{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T18:01:52Z","timestamp":1789754512662,"version":"4.0.1"},"reference-count":26,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100008867","name":"Zhejiang Province Department of Education","doi-asserted-by":"publisher","award":["Y202249990"],"award-info":[{"award-number":["Y202249990"]}],"id":[{"id":"10.13039\/501100008867","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["ajicjournal.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Journal of Infection Control"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1016\/j.ajic.2026.09.003","type":"journal-article","created":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T15:42:16Z","timestamp":1788882136000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparative evaluation of filters for sustained bacterial control in endoscope reprocessing final rinse water"],"prefix":"10.1016","author":[{"given":"Pan","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ChenYing","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mei","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"LiNa","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2292-2893","authenticated-orcid":false,"given":"Qing","family":"Gu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ajic.2026.09.003_bib1","doi-asserted-by":"crossref","first-page":"899","DOI":"10.14309\/ajg.0000000000001245","article-title":"ACG clinical guideline: upper gastrointestinal and ulcer bleeding","volume":"116","author":"Laine","year":"2021","journal-title":"Am J Gastroenterol"},{"key":"10.1016\/j.ajic.2026.09.003_bib2","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1055\/a-2304-3219","article-title":"Colorectal polypectomy and endoscopic mucosal resection: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2024","volume":"56","author":"Ferlitsch","year":"2024","journal-title":"Endoscopy"},{"key":"10.1016\/j.ajic.2026.09.003_bib3","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1016\/j.gie.2018.10.001","article-title":"ASGE guideline on the role of endoscopy in the evaluation and management of choledocholithiasis","volume":"89","author":"Buxbaum","year":"2019","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.ajic.2026.09.003_bib4","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.gie.2020.09.048","article-title":"Multisociety guideline on reprocessing flexible GI endoscopes and accessories","volume":"93","author":"Day","year":"2021","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.ajic.2026.09.003_bib5","unstructured":"Association for the Advancement of Medical Instrumentation2021. ANSI\/AAMI ST91:2021: flexible and semi-rigid endoscope processing in health care facilities."},{"key":"10.1016\/j.ajic.2026.09.003_bib6","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/MCG.0000000000001759","article-title":"WGO guideline-endoscope disinfection update","volume":"57","author":"Speer","year":"2023","journal-title":"J Clin Gastroenterol"},{"key":"10.1016\/j.ajic.2026.09.003_bib7","unstructured":"ECRI. 2020 Top 10 Health Technology Hazards Executive Brief[EB\/OL].(2020-03-07)[2025-09-03]. https:\/\/www.ecri.org\/landing-2020-top-ten-health-technology-hazards\/."},{"key":"10.1016\/j.ajic.2026.09.003_bib8","unstructured":"ECRI. Top 10 Health Technology Hazards for 2022 Executive Brief[EB\/OL].(2022-01-18)[2025-09-03]. https:\/\/www.ecri.org\/top-10-health-technology-hazards-2022-executive-brief\/."},{"key":"10.1016\/j.ajic.2026.09.003_bib9","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.jhin.2025.11.025","article-title":"Silent transmission of clonal Pseudomonas aeruginosa via duodenoscopes: microbiological and genomic investigation of a prolonged episode","volume":"169","author":"Ciss\u00e9","year":"2026","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.ajic.2026.09.003_bib10","doi-asserted-by":"crossref","first-page":"e638","DOI":"10.1093\/cid\/ciaa1887","article-title":"Outbreak of Pseudomonas aeruginosa infections from a contaminated gastroscope detected by whole genome sequencing surveillance","volume":"73","author":"Sundermann","year":"2021","journal-title":"Clin Infect Dis"},{"key":"10.1016\/j.ajic.2026.09.003_bib11","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1128\/CMR.00085-12","article-title":"Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy","volume":"26","author":"Kovaleva","year":"2013","journal-title":"Clin Microbiol Rev"},{"key":"10.1016\/j.ajic.2026.09.003_bib12","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1055\/a-0759-1629","volume":"50","author":"Beilenhoff","year":"2018","journal-title":"Endoscopy"},{"key":"10.1016\/j.ajic.2026.09.003_bib13","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.ajic.2019.06.013","article-title":"Bronchoscope-related Pseudomonas aeruginosa pseudo-outbreak attributed to contaminated rinse water","volume":"48","author":"Zhang","year":"2020","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.09.003_bib14","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.jhin.2022.02.022","article-title":"Final rinse water quality for flexible endoscopy to minimize the risk of post-endoscopic infection. Report from Healthcare Infection Society Working Party","volume":"124","author":"Walker","year":"2022","journal-title":"J Hosp Infect"},{"key":"10.1016\/j.ajic.2026.09.003_bib15","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.ajic.2019.07.008","article-title":"The importance of sampling technique and rinse water for assessing flexible gastrointestinal endoscope reprocessing: a 3-year study covering 59 centers","volume":"48","author":"Ji","year":"2020","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.ajic.2026.09.003_bib16","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13756-025-01560-3","article-title":"Management and microbial monitoring of final rinse water for flexible endoscopes in 290 hospitals in Jiangsu Province, China: a multicenter cross-sectional study","volume":"14","author":"Li","year":"2025","journal-title":"Antimicrob Resist Infect Control"},{"key":"10.1016\/j.ajic.2026.09.003_bib17","first-page":"1","article-title":"Comparative evaluation of the performance of sterile filters for bioburden protection and final fill in biopharmaceutical processes","volume":"12","author":"Na","year":"2022","journal-title":"Membr (Basel)"},{"key":"10.1016\/j.ajic.2026.09.003_bib18","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1017\/ice.2025.41","article-title":"Multisociety guidance for sterilization and high-level disinfection","volume":"46","author":"Shenoy","year":"2025","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.ajic.2026.09.003_bib19","doi-asserted-by":"crossref","DOI":"10.7717\/peerj.20134","article-title":"Factors influencing compliance with endoscopy final rinsing water standards: a study in a tertiary hospital setting","volume":"13","author":"Yuan","year":"2025","journal-title":"PeerJ"},{"key":"10.1016\/j.ajic.2026.09.003_bib20","doi-asserted-by":"crossref","first-page":"307","DOI":"10.5731\/pdajpst.2015.01026","article-title":"Evaluation of the effect of the volume throughput and maximum flux of low-surface-tension fluids on bacterial penetration of 0.2 micron-rated filters during process-specific filter validation testing","volume":"69","author":"Folmsbee","year":"2015","journal-title":"PDA J Pharm Sci Technol"},{"key":"10.1016\/j.ajic.2026.09.003_bib21","doi-asserted-by":"crossref","first-page":"881","DOI":"10.3201\/eid0809.020063","article-title":"Biofilms: microbial life on surfaces","volume":"8","author":"Donlan","year":"2002","journal-title":"Emerg Infect Dis"},{"key":"10.1016\/j.ajic.2026.09.003_bib22","first-page":"65","article-title":"Retention of water-borne bacteria by membrane filters part I: bacterial challenge tests on 0.2 and 0.22 micron rated filters","volume":"55","author":"Sundaram","year":"2001","journal-title":"PDA J Pharm Sci Technol"},{"key":"10.1016\/j.ajic.2026.09.003_bib23","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1007\/s40201-020-00577-7","article-title":"Isolation, identification and reviewing the health effect of HPC bacteria in household point-of-use (PoU) water treatment devices: a case study, Ahvaz, Iran","volume":"19","author":"Talepour","year":"2021","journal-title":"J Environ Health Sci Eng"},{"key":"10.1016\/j.ajic.2026.09.003_bib24","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1055\/a-0759-1629","volume":"50","author":"Beilenhoff","year":"2018","journal-title":"Endoscopy"},{"key":"10.1016\/j.ajic.2026.09.003_bib25","article-title":"Role of hypobromous acid in the transformation of polycyclic aromatic hydrocarbons during chlorination","volume":"210","author":"Li","year":"2022","journal-title":"Water Res"},{"key":"10.1016\/j.ajic.2026.09.003_bib26","unstructured":"National Toxicology Program15th Report on Carcinogens. U.S. Department of Health and Human Services2021. Accessed July 10, 2026. https:\/\/ntp.niehs.nih.gov\/research\/assessments\/cancer\/roc."}],"container-title":["American Journal of Infection Control"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0196655326006887?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0196655326006887?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T17:01:54Z","timestamp":1789750914000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0196655326006887"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9]]},"references-count":26,"alternative-id":["S0196655326006887"],"URL":"https:\/\/doi.org\/10.1016\/j.ajic.2026.09.003","relation":{},"ISSN":["0196-6553"],"issn-type":[{"value":"0196-6553","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparative evaluation of filters for sustained bacterial control in endoscope reprocessing final rinse water","name":"articletitle","label":"Article Title"},{"value":"American Journal of Infection Control","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ajic.2026.09.003","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}]}}