{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,10]],"date-time":"2025-12-10T20:35:59Z","timestamp":1765398959837,"version":"3.46.0"},"reference-count":7,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T00:00:00Z","timestamp":1764547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,8,22]],"date-time":"2025-08-22T00:00:00Z","timestamp":1755820800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Journal of Ophthalmology Case Reports"],"published-print":{"date-parts":[[2025,12]]},"DOI":"10.1016\/j.ajoc.2025.102412","type":"journal-article","created":{"date-parts":[[2025,8,23]],"date-time":"2025-08-23T15:16:32Z","timestamp":1755962192000},"page":"102412","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Suture stent insertion into an over draining tube shunt lumen via single paracentesis"],"prefix":"10.1016","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3419-761X","authenticated-orcid":false,"given":"Sukriti","family":"Mohan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4539-3771","authenticated-orcid":false,"given":"Jessie","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0155-7738","authenticated-orcid":false,"given":"Jonathan","family":"Eisengart","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0062-7386","authenticated-orcid":false,"given":"Mary","family":"Qiu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"10","key":"10.1016\/j.ajoc.2025.102412_bib1","doi-asserted-by":"crossref","first-page":"2093","DOI":"10.1016\/j.ophtha.2016.06.035","article-title":"The ahmed versus baerveldt study: five-year treatment outcomes","volume":"123","author":"Christakis","year":"2016","journal-title":"Ophthalmology"},{"issue":"1","key":"10.1016\/j.ajoc.2025.102412_bib2","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.ogla.2023.07.005","article-title":"Baerveldt-350 with 3-0 prolene ripcord to minimize hypotony-associated complications after spontaneous ligature dissolution","volume":"7","author":"Wang","year":"2024","journal-title":"Ophthalmol Glaucoma"},{"issue":"1","key":"10.1016\/j.ajoc.2025.102412_bib3","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.ogla.2023.07.006","article-title":"Techniques and preferences for nonvalved aqueous shunts: a survey of American glaucoma society members","volume":"7","author":"Zhang","year":"2024","journal-title":"Ophthalmol Glaucoma"},{"key":"10.1016\/j.ajoc.2025.102412_bib4","article-title":"Baerveldt-350 with adjunctive goniotomy: pilot results","volume":"32","author":"Kanter","year":"2023","journal-title":"Am J Ophthalmol Case Rep"},{"issue":"9","key":"10.1016\/j.ajoc.2025.102412_bib5","doi-asserted-by":"crossref","first-page":"860","DOI":"10.1111\/ceo.12784","article-title":"Secondary stenting of glaucoma drainage implant: a novel technique for treatment of late hypotony","volume":"44","author":"Kuruvilla","year":"2016","journal-title":"Clin Exp Ophthalmol"},{"issue":"4","key":"10.1016\/j.ajoc.2025.102412_bib6","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.ogla.2018.12.003","article-title":"Management of tube-related hypotony using Ab interno placement of multifilament nylon suture to reduce flow","volume":"2","author":"Iyer","year":"2019","journal-title":"Ophthalmol Glaucoma"},{"key":"10.1016\/j.ajoc.2025.102412_bib10","article-title":"Three techniques for guidewire-assisted sulcus glaucoma tube shunt placement","volume":"34","author":"Shah","year":"2024","journal-title":"Am J Ophthalmol Case Rep"}],"container-title":["American Journal of Ophthalmology Case Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2451993625001653?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2451993625001653?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,12,10]],"date-time":"2025-12-10T20:31:01Z","timestamp":1765398661000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2451993625001653"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12]]},"references-count":7,"alternative-id":["S2451993625001653"],"URL":"https:\/\/doi.org\/10.1016\/j.ajoc.2025.102412","relation":{},"ISSN":["2451-9936"],"issn-type":[{"type":"print","value":"2451-9936"}],"subject":[],"published":{"date-parts":[[2025,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Suture stent insertion into an over draining tube shunt lumen via single paracentesis","name":"articletitle","label":"Article Title"},{"value":"American Journal of Ophthalmology Case Reports","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ajoc.2025.102412","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 Published by Elsevier Inc.","name":"copyright","label":"Copyright"}],"article-number":"102412"}}