{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,19]],"date-time":"2025-12-19T21:47:03Z","timestamp":1766180823371,"version":"3.44.0"},"reference-count":29,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,1,1]],"date-time":"2016-01-01T00:00:00Z","timestamp":1451606400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["ajo.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Journal of Ophthalmology"],"published-print":{"date-parts":[[2016,1]]},"DOI":"10.1016\/j.ajo.2015.09.040","type":"journal-article","created":{"date-parts":[[2015,10,16]],"date-time":"2015-10-16T14:10:39Z","timestamp":1445004639000},"page":"142-149.e2","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":22,"special_numbering":"C","title":["Modified Haigis Formula Effective Lens Position Equation for Ciliary Sulcus\u2013Implanted Intraocular Lenses"],"prefix":"10.1016","volume":"161","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9475-4409","authenticated-orcid":false,"given":"Youngsub","family":"Eom","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jong Suk","family":"Song","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hyo Myung","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.ajo.2015.09.040_bib1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0886-3350(02)02011-4","article-title":"Intraocular lens power accuracy: how are we doing?","volume":"29","author":"Mamalis","year":"2003","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"10.1016\/j.ajo.2015.09.040_bib2","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1111\/j.1755-3768.2007.00879.x","article-title":"Calculation of intraocular lens power: a review","volume":"85","author":"Olsen","year":"2007","journal-title":"Acta Ophthalmol Scand"},{"issue":"1","key":"10.1016\/j.ajo.2015.09.040_bib3","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1111\/j.1600-0420.2006.00774.x","article-title":"Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster","volume":"85","author":"Olsen","year":"2007","journal-title":"Acta Ophthalmol Scand"},{"issue":"12","key":"10.1016\/j.ajo.2015.09.040_bib4","doi-asserted-by":"crossref","first-page":"1336","DOI":"10.1136\/bjo.83.12.1336","article-title":"National cataract surgery survey 1997-8: a report of the results of the clinical outcomes","volume":"83","author":"Desai","year":"1999","journal-title":"Br J Ophthalmol"},{"issue":"6","key":"10.1016\/j.ajo.2015.09.040_bib5","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1136\/bjo.2006.104216","article-title":"Raising the benchmark for the 21st century\u2013the 1000 cataract operations audit and survey: outcomes, consultant-supervised training and sourcing NHS choice","volume":"91","author":"Zaidi","year":"2007","journal-title":"Br J Ophthalmol"},{"issue":"4","key":"10.1016\/j.ajo.2015.09.040_bib6","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1016\/S0161-6420(02)02000-6","article-title":"Intraocular lens implantation in the absence of capsular support: a report by the American Academy of Ophthalmology","volume":"110","author":"Wagoner","year":"2003","journal-title":"Ophthalmology"},{"issue":"10","key":"10.1016\/j.ajo.2015.09.040_bib7","doi-asserted-by":"crossref","first-page":"1913","DOI":"10.1016\/S0886-3350(03)00250-5","article-title":"Adjusting intraocular lens power for sulcus fixation","volume":"29","author":"Suto","year":"2003","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"10.1016\/j.ajo.2015.09.040_bib8","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.ophtha.2011.07.050","article-title":"Improved refractive outcome for ciliary sulcus-implanted intraocular lenses","volume":"119","author":"Dubey","year":"2012","journal-title":"Ophthalmology"},{"issue":"11","key":"10.1016\/j.ajo.2015.09.040_bib9","first-page":"2144","article-title":"[The difference in post-operative refractive error between in-the-bag and sulcus intraocular lens implantation.]","volume":"43","author":"Lee","year":"2002","journal-title":"J Korean Ophthalmol Soc"},{"issue":"3","key":"10.1016\/j.ajo.2015.09.040_bib10","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/j.ophtha.2012.09.008","article-title":"Use of corneal power-specific constants to improve the accuracy of the SRK\/T formula","volume":"120","author":"Eom","year":"2013","journal-title":"Ophthalmology"},{"issue":"4","key":"10.1016\/j.ajo.2015.09.040_bib11","doi-asserted-by":"crossref","first-page":"818","DOI":"10.1016\/j.ajo.2013.12.017","article-title":"Comparison of Hoffer Q and Haigis formulae for intraocular lens power calculation according to the anterior chamber depth in short eyes","volume":"157","author":"Eom","year":"2014","journal-title":"Am J Ophthalmol"},{"issue":"3","key":"10.1016\/j.ajo.2015.09.040_bib12","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1016\/j.ophtha.2010.07.008","article-title":"Accuracy of intraocular lens calculations using the IOLMaster in eyes with long axial length and a comparison of various formulas","volume":"118","author":"Bang","year":"2011","journal-title":"Ophthalmology"},{"key":"10.1016\/j.ajo.2015.09.040_bib13","series-title":"Intraocular Lens Power Calculations","first-page":"41","article-title":"The Haigis formula","author":"Haigis","year":"2004"},{"issue":"10","key":"10.1016\/j.ajo.2015.09.040_bib14","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1136\/bjo.57.10.735","article-title":"Calculation of the power of an iris clip lens for distant vision","volume":"57","author":"Colenbrander","year":"1973","journal-title":"Br J Ophthalmol"},{"issue":"8","key":"10.1016\/j.ajo.2015.09.040_bib15","first-page":"625","article-title":"Calculation of the optical power of intraocular lenses","volume":"14","author":"Fyodorov","year":"1975","journal-title":"Invest Ophthalmol"},{"issue":"8","key":"10.1016\/j.ajo.2015.09.040_bib16","doi-asserted-by":"crossref","first-page":"1650","DOI":"10.1016\/j.jcrs.2014.12.053","article-title":"Comparison of SRK\/T and Haigis formulas for predicting corneal astigmatism correction by toric intraocular lens","volume":"41","author":"Eom","year":"2015","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"10.1016\/j.ajo.2015.09.040_bib17","doi-asserted-by":"crossref","first-page":"1685","DOI":"10.1016\/j.ophtha.2006.12.018","article-title":"Direct measurement of the ciliary sulcus diameter by 35-megahertz ultrasound biomicroscopy","volume":"114","author":"Oh","year":"2007","journal-title":"Ophthalmology"},{"issue":"4","key":"10.1016\/j.ajo.2015.09.040_bib18","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1016\/j.jcrs.2007.11.034","article-title":"Correlation between ciliary sulcus diameter measured by 35 MHz ultrasound biomicroscopy and other ocular measurements","volume":"34","author":"Kim","year":"2008","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"10.1016\/j.ajo.2015.09.040_bib19","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1016\/j.jcrs.2012.12.002","article-title":"Multifocal intraocular lenses in cataract surgery: literature review of benefits and side effects","volume":"39","author":"de Vries","year":"2013","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"10.1016\/j.ajo.2015.09.040_bib20","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1016\/j.jcrs.2009.02.018","article-title":"Visual outcome comparison of unilateral versus bilateral implantation of apodized diffractive multifocal intraocular lenses after cataract extraction: prospective 6-month study","volume":"35","author":"Cionni","year":"2009","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"10.1016\/j.ajo.2015.09.040_bib21","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/S0886-3350(03)00654-0","article-title":"Outcomes of sulcus implantation of Array multifocal intraocular lenses in second-eye cataract surgery complicated by vitreous loss","volume":"30","author":"Aralikatti","year":"2004","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"10.1016\/j.ajo.2015.09.040_bib22","doi-asserted-by":"crossref","first-page":"1960","DOI":"10.1016\/j.jcrs.2005.03.062","article-title":"Effect of postoperative refractive error on visual acuity and patient satisfaction after implantation of the Array multifocal intraocular lens","volume":"31","author":"Lee","year":"2005","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"10.1016\/j.ajo.2015.09.040_bib23","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1016\/S0886-3350(02)01637-1","article-title":"Reasons for secondary surgical intervention after phacoemulsification with posterior chamber lens implantation","volume":"29","author":"Raman","year":"2003","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"10.1016\/j.ajo.2015.09.040_bib24","doi-asserted-by":"crossref","first-page":"1461","DOI":"10.1016\/j.jcrs.2003.11.056","article-title":"Secondary procedures after presbyopic lens exchange","volume":"30","author":"Leccisotti","year":"2004","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"10.1016\/j.ajo.2015.09.040_bib25","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1097\/ICU.0000000000000111","article-title":"Enhancements after cataract surgery","volume":"26","author":"Alio","year":"2015","journal-title":"Curr Opin Ophthalmol"},{"issue":"8","key":"10.1016\/j.ajo.2015.09.040_bib26","doi-asserted-by":"crossref","first-page":"1445","DOI":"10.1016\/j.jcrs.2009.04.027","article-title":"Complications of sulcus placement of single-piece acrylic intraocular lenses: recommendations for backup IOL implantation following posterior capsule rupture","volume":"35","author":"Chang","year":"2009","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"10.1016\/j.ajo.2015.09.040_bib27","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/S0886-3350(13)80249-0","article-title":"Accuracy of the newer generation intraocular lens power calculation formulas in long and short eyes","volume":"17","author":"Olsen","year":"1991","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"10.1016\/j.ajo.2015.09.040_bib28","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1136\/bjo.61.5.360","article-title":"Astigmatism in cataract surgery","volume":"61","author":"Luntz","year":"1977","journal-title":"Br J Ophthalmol"},{"issue":"2","key":"10.1016\/j.ajo.2015.09.040_bib29","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.jcrs.2004.06.042","article-title":"Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule","volume":"31","author":"Hayashi","year":"2005","journal-title":"J Cataract Refract Surg"}],"container-title":["American Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002939415006108?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002939415006108?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T13:15:17Z","timestamp":1757596517000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002939415006108"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1]]},"references-count":29,"alternative-id":["S0002939415006108"],"URL":"https:\/\/doi.org\/10.1016\/j.ajo.2015.09.040","relation":{},"ISSN":["0002-9394"],"issn-type":[{"type":"print","value":"0002-9394"}],"subject":[],"published":{"date-parts":[[2016,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Modified Haigis Formula Effective Lens Position Equation for Ciliary Sulcus\u2013Implanted Intraocular Lenses","name":"articletitle","label":"Article Title"},{"value":"American Journal of Ophthalmology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ajo.2015.09.040","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2016 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}