{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T03:12:56Z","timestamp":1790737976184,"version":"4.1.0"},"reference-count":31,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,1,18]],"date-time":"2024-01-18T00:00:00Z","timestamp":1705536000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100005744","name":"Lastentautien Tutkimuss\u00e4\u00e4ti\u00f6","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005744","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100010135","name":"Finska L\u00e4kares\u00e4llskapet","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100010135","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["ajog.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["American Journal of Obstetrics and Gynecology"],"published-print":{"date-parts":[[2024,4]]},"DOI":"10.1016\/j.ajog.2024.01.011","type":"journal-article","created":{"date-parts":[[2024,1,22]],"date-time":"2024-01-22T20:57:25Z","timestamp":1705957045000},"page":"379.e1-379.e12","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":25,"title":["Intrapartum cardiotocography with simultaneous maternal heart rate registration improves neonatal outcome"],"prefix":"10.1016","volume":"230","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3289-2173","authenticated-orcid":false,"given":"Mikko","family":"Tarvonen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Janne","family":"Markkanen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ville","family":"Tuppurainen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Riina","family":"Jernman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vedran","family":"Stefanovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sture","family":"Andersson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.ajog.2024.01.011_bib1","doi-asserted-by":"crossref","first-page":"26.e1","DOI":"10.1016\/j.ajog.2007.03.037","article-title":"A\u00a0framework for standardized management of intrapartum fetal heart rate patterns","volume":"197","author":"Parer","year":"2007","journal-title":"Am J Obstet Gynecol"},{"key":"10.1016\/j.ajog.2024.01.011_bib2","doi-asserted-by":"crossref","first-page":"1797","DOI":"10.1111\/1471-0528.13817","article-title":"Neonatal complications associated with use of fetal scalp electrode: a\u00a0retrospective study","volume":"123","author":"Kawakita","year":"2016","journal-title":"BJOG"},{"key":"10.1016\/j.ajog.2024.01.011_bib3","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.ejogrb.2004.01.001","article-title":"The quality of intrapartum fetal heart rate monitoring","volume":"116","author":"Bakker","year":"2004","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"key":"10.1016\/j.ajog.2024.01.011_bib4","doi-asserted-by":"crossref","first-page":"1306","DOI":"10.1111\/j.1600-0412.2012.01533.x","article-title":"Accuracy and reliability of fetal heart rate monitoring using maternal abdominal surface electrodes","volume":"91","author":"Cohen","year":"2012","journal-title":"Acta Obstet Gynecol Scand"},{"key":"10.1016\/j.ajog.2024.01.011_bib5","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.bpobgyn.2015.05.005","article-title":"Technical characteristics of current cardiotocographic monitors","volume":"30","author":"Ayres-de-Campos","year":"2016","journal-title":"Best Pract Res Clin Obstet Gynaecol"},{"key":"10.1016\/j.ajog.2024.01.011_bib6","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1016\/j.jogc.2022.06.002","article-title":"Technical update no. 429: maternal heart rate artefact during intrapartum fetal health surveillance","volume":"44","author":"Kiely","year":"2022","journal-title":"J\u00a0Obstet Gynaecol Can"},{"key":"10.1016\/j.ajog.2024.01.011_bib7","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1109\/TUFFC.2019.2943626","article-title":"Doppler ultrasound technology for fetal heart rate monitoring: a review","volume":"67","author":"Hamelmann","year":"2020","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"10.1016\/j.ajog.2024.01.011_bib8","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.ijgo.2015.06.020","article-title":"FIGO Intrapartum Fetal Monitoring Expert Consensus Panel. FIGO consensus guidelines on intrapartum fetal monitoring: cardiotocography","volume":"131","author":"Ayres-de-Campos","year":"2015","journal-title":"Int J Gynaecol Obstet"},{"key":"10.1016\/j.ajog.2024.01.011_bib9","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1177\/0884217503261161","article-title":"Maternal or fetal heart rate? Avoiding intrapartum misidentification","volume":"33","author":"Murray","year":"2004","journal-title":"J\u00a0Obstet Gynecol Neonatal Nurs"},{"key":"10.1016\/j.ajog.2024.01.011_bib10","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1097\/JPN.0000000000000404","article-title":"When signals become crossed: maternal-fetal signal ambiguity","volume":"33","author":"Cypher","year":"2019","journal-title":"J\u00a0Perinat Neonatal Nurs"},{"key":"10.1016\/j.ajog.2024.01.011_bib11","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1186\/s12884-015-0739-1","article-title":"Improvements in fetal heart rate analysis by the removal of maternal-fetal heart rate ambiguities","volume":"15","author":"Pinto","year":"2015","journal-title":"BMC Pregnancy Childbirth"},{"key":"10.1016\/j.ajog.2024.01.011_bib12","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1007\/s11517-015-1359-7","article-title":"Toward the improvement in fetal monitoring during labor with the inclusion of maternal heart rate analysis","volume":"54","author":"Gon\u00e7alves","year":"2016","journal-title":"Med Biol Eng Comput"},{"key":"10.1016\/j.ajog.2024.01.011_bib13","doi-asserted-by":"crossref","first-page":"598","DOI":"10.1111\/j.1600-0412.2012.01371.x","article-title":"Maternal heart rate patterns in the first and second stages of labor","volume":"91","author":"van Veen","year":"2012","journal-title":"Acta Obstet Gynecol Scand"},{"key":"10.1016\/j.ajog.2024.01.011_bib14","doi-asserted-by":"crossref","first-page":"2070","DOI":"10.1111\/1471-0528.17234","article-title":"Increased variability of fetal heart rate during labour: a review of preclinical and clinical studies","volume":"129","author":"Tarvonen","year":"2022","journal-title":"BJOG"},{"key":"10.1016\/j.ajog.2024.01.011_bib15","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1016\/j.ajog.2022.05.023","article-title":"Pathophysiological interpretation of fetal heart rate tracings in clinical practice","volume":"228","author":"Jia","year":"2023","journal-title":"Am J Obstet Gynecol"},{"key":"10.1016\/j.ajog.2024.01.011_bib16","doi-asserted-by":"crossref","first-page":"942","DOI":"10.1111\/apa.14234","article-title":"Low Apgar scores at both one and five minutes are associated with long-term neurological morbidity","volume":"107","author":"Leinonen","year":"2018","journal-title":"Acta Paediatr"},{"key":"10.1016\/j.ajog.2024.01.011_bib17","doi-asserted-by":"crossref","DOI":"10.1016\/j.spen.2023.101072","article-title":"An update of our understanding of fetal heart rate patterns in health and disease","volume":"47","author":"Lear","year":"2023","journal-title":"Semin Pediatr Neurol"},{"key":"10.1016\/j.ajog.2024.01.011_bib18","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1016\/j.clp.2007.03.010","article-title":"Medical legal issues in fetal monitoring","volume":"34","author":"Schifrin","year":"2007","journal-title":"Clin Perinatol"},{"key":"10.1016\/j.ajog.2024.01.011_bib19","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1186\/s12884-019-2660-5","article-title":"Unrecognized maternal heart rate artefact in cases of perinatal mortality reported to the United States Food and Drug Administration from 2009 to 2019: a critical patient safety issue","volume":"19","author":"Kiely","year":"2019","journal-title":"BMC Pregnancy Childbirth"},{"key":"10.1016\/j.ajog.2024.01.011_bib20","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/0029-7844(94)00320-D","article-title":"Intrapartum electronic fetal heart rate monitoring versus intermittent auscultation: a meta-analysis","volume":"85","author":"Vintzileos","year":"1995","journal-title":"Obstet Gynecol"},{"key":"10.1016\/j.ajog.2024.01.011_bib21","first-page":"CD006066","article-title":"Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour","volume":"2","author":"Alfirevic","year":"2017","journal-title":"Cochrane Database Syst Rev"},{"key":"10.1016\/j.ajog.2024.01.011_bib22","doi-asserted-by":"crossref","first-page":"E468","DOI":"10.1503\/cmaj.202538","article-title":"Effectiveness of intrapartum fetal surveillance to improve maternal and neonatal outcomes: a systematic review and network meta-analysis","volume":"193","author":"Al Wattar","year":"2021","journal-title":"CMAJ"},{"key":"10.1016\/j.ajog.2024.01.011_bib23","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1016\/S1701-2163(15)30408-4","article-title":"The incidence of maternal artefact during intrapartum fetal heart rate monitoring","volume":"36","author":"Paquette","year":"2014","journal-title":"J\u00a0Obstet Gynaecol Can"},{"key":"10.1016\/j.ajog.2024.01.011_bib24","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1159\/000345059","article-title":"Intrapartum heart rate ambiguity: a comparison of cardiotocogram and abdominal fetal electrocardiogram with maternal electrocardiogram","volume":"75","author":"Reinhard","year":"2013","journal-title":"Gynecol Obstet Invest"},{"key":"10.1016\/j.ajog.2024.01.011_bib25","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/j.ajog.2008.02.030","article-title":"Signal ambiguity resulting in unexpected outcome with external fetal heart rate monitoring","volume":"198","author":"Neilson","year":"2008","journal-title":"Am J Obstet Gynecol"},{"key":"10.1016\/j.ajog.2024.01.011_bib26","first-page":"542","article-title":"Characteristics of maternal heart rate patterns during labor and delivery","volume":"99","author":"Sherman","year":"2002","journal-title":"Obstet Gynecol"},{"key":"10.1016\/j.ajog.2024.01.011_bib27","doi-asserted-by":"crossref","first-page":"1615","DOI":"10.1080\/14767058.2017.1411476","article-title":"Incidence of maternal tachycardia during the second stage of labor: a prospective observational cohort study","volume":"32","author":"Towers","year":"2019","journal-title":"J\u00a0Matern Fetal Neonatal Med"},{"key":"10.1016\/j.ajog.2024.01.011_bib28","doi-asserted-by":"crossref","first-page":"1428","DOI":"10.1111\/j.1600-0412.2012.01511.x","article-title":"Misidentification of maternal heart rate as fetal on cardiotocography during the second stage of labor: the role of the fetal electrocardiograph","volume":"91","author":"Nurani","year":"2012","journal-title":"Acta Obstet Gynecol Scand"},{"key":"10.1016\/j.ajog.2024.01.011_bib29","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/0020-7292(90)90013-B","article-title":"Maternal ECG recorded by internal monitoring closely mimicking fetal heart rate in a recent fetal death","volume":"33","author":"Herman","year":"1990","journal-title":"Int J Gynaecol Obstet"},{"key":"10.1016\/j.ajog.2024.01.011_bib30","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1056\/NEJMoa1500600","article-title":"A\u00a0randomized trial of intrapartum fetal ECG ST-segment analysis","volume":"373","author":"Belfort","year":"2015","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.ajog.2024.01.011_bib31","doi-asserted-by":"crossref","first-page":"163.e1","DOI":"10.1016\/j.ajog.2016.10.009","article-title":"The limits of electronic fetal heart rate monitoring in the prevention of neonatal metabolic acidemia","volume":"216","author":"Clark","year":"2017","journal-title":"Am J Obstet Gynecol"}],"container-title":["American Journal of Obstetrics and Gynecology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002937824000334?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0002937824000334?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T00:40:05Z","timestamp":1777336805000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0002937824000334"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4]]},"references-count":31,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,4]]}},"alternative-id":["S0002937824000334"],"URL":"https:\/\/doi.org\/10.1016\/j.ajog.2024.01.011","relation":{},"ISSN":["0002-9378"],"issn-type":[{"value":"0002-9378","type":"print"}],"subject":[],"published":{"date-parts":[[2024,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Intrapartum cardiotocography with simultaneous maternal heart rate registration improves neonatal outcome","name":"articletitle","label":"Article Title"},{"value":"American Journal of Obstetrics and Gynecology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ajog.2024.01.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Author(s). Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}