{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T19:44:00Z","timestamp":1786218240017,"version":"build-2736575974"},"reference-count":72,"publisher":"Elsevier BV","issue":"9","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T00:00:00Z","timestamp":1771200000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000738","name":"US Department of Veterans Affairs","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000738","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["ajicjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Journal of Infection Control"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1016\/j.ajic.2026.02.007","type":"journal-article","created":{"date-parts":[[2026,8,5]],"date-time":"2026-08-05T16:44:54Z","timestamp":1785948294000},"page":"S25-S33","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"S","title":["In search of the holy grail of environmental cleaning and disinfection: Effective and safe continuous air and surface disinfection technologies"],"prefix":"10.1016","volume":"54","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0990-4498","authenticated-orcid":false,"given":"Curtis J.","family":"Donskey","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ajic.2026.02.007_bib1","doi-asserted-by":"crossref","first-page":"A144","DOI":"10.1016\/j.ajic.2023.03.017","article-title":"Continuous surface and air decontamination technologies: current concepts and controversies","volume":"51","author":"Donskey","year":"2023","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib2","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1001\/jama.2022.9970","article-title":"Reducing SARS-CoV-2 in shared indoor air","volume":"328","author":"Dowell","year":"2022","journal-title":"JAMA"},{"key":"10.1016\/j.ajic.2026.02.007_bib3","unstructured":"Centers for Disease Control and Prevention. Measles cases and outbreaks. Accessed December 1, 2025.\u200b https:\/\/www.cdc.gov\/measles\/data-research\/index.html."},{"key":"10.1016\/j.ajic.2026.02.007_bib4","unstructured":"Centers for Disease Control and Prevention. H5N1 bird flu: current situation summary. Accessed December 1, 2025. https:\/\/www.cdc.gov\/bird-flu\/situation-summary\/index.html."},{"key":"10.1016\/j.ajic.2026.02.007_bib5","doi-asserted-by":"crossref","first-page":"A90","DOI":"10.1016\/j.ajic.2019.03.017","article-title":"Beyond high-touch surfaces: portable equipment and floors as potential sources of transmission of health care-associated pathogens","volume":"47S","author":"Donskey","year":"2019","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib6","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1007\/s11908-017-0585-6","article-title":"Practical approaches for assessment of daily and post-discharge room disinfection in healthcare facilities","volume":"19","author":"Deshpande","year":"2017","journal-title":"Curr Infect Dis Rep"},{"key":"10.1016\/j.ajic.2026.02.007_bib7","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1086\/674852","article-title":"More cleaning, less screening: evaluation of the time required for monitoring versus performing environmental cleaning","volume":"35","author":"Kundrapu","year":"2014","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib8","doi-asserted-by":"crossref","first-page":"1276","DOI":"10.1093\/cid\/ciad752","article-title":"Rapid environmental contamination with Candida auris and multidrug-resistant bacterial pathogens near colonized patients","volume":"78","author":"Sansom","year":"2024","journal-title":"Clin Infect Dis"},{"key":"10.1016\/j.ajic.2026.02.007_bib9","doi-asserted-by":"crossref","first-page":"1076","DOI":"10.1017\/ice.2020.1367","article-title":"Timing and route of contamination of hospitalized patient rooms with healthcare-associated pathogens","volume":"42","author":"Redmond","year":"2021","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib10","unstructured":"Centers for Disease Control and Prevention. Air: guidelines for environmental infection control in healthcare facilities. Accessed June 16, 2025. https:\/\/www.cdc.gov\/infectioncontrol\/guidelines\/environmental\/background\/air.html."},{"key":"10.1016\/j.ajic.2026.02.007_bib11","doi-asserted-by":"crossref","first-page":"1747","DOI":"10.1093\/cid\/ciab722","article-title":"A paradigm shift to align transmission routes with mechanisms","volume":"73","author":"Marr","year":"2021","journal-title":"Clin Infect Dis"},{"key":"10.1016\/j.ajic.2026.02.007_bib12","doi-asserted-by":"crossref","first-page":"A126","DOI":"10.1016\/j.ajic.2023.03.007","article-title":"High technology and low technology measures to reduce risk of SARS-CoV-2 transmission","volume":"51","author":"Donskey","year":"2023","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib13","doi-asserted-by":"crossref","first-page":"2128","DOI":"10.1093\/cid\/ciac334","article-title":"Airflow patterns in double-occupancy patient rooms may contribute to roommate-to-roommate transmission of severe acute respiratory syndrome coronavirus 2","volume":"75","author":"Cadnum","year":"2022","journal-title":"Clin Infect Dis"},{"key":"10.1016\/j.ajic.2026.02.007_bib14","article-title":"Impacts of lid closure during toilet flushing and of toilet bowl cleaning on viral contamination of surfaces in United States restrooms","author":"Goforth","year":"2023","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib15","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1016\/j.ajic.2024.03.013","volume":"52","author":"Trosch","year":"2024","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib16","unstructured":"American Conference of Governmental Industrial Hygienists (ACGIH). Ultraviolet radiation TLVs and BEIs; 2022. \u3008https:\/\/www.acgih.org\/science\/tlv-bei-guidelines\/\u3009."},{"key":"10.1016\/j.ajic.2026.02.007_bib17","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.ajic.2019.08.003","article-title":"Efficacy of an ultraviolet-A lighting system for continuous decontamination of health care-associated pathogens on surfaces","volume":"48","author":"Livingston","year":"2020","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib18","doi-asserted-by":"crossref","DOI":"10.6028\/jres.126.052","article-title":"Inactivation of pathogens in air using ultraviolet direct irradiation below exposure limits","volume":"126","author":"Allen","year":"2022","journal-title":"J Res Natl Inst Stand Technol"},{"key":"10.1016\/j.ajic.2026.02.007_bib19","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1080\/10643389.2022.2084315","article-title":"Far UV-C radiation: an emerging tool for pandemic control","volume":"53","author":"Blatchley","year":"2022","journal-title":"Crit Rev Environ Sci Technol"},{"key":"10.1016\/j.ajic.2026.02.007_bib20","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.1017\/ice.2018.200","article-title":"Antimicrobial activity of a continuous visible light disinfection system","volume":"39","author":"Rutala","year":"2018","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib21","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1017\/ice.2023.159","article-title":"Efficacy of a far-ultraviolet-C light technology for continuous decontamination of air and surfaces","volume":"45","author":"Memic","year":"2024","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib22","article-title":"The impact of far-UVC radiation (200-230 nm) on pathogens, cells, skin, and eyes - a collection and analysis of a hundred years of data","volume":"16","author":"Hessling","year":"2021","journal-title":"GMS Hyg Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib23","doi-asserted-by":"crossref","first-page":"1343","DOI":"10.1111\/php.14052","article-title":"Ocular safety of 222-nm far-ultraviolet-C full-room germicidal irradiation: a 36-month clinical observation","volume":"101","author":"Sugihara","year":"2025","journal-title":"Photochem Photobiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib24","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1111\/php.14016","article-title":"Interventional human ocular safety experiments for 222-nm far-ultraviolet-C lamp irradiation","volume":"101","author":"Sugihara","year":"2025","journal-title":"Photochem Photobiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib25","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1111\/php.13866","article-title":"Assessing the safety of new germicidal far-UVC technologies","volume":"100","author":"G\u00f6rlitz","year":"2024","journal-title":"Photochem Photobiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib26","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0235948","article-title":"Exploratory clinical trial on the safety and bactericidal effect of 222-nm ultraviolet C irradiation in healthy humans","volume":"15","author":"Fukui","year":"2020","journal-title":"PLoS One"},{"key":"10.1016\/j.ajic.2026.02.007_bib27","unstructured":"German Commission on Radiological Protection. Risks of using far UV-C radiation in the presence of people. \u3008https:\/\/www.ssk.de\/SharedDocs\/Beratungsergebnisse\/EN\/2023\/2023\u201312-08_Empf_Fern-UVC-Strlg_Desinfek.pdf?__blob=publicationFile&v=5\u3009."},{"key":"10.1016\/j.ajic.2026.02.007_bib28","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1111\/phpp.12156","article-title":"The effect of 222-nm UVC phototesting on healthy volunteer skin: a pilot study","volume":"31","author":"Woods","year":"2015","journal-title":"Photodermatol Photoimmunol Photomed"},{"key":"10.1016\/j.ajic.2026.02.007_bib29","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-025-02869-0","article-title":"Far-ultraviolet light causes direct DNA damage in human lung cells and tissues","volume":"15","author":"Valanciute","year":"2025","journal-title":"Sci Rep"},{"key":"10.1016\/j.ajic.2026.02.007_bib30","doi-asserted-by":"crossref","first-page":"9112","DOI":"10.3390\/ijms23169112","article-title":"222-nanometer far-UVC exposure results in DNA damage and transcriptional changes to mammalian cells","volume":"23","author":"Ong","year":"2022","journal-title":"Int J Mol Sci"},{"key":"10.1016\/j.ajic.2026.02.007_bib31","unstructured":"Link, M., Shore, A., Robertson, R., Hamadani, B., Poppendieck, D. Spectral characteristics and indoor air quality effects of germicidal 254 nm and 222 nm ultraviolet light, NIST Interagency\/Internal Report (NISTIR), National Institute of Standards and Technology, Gaithersburg, MD. \u3008https:\/\/tsapps.nist.gov\/publication\/get_pdf.cfm?pub_id=958820\u3009."},{"key":"10.1016\/j.ajic.2026.02.007_bib32","first-page":"1","article-title":"Do far ultraviolet-C light technologies increase ozone concentrations in healthcare facility patient rooms?","author":"Memic","year":"2025","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib33","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1016\/j.envint.2018.07.012","article-title":"Human exposure to ozone in school and office indoor environments","volume":"119","author":"Salonen","year":"2018","journal-title":"Environ Int"},{"key":"10.1016\/j.ajic.2026.02.007_bib34","first-page":"1","article-title":"Evaluation of a wall-mounted far ultraviolet-C light device used for continuous air and surface decontamination in a dental office during routine patient care","author":"Osborne","year":"2024","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib35","article-title":"A novel approach for safe and automated implementation of far ultraviolet-C light decontamination in clinical areas","volume":"4","author":"Memic","year":"2024","journal-title":"Antimicrob Steward Healthc Epidemiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib36","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/j.ajic.2024.12.011","article-title":"Evaluation of a far ultraviolet-C device for decontamination of portable equipment in clinical areas","volume":"53","author":"Memic","year":"2025","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib37","first-page":"1","article-title":"A ceiling-mounted far-ultraviolet-C light technology reduces methicillin-resistant Staphylococcus aureus contamination on surfaces in a simulated operating room","author":"Memic","year":"2025","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib38","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1186\/s13756-024-01473-7","article-title":"Evaluation of an automated far ultraviolet-C light technology for decontamination of surfaces and aerosolized viruses in bathrooms","volume":"13","author":"Kaple","year":"2024","journal-title":"Antimicrob Resist Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib39","first-page":"1","article-title":"A far ultraviolet-C light technology is effective for decontamination of items in proximity to sinks and is enhanced by a far UV-C reflective surface","author":"Kaple","year":"2024","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib40","doi-asserted-by":"crossref","first-page":"156","DOI":"10.20411\/pai.v9i1.683","article-title":"Evaluation of an automated wall-mounted far ultraviolet-C light technology for continuous or intermittent decontamination of Candida auris on surfaces","volume":"9","author":"Memic","year":"2024","journal-title":"Pathog Immun"},{"key":"10.1016\/j.ajic.2026.02.007_bib41","doi-asserted-by":"crossref","first-page":"87","DOI":"10.20411\/pai.v10i2.801","article-title":"Evaluation of far ultraviolet-C light for decontamination of organisms in whole milk and chicken manure","volume":"10","author":"Memic","year":"2025","journal-title":"Pathog Immun"},{"key":"10.1016\/j.ajic.2026.02.007_bib42","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1017\/ice.2025.62","article-title":"Ceiling-mounted far-UVC fixtures reduce the surface bioburden in occupied clinical areas","volume":"46","author":"Mogensen","year":"2025","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib43","article-title":"Efficacy of an upper room ultraviolet-C (UV-C) technology versus far UV-C light technologies in reducing aerosolized bacteriophage MS2","volume":"5","author":"Memic","year":"2025","journal-title":"Antimicrob Steward Healthc Epidemiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib44","unstructured":"United States Environmental Protection Agency. Residential air cleaners: a technical summary. EPA 402-F-09\u2013002. 2018. Accessed December 1, 2025. file:\/\/\/U:\/Coronavirus%20transmission%20airborne\/EPA%20residential_air_cleaners_-_a_technical_summary_3rd_edition.pdf."},{"key":"10.1016\/j.ajic.2026.02.007_bib45","unstructured":"American Society of Heating, Refrigerating and Air-Conditioning Engineers. ASHRAE Position Document on Filtration and Air Cleaning. \u3008https:\/\/www.ashrae.org\/file%20library\/about\/position%20documents\/filtration-and-air-cleaning-pd-feb.2.2021.pdf\u3009."},{"key":"10.1016\/j.ajic.2026.02.007_bib46","unstructured":"Centers for Disease Control and Prevention. Ventilation in buildings; 2023. Accessed December 1, 2025. https:\/\/archive.cdc.gov\/www_cdc_gov\/coronavirus\/2019-ncov\/community\/ventilation.html."},{"key":"10.1016\/j.ajic.2026.02.007_bib47","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1016\/j.ajic.2025.02.008","article-title":"Advanced photohydrolysis technology demonstrates rapid inactivation of aerosolized SARS-CoV-2 and efficacy against other respiratory viral pathogens","volume":"53","author":"Peel","year":"2025","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib48","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1016\/j.nano.2019.03.003","article-title":"Inactivation of common hospital acquired pathogens on surfaces and in air utilizing engineered water nanostructures (EWNS) based nano-sanitizers","volume":"18","author":"Vaze","year":"2019","journal-title":"Nanomedicine"},{"issue":"suppl 1","key":"10.1016\/j.ajic.2026.02.007_bib49","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1289\/ehp.97105s1165","article-title":"The role of oxygen free radicals in occupational and environmental lung diseases","volume":"105","author":"Vallyathan","year":"1997","journal-title":"Environ Health Perspect"},{"key":"10.1016\/j.ajic.2026.02.007_bib50","unstructured":"Zaatari M., Harmon M. Open letter to address the use of electronic air cleaning equipment in buildings. Accessed December 1, 2025. https:\/\/medium.com\/open-letter-to-address-the-use-of-electronic-air\/no-to-ionizers-plasma-uvpco-bc1570b2fb9b."},{"key":"10.1016\/j.ajic.2026.02.007_bib51","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0307031","article-title":"Evaluate the safety of a novel photohydrolysis technology used to clean and disinfect indoor air: a murine study","volume":"19","author":"Selitrennikoff","year":"2024","journal-title":"PLoS One"},{"key":"10.1016\/j.ajic.2026.02.007_bib52","unstructured":"Synexis\u00ae Sphere Carbon Filter - Continuous Air Purification Technology. Accessed December 1, 2025. https:\/\/products.solenis.com\/product\/synexisr-sphere-carbon-filter-1ea-continuous-air-purification-technology-TR-M7008."},{"key":"10.1016\/j.ajic.2026.02.007_bib53","doi-asserted-by":"crossref","first-page":"1438","DOI":"10.1017\/ice.2019.261","article-title":"Evaluation of dilute hydrogen peroxide technology for continuous room decontamination of multidrug-resistant organisms","volume":"40","author":"Rutala","year":"2019","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib54","doi-asserted-by":"crossref","DOI":"10.1017\/ice.2019.379","article-title":"Re: evaluation of dilute hydrogen peroxide technology for continuous room decontamination of multidrug-resistant organisms","volume":"41","author":"Schlote","year":"2020","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib55","doi-asserted-by":"crossref","first-page":"1252","DOI":"10.1016\/j.ajic.2021.07.006","article-title":"Treatment with dry hydrogen peroxide accelerates the decay of severe acute syndrome coronavirus-2 on non-porous hard surfaces","volume":"49","author":"Huang","year":"2021","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib56","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.jhin.2011.03.003","article-title":"Environmental contamination and airborne microbial counts: a role for hydroxyl radical disinfection units?","volume":"78","author":"Wong","year":"2011","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.ajic.2026.02.007_bib57","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.idh.2019.12.005","article-title":"Measuring environmental contamination in critical care using dilute hydrogen peroxide (DHP) technology: an observational cross-over study","volume":"25","author":"Oon","year":"2020","journal-title":"Infect Dis Health"},{"key":"10.1016\/j.ajic.2026.02.007_bib58","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1016\/j.ajic.2021.03.004","article-title":"Evaluation of dry hydrogen peroxide in reducing microbial bioburden in a healthcare facility","volume":"49","author":"Sanguinet","year":"2021","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib59","doi-asserted-by":"crossref","first-page":"1337","DOI":"10.1016\/j.ajic.2021.06.004","article-title":"An effective and automated approach for reducing infection risk from contaminated privacy curtains","volume":"49","author":"Sanguinet","year":"2021","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib60","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1016\/j.ajic.2020.08.026","article-title":"Effectiveness of dry hydrogen peroxide on reducing environmental microbial bioburden risk in a pediatric oncology intensive care unit","volume":"49","author":"Ramirez","year":"2021","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib61","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1016\/j.ajic.2021.12.010","article-title":"Impact of dry hydrogen peroxide on hospital-acquired infection at a pediatric oncology hospital","volume":"50","author":"Melgar","year":"2022","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib62","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1017\/ice.2023.153","article-title":"Effectiveness of dry hydrogen peroxide in reducing air and surface bioburden in a multicenter clinical setting","volume":"45","author":"Wright","year":"2024","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib63","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1093\/cid\/ciae237","article-title":"More high-quality evidence curbing our enthusiasm for enhanced terminal decontamination of hospital rooms with no-touch technologies: is it lights out for UV-C?","volume":"79","author":"Goto","year":"2024","journal-title":"Clin Infect Dis"},{"key":"10.1016\/j.ajic.2026.02.007_bib64","doi-asserted-by":"crossref","first-page":"3045","DOI":"10.1111\/risa.70054","article-title":"Managing infectious aerosols to counter engineered pandemics: current recommendations and future research","volume":"45","author":"Lerner","year":"2025","journal-title":"Risk Anal"},{"key":"10.1016\/j.ajic.2026.02.007_bib65","doi-asserted-by":"crossref","DOI":"10.1093\/jambio\/lxae071","article-title":"Reviewing the evidence of antimicrobial activity of glycols","volume":"135","author":"Duggan","year":"2024","journal-title":"J Appl Microbiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib66","doi-asserted-by":"crossref","first-page":"2040","DOI":"10.1093\/infdis\/jiac394","article-title":"Triethylene glycol can be predeployed as a safe virus-killing indoor air treatment","volume":"226","author":"Goldman","year":"2022","journal-title":"J Infect Dis"},{"key":"10.1016\/j.ajic.2026.02.007_bib67","doi-asserted-by":"crossref","DOI":"10.15252\/emmm.202317932","article-title":"Propylene glycol inactivates respiratory viruses and prevents airborne transmission","volume":"15","author":"Styles","year":"2023","journal-title":"EMBO Mol Med"},{"key":"10.1016\/j.ajic.2026.02.007_bib68","doi-asserted-by":"crossref","DOI":"10.1128\/aem.02335-25","article-title":"Inactivation of airborne pathogen surrogates by triethylene glycol","volume":"92","author":"Desai","year":"2026","journal-title":"Appl Environ Microbiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib69","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1016\/j.ajic.2025.04.008","article-title":"The impact of an air sanitizer spray on the risk of virus transmission by aerosols generated by toilet flushing","volume":"53","author":"Boone","year":"2025","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.02.007_bib70","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1111\/lam.13109","article-title":"A quantitative method to assess the role of indoor air decontamination to simultaneously reduce contamination of environmental surfaces: testing with vegetative and spore-forming bacteria","volume":"68","author":"Zargar","year":"2019","journal-title":"Lett Appl Microbiol"},{"key":"10.1016\/j.ajic.2026.02.007_bib71","doi-asserted-by":"crossref","first-page":"6459","DOI":"10.1007\/s00253-018-9088-0","article-title":"Decontaminating surfaces with atomized disinfectants generated by a novel thickness-mode lithium niobate device","volume":"102","author":"Kumaraswamy","year":"2018","journal-title":"Appl Microbiol Biotechnol"},{"key":"10.1016\/j.ajic.2026.02.007_bib72","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1016\/j.ajic.2009.06.007","article-title":"Inactivating influenza viruses on surfaces using hydrogen peroxide or triethylene glycol at low vapor concentrations","volume":"37","author":"Rudnick","year":"2009","journal-title":"Am J Infect Control"}],"container-title":["American Journal of Infection Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0196655326000908?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0196655326000908?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T19:27:49Z","timestamp":1786217269000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0196655326000908"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9]]},"references-count":72,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["S0196655326000908"],"URL":"https:\/\/doi.org\/10.1016\/j.ajic.2026.02.007","relation":{},"ISSN":["0196-6553"],"issn-type":[{"value":"0196-6553","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"In search of the holy grail of environmental cleaning and disinfection: Effective and safe continuous air and surface disinfection technologies","name":"articletitle","label":"Article Title"},{"value":"American Journal of Infection Control","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ajic.2026.02.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Published by Elsevier Inc. on behalf of Association for Professionals in Infection Control and Epidemiology, Inc.","name":"copyright","label":"Copyright"}]}}