{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T05:22:28Z","timestamp":1793424148216,"version":"4.5.0"},"reference-count":24,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-017"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-012"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-004"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","ajog.org","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Journal of Obstetrics and Gynecology"],"published-print":{"date-parts":[[2024,10]]},"DOI":"10.1016\/j.ajog.2024.01.010","type":"journal-article","created":{"date-parts":[[2024,1,17]],"date-time":"2024-01-17T03:39:23Z","timestamp":1705462763000},"page":"467.e1-467.e8","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":27,"title":["Continuous glucose monitoring in pregnancies with type 1 diabetes: small increases in time-in-range improve maternal and perinatal outcomes"],"prefix":"10.1016","volume":"231","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2856-3185","authenticated-orcid":false,"given":"Nasim C.","family":"Sobhani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sophie","family":"Goemans","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antoinette","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Melissa E.","family":"Chambers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Richley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lauryn C.","family":"Gabby","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nancy","family":"Field","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christina S.","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gladys A.","family":"Ramos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ajog.2024.01.010_bib1","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1016\/S2213-8587(23)00116-X","article-title":"Management of type 1 diabetes in pregnancy: updated on lifestyle, pharmacological treatment, and novel technologies for achieving glycaemic targets","volume":"11","author":"Benhalima","year":"2023","journal-title":"Lancet Diabetes Endocrinol"},{"key":"10.1016\/j.ajog.2024.01.010_bib2","doi-asserted-by":"crossref","first-page":"2005","DOI":"10.2337\/dc09-0656","article-title":"Obstetric and perinatal outcomes in type 1 diabetic pregnancies: a large, population-based study","volume":"32","author":"Persson","year":"2009","journal-title":"Diabetes Care"},{"key":"10.1016\/j.ajog.2024.01.010_bib3","doi-asserted-by":"crossref","first-page":"1046","DOI":"10.2337\/dc08-2061","article-title":"Peri-conceptional A1c and risk of serious adverse pregnancy outcome in 933 women with type 1 diabetes","volume":"32","author":"Jensen","year":"2009","journal-title":"Diabetes Care"},{"key":"10.1016\/j.ajog.2024.01.010_bib4","doi-asserted-by":"crossref","DOI":"10.1001\/jamanetworkopen.2020.30207","article-title":"Association of improved periconception hemoglobin A1c with pregnancy outcomes in women with diabetes","volume":"3","author":"Davidson","year":"2020","journal-title":"JAMA Netw Open"},{"key":"10.1016\/j.ajog.2024.01.010_bib5","doi-asserted-by":"crossref","DOI":"10.1111\/dme.14822","article-title":"Association of change in haemoglobin A1c with adverse perinatal outcomes in women with pregestational diabetes","volume":"39","author":"Kiefer","year":"2022","journal-title":"Diabet Med"},{"key":"10.1016\/j.ajog.2024.01.010_bib6","series-title":"Role of continuous glucose monitoring in diabetes treatment","first-page":"19","article-title":"Continuous glucose monitoring data as an adjunct to A1c","author":"Bergenstal","year":"2018"},{"key":"10.1016\/j.ajog.2024.01.010_bib7","doi-asserted-by":"crossref","first-page":"20","DOI":"10.17925\/EE.2022.18.1.20","article-title":"Utilizing the new glucometrics: a practical guide to ambulatory glucose profile interpretation","volume":"18","author":"Doupis","year":"2022","journal-title":"touchREV Endocrinol"},{"key":"10.1016\/j.ajog.2024.01.010_bib8","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1111\/dom.14906","article-title":"Continuous glucose monitoring metrics (mean glucose, time above range and time in range) are superior to glycated haemoglobin for assessment of therapeutic efficacy","volume":"25","author":"Rodbard","year":"2023","journal-title":"Diabetes Obes Metab"},{"key":"10.1016\/j.ajog.2024.01.010_bib9","doi-asserted-by":"crossref","first-page":"681","DOI":"10.2337\/dc20-2360","article-title":"Novel biochemical markers of glycemia to predict pregnancy outcomes in women with type 1 diabetes","volume":"44","author":"Meek","year":"2021","journal-title":"Diabetes Care"},{"key":"10.1016\/j.ajog.2024.01.010_bib10","doi-asserted-by":"crossref","first-page":"109","DOI":"10.2337\/ds20-0093","article-title":"Clinical application of time in range and other metrics","volume":"34","author":"Aleppo","year":"2021","journal-title":"Diabetes Spectr"},{"key":"10.1016\/j.ajog.2024.01.010_bib11","doi-asserted-by":"crossref","first-page":"1593","DOI":"10.2337\/dci19-0028","article-title":"Clinical targets for continuous glucose monitoring data interpretation: recommendations from the International Consensus on Time in Range","volume":"42","author":"Battelino","year":"2019","journal-title":"Diabetes Care"},{"key":"10.1016\/j.ajog.2024.01.010_bib12","doi-asserted-by":"crossref","first-page":"e237","DOI":"10.1097\/AOG.0000000000003891","article-title":"Gestational hypertension and preeclampsia: ACOG practice bulletin, number 222","volume":"135","year":"2020","journal-title":"Obstet Gynecol"},{"key":"10.1016\/j.ajog.2024.01.010_bib13","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1038\/s41372-020-0698-x","article-title":"Time trends in pregnancy-related outcomes among women with type 1 diabetes mellitus, 2004\u20132017","volume":"40","author":"Helman","year":"2020","journal-title":"J\u00a0Perinatol"},{"key":"10.1016\/j.ajog.2024.01.010_bib14","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1089\/dia.2018.0033","article-title":"Diabetes technology use among pregnant and nonpregnant women with T1D in the T1D Exchange","volume":"20","author":"Polsky","year":"2018","journal-title":"Diabetes Technol Ther"},{"key":"10.1016\/j.ajog.2024.01.010_bib15","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1055\/a-1904-9279","article-title":"Time in range and pregnancy outcomes in people with diabetes using continuous glucose monitoring","volume":"40","author":"Fishel Bartal","year":"2023","journal-title":"Am J Perinatol"},{"key":"10.1016\/j.ajog.2024.01.010_bib16","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.1007\/s00125-019-4850-0","article-title":"Continuous glucose monitoring in pregnant women with type 1 diabetes: an observational cohort study of 186 pregnancies","volume":"62","author":"Kristensen","year":"2019","journal-title":"Diabetologia"},{"key":"10.1016\/j.ajog.2024.01.010_bib17","doi-asserted-by":"crossref","first-page":"1724","DOI":"10.2337\/dc22-0078","article-title":"Continuous glucose monitoring metrics and birth weight: informing management of type 1 diabetes throughout pregnancy","volume":"45","author":"Scott","year":"2022","journal-title":"Diabetes Care"},{"key":"10.1016\/j.ajog.2024.01.010_bib18","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1007\/s00125-019-4904-3","article-title":"Continuous glucose monitoring targets in type 1 diabetes pregnancy: every 5% time in range matters","volume":"62","author":"Murphy","year":"2019","journal-title":"Diabetologia"},{"key":"10.1016\/j.ajog.2024.01.010_bib19","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1089\/dia.2021.0112","article-title":"Longitudinal observation of insulin use and glucose sensor metrics in pregnant women with type 1 diabetes using continuous glucose monitors and insulin pumps: the LOIS-P study","volume":"23","author":"O\u2019Malley","year":"2021","journal-title":"Diabetes Technol Ther"},{"key":"10.1016\/j.ajog.2024.01.010_bib20","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1089\/dia.2021.0073","article-title":"Continuous glucose monitoring time-in-range and HbA1c targets in pregnant women with type 1 diabetes","volume":"23","author":"Tundidor","year":"2021","journal-title":"Diabetes Technol Ther"},{"key":"10.1016\/j.ajog.2024.01.010_bib21","doi-asserted-by":"crossref","first-page":"118","DOI":"10.2337\/ds18-0035","article-title":"\u201dDiabetes just tends to take over everything\u201d: experiences of support and barriers to diabetes management for pregnancy in women with type 1 diabetes","volume":"32","author":"Singh","year":"2019","journal-title":"Diabetes Spectr"},{"key":"10.1016\/j.ajog.2024.01.010_bib22","doi-asserted-by":"crossref","DOI":"10.1001\/jamanetworkopen.2022.33955","article-title":"Glycemic control trajectories and risk of perinatal complications among individuals with gestational diabetes","volume":"5","author":"Chehab","year":"2022","journal-title":"JAMA Netw Open"},{"key":"10.1016\/j.ajog.2024.01.010_bib23","doi-asserted-by":"crossref","first-page":"2175","DOI":"10.3390\/biomedicines10092175","article-title":"Glycemic variability in type 1 diabetes mellitus pregnancies-novel parameters in predicting large-for-gestational-age neonates: a prospective cohort study","volume":"10","author":"Leksic","year":"2022","journal-title":"Biomedicines"},{"key":"10.1016\/j.ajog.2024.01.010_bib24","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1089\/dia.2021.0093","article-title":"Relationship between time-in-range, HbA1c, and the glucose management indicator in pregnancies complicated by type 1 diabetes","volume":"23","author":"Shah","year":"2021","journal-title":"Diabetes Technol Ther"}],"container-title":["American Journal of Obstetrics and Gynecology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002937824000243?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002937824000243?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,9,17]],"date-time":"2024-09-17T13:44:34Z","timestamp":1726580674000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002937824000243"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10]]},"references-count":24,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,10]]}},"alternative-id":["S0002937824000243"],"URL":"https:\/\/doi.org\/10.1016\/j.ajog.2024.01.010","relation":{},"ISSN":["0002-9378"],"issn-type":[{"value":"0002-9378","type":"print"}],"subject":[],"published":{"date-parts":[[2024,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Continuous glucose monitoring in pregnancies with type 1 diabetes: small increases in time-in-range improve maternal and perinatal outcomes","name":"articletitle","label":"Article Title"},{"value":"American Journal of Obstetrics and Gynecology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ajog.2024.01.010","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}