{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T02:48:06Z","timestamp":1760237286863,"version":"build-2065373602"},"reference-count":29,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2022,11,1]],"date-time":"2022-11-01T00:00:00Z","timestamp":1667260800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,11,1]],"date-time":"2022-11-01T00:00:00Z","timestamp":1667260800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["ajodo.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Journal of Orthodontics and Dentofacial Orthopedics"],"published-print":{"date-parts":[[2022,11]]},"DOI":"10.1016\/j.ajodo.2021.06.024","type":"journal-article","created":{"date-parts":[[2022,8,11]],"date-time":"2022-08-11T08:08:59Z","timestamp":1660205339000},"page":"689-694","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Evaluation of reused orthodontic mini-implants on stability: An in-vivo study"],"prefix":"10.1016","volume":"162","author":[{"given":"Serkan","family":"\u00d6zkan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S\u00fcleyman Kutalm\u0131\u015f","family":"B\u00fcy\u00fck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F\u0131rat","family":"G\u00f6k","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasin Atakan","family":"Benkli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.ajodo.2021.06.024_bib1","doi-asserted-by":"crossref","DOI":"10.1016\/j.ajodo.2008.03.012","article-title":"Torsional properties and microstructures of miniscrew implants","volume":"134","author":"Iijima","year":"2008","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1016\/j.ajodo.2021.06.024_bib2","doi-asserted-by":"crossref","first-page":"e6","DOI":"10.1016\/j.tripleo.2006.11.022","article-title":"The use of miniscrew implants for temporary skeletal anchorage in orthodontics: A comprehensive review","volume":"103","author":"Papadopoulos","year":"2007","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"10.1016\/j.ajodo.2021.06.024_bib3","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1016\/S0889-5406(03)00047-7","article-title":"Intrusion of posterior teeth using mini-screw implants","volume":"123","author":"Park","year":"2003","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1016\/j.ajodo.2021.06.024_bib4","doi-asserted-by":"crossref","first-page":"878","DOI":"10.2319\/092613-703.1","article-title":"Biomechanical characteristics and reinsertion guidelines for retrieved orthodontic miniscrews","volume":"84","author":"Chung","year":"2014","journal-title":"Angle Orthod"},{"key":"10.1016\/j.ajodo.2021.06.024_bib5","doi-asserted-by":"crossref","DOI":"10.1016\/j.ajodo.2008.06.019","article-title":"Characterization of retrieved orthodontic miniscrew implants","volume":"135","author":"Eliades","year":"2009","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1016\/j.ajodo.2021.06.024_bib6","doi-asserted-by":"crossref","first-page":"167","DOI":"10.4041\/kjod.2010.40.3.167","article-title":"The validation of Periotest values for the evaluation of orthodontic mini-implants\u2019 stability","volume":"40","author":"Cha","year":"2010","journal-title":"Korean J Orthod"},{"key":"10.1016\/j.ajodo.2021.06.024_bib7","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1016\/j.ajodo.2007.05.025","article-title":"Soft bone primary stability of 3 different miniscrews for orthodontic anchorage: a resonance frequency investigation","volume":"135","author":"Veltri","year":"2009","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1016\/j.ajodo.2021.06.024_bib8","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1016\/j.ajodo.2010.01.018","article-title":"Factors affecting the long-term stability of orthodontic mini-implants","volume":"137","author":"Motoyoshi","year":"2010","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1016\/j.ajodo.2021.06.024_bib9","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/j.ajodo.2003.12.023","article-title":"Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs","volume":"127","author":"Huja","year":"2005","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"12","key":"10.1016\/j.ajodo.2021.06.024_bib10","article-title":"Der Periotest--Parodontalstatus [The Periotest--periodontal status]","volume":"76","author":"Schulte","year":"1986","journal-title":"Zahnarztl Mitt"},{"key":"10.1016\/j.ajodo.2021.06.024_bib11","first-page":"447","article-title":"A processing method for orthodontic mini-screws reuse","volume":"9","author":"Noorollahian","year":"2012","journal-title":"Dent Res J (Isfahan)"},{"key":"10.1016\/j.ajodo.2021.06.024_bib12","first-page":"513","article-title":"The use of temporary skeletal anchorage devices amongst South African orthodontists","volume":"71","author":"Mothobela","year":"2016","journal-title":"S Afr Dent J"},{"key":"10.1016\/j.ajodo.2021.06.024_bib13","doi-asserted-by":"crossref","first-page":"1623","DOI":"10.1016\/j.hrthm.2010.04.027","article-title":"Reuse of pacemakers and defibrillators in developing countries: logistical, legal, and ethical barriers and solutions","volume":"7","author":"Kirkpatrick","year":"2010","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.ajodo.2021.06.024_bib14","doi-asserted-by":"crossref","first-page":"218","DOI":"10.4103\/0972-0707.157256","article-title":"The effect of multiple autoclave cycles on the surface of rotary nickel-titanium endodontic files: an in\u00a0vitro atomic force microscopy investigation","volume":"18","author":"Nair","year":"2015","journal-title":"J Conserv Dent"},{"key":"10.1016\/j.ajodo.2021.06.024_bib15","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1034\/j.1600-0501.2000.011003183.x","article-title":"Re-use of implant coverscrews changes their surface properties but not clinical outcome","volume":"11","author":"Schwartz","year":"2000","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.ajodo.2021.06.024_bib16","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1136\/heartasia-2016-010828","article-title":"Reuse of pacemakers, defibrillators and cardiac resynchronisation devices","volume":"9","author":"Selvaraj","year":"2017","journal-title":"Heart Asia"},{"key":"10.1016\/j.ajodo.2021.06.024_bib17","doi-asserted-by":"crossref","first-page":"39","DOI":"10.2319\/012014-56.1","article-title":"Effect of different sterilization modes on the surface morphology, ion release, and bone reaction of retrieved micro-implants","volume":"85","author":"El-Wassefy","year":"2015","journal-title":"Angle Orthod"},{"key":"10.1016\/j.ajodo.2021.06.024_bib18","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1111\/j.1365-2591.2007.01371.x","article-title":"Decalcifying effect of 15% EDTA, 15% citric acid, 5% phosphoric acid and 2.5% sodium\u00a0hypochlorite on root canal dentine","volume":"41","author":"P\u00e9rez-Heredia","year":"2008","journal-title":"Int Endod J"},{"key":"10.1016\/j.ajodo.2021.06.024_bib19","doi-asserted-by":"crossref","first-page":"1558","DOI":"10.1016\/j.joen.2010.06.021","article-title":"Tissue dissolution by sodium hypochlorite: effect of concentration, temperature, agitation, and surfactant","volume":"36","author":"Stojicic","year":"2010","journal-title":"J Endod"},{"key":"10.1016\/j.ajodo.2021.06.024_bib20","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1590\/S1516-14392010000400015","article-title":"Is it possible to re-use mini-implants for orthodontic anchorage? Results of an in\u00a0vitro study","volume":"13","author":"Mattos","year":"2010","journal-title":"Mater Res"},{"key":"10.1016\/j.ajodo.2021.06.024_bib21","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1111\/j.1600-0501.2005.01211.x","article-title":"Recommended placement torque when tightening an orthodontic mini-implant","volume":"17","author":"Motoyoshi","year":"2006","journal-title":"Clin Oral Implants Res"},{"key":"10.1016\/j.ajodo.2021.06.024_bib22","doi-asserted-by":"crossref","DOI":"10.1155\/2014\/424923","article-title":"Effect of recycling protocol on mechanical strength of used mini-implants","volume":"2014","author":"Estelita","year":"2014","journal-title":"Int J Dent"},{"key":"10.1016\/j.ajodo.2021.06.024_bib23","doi-asserted-by":"crossref","first-page":"25","DOI":"10.26650\/eor.20197993","article-title":"In-vitro evaluation of the effects of insertion and sterilization procedures on the mechanical and surface characteristics of mini screws","volume":"53","author":"Hergel","year":"2019","journal-title":"Eur Oral Res"},{"key":"10.1016\/j.ajodo.2021.06.024_bib24","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1007\/s00056-006-0611-z","article-title":"Parameters affecting primary stability of orthodontic mini-implants","volume":"67","author":"Wilmes","year":"2006","journal-title":"J Orofac Orthop"},{"key":"10.1016\/j.ajodo.2021.06.024_bib25","first-page":"163","article-title":"Implant diameter and bone density: effect on initial stability and pull-out resistance","volume":"23","author":"Kido","year":"1997","journal-title":"J Oral Implantol"},{"key":"10.1016\/j.ajodo.2021.06.024_bib26","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1016\/j.ajodo.2017.01.026","article-title":"Insertion torque and Periotest values are important factors predicting outcome after orthodontic miniscrew placement","volume":"152","author":"Watanabe","year":"2017","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1016\/j.ajodo.2021.06.024_bib27","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1097\/00008505-199205000-00006","article-title":"An evaluation of the periotest system. Part I: Examiner reliability and repeatability of readings. Dental Implant Clinical Group (planning committee)","volume":"1","author":"Manz","year":"1992","journal-title":"Implant Dent"},{"key":"10.1016\/j.ajodo.2021.06.024_bib28","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1563\/AAID-JOI-D-10-00185","article-title":"Wired\/Classic and Wireless\/Periotest \u201cM\u201d instruments: an in\u00a0vitro assessment of repeatability of stability measurements","volume":"40","author":"Crum","year":"2014","journal-title":"Wired. J Oral Implantol"},{"key":"10.1016\/j.ajodo.2021.06.024_bib29","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.ajodo.2011.07.020","article-title":"Primary stability and histomorphometric bone-implant contact of self-drilling and self-tapping orthodontic microimplants","volume":"141","author":"\u00c7ehreli","year":"2012","journal-title":"Am J Orthod Dentofacial Orthop"}],"container-title":["American Journal of Orthodontics and Dentofacial Orthopedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0889540622004383?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0889540622004383?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T09:13:22Z","timestamp":1760174002000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0889540622004383"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11]]},"references-count":29,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,11]]}},"alternative-id":["S0889540622004383"],"URL":"https:\/\/doi.org\/10.1016\/j.ajodo.2021.06.024","relation":{},"ISSN":["0889-5406"],"issn-type":[{"type":"print","value":"0889-5406"}],"subject":[],"published":{"date-parts":[[2022,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Evaluation of reused orthodontic mini-implants on stability: An in-vivo study","name":"articletitle","label":"Article Title"},{"value":"American Journal of Orthodontics and Dentofacial Orthopedics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ajodo.2021.06.024","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 by the American Association of Orthodontists. All rights reserved.","name":"copyright","label":"Copyright"}]}}