{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T16:31:44Z","timestamp":1786984304497,"version":"build-2736575974"},"reference-count":61,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2019,3,1]],"date-time":"2019-03-01T00:00:00Z","timestamp":1551398400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,3,1]],"date-time":"2019-03-01T00:00:00Z","timestamp":1551398400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2018,9,13]],"date-time":"2018-09-13T00:00:00Z","timestamp":1536796800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"name":"central sterilization service department and hospital personnel of the Centre Hospitalier de l'Universit\u00e9 Laval"},{"name":"Hotel-Dieu de Qu\u00e9bec hospital in Quebec City, Canada"}],"content-domain":{"domain":["ajicjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Journal of Infection Control"],"published-print":{"date-parts":[[2019,3]]},"DOI":"10.1016\/j.ajic.2018.09.009","type":"journal-article","created":{"date-parts":[[2018,11,13]],"date-time":"2018-11-13T01:19:02Z","timestamp":1542071942000},"page":"243-250","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":20,"title":["Elevating the standard of endoscope processing: Terminal sterilization of duodenoscopes using a hydrogen peroxide\u2013ozone sterilizer"],"prefix":"10.1016","volume":"47","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0540-1885","authenticated-orcid":false,"given":"Vanessa","family":"Molloy-Simard","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Luc","family":"Lemyre","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karine","family":"Martel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bradley J.","family":"Catalone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ajic.2018.09.009_bib0002","doi-asserted-by":"crossref","first-page":"E259","DOI":"10.1055\/s-0034-1392099","article-title":"Infectious diseases linked to cross-contamination of flexible endoscopes","volume":"3","author":"Kenters","year":"2015","journal-title":"Endosc Int Open"},{"issue":"5","key":"10.1016\/j.ajic.2018.09.009_bib0003","doi-asserted-by":"crossref","first-page":"361","DOI":"10.5946\/ce.2015.48.5.361","article-title":"Current issues in duodenoscope-associated infections: now is the time to take action","volume":"48","author":"Ha","year":"2015","journal-title":"Clin Endosc"},{"key":"10.1016\/j.ajic.2018.09.009_bib0004","doi-asserted-by":"crossref","first-page":"h997","DOI":"10.1136\/bmj.h997","article-title":"Meticulous\u201d cleaning of duodenoscopes may not eliminate infection risk, US watchdog warns","volume":"350","author":"McCarthy","year":"2015","journal-title":"BMJ"},{"key":"10.1016\/j.ajic.2018.09.009_bib0005","author":"Murray"},{"key":"10.1016\/j.ajic.2018.09.009_bib0006","doi-asserted-by":"crossref","first-page":"3118","DOI":"10.1128\/JCM.01394-15","article-title":"Superbugs on duodenoscopes: the challenge of cleaning and disinfection of reusable devices","volume":"53","author":"Humphries","year":"2015","journal-title":"J Clin Microbiol"},{"key":"10.1016\/j.ajic.2018.09.009_bib0007","first-page":"1051","article-title":"New Delhi Metallo-\u03b2-Lactamase\u2013producing Escherichia coli associated with endoscopic retrograde cholangiopancreatography \u2014 Illinois, 2013","volume":"62","year":"2014","journal-title":"MMWR Morb Mortal Wkly Rep"},{"key":"10.1016\/j.ajic.2018.09.009_bib0008","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1055\/s-0033-1359234","article-title":"Residual bioburden in reprocessed side-view endoscopes used for endoscopic retrograde cholangiopancreatography (ERCP)","volume":"1","author":"Ubhayawardana","year":"2013","journal-title":"Endosc Int Open"},{"key":"10.1016\/j.ajic.2018.09.009_bib0009","doi-asserted-by":"crossref","first-page":"1188","DOI":"10.1016\/j.ajic.2013.04.022","article-title":"Reported gastrointestinal endoscope reprocessing lapses: the tip of the iceberg","volume":"41","author":"Dirlam Langlay","year":"2013","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2018.09.009_bib0010","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1007\/s11894-016-0528-7","article-title":"Current practice of duodenoscope reprocessing","volume":"18","author":"Kim","year":"2016","journal-title":"Curr Gastroenterol Rep"},{"key":"10.1016\/j.ajic.2018.09.009_bib0011","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1007\/s11938-016-0088-9","article-title":"Duodenoscope-associated bacterial infections: a review and update","volume":"14","author":"Higa","year":"2016","journal-title":"Curr Treat Options Gastroenterol"},{"key":"10.1016\/j.ajic.2018.09.009_bib0012","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1186\/s13756-015-0049-4","article-title":"An outbreak of carbapenem-resistant OXA-48-producing Klebsiella pneumonia associated to duodenoscopy","volume":"4","author":"Kola","year":"2015","journal-title":"Antimicrob Resist Infect Control"},{"key":"10.1016\/j.ajic.2018.09.009_bib0013","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/j.gie.2015.04.036","article-title":"A quarantine process for the resolution of duodenoscope-associated transmission of multidrug-resistant Escherichia coli","volume":"82","author":"Ross","year":"2015","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.ajic.2018.09.009_bib0014","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1093\/cid\/ciy084","article-title":"Regional spread of an outbreak of carbapenem-resistant enterobacteriaceae (CRE) through an ego network of healthcare facilities","volume":"67","author":"Ray","year":"2018","journal-title":"Clin Infect Dis Off Publ Infect Dis Soc Am"},{"key":"10.1016\/j.ajic.2018.09.009_bib0015","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1055\/s-0034-1391886","article-title":"Withdrawal of a novel-design duodenoscope ends outbreak of a VIM-2-producing Pseudomonas aeruginosa","volume":"47","author":"Verfaillie","year":"2015","journal-title":"Endoscopy"},{"key":"10.1016\/j.ajic.2018.09.009_bib0016","doi-asserted-by":"crossref","first-page":"457","DOI":"10.4253\/wjge.v6.i10.457","article-title":"Risk of transmission of carbapenem-resistant Enterobacteriaceae and related \u201csuperbugs\u201d during gastrointestinal endoscopy","volume":"6","author":"Muscarella","year":"2014","journal-title":"World J Gastrointest Endosc"},{"key":"10.1016\/j.ajic.2018.09.009_bib0017","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1017\/ice.2015.66","article-title":"Endoscopic retrograde cholangiopancreatography-associated AmpC Escherichia coli outbreak","volume":"36","author":"Wendorf","year":"2015","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2018.09.009_bib0018","doi-asserted-by":"crossref","first-page":"1447","DOI":"10.1001\/jama.2014.12720","article-title":"New Delhi metallo-\u03b2-lactamase-producing carbapenem-resistant Escherichia coli associated with exposure to duodenoscopes","volume":"312","author":"Epstein","year":"2014","journal-title":"JAMA"},{"key":"10.1016\/j.ajic.2018.09.009_bib0019","doi-asserted-by":"crossref","first-page":"1159","DOI":"10.1093\/cid\/cix527","article-title":"Duodenoscope-related outbreak of a carbapenem-resistant Klebsiella pneumoniae identified using advanced molecular diagnostics","volume":"65","author":"Humphries","year":"2017","journal-title":"Clin Infect Dis Off Publ Infect Dis Soc Am"},{"key":"10.1016\/j.ajic.2018.09.009_bib0020","first-page":"11","article-title":"Control of a multi-hospital outbreak of KPC-producing Klebsiella pneumoniae type 2 in France, September to October 2009","volume":"15","author":"Carbonne","year":"2010","journal-title":"Euro Surveill Bull Eur Sur Mal Transm Eur Commun Dis Bull"},{"key":"10.1016\/j.ajic.2018.09.009_bib0023","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1017\/ice.2015.256","article-title":"Adequacy of duodenoscope reprocessing methods as reported by infectious disease physicians","volume":"37","author":"Beekmann","year":"2016","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2018.09.009_bib0024","article-title":"Supplemental measures to enhance duodenoscope reprocessing: FDA safety communication","year":"2015","journal-title":"FDA;"},{"key":"10.1016\/j.ajic.2018.09.009_bib0025","first-page":"56","article-title":"Microbiological Surveillance of Flexible Endoscopes","volume":"6","author":"Catalone","year":"2006","journal-title":"Manag Infect Control"},{"issue":"2","key":"10.1016\/j.ajic.2018.09.009_bib0026","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1128\/JCM.02754-15","article-title":"Comparison of two culture methods for use in assessing microbial contamination of duodenoscopes","volume":"54","author":"Gazdik","year":"2016","journal-title":"J Clin Microbiol"},{"issue":"Suppl 5","key":"10.1016\/j.ajic.2018.09.009_bib0027","doi-asserted-by":"crossref","first-page":"e47","DOI":"10.1016\/j.ajic.2015.10.037","article-title":"Outbreaks of carbapenem-resistant Enterobacteriaceae infections associated with duodenoscopes: What can we do to prevent infections?","volume":"44","author":"Rutala","year":"2016","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2018.09.009_bib0028","doi-asserted-by":"crossref","first-page":"1666","DOI":"10.1038\/ajg.2015.358","article-title":"Cost utility of competing strategies to prevent endoscopic transmission of carbapenem-resistant Enterobacteriaceae","volume":"110","author":"Almario","year":"2015","journal-title":"Am J Gastroenterol"},{"key":"10.1016\/j.ajic.2018.09.009_bib0029","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1016\/j.ajic.2017.12.007","article-title":"A systematic review of adenosine triphosphate as a surrogate for bacterial contamination of duodenoscopes used for endoscopic retrograde cholangiopancreatography","volume":"46","author":"Olafsdottir","year":"2018","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2018.09.009_bib0030","first-page":"588","article-title":"A double-reprocessing high-level disinfection protocol does not eliminate positive cultures from the elevators of duodenoscopes","volume":"50","author":"Rex","year":"2017","journal-title":"Endoscopy"},{"key":"10.1016\/j.ajic.2018.09.009_bib0031","doi-asserted-by":"crossref","first-page":"1018","DOI":"10.1053\/j.gastro.2017.06.052","article-title":"randomized comparison of 3 high-level disinfection and sterilization procedures for duodenoscopes","volume":"153","author":"Snyder","year":"2017","journal-title":"Gastroenterology"},{"key":"10.1016\/j.ajic.2018.09.009_bib0032","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1016\/j.gie.2018.02.016","article-title":"A randomized trial of single versus double high-level disinfection of duodenoscopes and linear echoendoscopes using standard automated reprocessing","volume":"88","author":"Bartles","year":"2018","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.ajic.2018.09.009_bib0033","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1055\/s-0029-1215086","article-title":"Is bacteriologic surveillance in endoscope reprocessing stringent enough?","volume":"41","author":"Kovaleva","year":"2009","journal-title":"Endoscopy"},{"key":"10.1016\/j.ajic.2018.09.009_bib0034","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1016\/j.gie.2016.08.043","article-title":"Echoing concerns related to endoscope reprocessing","volume":"85","author":"Visrodia","year":"2017","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.ajic.2018.09.009_bib0035","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/j.gie.2016.01.055","article-title":"Impact of ethylene oxide gas sterilization of duodenoscopes after a carbapenem-resistant Enterobacteriaceae outbreak","volume":"84","author":"Naryzhny","year":"2016","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.ajic.2018.09.009_bib0036","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1016\/j.gie.2015.07.004","article-title":"Duodenoscope reprocessing: risk and options coming into view","volume":"82","author":"Petersen","year":"2015","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.ajic.2018.09.009_bib0037","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1016\/j.gie.2016.10.002","article-title":"Multisociety guideline on reprocessing flexible GI endoscopes: 2016 update","volume":"85","author":"Petersen","year":"2017","journal-title":"Gastrointest Endosc."},{"key":"10.1016\/j.ajic.2018.09.009_bib0038","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1016\/j.idc.2016.04.002","article-title":"Disinfection and sterilization in health care facilities","volume":"30","author":"Rutala","year":"2016","journal-title":"Infect Dis Clin North Am"},{"key":"10.1016\/j.ajic.2018.09.009_bib0039","first-page":"10","article-title":"Citing infection danger, experts call for endoscope sterilization","volume":"52","year":"2017","journal-title":"AAMINews"},{"key":"10.1016\/j.ajic.2018.09.009_bib0040","first-page":"12","article-title":"Infection prevention imperatives for 2018","volume":"22","author":"Pyrek","year":"2018","journal-title":"Infection Control Today"},{"key":"10.1016\/j.ajic.2018.09.009_bib0041","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1016\/j.ajic.2016.01.008","article-title":"Effectiveness of the SYSTEM 1E liquid chemical sterilant processing system for reprocessing duodenoscopes","volume":"44","author":"McDonnell","year":"2016","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2018.09.009_bib0042","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/j.jhin.2011.05.002","article-title":"Disinfection: is it time to reconsider Spaulding?","volume":"78","author":"McDonnell","year":"2011","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.ajic.2018.09.009_bib0043","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1053\/j.gastro.2016.05.040","article-title":"Infection using ERCP endoscopes","volume":"151","author":"Petersen","year":"2016","journal-title":"Gastroenterology"},{"key":"10.1016\/j.ajic.2018.09.009_bib0044","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1086\/647252","article-title":"Comparison of ion plasma, vaporized hydrogen peroxide, and 100% ethylene oxide sterilizers to the 12\/88 ethylene oxide gas sterilizer","volume":"17","author":"Alfa","year":"1996","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2018.09.009_bib0045","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1016\/S0196-6553(98)70018-5","article-title":"Comparison of liquid chemical sterilization with peracetic acid and ethylene oxide sterilization for long narrow lumens","volume":"26","author":"Alfa","year":"1998","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2018.09.009_bib0046","doi-asserted-by":"crossref","first-page":"1405","DOI":"10.1001\/jama.2014.12559","article-title":"Gastrointestinal endoscopes: a need to shift from disinfection to sterilization?","volume":"312","author":"Rutala","year":"2014","journal-title":"JAMA"},{"key":"10.1016\/j.ajic.2018.09.009_bib0047","unstructured":"ANSI\/ AAMI Association for the Advancement of Medical Instrumentation. ANSI\/AAMI ST41:2008 Ethylene oxide sterilization in health care facilities: Safety and effectiveness Single user. 2008."},{"key":"10.1016\/j.ajic.2018.09.009_bib0048","unstructured":"Cision. TSO3 Duodenoscope sterilization technology to be featured at the 18th world federation for hospital. [cited 2018 Feb 13]. Available from: https:\/\/www.newswire.ca\/news-releases\/tso3-duodenoscope-sterilization-technology-to-be-featured-at-the-18th-world-federation-for-hospital-sterilisation-sciences-wfhss-congress-in-bonn-germany-649292513.html"},{"key":"10.1016\/j.ajic.2018.09.009_bib0049","unstructured":"Jun 14 OTM|, Insights 2018 | Industry, News, Notes | 0. Health system improves patient care with expanded use of sterilization technology OR today. [cited 2018 Sep 4]. Available from: http:\/\/ortoday.com\/health-system-improves-patient-care-with-expanded-use-of-sterilization-technology\/"},{"key":"10.1016\/j.ajic.2018.09.009_bib0050","first-page":"169","article-title":"The first dual-sterilant low-temperature sterilization system","volume":"31","author":"Dufresne","year":"2016","journal-title":"Can J Infect Control"},{"key":"10.1016\/j.ajic.2018.09.009_bib0051","unstructured":"Letter from Olympus | Olympus America | Medical. [cited 2018 Feb 13]. Available from: http:\/\/medical.olympusamerica.com\/letter-from-olympus"},{"key":"10.1016\/j.ajic.2018.09.009_bib0052","unstructured":"FDA. Class 2 device recall EVIS EXERA II duodenovideoscope OLYMPUS TJF TypeQ180V FDA#Z-2807-2015. [cited 2018 Feb 13]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfres\/res.cfm?id=135241"},{"key":"10.1016\/j.ajic.2018.09.009_bib0053","unstructured":"FDA. Class 2 device recall Evis Exera II Duodenovideoscope Olympus TJFQ180V FDA#Z0757-2016. [cited 2018 Aug 6]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfRes\/res.cfm?ID=142937"},{"key":"10.1016\/j.ajic.2018.09.009_bib0054","unstructured":"ANSI\/AAMI\/ISO. ANSI\/AAMI\/ISO 14937:2009 Sterilization of health care products \u2014 General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices. Association for the Advancement of Medical Instrumentation 2009:39."},{"key":"10.1016\/j.ajic.2018.09.009_bib0055","first-page":"154","article-title":"ANSI\/AAMI ST58:2013 Chemical sterilization and high-level disinfection in health care facilities","year":"2013","journal-title":"Association for the Advancement of Medical Instrumentation"},{"key":"10.1016\/j.ajic.2018.09.009_bib0056","first-page":"165","article-title":"A new method to sterilize multichannel flexible colonoscopes","volume":"32","author":"Dufresne","year":"2017","journal-title":"Can J Infect Control"},{"key":"10.1016\/j.ajic.2018.09.009_bib0057","unstructured":"FDA I control devices branch. Guidance on Premarket Notification [510(k)] Submissions for - Sterilizers Intended for Use in Health Care Facilities [Internet]. 1993 [cited 2018 May 1]. Available from: https:\/\/www.fda.gov\/downloads\/medicaldevices\/deviceregulationandguidance\/guidancedocuments\/ucm081341.pdf"},{"key":"10.1016\/j.ajic.2018.09.009_bib0058","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1016\/j.gie.2016.06.041","article-title":"Evaluation of current cleaning and disinfection procedures of GI endoscopes","volume":"84","author":"Saliou","year":"2016","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.ajic.2018.09.009_bib0059","first-page":"48","article-title":"ANSI\/AAMI\/ISO 11737-1 Sterilization of heath case products-microbiological methods-part 1: determination of a population of microorganisms on products","year":"2018","journal-title":"Association for the Advancement of Medical Instrumentation"},{"key":"10.1016\/j.ajic.2018.09.009_bib0060","doi-asserted-by":"crossref","first-page":"794","DOI":"10.1016\/j.ajic.2015.03.003","article-title":"Persistent contamination on colonoscopes and gastroscopes detected by biologic cultures and rapid indicators despite reprocessing performed in accordance with guidelines","volume":"43","author":"Ofstead","year":"2015","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2018.09.009_bib0061","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1016\/j.gie.2016.03.1480","article-title":"Surveillance of guideline practices for duodenoscope and linear echoendoscope reprocessing in a large healthcare system","volume":"84","author":"Brandabur","year":"2016","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.ajic.2018.09.009_bib0062","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/j.ajic.2016.01.017","article-title":"Practical toolkit for monitoring endoscope reprocessing effectiveness: identification of viable bacteria on gastroscopes, colonoscopes, and bronchoscopes","volume":"44","author":"Ofstead","year":"2016","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2018.09.009_bib0063","doi-asserted-by":"crossref","first-page":"191","DOI":"10.3389\/fmed.2017.00191","article-title":"Sterile reverse osmosis water combined with friction are optimal for channel and lever cavity sample collection of flexible duodenoscopes","volume":"4","author":"Alfa","year":"2017","journal-title":"Front Med"},{"key":"10.1016\/j.ajic.2018.09.009_bib0064","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1016\/j.gie.2017.05.014","article-title":"A novel polytetrafluoroethylene-channel model, which simulates low levels of culturable bacteria in buildup biofilm after repeated endoscope reprocessing","volume":"86","author":"Alfa","year":"2017","journal-title":"Gastrointest Endosc"}],"container-title":["American Journal of Infection Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0196655318309155?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0196655318309155?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T05:51:09Z","timestamp":1759297869000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0196655318309155"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3]]},"references-count":61,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019,3]]}},"alternative-id":["S0196655318309155"],"URL":"https:\/\/doi.org\/10.1016\/j.ajic.2018.09.009","relation":{},"ISSN":["0196-6553"],"issn-type":[{"value":"0196-6553","type":"print"}],"subject":[],"published":{"date-parts":[[2019,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Elevating the standard of endoscope processing: Terminal sterilization of duodenoscopes using a hydrogen peroxide\u2013ozone sterilizer","name":"articletitle","label":"Article Title"},{"value":"American Journal of Infection Control","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ajic.2018.09.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 The Author(s). Published by Elsevier Inc. on behalf of Association for Professionals in Infection Control and Epidemiology, Inc.","name":"copyright","label":"Copyright"}]}}