{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T10:39:34Z","timestamp":1788172774945,"version":"build-2803163510"},"reference-count":33,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2017,6,1]],"date-time":"2017-06-01T00:00:00Z","timestamp":1496275200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,6,1]],"date-time":"2017-06-01T00:00:00Z","timestamp":1496275200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["ajo.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Journal of Ophthalmology"],"published-print":{"date-parts":[[2017,6]]},"DOI":"10.1016\/j.ajo.2017.02.027","type":"journal-article","created":{"date-parts":[[2017,3,2]],"date-time":"2017-03-02T16:19:27Z","timestamp":1488471567000},"page":"58-64","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":116,"special_numbering":"C","title":["Comparison of Axial Length, Corneal Curvature, and Anterior Chamber Depth Measurements of 2 Recently Introduced Devices to a Known Biometer"],"prefix":"10.1016","volume":"178","author":[{"given":"Mehdi","family":"Shajari","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carla","family":"Cremonese","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kerstin","family":"Petermann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pankaj","family":"Singh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"M\u00fcller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Kohnen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.ajo.2017.02.027_bib1","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.jcrs.2010.07.032","article-title":"Formula choice: Hoffer Q, Holladay 1, or SRK\/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry","volume":"37","author":"Aristodemou","year":"2011","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"10.1016\/j.ajo.2017.02.027_bib2","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1016\/S0886-3350(00)00376-X","article-title":"Clinical results using the Holladay 2 intraocular lens power formula","volume":"26","author":"Hoffer","year":"2000","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"10.1016\/j.ajo.2017.02.027_bib3","doi-asserted-by":"crossref","first-page":"1697","DOI":"10.1097\/OPX.0b013e31827717ae","article-title":"Intraocular lens power measured by partial coherence interferometry","volume":"89","author":"Hsieh","year":"2012","journal-title":"Optom Vis Sci"},{"issue":"10","key":"10.1016\/j.ajo.2017.02.027_bib4","doi-asserted-by":"crossref","first-page":"1344","DOI":"10.1038\/eye.2012.163","article-title":"Accuracy and reliability of IOL master and A-scan immersion biometry in\u00a0silicone oil-filled eyes","volume":"26","author":"Kunavisarut","year":"2012","journal-title":"Eye"},{"issue":"3","key":"10.1016\/j.ajo.2017.02.027_bib5","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1111\/j.1475-1313.2012.00903.x","article-title":"Accuracy of intraocular lens power calculation using partial coherence interferometry in patients with high myopia","volume":"32","author":"Roessler","year":"2012","journal-title":"Ophthalmic Physiol Opt"},{"issue":"1","key":"10.1016\/j.ajo.2017.02.027_bib6","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1111\/j.1600-0420.2006.00774.x","article-title":"Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster","volume":"85","author":"Olsen","year":"2006","journal-title":"Acta Ophthalmol Scand"},{"issue":"12","key":"10.1016\/j.ajo.2017.02.027_bib7","doi-asserted-by":"crossref","first-page":"2080","DOI":"10.1016\/j.jcrs.2012.08.036","article-title":"Contribution of posterior corneal astigmatism to total corneal astigmatism","volume":"38","author":"Koch","year":"2012","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"10.1016\/j.ajo.2017.02.027_bib8","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1111\/aos.12965","article-title":"Posterior corneal astigmatism in refractive lens exchange surgery","volume":"94","author":"Rydstr\u00f6m","year":"2016","journal-title":"Acta Ophthalmol (Copenh)"},{"issue":"3","key":"10.1016\/j.ajo.2017.02.027_bib9","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1016\/j.ajo.2013.04.035","article-title":"Scheimpflug corneal power measurements for intraocular lens power calculation in cataract surgery","volume":"156","author":"Saad","year":"2013","journal-title":"Am J Ophthalmol"},{"issue":"1","key":"10.1016\/j.ajo.2017.02.027_bib10","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1167\/iovs.14-15659","article-title":"Anterior surface-based keratometry compared with Scheimpflug tomography-based total corneal astigmatism","volume":"56","author":"Tonn","year":"2015","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"9","key":"10.1016\/j.ajo.2017.02.027_bib11","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1136\/bjophthalmol-2015-307779","article-title":"Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500","volume":"100","author":"Akman","year":"2016","journal-title":"Br J Ophthalmol"},{"issue":"4","key":"10.1016\/j.ajo.2017.02.027_bib12","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1016\/j.jcrs.2016.01.038","article-title":"Biometry with a new swept-source optical coherence tomography biometer: Repeatability and agreement with an optical low-coherence reflectometry device","volume":"42","author":"Kurian","year":"2016","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"10.1016\/j.ajo.2017.02.027_bib13","doi-asserted-by":"crossref","first-page":"2224","DOI":"10.1016\/j.jcrs.2015.03.019","article-title":"Clinical comparison of a new swept-source optical coherence tomography\u2013based optical biometer and a time-domain optical coherence tomography\u2013based optical biometer","volume":"41","author":"Srivannaboon","year":"2015","journal-title":"J Cataract Refract Surg"},{"issue":"8476","key":"10.1016\/j.ajo.2017.02.027_bib14","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"issue":"1","key":"10.1016\/j.ajo.2017.02.027_bib15","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/S0886-3350(98)80075-8","article-title":"Evaluating and reporting astigmatism for individual and aggregate data","volume":"24","author":"Holladay","year":"1998","journal-title":"J Cataract Refract Surg"},{"issue":"7047","key":"10.1016\/j.ajo.2017.02.027_bib16","doi-asserted-by":"crossref","first-page":"1654","DOI":"10.1136\/bmj.312.7047.1654","article-title":"Measurement error","volume":"312","author":"Bland","year":"1996","journal-title":"BMJ"},{"issue":"6","key":"10.1016\/j.ajo.2017.02.027_bib17","doi-asserted-by":"crossref","first-page":"1111","DOI":"10.1016\/j.ajo.2014.08.014","article-title":"Overview of the repeatability, reproducibility, and agreement of the biometry values provided by various ophthalmic devices","volume":"158","author":"Rozema","year":"2014","journal-title":"Am J Ophthalmol"},{"issue":"2","key":"10.1016\/j.ajo.2017.02.027_bib18","doi-asserted-by":"crossref","first-page":"144","DOI":"10.3928\/15428877-20110210-03","article-title":"Comparison of anterior chamber depth measurements conducted with Pentacam HR\u00ae and IOLMaster\u00ae","volume":"42","author":"N\u00e9meth","year":"2011","journal-title":"Ophthalmic Surg Lasers Imaging"},{"issue":"1","key":"10.1016\/j.ajo.2017.02.027_bib19","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.jcrs.2015.07.039","article-title":"Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry","volume":"42","author":"Kunert","year":"2016","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"10.1016\/j.ajo.2017.02.027_bib20","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1016\/j.jcrs.2014.04.038","article-title":"Anterior chamber depth measurements using Scheimpflug imaging and optical coherence tomography: Repeatability, reproducibility, and agreement","volume":"41","author":"Wang","year":"2015","journal-title":"J Cataract Refract Surg"},{"issue":"11","key":"10.1016\/j.ajo.2017.02.027_bib21","doi-asserted-by":"crossref","first-page":"2087","DOI":"10.1016\/j.ophtha.2009.04.019","article-title":"Comparison and evaluation of ocular biometry using a new noncontact optical low-coherence reflectometer","volume":"116","author":"Rohrer","year":"2009","journal-title":"Ophthalmology"},{"issue":"9","key":"10.1016\/j.ajo.2017.02.027_bib22","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1136\/bjophthalmol-2014-305150","article-title":"Evaluation of a new optical biometry device for measurements of ocular components and its comparison with IOLMaster","volume":"98","author":"Huang","year":"2014","journal-title":"Br J Ophthalmol"},{"issue":"6","key":"10.1016\/j.ajo.2017.02.027_bib23","first-page":"717","article-title":"Agreement analysis of LENSTAR with other techniques of biometry","volume":"25","author":"Jasvinder","year":"2011","journal-title":"Eye Lond Engl"},{"issue":"10","key":"10.1016\/j.ajo.2017.02.027_bib24","doi-asserted-by":"crossref","first-page":"1764","DOI":"10.1016\/j.jcrs.2012.05.036","article-title":"Comparability and repeatability of corneal astigmatism measurements using different measurement technologies","volume":"38","author":"Visser","year":"2012","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"10.1016\/j.ajo.2017.02.027_bib25","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1016\/j.jcrs.2011.11.037","article-title":"Accuracy of corneal power measurements by a new Scheimpflug camera combined with Placido-disk corneal topography for intraocular lens power calculation in unoperated eyes","volume":"38","author":"Savini","year":"2012","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"10.1016\/j.ajo.2017.02.027_bib26","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1016\/j.jcrs.2008.10.041","article-title":"Scheimpflug photography keratometry readings for routine intraocular lens power calculation","volume":"35","author":"Shammas","year":"2009","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"10.1016\/j.ajo.2017.02.027_bib27","doi-asserted-by":"crossref","first-page":"368","DOI":"10.3928\/1081-597X-20070401-09","article-title":"Corneal radii and anterior chamber depth measurements using the IOLmaster versus the Pentacam","volume":"23","author":"Reuland","year":"2007","journal-title":"J Refract Surg"},{"issue":"9","key":"10.1016\/j.ajo.2017.02.027_bib28","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1111\/ceo.12124","article-title":"Comparison of the Pentacam equivalent keratometry reading and IOL Master keratometry measurement in intraocular lens power calculations","volume":"41","author":"Karunaratne","year":"2013","journal-title":"Clin Exp Ophthalmol"},{"issue":"4","key":"10.1016\/j.ajo.2017.02.027_bib29","doi-asserted-by":"crossref","first-page":"44006","DOI":"10.1117\/1.2337290","article-title":"Fourier-domain biophotoacoustic subsurface depth selective amplitude and phase imaging of turbid phantoms and biological tissue","volume":"11","author":"Telenkov","year":"2006","journal-title":"J Biomed Opt"},{"issue":"11","key":"10.1016\/j.ajo.2017.02.027_bib30","doi-asserted-by":"crossref","first-page":"2184","DOI":"10.1016\/j.ophtha.2013.04.007","article-title":"Reproducibility of a long-range swept-source optical coherence tomography ocular biometry system and comparison with clinical biometers","volume":"120","author":"Grulkowski","year":"2013","journal-title":"Ophthalmology"},{"issue":"6","key":"10.1016\/j.ajo.2017.02.027_bib31","doi-asserted-by":"crossref","first-page":"552","DOI":"10.5301\/ejo.5000630","article-title":"Foveal pit morphology evaluation during optical biometry measurements using a full-eye-length swept-source OCT scan biometer prototype","volume":"25","author":"Bertelmann","year":"2015","journal-title":"Eur J Ophthalmol"},{"issue":"4","key":"10.1016\/j.ajo.2017.02.027_bib32","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1016\/j.jcrs.2016.02.029","article-title":"Macular disease detection with a swept-source optical coherence tomography-based biometry device in patients scheduled for cataract surgery","volume":"42","author":"Hirnschall","year":"2016","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"10.1016\/j.ajo.2017.02.027_bib33","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1016\/j.jcrs.2016.07.013","article-title":"Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry","volume":"42","author":"Hoffer","year":"2016","journal-title":"J Cataract Refract Surg"}],"container-title":["American Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002939417300946?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002939417300946?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T13:33:53Z","timestamp":1757597633000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002939417300946"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6]]},"references-count":33,"alternative-id":["S0002939417300946"],"URL":"https:\/\/doi.org\/10.1016\/j.ajo.2017.02.027","relation":{},"ISSN":["0002-9394"],"issn-type":[{"value":"0002-9394","type":"print"}],"subject":[],"published":{"date-parts":[[2017,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of Axial Length, Corneal Curvature, and Anterior Chamber Depth Measurements of 2 Recently Introduced Devices to a Known Biometer","name":"articletitle","label":"Article Title"},{"value":"American Journal of Ophthalmology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ajo.2017.02.027","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}