{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T01:42:42Z","timestamp":1768786962785,"version":"3.49.0"},"reference-count":23,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2013,12,1]],"date-time":"2013-12-01T00:00:00Z","timestamp":1385856000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2013,12,1]],"date-time":"2013-12-01T00:00:00Z","timestamp":1385856000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["ajo.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Journal of Ophthalmology"],"published-print":{"date-parts":[[2013,12]]},"DOI":"10.1016\/j.ajo.2013.07.028","type":"journal-article","created":{"date-parts":[[2013,9,25]],"date-time":"2013-09-25T08:17:58Z","timestamp":1380097078000},"page":"1134-1140.e4","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":12,"title":["Detection and Influencing Factors of Capsular Bag Distention Syndrome after Cataract Surgery Using the Pentacam Scheimpflug System"],"prefix":"10.1016","volume":"156","author":[{"given":"Xiangjia","family":"Zhu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yi","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.ajo.2013.07.028_bib1","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/S0886-3350(13)80883-8","article-title":"Capsular bag distension after endophacoemulsification and posterior chamber intraocular lens implantation","volume":"16","author":"Davison","year":"1990","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"10.1016\/j.ajo.2013.07.028_bib2","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/j.jcrs.2007.11.026","article-title":"Capsular block syndrome after cataract surgery: clinical analysis and classification","volume":"34","author":"Kim","year":"2008","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"10.1016\/j.ajo.2013.07.028_bib3","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1016\/S0886-3350(13)80340-9","article-title":"Postoperative complications of capsulorhexis","volume":"19","author":"Masket","year":"1993","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"10.1016\/j.ajo.2013.07.028_bib4","doi-asserted-by":"crossref","first-page":"1083","DOI":"10.1016\/j.ajo.2006.06.055","article-title":"Scheimpflug imaging in late capsular bag distention syndrome after phacoemulsification","volume":"142","author":"Jain","year":"2006","journal-title":"Am J Ophthalmol"},{"issue":"9","key":"10.1016\/j.ajo.2013.07.028_bib5","doi-asserted-by":"crossref","first-page":"1230","DOI":"10.1016\/S0886-3350(98)80017-5","article-title":"New classification of capsular block syndrome","volume":"24","author":"Miyake","year":"1998","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"10.1016\/j.ajo.2013.07.028_bib6","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1016\/S0002-9394(99)80182-2","article-title":"Liquefied after cataract: a complication of continuous curvilinear capsulorhexis and intraocular lens implantation in the lens capsule","volume":"125","author":"Miyake","year":"1998","journal-title":"Am J\u00a0Ophthalmol"},{"issue":"4","key":"10.1016\/j.ajo.2013.07.028_bib7","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/S0002-9394(99)80195-0","article-title":"Capsular bag distention syndrome noted 5 years after intraocular lens implantation","volume":"125","author":"Nishi","year":"1998","journal-title":"Am J Ophthalmol"},{"issue":"3","key":"10.1016\/j.ajo.2013.07.028_bib8","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1016\/S0886-3350(99)00430-7","article-title":"Analysis of liquid accumulated in the distended capsular bag in early postoperative capsular block syndrome","volume":"26","author":"Sugiura","year":"2000","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"10.1016\/j.ajo.2013.07.028_bib9","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1016\/j.jcrs.2007.01.023","article-title":"Phacoanaphylactic endophthalmitis secondary to capsular block syndrome","volume":"33","author":"Mardelli","year":"2007","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"10.1016\/j.ajo.2013.07.028_bib10","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1016\/S0886-3350(99)00434-4","article-title":"Early postoperative capsular block syndrome related to saccadic-eye-movement-induced fluid flow into the capsular bag","volume":"26","author":"Zacharias","year":"2000","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"10.1016\/j.ajo.2013.07.028_bib11","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.1016\/S0886-3350(01)01123-3","article-title":"Capsular block syndrome associated with horizontal jerk nystagmus","volume":"28","author":"Tognetto","year":"2002","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"10.1016\/j.ajo.2013.07.028_bib12","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1097\/OPX.0b013e31818e8ceb","article-title":"Anterior chamber depth measurement in phakic and pseudophakic eyes","volume":"85","author":"Su","year":"2008","journal-title":"Optom Vis Sci"},{"issue":"11","key":"10.1016\/j.ajo.2013.07.028_bib13","doi-asserted-by":"crossref","first-page":"2071","DOI":"10.1016\/j.jcrs.2011.08.023","article-title":"Imaging late capsular block syndrome: ultrasound biomicroscopy versus Scheimpflug camera","volume":"37","author":"Kucukevcilioglu","year":"2011","journal-title":"J Cataract Refract Surg"},{"issue":"11","key":"10.1016\/j.ajo.2013.07.028_bib14","doi-asserted-by":"crossref","first-page":"2448","DOI":"10.1016\/j.jcrs.2004.07.005","article-title":"Assessment of capsular block syndrome with anterior segment optical coherence tomography","volume":"30","author":"Baikoff","year":"2004","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"10.1016\/j.ajo.2013.07.028_bib15","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1016\/S0161-6420(00)00020-8","article-title":"Ultrasonographic measurement of induced myopia associated with capsular bag distention syndrome","volume":"107","author":"Sorenson","year":"2000","journal-title":"Ophthalmology"},{"issue":"9","key":"10.1016\/j.ajo.2013.07.028_bib16","doi-asserted-by":"crossref","first-page":"1575","DOI":"10.1016\/j.jcrs.2009.04.028","article-title":"Intraocular lens power calculation and optimized constants for highly myopic eyes","volume":"35","author":"Petermeier","year":"2009","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"10.1016\/j.ajo.2013.07.028_bib17","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1016\/S0886-3350(99)00339-9","article-title":"Capsular block syndrome: A case series","volume":"26","author":"Theng","year":"2000","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"10.1016\/j.ajo.2013.07.028_bib18","doi-asserted-by":"crossref","first-page":"1130","DOI":"10.1016\/j.jcrs.2003.08.014","article-title":"Capsular block syndrome caused by a reversed-optic intraocular lens","volume":"30","author":"Xiao","year":"2004","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"10.1016\/j.ajo.2013.07.028_bib19","doi-asserted-by":"crossref","first-page":"1775","DOI":"10.1016\/j.jcrs.2011.04.035","article-title":"Preoperative and postoperative size and movements of the lens capsular bag: ultrasound biomicroscopy analysis","volume":"37","author":"Modesti","year":"2011","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"10.1016\/j.ajo.2013.07.028_bib20","doi-asserted-by":"crossref","first-page":"986","DOI":"10.1016\/j.jcrs.2011.12.027","article-title":"Sulcus anatomy and diameter in pseudophakic eyes and correlation with biometric data: evaluation with a 50 MHz ultrasound biomicroscope","volume":"38","author":"Petermeier","year":"2012","journal-title":"J Cataract Refract Surg"},{"issue":"11","key":"10.1016\/j.ajo.2013.07.028_bib21","doi-asserted-by":"crossref","first-page":"1862","DOI":"10.1016\/j.jcrs.2010.05.017","article-title":"Comparative analysis of white-to-white and angle-to-angle distance measurements with partial coherence interferometry and optical coherence tomography","volume":"36","author":"Nemeth","year":"2010","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"10.1016\/j.ajo.2013.07.028_bib22","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1097\/ICL.0b013e3181f8bc3e","article-title":"\u2018Flow out technique\u2019 for safe and complete removal of ophthalmic viscosurgical devices after phacoemulsification cataract surgery","volume":"36","author":"Kreis","year":"2010","journal-title":"Eye Contact Lens"},{"issue":"5","key":"10.1016\/j.ajo.2013.07.028_bib23","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1111\/ceo.12024","article-title":"Assessment of adequate removal of ophthalmic viscoelastic device with irrigation\/aspiration by quantifying intraocular lens \u201cjudders\u201d","volume":"41","author":"Sim","year":"2013","journal-title":"Clin Experiment Ophthalmol"}],"container-title":["American Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002939413005333?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002939413005333?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T13:10:00Z","timestamp":1757596200000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002939413005333"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,12]]},"references-count":23,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2013,12]]}},"alternative-id":["S0002939413005333"],"URL":"https:\/\/doi.org\/10.1016\/j.ajo.2013.07.028","relation":{},"ISSN":["0002-9394"],"issn-type":[{"value":"0002-9394","type":"print"}],"subject":[],"published":{"date-parts":[[2013,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Detection and Influencing Factors of Capsular Bag Distention Syndrome after Cataract Surgery Using the Pentacam Scheimpflug System","name":"articletitle","label":"Article Title"},{"value":"American Journal of Ophthalmology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ajo.2013.07.028","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2013 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}