{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,10,20]],"date-time":"2024-10-20T04:03:48Z","timestamp":1729397028662,"version":"3.27.0"},"reference-count":33,"publisher":"Elsevier BV","issue":"11","license":[{"start":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T00:00:00Z","timestamp":1730419200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,11,1]],"date-time":"2024-11-01T00:00:00Z","timestamp":1730419200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","ajicjournal.org","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Journal of Infection Control"],"published-print":{"date-parts":[[2024,11]]},"DOI":"10.1016\/j.ajic.2024.06.020","type":"journal-article","created":{"date-parts":[[2024,6,28]],"date-time":"2024-06-28T18:21:34Z","timestamp":1719598894000},"page":"1302-1306","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Effectiveness of ceiling-mounted ultraviolet-C lamps: An experimental study in a biocontainment unit of a tertiary care hospital"],"prefix":"10.1016","volume":"52","author":[{"given":"Jeongyoung","family":"Lee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eun Ju","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Young-Ju","family":"Lim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eun Ok","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seongman","family":"Bae","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiwon","family":"Jung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sung-Han","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ajic.2024.06.020_bib1","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1097\/QCO.0b013e3283630f04","article-title":"The role of the surface environment in healthcare-associated infections","volume":"26","author":"Weber","year":"2013","journal-title":"Curr Opin Infect Dis"},{"issue":"3B","key":"10.1016\/j.ajic.2024.06.020_bib2","doi-asserted-by":"crossref","first-page":"179S","DOI":"10.1016\/0002-9343(91)90366-6","article-title":"Epidemiology and control of nosocomial infections in adult intensive care units","volume":"91","author":"Weinstein","year":"1991","journal-title":"Am J Med"},{"key":"10.1016\/j.ajic.2024.06.020_bib3","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1001\/archinternmed.2011.64","article-title":"Environmental cleaning intervention and risk of acquiring multidrug-resistant organisms from prior room occupants","volume":"171","author":"Datta","year":"2011","journal-title":"Arch Intern Med"},{"key":"10.1016\/j.ajic.2024.06.020_bib4","doi-asserted-by":"crossref","first-page":"1054","DOI":"10.1097\/CCM.0b013e3181cdf705","article-title":"Improving environmental hygiene in 27 intensive care units to decrease multidrug-resistant bacterial transmission","volume":"38","author":"Carling","year":"2010","journal-title":"Crit Care Med"},{"key":"10.1016\/j.ajic.2024.06.020_bib5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1086\/524329","article-title":"Identifying opportunities to enhance environmental cleaning in 23 acute care hospitals","volume":"29","author":"Carling","year":"2008","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2024.06.020_bib6","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1086\/588566","article-title":"Impact of an environmental cleaning intervention on the presence of methicillin-resistant Staphylococcus aureus and vancomycin-resistant enterococci on surfaces in intensive care unit rooms","volume":"29","author":"Goodman","year":"2008","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2024.06.020_bib7","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1007\/s11908-017-0585-6","article-title":"Practical approaches for assessment of daily and post-discharge room disinfection in healthcare facilities","volume":"19","author":"Deshpande","year":"2017","journal-title":"Curr Infect Dis Rep"},{"issue":"11S","key":"10.1016\/j.ajic.2024.06.020_bib8","doi-asserted-by":"crossref","first-page":"A134","DOI":"10.1016\/j.ajic.2023.04.003","article-title":"\u201cNo touch\u201d methods for health care room disinfection: focus on clinical trials","volume":"51","author":"Weber","year":"2023","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2024.06.020_bib9","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1017\/ice.2017.226","article-title":"No-touch disinfection methods to decrease multidrug-resistant organism infections: a systematic review and meta-analysis","volume":"39","author":"Marra","year":"2018","journal-title":"Infect Control Hosp Epidmiol"},{"key":"10.1016\/j.ajic.2024.06.020_bib10","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1164\/rccm.201501-0060OC","article-title":"Institutional tuberculosis transmission. Controlled trial of upper room ultraviolet air disinfection: a basis for new dosing guidelines","volume":"192","author":"Mphaphlele","year":"2015","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1016\/j.ajic.2024.06.020_bib11","doi-asserted-by":"crossref","first-page":"1692","DOI":"10.1016\/j.ajic.2016.07.004","article-title":"Efficacy of an automated ultraviolet C device in a shared hospital bathroom","volume":"44","author":"Cooper","year":"2016","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2024.06.020_bib12","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1097\/QCO.0000000000000284","article-title":"'No touch' technologies for environmental decontamination: focus on ultraviolet devices and hydrogen peroxide systems","volume":"29","author":"Weber","year":"2016","journal-title":"Curr Opin Infect Dis"},{"key":"10.1016\/j.ajic.2024.06.020_bib13","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1186\/s13756-022-01183-y","article-title":"The in situ efficacy of whole room disinfection devices: a literature review with practical recommendations for implementation","volume":"11","author":"van der Starre","year":"2022","journal-title":"Antimicrob Resist Infect Control"},{"key":"10.1016\/j.ajic.2024.06.020_bib14","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1016\/j.jmii.2017.08.017","article-title":"Effectiveness of an ultraviolet-C disinfection system for reduction of healthcare-associated pathogens","volume":"52","author":"Yang","year":"2019","journal-title":"J Microbiol Immunol Infect"},{"key":"10.1016\/j.ajic.2024.06.020_bib15","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1186\/1471-2334-10-197","article-title":"Evaluation of an automated ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms","volume":"10","author":"Nerandzic","year":"2010","journal-title":"BMC Infect Dis"},{"key":"10.1016\/j.ajic.2024.06.020_bib16","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0107444","article-title":"Sorting through the wealth of options: comparative evaluation of two ultraviolet disinfection systems","volume":"9","author":"Nerandzic","year":"2014","journal-title":"PLoS One"},{"key":"10.1016\/j.ajic.2024.06.020_bib17","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1086\/656244","article-title":"Room decontamination with UV radiation","volume":"31","author":"Rutala","year":"2010","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2024.06.020_bib18","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1016\/j.jhin.2013.05.005","article-title":"First UK evaluation of an automated ultraviolet-C room decontamination device (Tru-D\u2122)","volume":"84","author":"Mahida","year":"2013","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.ajic.2024.06.020_bib19","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1086\/670215","article-title":"Decontamination of targeted pathogens from patient rooms using an automated ultraviolet-C-emitting device","volume":"34","author":"Anderson","year":"2013","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2024.06.020_bib20","doi-asserted-by":"crossref","first-page":"1118","DOI":"10.1017\/ice.2018.165","article-title":"Enhanced disinfection leads to reduction of microbial contamination and a decrease in patient colonization and infection","volume":"39","author":"Rutala","year":"2018","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2024.06.020_bib21","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1016\/j.ajic.2015.10.016","article-title":"Postdischarge decontamination of MRSA, VRE, and Clostridium difficile isolation rooms using 2 commercially available automated ultraviolet-C-emitting devices","volume":"44","author":"Wong","year":"2016","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2024.06.020_bib22","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1016\/j.ajic.2017.10.025","article-title":"Efficacy of manual cleaning and an ultraviolet C room decontamination device in reducing health care-associated pathogens on hospital floors","volume":"46","author":"Mustapha","year":"2018","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2024.06.020_bib23","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1017\/ice.2017.126","article-title":"The effect of ultraviolet light on Clostridium difficile spore recovery versus bleach alone","volume":"38","author":"Liscynesky","year":"2017","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2024.06.020_bib24","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1017\/ice.2023.194","article-title":"Inactivation and\/or physical removal of Candida auris from floors by detergent cleaner, disinfectants, microfiber, and ultraviolet C light (UV-C)","volume":"45","author":"Rutala","year":"2024","journal-title":"Infect Control Hosp Epidmiol"},{"key":"10.1016\/j.ajic.2024.06.020_bib25","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1017\/ice.2021.214","article-title":"Inactivation of Candida auris and Candida albicans by ultraviolet-C","volume":"43","author":"Rutala","year":"2022","journal-title":"Infect Control Hosp Epidmiol"},{"key":"10.1016\/j.ajic.2024.06.020_bib26","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.jhin.2022.07.006","article-title":"Improvement and standardization of disinfection in hospital theatre with ultraviolet-C technology","volume":"128","author":"Bosco","year":"2022","journal-title":"J Hosp Infect"},{"year":"1997","key":"10.1016\/j.ajic.2024.06.020_bib27"},{"key":"10.1016\/j.ajic.2024.06.020_bib28","article-title":"Evaluation of the degradation of materials by exposure to germicide UV-C light through colorimetry, tensile strength and surface microstructure analyses","volume":"31","author":"Mitxelena-Iribarren","year":"2022","journal-title":"Mater Today Commun"},{"key":"10.1016\/j.ajic.2024.06.020_bib29","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0302258","article-title":"Shedding light on the problem: influence of the radiator power, source-sample distance, and exposure time on the performance of UV-C lamps in laboratory and real-world conditions","volume":"19","author":"Arkusz","year":"2024","journal-title":"PLoS One"},{"key":"10.1016\/j.ajic.2024.06.020_bib30","doi-asserted-by":"crossref","DOI":"10.1017\/S0950268823001371","article-title":"Effectiveness of ultraviolet-C disinfection systems for reduction of multi-drug resistant organism infections in healthcare settings: a systematic review and meta-analysis","volume":"151","author":"Sun","year":"2023","journal-title":"Epidemiol Infect"},{"key":"10.1016\/j.ajic.2024.06.020_bib31","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1093\/cid\/ciac776","article-title":"Effectiveness of ultraviolet-C disinfection on hospital-onset gram-negative rod bloodstream infection: a nationwide stepped-wedge time-series analysis","volume":"76","author":"Goto","year":"2023","journal-title":"Clin Infect Dis"},{"key":"10.1016\/j.ajic.2024.06.020_bib32","doi-asserted-by":"crossref","first-page":"805","DOI":"10.1016\/S0140-6736(16)31588-4","article-title":"Enhanced terminal room disinfection and acquisition and infection caused by multidrug-resistant organisms and Clostridium difficile (the Benefits of Enhanced Terminal Room Disinfection study): a cluster-randomised, multicentre, crossover study","volume":"389","author":"Anderson","year":"2017","journal-title":"Lancet"},{"key":"10.1016\/j.ajic.2024.06.020_bib33","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1093\/cid\/ciab896","article-title":"Ultraviolet-C light evaluation as adjunct disinfection to remove multidrug-resistant organisms","volume":"75","author":"Rock","year":"2022","journal-title":"Clin Infect Dis"}],"container-title":["American Journal of Infection Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0196655324005819?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0196655324005819?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,10,19]],"date-time":"2024-10-19T06:54:41Z","timestamp":1729320881000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0196655324005819"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11]]},"references-count":33,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2024,11]]}},"alternative-id":["S0196655324005819"],"URL":"https:\/\/doi.org\/10.1016\/j.ajic.2024.06.020","relation":{},"ISSN":["0196-6553"],"issn-type":[{"type":"print","value":"0196-6553"}],"subject":[],"published":{"date-parts":[[2024,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effectiveness of ceiling-mounted ultraviolet-C lamps: An experimental study in a biocontainment unit of a tertiary care hospital","name":"articletitle","label":"Article Title"},{"value":"American Journal of Infection Control","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ajic.2024.06.020","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Published by Elsevier Inc. on behalf of Association for Professionals in Infection Control and Epidemiology, Inc.","name":"copyright","label":"Copyright"}]}}