi-asserted-by":"crossref","DOI":"10.1136\/openhrt-2019-001214","article-title":"Contemporary trends in use of mechanical circulatory support in patients with acute MI and cardiogenic shock","volume":"7","author":"Helgestad","year":"2020","journal-title":"Open Heart"},{"key":"10.1016\/j.ahjo.2020.100002_bb0205","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1001\/jama.2020.0254","article-title":"Association of use of an intravascular microaxial left ventricular assist device vs intra-aortic balloon pump with in-hospital mortality and major bleeding among patients with acute myocardial infarction complicated by cardiogenic shock","volume":"323","author":"Dhruva","year":"2020","journal-title":"JAMA"},{"key":"10.1016\/j.ahjo.2020.100002_bb0210","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1161\/CIRCULATIONAHA.118.038269","article-title":"Unloading the left ventricle before reperfusion in patients with anterior ST-segment-elevation myocardial infarction. A pilot study using the Impella CP","volume":"139","author":"Kapur","year":"2019","journal-title":"Circulation"},{"key":"10.1016\/j.ahjo.2020.100002_bb0215","first-page":"73","article-title":"Bleeding complications in patients with acute coronary syndrome undergoing early invasive management can be reduced with radial access, smaller sheath sizes, and timely sheath removal","volume":"69","author":"Cantor","year":"2007","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"10.1016\/j.ahjo.2020.100002_bb0220","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1016\/j.jcin.2020.02.042","article-title":"Frequency and impact of bleeding on outcome in patients with cardiogenic shock","volume":"13","author":"Freund","year":"2020","journal-title":"JACC Cardiovasc. Interv."},{"key":"10.1016\/j.ahjo.2020.100002_bb0225","article-title":"Outcomes of Impella-supported high-risk nonemergent percutaneous coronary intervention in a large single-center registry","author":"Azzalini","year":"2020","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"10.1016\/j.ahjo.2020.100002_bb0230","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1111\/aor.13319","article-title":"Increased plasma-free hemoglobin levels identify hemolysis in patients with cardiogenic shock and a transvalvular micro-axial flow pump","volume":"43","author":"Esposito","year":"2019","journal-title":"Artif. Organs"},{"issue":"4S","key":"10.1016\/j.ahjo.2020.100002_bb0235","doi-asserted-by":"crossref","first-page":"S407","DOI":"10.1016\/j.healun.2020.01.163","article-title":"Increased mean platelet volume is associated with decreased survival in patients supported with Impella","volume":"39","author":"Harutyunyan","year":"2020","journal-title":"J. Heart Lung Transplant."},{"key":"10.1016\/j.ahjo.2020.100002_bb0240","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0183193","article-title":"Acquired von Willebrand syndrome in cardiogenic shock patients on mechanical circulatory microaxial pump support","volume":"12","author":"Flierl","year":"2017","journal-title":"PLoS One"},{"key":"10.1016\/j.ahjo.2020.100002_bb0245","doi-asserted-by":"crossref","first-page":"381","DOI":"10.3111\/13696998.2012.762004","article-title":"The cost-effectiveness of a new percutaneous ventricular assist device for high-risk PCI patients: mid-stage evaluation from the European perspective","volume":"16","author":"Roos","year":"2013","journal-title":"J. Med. Econ."},{"key":"10.1016\/j.ahjo.2020.100002_bb0250","first-page":"88","article-title":"A value-based analysis of hemodynamic support strategies for high-risk heart failure patients undergoing a percutaneous coronary intervention","volume":"6","author":"Gregory","year":"2013","journal-title":"Am. Health Drug Benefits"},{"key":"10.1016\/j.ahjo.2020.100002_bb0255","doi-asserted-by":"crossref","first-page":"144","DOI":"10.4103\/2229-3485.184823","article-title":"Common pitfalls in statistical analysis: intention-to-treat versus per-protocol analysis","volume":"7","author":"Ranganathan","year":"2016","journal-title":"Perspect. Clin. Res."},{"key":"10.1016\/j.ahjo.2020.100002_bb0260","first-page":"148","article-title":"Clinical and economic effectiveness of percutaneous ventricular assist devices for high-risk patients undergoing percutaneous coronary intervention","volume":"27","author":"Shah","year":"2015","journal-title":"J. Invasive Cardiol."},{"key":"10.1016\/j.ahjo.2020.100002_bb0265","first-page":"1","article-title":"Percutaneous ventricular assist devices: a health technology assessment","volume":"17","author":"Health Quality Ontario","year":"2017","journal-title":"Ont. Health Technol. Assess Ser."}],"container-title":["American Heart Journal Plus: Cardiology Research and Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666602220300021?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666602220300021?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T02:25:44Z","timestamp":1763000744000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666602220300021"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1]]},"references-count":53,"alternative-id":["S2666602220300021"],"URL":"https:\/\/doi.org\/10.1016\/j.ahjo.2020.100002","relation":{},"ISSN":["2666-6022"],"issn-type":[{"type":"print","value":"2666-6022"}],"subject":[],"published":{"date-parts":[[2021,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Mechanical circulatory support with Impella in percutaneous coronary intervention: current status","name":"articletitle","label":"Article Title"},{"value":"American Heart Journal Plus: Cardiology Research and Practice","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ahjo.2020.100002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 The Author(s). Published by Elsevier Inc.","name":"copyright","label":"Copyright"}],"article-number":"100002"}}