{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T22:07:30Z","timestamp":1773353250755,"version":"3.50.1"},"reference-count":64,"publisher":"Elsevier BV","issue":"7","license":[{"start":{"date-parts":[[2016,7,1]],"date-time":"2016-07-01T00:00:00Z","timestamp":1467331200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,7,1]],"date-time":"2016-07-01T00:00:00Z","timestamp":1467331200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["The American Journal of Emergency Medicine"],"published-print":{"date-parts":[[2016,7]]},"DOI":"10.1016\/j.ajem.2016.04.033","type":"journal-article","created":{"date-parts":[[2016,5,1]],"date-time":"2016-05-01T02:08:04Z","timestamp":1462068484000},"page":"1294-1301","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":22,"title":["The emergency management of ventricular assist devices"],"prefix":"10.1016","volume":"34","author":[{"given":"Jennifer","family":"Robertson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brit","family":"Long","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alex","family":"Koyfman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"3","key":"10.1016\/j.ajem.2016.04.033_bb0005","first-page":"e28","article-title":"Heart disease and stroke statistics\u20142014 update","volume":"129","author":"Go","year":"2013","journal-title":"Circulation"},{"issue":"12","key":"10.1016\/j.ajem.2016.04.033_bb0010","doi-asserted-by":"crossref","first-page":"e305","DOI":"10.1161\/CIRCULATIONAHA.111.018226","article-title":"Ventricular assist devices: important information for patients and families","volume":"124","author":"Givertz","year":"2011","journal-title":"Circulation"},{"issue":"4","key":"10.1016\/j.ajem.2016.04.033_bb0015","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1016\/j.athoracsur.2009.12.058","article-title":"Left ventricular assist device destination therapy versus extended criteria cardiac transplant","volume":"89","author":"Daneshmand","year":"2010","journal-title":"Ann Thorac Surg"},{"issue":"6","key":"10.1016\/j.ajem.2016.04.033_bb0020","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/j.cardfail.2012.03.003","article-title":"Persistent anemia after implantation of the total artificial heart","volume":"18","author":"Mankad","year":"2012","journal-title":"J Card Fail"},{"key":"10.1016\/j.ajem.2016.04.033_bb0025","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1111\/j.1755-5922.2009.00081.x","article-title":"Ventricular assist device therapy","volume":"27","author":"Sayer","year":"2009","journal-title":"Cardiovasc Ther"},{"issue":"5","key":"10.1016\/j.ajem.2016.04.033_bb0030","doi-asserted-by":"crossref","first-page":"1746","DOI":"10.1016\/j.athoracsur.2012.02.026","article-title":"Implantable continuous-flow right ventricular assist device: lessons learned in the development of a Cleveland Clinic device","volume":"93","author":"Fukamachi","year":"2012","journal-title":"Ann Thorac Surg"},{"issue":"6","key":"10.1016\/j.ajem.2016.04.033_bb0035","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1016\/j.healun.2014.04.010","article-title":"Sixth INTERMACS annual report: a 10,000-patient database","volume":"33","author":"Kirklin","year":"2014","journal-title":"J Heart Lung Transplant"},{"issue":"4","key":"10.1016\/j.ajem.2016.04.033_bb0040","doi-asserted-by":"crossref","first-page":"971","DOI":"10.1016\/j.jtcvs.2008.09.021","article-title":"Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist device","volume":"137","author":"Fitzpatrick","year":"2009","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"45","key":"10.1016\/j.ajem.2016.04.033_bb0045","doi-asserted-by":"crossref","first-page":"S142","DOI":"10.1016\/j.annemergmed.2012.06.436","article-title":"Characteristics and frequency of emergency department visits of patients with continuous flow left ventricular assist devices","volume":"60","author":"Devine","year":"2012","journal-title":"Ann Emerg Med"},{"issue":"2","key":"10.1016\/j.ajem.2016.04.033_bb0050","doi-asserted-by":"crossref","first-page":"115","DOI":"10.14503\/THIJ-14-4143","article-title":"State of the art mechanical circulatory support","volume":"41","author":"Mallidi","year":"2014","journal-title":"Tex Heart Inst J"},{"issue":"18","key":"10.1016\/j.ajem.2016.04.033_bb0055","doi-asserted-by":"crossref","first-page":"1647","DOI":"10.1016\/j.jacc.2009.06.035","article-title":"Ventricular assist devices: the challenges of outpatient management","volume":"54","author":"Wilson","year":"2009","journal-title":"J Am Coll Cardiol"},{"issue":"3","key":"10.1016\/j.ajem.2016.04.033_bb0060","article-title":"Management of continuous flow left ventricular assist device patients in the cardiac catheterization laboratory","volume":"22","author":"Kapur","year":"2014","journal-title":"Cath Lab Digest"},{"issue":"4","key":"10.1016\/j.ajem.2016.04.033_bb0070","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/j.healun.2011.01.717","article-title":"Working formulation for the standardization of definitions of infections in patients using ventricular assist devices","volume":"30","author":"Hannan","year":"2011","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.ajem.2016.04.033_bb0075","article-title":"Current status of mechanical circulatory support: a systematic review","author":"Spiopoulos","year":"2012","journal-title":"Cardiol Res Pract"},{"issue":"4","key":"10.1016\/j.ajem.2016.04.033_bb0080","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1016\/j.emc.2014.07.009","article-title":"Mechanical circulatory support","volume":"32","author":"Greenwood","year":"2014","journal-title":"Emerg Med Clin North Am"},{"issue":"4","key":"10.1016\/j.ajem.2016.04.033_bb0085","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1016\/j.ccl.2012.07.003","article-title":"Management of implantable assisted circulation devices: emergency issues","volume":"30","author":"Klein","year":"2012","journal-title":"Cardiol Clin"},{"issue":"1","key":"10.1016\/j.ajem.2016.04.033_bb0090","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1213\/ane.0b013e318187b8fc","article-title":"Left ventricular assist device outflow cannula obstruction by the rare environmental fungus Myceliophthora thermophila","volume":"108","author":"Weitzel","year":"2009","journal-title":"Anesth Analg"},{"key":"10.1016\/j.ajem.2016.04.033_bb0095","first-page":"141","article-title":"Acquired von Willebrand syndrome in patients with a centrifugal or axial continuous flow left ventricular assist device","volume":"2","author":"Meyer","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ajem.2016.04.033_bb0100","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1016\/j.athoracsur.2010.04.099","article-title":"Acquired von Willebrand syndrome in continuous-flow ventricular assist device recipients","volume":"90","author":"Crow","year":"2010","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.ajem.2016.04.033_bb0105","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1161\/CIRCHEARTFAILURE.111.962613","article-title":"Mechanisms of bleeding and approach to patients with axial-flow left ventricular assist devices","volume":"4","author":"Suarez","year":"2011","journal-title":"Circ Heart Fail"},{"key":"10.1016\/j.ajem.2016.04.033_bb0110","doi-asserted-by":"crossref","first-page":"3038","DOI":"10.1161\/CIRCULATIONAHA.111.040246","article-title":"Bleeding and thrombosis in patients with continuous-flow ventricular assist devices","volume":"125","author":"Eckman","year":"2012","journal-title":"Circulation"},{"key":"10.1016\/j.ajem.2016.04.033_bb0115","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.jacc.2009.03.055","article-title":"Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device","volume":"54","author":"Pagani","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ajem.2016.04.033_bb0120","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1016\/j.ejcts.2007.12.047","article-title":"Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand diseases","volume":"33","author":"Geisen","year":"2008","journal-title":"Eur J Cardiothorac Surg"},{"issue":"4","key":"10.1016\/j.ajem.2016.04.033_bb0125","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1016\/j.healun.2010.01.011","article-title":"Clinical management of continuous flow left ventricular assist devices in advanced heart failure","volume":"29","author":"Slaughter","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.ajem.2016.04.033_bb0130","doi-asserted-by":"crossref","DOI":"10.4061\/2011\/187434","article-title":"Focused review on transthoracic echocardiographic assessment of patients with continuous axial left ventricular assist devices","author":"Topilsky","year":"2011","journal-title":"Cardiol Res Pract"},{"issue":"2","key":"10.1016\/j.ajem.2016.04.033_bb0135","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.healun.2012.09.013","article-title":"The 2013 International Society for Heart and Lung Transplantation guidelines for mechanical circulatory support: executive summary","volume":"32","author":"Feldman","year":"2013","journal-title":"J Heart Lung Transplant"},{"issue":"10","key":"10.1016\/j.ajem.2016.04.033_bb0140","doi-asserted-by":"crossref","first-page":"1161","DOI":"10.1161\/CIRCULATIONAHA.113.002836","article-title":"Assessment and management of heart failure after left ventricular assist device implantation","volume":"129","author":"Burke","year":"2014","journal-title":"Circulation"},{"issue":"1","key":"10.1016\/j.ajem.2016.04.033_bb0145","first-page":"S52","article-title":"Right heart failure post left ventricular assist device implantation","volume":"6","author":"Argiriou","year":"2014","journal-title":"J Thorac Dis"},{"issue":"1","key":"10.1016\/j.ajem.2016.04.033_bb0150","doi-asserted-by":"crossref","first-page":"69","DOI":"10.4037\/NCI.0b013e318240aaa9","article-title":"Ventricular assist devices: what intensive care unit nurses need to know about postoperative management","volume":"23","author":"O'Shea","year":"2012","journal-title":"AACN Adv Crit Care"},{"issue":"3","key":"10.1016\/j.ajem.2016.04.033_bb0155","doi-asserted-by":"crossref","first-page":"E47","DOI":"10.1111\/j.1525-1594.2010.01168.x","article-title":"Response of rotary blood pumps to changes in preload and afterload at a fixed speed are unphysiological when compared with the natural heart","volume":"35","author":"Salamonsen","year":"2011","journal-title":"Artif Organs"},{"key":"10.1016\/j.ajem.2016.04.033_bb0160","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/j.healun.2013.05.002","article-title":"Algorithm for the diagnosis and management of suspected pump thrombus","volume":"32","author":"Goldstein","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.ajem.2016.04.033_bb0165","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.healun.2013.10.005","article-title":"Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: a multifactorial phenomenon","volume":"33","author":"Uriel","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.ajem.2016.04.033_bb0170","doi-asserted-by":"crossref","first-page":"1262","DOI":"10.1016\/j.athoracsur.2012.08.031","article-title":"Device exchange after primary left ventricular assist device implantation: indications and outcomes","volume":"95","author":"Stulak","year":"2013","journal-title":"Ann Thorac Surg"},{"issue":"5","key":"10.1016\/j.ajem.2016.04.033_bb0175","first-page":"490","article-title":"Evaluation and treatment of pump thrombosis and hemolysis","volume":"3","author":"Tchantchaleishvili","year":"2014","journal-title":"Ann Cardiothorac Surg"},{"issue":"1","key":"10.1016\/j.ajem.2016.04.033_bb0180","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.healun.2009.06.023","article-title":"Noninvasive assessment of left ventricular assist devices with cardiovascular computed tomography and impact on management","volume":"29","author":"Raman","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.ajem.2016.04.033_bb0185","doi-asserted-by":"crossref","first-page":"e27","DOI":"10.1161\/CIRCHEARTFAILURE.111.966119","article-title":"Utilization of cardiac computed tomography angiography for the diagnosis of left ventricular assist device thrombosis","volume":"5","author":"Mishkin","year":"2012","journal-title":"Circ Heart Fail"},{"issue":"4","key":"10.1016\/j.ajem.2016.04.033_bb0190","doi-asserted-by":"crossref","first-page":"S186","DOI":"10.1016\/j.healun.2013.01.451","article-title":"Management and outcomes of ventricular assist device patients with suspected pump thrombosis","volume":"32","author":"Lenneman","year":"2013","journal-title":"J Heart Lung Transplant"},{"issue":"1","key":"10.1016\/j.ajem.2016.04.033_bb0195","doi-asserted-by":"crossref","first-page":"192","DOI":"10.4103\/0971-9784.173047","article-title":"Rodriguez-Blanco. Intravenous thrombolytic therapy for patients with ventricular assist device thrombosis: an attempt to avoid reoperation","volume":"19","author":"Webber","year":"2016","journal-title":"Ann Card Anaesth"},{"key":"10.1016\/j.ajem.2016.04.033_bb0200","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1136\/hrt.2007.130740","article-title":"Left ventricular assist devices","volume":"96","author":"Birks","year":"2010","journal-title":"Heart"},{"key":"10.1016\/j.ajem.2016.04.033_bb0205","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1161\/CIRCHEARTFAILURE.114.001891","article-title":"Left ventricular assist device outflow cannula obstruction treated with percutaneous endovascular stenting","volume":"8","author":"Abraham","year":"2015","journal-title":"Circ Heart Fail"},{"issue":"1","key":"10.1016\/j.ajem.2016.04.033_bb0210","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1016\/j.athoracsur.2011.12.024","article-title":"Successful treatment of early thrombosis of HeartWare left ventricular device with intraventricular thrombolytics","volume":"94","author":"Kamouh","year":"2012","journal-title":"Ann Thorac Surg"},{"issue":"20","key":"10.1016\/j.ajem.2016.04.033_bb0215","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1056\/NEJMoa012175","article-title":"Long term use of a left ventricular assist device for end stage heart failure","volume":"345","author":"Rose","year":"2001","journal-title":"N Engl J Med"},{"issue":"5","key":"10.1016\/j.ajem.2016.04.033_bb0220","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1016\/j.jemermed.2014.07.028","article-title":"Emergent reconnection of a transected left ventricular assist device driveline","volume":"47","author":"Cubillo","year":"2014","journal-title":"J Emerg Med"},{"key":"10.1016\/j.ajem.2016.04.033_bb0225","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1111\/j.1540-8167.2010.01911.x","article-title":"Ventricular tachycardia in the era of ventricular assist devices","volume":"22","author":"Cesario","year":"2011","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"9","key":"10.1016\/j.ajem.2016.04.033_bb0230","doi-asserted-by":"crossref","first-page":"1428","DOI":"10.1016\/j.jacc.2005.01.035","article-title":"Effects of left ventricular assist device therapy on ventricular arrhythmias","volume":"45","author":"Ziv","year":"2005","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.ajem.2016.04.033_bb0235","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1161\/CIRCEP.113.000113","article-title":"Ventricular arrhythmias after left ventricular assist device","volume":"6","author":"Nakahara","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"9","key":"10.1016\/j.ajem.2016.04.033_bb0240","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1056\/NEJMoa067758","article-title":"Use of a continuous flow device in patients awaiting heart transplantation","volume":"357","author":"Miller","year":"2007","journal-title":"N Engl J Med"},{"key":"10.1016\/j.ajem.2016.04.033_bb0245","doi-asserted-by":"crossref","first-page":"1241","DOI":"10.1161\/hc3601.095718","article-title":"Electrophysiological alterations after mechanical circulatory support in patients with advanced cardiac failure","volume":"104","author":"Harding","year":"2001","journal-title":"Circulation"},{"key":"10.1016\/j.ajem.2016.04.033_bb0250","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.annemergmed.2010.05.023","article-title":"Asymptomatic sustained ventricular fibrillation in a patient with left ventricular assist device","volume":"57","author":"Busch","year":"2011","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.ajem.2016.04.033_bb0255","first-page":"33","article-title":"Ventricular assist device support for management of sustained ventricular arrhythmias","volume":"29","author":"Fasseas","year":"2001","journal-title":"Tex Heart Inst J"},{"key":"10.1016\/j.ajem.2016.04.033_bb0260","doi-asserted-by":"crossref","first-page":"533","DOI":"10.3109\/10903127.2011.598616","article-title":"Sustained ventricular fibrillation in an alert patient: preserved hemodynamics with a left ventricular assist device","volume":"15","author":"Patel","year":"2011","journal-title":"Prehosp Emerg Care"},{"issue":"7","key":"10.1016\/j.ajem.2016.04.033_bb0265","doi-asserted-by":"crossref","first-page":"1688","DOI":"10.1016\/0735-1097(94)90175-9","article-title":"Malignant ventricular arrhythmias are well tolerated in patients receiving long-term left ventricular assist devices","volume":"24","author":"Oz","year":"1994","journal-title":"J Am Coll Cardiol"},{"issue":"8","key":"10.1016\/j.ajem.2016.04.033_bb0270","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1016\/j.healun.2007.05.011","article-title":"Suction events during left ventricular support and ventricular arrhythmias","volume":"26","author":"Vollkron","year":"2007","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.ajem.2016.04.033_bb0275","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1016\/j.resuscitation.2014.01.003","article-title":"Chest compressions may be safe in arresting patients with left ventricular assist devices (LVADS)","volume":"85","author":"Shinar","year":"2014","journal-title":"Resuscitation"},{"issue":"10","key":"10.1016\/j.ajem.2016.04.033_bb0280","doi-asserted-by":"crossref","first-page":"1438","DOI":"10.1093\/cid\/cit536","article-title":"Clinical manifestations and management of left ventricular assist device-associated infections","volume":"57","author":"Nienaber","year":"2013","journal-title":"Clin Infect Dis"},{"key":"10.1016\/j.ajem.2016.04.033_bb0285","doi-asserted-by":"crossref","first-page":"1151","DOI":"10.1016\/j.healun.2012.05.004","article-title":"Continuous-flow devices and percutaneous site infections: clinical outcomes","volume":"31","author":"Goldstein","year":"2012","journal-title":"J Heart Lung Transplant"},{"issue":"6","key":"10.1016\/j.ajem.2016.04.033_bb0290","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1161\/CIRCULATIONAHA.112.128132","article-title":"A prospective, multicenter study of ventricular assist device infections","volume":"127","author":"Gordon","year":"2013","journal-title":"Circulation"},{"issue":"5","key":"10.1016\/j.ajem.2016.04.033_bb0295","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1586\/erd.11.36","article-title":"Left ventricular assist device-related infections: past, present and future","volume":"8","author":"Maniar","year":"2011","journal-title":"Expert Rev Med Devices"},{"issue":"2","key":"10.1016\/j.ajem.2016.04.033_bb0300","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1586\/eri.12.163","article-title":"Current concepts in the diagnosis and management of left ventricular assist device infections","volume":"11","author":"Nienaber","year":"2013","journal-title":"Expert Rev Anti Infect Ther"},{"key":"10.1016\/j.ajem.2016.04.033_bb0305","doi-asserted-by":"crossref","first-page":"750","DOI":"10.3390\/healthcare3030750","article-title":"The importance of the management of infectious complications for patients with left ventricular assist device","volume":"3","author":"Hieda","year":"2015","journal-title":"Healthcare"},{"key":"10.1016\/j.ajem.2016.04.033_bb0310","doi-asserted-by":"crossref","first-page":"1270","DOI":"10.1016\/j.athoracsur.2010.04.093","article-title":"Infectious complications in patients with left ventricular assist device: etiology and outcomes in the continuous-flow era","volume":"90","author":"Topkara","year":"2010","journal-title":"Ann Thorac Surg"},{"key":"10.1016\/j.ajem.2016.04.033_bb0315","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.healun.2010.08.003","article-title":"Infectious complications after pulsatile-flow and continuous-flow left ventricular assist device implantation","volume":"30","author":"Schaffer","year":"2011","journal-title":"J Heart Lung Transplant"},{"issue":"1","key":"10.1016\/j.ajem.2016.04.033_bb0320","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.healun.2009.10.009","article-title":"Second intermacs annual report: more than 1000 primary LVAD implants","volume":"29","author":"Kirklin","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"10.1016\/j.ajem.2016.04.033_bb0325","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.jtcvs.2008.07.032","article-title":"Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices","volume":"137","author":"Crow","year":"2009","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["The American Journal of Emergency Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0735675716300572?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0735675716300572?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T15:30:34Z","timestamp":1760023834000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0735675716300572"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7]]},"references-count":64,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2016,7]]}},"alternative-id":["S0735675716300572"],"URL":"https:\/\/doi.org\/10.1016\/j.ajem.2016.04.033","relation":{},"ISSN":["0735-6757"],"issn-type":[{"value":"0735-6757","type":"print"}],"subject":[],"published":{"date-parts":[[2016,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The emergency management of ventricular assist devices","name":"articletitle","label":"Article Title"},{"value":"The American Journal of Emergency Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ajem.2016.04.033","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}