{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T07:21:49Z","timestamp":1791271309952,"version":"4.1.0"},"reference-count":38,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2015,5,1]],"date-time":"2015-05-01T00:00:00Z","timestamp":1430438400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2015,5,1]],"date-time":"2015-05-01T00:00:00Z","timestamp":1430438400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["ajo.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Journal of Ophthalmology"],"published-print":{"date-parts":[[2015,5]]},"DOI":"10.1016\/j.ajo.2015.02.003","type":"journal-article","created":{"date-parts":[[2015,2,11]],"date-time":"2015-02-11T02:16:24Z","timestamp":1423620984000},"page":"835-845.e3","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":14,"title":["Longitudinal Comparison of Outcomes After Sub-Bowman Keratomileusis and Laser in Situ Keratomileusis: Randomized, Double-Masked Study"],"prefix":"10.1016","volume":"159","author":[{"given":"Rachel Chung Yin","family":"Wong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tommy C.Y.","family":"Chan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kelvin K.L.","family":"Chong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vishal","family":"Jhanji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"3","key":"10.1016\/j.ajo.2015.02.003_bib1","doi-asserted-by":"crossref","first-page":"e5","DOI":"10.1016\/j.ophtha.2012.08.013","article-title":"Femtosecond lasers for LASIK flap creation: a report by the American Academy of Ophthalmology","volume":"120","author":"Farjo","year":"2013","journal-title":"Ophthalmology"},{"issue":"7","key":"10.1016\/j.ajo.2015.02.003_bib2","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1097\/ICO.0b013e3181967082","article-title":"Comparison of the changes in corneal biomechanical properties after photorefractive keratectomy and laser in\u00a0situ keratomileusis","volume":"28","author":"Kamiya","year":"2009","journal-title":"Cornea"},{"issue":"6","key":"10.1016\/j.ajo.2015.02.003_bib3","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1016\/j.ophtha.2009.01.001","article-title":"A prospective, contralateral eye study comparing thin-flap LASIK (sub-Bowman keratomileusis) with photorefractive keratectomy","volume":"116","author":"Slade","year":"2009","journal-title":"Ophthalmology"},{"issue":"11","key":"10.1016\/j.ajo.2015.02.003_bib4","doi-asserted-by":"crossref","first-page":"1897","DOI":"10.1016\/j.ophtha.2006.08.013","article-title":"Evidence for superior efficacy and safety of LASIK over photorefractive keratectomy for correction of myopia","volume":"113","author":"Shortt","year":"2006","journal-title":"Ophthalmology"},{"issue":"6","key":"10.1016\/j.ajo.2015.02.003_bib5","doi-asserted-by":"crossref","first-page":"790","DOI":"10.3928\/1081-597X-20041101-06","article-title":"Influence of flap thickness on results of laser in\u00a0situ keratomileusis for myopia","volume":"20","author":"Prandi","year":"2004","journal-title":"J Refract Surg"},{"issue":"12","key":"10.1016\/j.ajo.2015.02.003_bib6","doi-asserted-by":"crossref","first-page":"1290","DOI":"10.1038\/sj.eye.6701775","article-title":"The effect of flap thickness on the visual and refractive outcome of myopic laser in\u00a0situ keratomileusis","volume":"19","author":"Eleftheriadis","year":"2005","journal-title":"Eye (Lond)"},{"issue":"4","key":"10.1016\/j.ajo.2015.02.003_bib7","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1097\/ICU.0000000000000070","article-title":"Microkeratome versus femtosecond flaps: accuracy and complications","volume":"25","author":"Santhiago","year":"2014","journal-title":"Curr Opin Ophthalmol"},{"issue":"6","key":"10.1016\/j.ajo.2015.02.003_bib8","doi-asserted-by":"crossref","first-page":"392","DOI":"10.3928\/1081597X-20090728-02","article-title":"A prospective randomized comparison of four femtosecond LASIK flap thicknesses","volume":"26","author":"Prakash","year":"2010","journal-title":"J Refract Surg"},{"issue":"4","key":"10.1016\/j.ajo.2015.02.003_bib9","doi-asserted-by":"crossref","first-page":"251","DOI":"10.3928\/1081597X-20100624-01","article-title":"Prospective, contralateral comparison of 120-mum and 90-mum LASIK flaps using the IntraLase FS60 femtosecond laser","volume":"27","author":"Moshirfar","year":"2011","journal-title":"J Refract Surg"},{"issue":"7","key":"10.1016\/j.ajo.2015.02.003_bib10","doi-asserted-by":"crossref","first-page":"462","DOI":"10.3928\/1081597X-20130617-04","article-title":"Prospective contralateral eye study to compare 80- and 120-mum flap LASIK using the VisuMax femtosecond laser","volume":"29","author":"Lim","year":"2013","journal-title":"J Refract Surg"},{"issue":"1","key":"10.1016\/j.ajo.2015.02.003_bib11","first-page":"S97","article-title":"Complications of sub-Bowman's keratomileusis with a femtosecond laser in 3009 eyes","volume":"24","author":"Chang","year":"2008","journal-title":"J Refract Surg"},{"issue":"4","key":"10.1016\/j.ajo.2015.02.003_bib12","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1016\/j.ajo.2011.03.019","article-title":"Femtosecond sub-bowman keratomileusis: a prospective, long-term, intereye comparison of safety and outcomes of 90- versus 100-\u03bcm flaps","volume":"152","author":"Prakash","year":"2011","journal-title":"Am J Ophthalmol"},{"issue":"3","key":"10.1016\/j.ajo.2015.02.003_bib13","doi-asserted-by":"crossref","first-page":"222","DOI":"10.3928\/1081597X-20090930-02","article-title":"Persistent subepithelial haze in thin-flap LASIK","volume":"26","author":"Hafezi","year":"2010","journal-title":"J Refract Surg"},{"issue":"3","key":"10.1016\/j.ajo.2015.02.003_bib14","doi-asserted-by":"crossref","first-page":"937","DOI":"10.2307\/2533554","article-title":"Sample size calculations for studies with correlated observations","volume":"53","author":"Liu","year":"1997","journal-title":"Biometrics"},{"issue":"3","key":"10.1016\/j.ajo.2015.02.003_bib15","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1016\/j.jcrs.2007.10.026","article-title":"Incidence, possible risk factors, and potential effects of an opaque bubble layer created by a femtosecond laser","volume":"34","author":"Kaiserman","year":"2008","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"10.1016\/j.ajo.2015.02.003_bib16","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/S0161-6420(01)00966-6","article-title":"Laser in\u00a0situ keratomileusis for myopia and astigmatism: safety and efficacy: a report by the American Academy of Ophthalmology","volume":"109","author":"Sugar","year":"2002","journal-title":"Ophthalmology"},{"issue":"1","key":"10.1016\/j.ajo.2015.02.003_bib17","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.ajo.2007.09.010","article-title":"Ten-year follow-up of laser in\u00a0situ keratomileusis for myopia of up to -10 diopters","volume":"145","author":"Alio","year":"2008","journal-title":"Am J Ophthalmol"},{"issue":"6","key":"10.1016\/j.ajo.2015.02.003_bib18","doi-asserted-by":"crossref","first-page":"1236","DOI":"10.1016\/j.ophtha.2009.10.042","article-title":"A 10-year prospective audit of LASIK outcomes for myopia in 37,932 eyes at a single institution in Asia","volume":"117","author":"Yuen","year":"2010","journal-title":"Ophthalmology"},{"issue":"9","key":"10.1016\/j.ajo.2015.02.003_bib19","doi-asserted-by":"crossref","first-page":"620","DOI":"10.3928\/1081597X-20120815-06","article-title":"Evaluating the speed of visual recovery following thin-flap LASIK with a femtosecond laser","volume":"28","author":"Durrie","year":"2012","journal-title":"J Refract Surg"},{"issue":"2","key":"10.1016\/j.ajo.2015.02.003_bib20","doi-asserted-by":"crossref","first-page":"176","DOI":"10.3928\/1081-597X-20050301-14","article-title":"Theoretical elastic response of the cornea to refractive surgery: risk factors for keratectasia","volume":"21","author":"Guirao","year":"2005","journal-title":"J Refract Surg"},{"issue":"12","key":"10.1016\/j.ajo.2015.02.003_bib21","doi-asserted-by":"crossref","first-page":"2073","DOI":"10.1016\/j.jcrs.2008.08.019","article-title":"Thin-flap (sub-Bowman keratomileusis) versus thick-flap laser in\u00a0situ keratomileusis for moderate to high myopia: case-control analysis","volume":"34","author":"Azar","year":"2008","journal-title":"J Cataract Refract Surg"},{"issue":"11","key":"10.1016\/j.ajo.2015.02.003_bib22","doi-asserted-by":"crossref","first-page":"1484","DOI":"10.1001\/archopht.126.11.1484","article-title":"Comparison of the femtosecond laser and mechanical keratome for laser in\u00a0situ keratomileusis","volume":"126","author":"Chan","year":"2008","journal-title":"Arch Ophthalmol"},{"issue":"2","key":"10.1016\/j.ajo.2015.02.003_bib23","doi-asserted-by":"crossref","first-page":"99","DOI":"10.3928\/1081597X-20100121-05","article-title":"Safety and effectiveness of thin-flap LASIK using a femtosecond laser and microkeratome in the correction of high myopia in Chinese patients","volume":"26","author":"Li","year":"2010","journal-title":"J Refract Surg"},{"issue":"1","key":"10.1016\/j.ajo.2015.02.003_bib24","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1136\/bjophthalmol-2013-304023","article-title":"Comparative study of stromal bed of LASIK flaps created with femtosecond lasers (IntraLase FS150, WaveLight FS200) and mechanical microkeratome","volume":"98","author":"Kymionis","year":"2014","journal-title":"Br J Ophthalmol"},{"issue":"11","key":"10.1016\/j.ajo.2015.02.003_bib25","doi-asserted-by":"crossref","first-page":"1647","DOI":"10.1016\/j.jcrs.2013.04.044","article-title":"Visual outcomes comparison of 2 femtosecond laser platforms for laser in\u00a0situ keratomileusis","volume":"39","author":"Ang","year":"2013","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"10.1016\/j.ajo.2015.02.003_bib26","doi-asserted-by":"crossref","first-page":"195","DOI":"10.3928\/1081597X-20120127-02","article-title":"Change in epithelial thickness profile 24 hours and longitudinally for 1 year after myopic LASIK: three-dimensional display with Artemis very high-frequency digital ultrasound","volume":"28","author":"Reinstein","year":"2012","journal-title":"J Refract Surg"},{"issue":"8","key":"10.1016\/j.ajo.2015.02.003_bib27","doi-asserted-by":"crossref","first-page":"1447","DOI":"10.1016\/S0161-6420(02)01106-5","article-title":"Effect of myopic laser in\u00a0situ keratomileusis on epithelial and stromal thickness: a confocal microscopy study","volume":"109","author":"Erie","year":"2002","journal-title":"Ophthalmology"},{"issue":"2","key":"10.1016\/j.ajo.2015.02.003_bib28","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.ajo.2014.04.012","article-title":"Spectral-domain optical coherence tomography epithelial and flap thickness mapping in femtosecond laser-assisted in\u00a0situ keratomileusis","volume":"158","author":"Maia Rocha","year":"2014","journal-title":"Am J Ophthalmol"},{"issue":"11","key":"10.1016\/j.ajo.2015.02.003_bib29","doi-asserted-by":"crossref","first-page":"979","DOI":"10.3928\/1081597X-20091016-02","article-title":"Complications of LASIK flaps made by the IntraLase 15- and 30-kHz femtosecond lasers","volume":"25","author":"Haft","year":"2009","journal-title":"J Refract Surg"},{"issue":"3","key":"10.1016\/j.ajo.2015.02.003_bib30","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1016\/j.jcrs.2013.08.055","article-title":"Opaque bubble layer: incidence, risk factors, and clinical relevance","volume":"40","author":"Liu","year":"2014","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"10.1016\/j.ajo.2015.02.003_bib31","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1016\/j.jcrs.2012.05.021","article-title":"Optical parameters to improve the interface quality of the flap bed in femtosecond laser-assisted laser in\u00a0situ keratomileusis","volume":"38","author":"Serrao","year":"2012","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"10.1016\/j.ajo.2015.02.003_bib32","doi-asserted-by":"crossref","first-page":"2396","DOI":"10.1016\/j.ophtha.2013.05.010","article-title":"One-year outcomes from a prospective, randomized, eye-to-eye comparison of wavefront-guided and wavefront-optimized LASIK in myopes","volume":"120","author":"Sales","year":"2013","journal-title":"Ophthalmology"},{"issue":"12","key":"10.1016\/j.ajo.2015.02.003_bib33","doi-asserted-by":"crossref","first-page":"827","DOI":"10.3928\/1081597X-20141113-04","article-title":"A comparision of LASIK flap thickness and morphology between the IntraLase 60-kHz and 150-kHz femtosecond lasers","volume":"30","author":"Yu","year":"2014","journal-title":"J Refract Surg"},{"issue":"6","key":"10.1016\/j.ajo.2015.02.003_bib34","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1016\/j.jcrs.2010.03.025","article-title":"Femtosecond laser in laser in\u00a0situ keratomileusis","volume":"36","author":"Salomao","year":"2010","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"10.1016\/j.ajo.2015.02.003_bib35","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1097\/ICO.0b013e318033e7cc","article-title":"Comparative study of stromal bed quality by using mechanical, IntraLase femtosecond laser 15- and 30-kHz microkeratomes","volume":"26","author":"Sarayba","year":"2007","journal-title":"Cornea"},{"issue":"12","key":"10.1016\/j.ajo.2015.02.003_bib36","doi-asserted-by":"crossref","first-page":"2311","DOI":"10.1016\/j.ophtha.2014.07.015","article-title":"Corneal sensation and dry eye symptoms after conventional versus inverted side-cut femtosecond LASIK","volume":"121","author":"Kung","year":"2014","journal-title":"Ophthalmology"},{"issue":"6","key":"10.1016\/j.ajo.2015.02.003_bib37","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1111\/aos.12396","article-title":"Randomized, contralateral eye study to evaluate the effect of standard and inverted side-cut angle on corneal biomechanical properties during femtosecond laser-assisted in\u00a0situ keratomileusis","volume":"92","author":"Yip","year":"2014","journal-title":"Acta Ophthalmol"},{"issue":"5","key":"10.1016\/j.ajo.2015.02.003_bib38","doi-asserted-by":"crossref","first-page":"320","DOI":"10.3928\/1081597X-20130415-03","article-title":"Comparison of corneal flap morphology using AS-OCT in LASIK with the WaveLight FS200 femtosecond laser versus a mechanical microkeratome","volume":"29","author":"Zhang","year":"2013","journal-title":"J Refract Surg"}],"container-title":["American Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002939415000732?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002939415000732?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T13:13:29Z","timestamp":1757596409000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002939415000732"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,5]]},"references-count":38,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2015,5]]}},"alternative-id":["S0002939415000732"],"URL":"https:\/\/doi.org\/10.1016\/j.ajo.2015.02.003","relation":{},"ISSN":["0002-9394"],"issn-type":[{"value":"0002-9394","type":"print"}],"subject":[],"published":{"date-parts":[[2015,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Longitudinal Comparison of Outcomes After Sub-Bowman Keratomileusis and Laser in Situ Keratomileusis: Randomized, Double-Masked Study","name":"articletitle","label":"Article Title"},{"value":"American Journal of Ophthalmology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ajo.2015.02.003","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}